Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -87,6 +87,7 @@ 87 87 88 88 = Create communication with WECON PLC = 89 89 90 +== **LX3V Serial Protocol** == 90 90 91 91 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 92 92 ... ... @@ -140,7 +140,8 @@ 140 140 141 141 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 142 142 143 -== HMI settings == 144 +(% class="wikigeneratedid" id="HHMIsettings" %) 145 +**HMI settings** 144 144 145 145 **Download PIStudio Software** 146 146 ... ... @@ -229,7 +229,8 @@ 229 229 * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]] 230 230 * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]] 231 231 232 -== PLC settings == 234 +(% class="wikigeneratedid" id="HPLCsettings" %) 235 +**PLC settings** 233 233 234 234 **Download PLC Software** 235 235 ... ... @@ -314,7 +314,7 @@ 314 314 (% style="text-align:center" %) 315 315 [[image:image-20220819105928-9.png||height="229" width="669"]] 316 316 317 -= ** HMI and WeconLX5Vserialcommunication** =320 +== **LX5V Serial Protocol** == 318 318 319 319 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 320 320 ... ... @@ -392,11 +392,10 @@ 392 392 393 393 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 394 394 395 -== ** HMI and WeconLX5V-N Ethernetcommunication** ==398 +== **LX5V-N Ethernet protocol** == 396 396 397 397 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 398 398 399 - 400 400 **Software configuration of PLC** 401 401 402 402 **1)PLC programming software** ... ... @@ -466,10 +466,49 @@ 466 466 467 467 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 468 468 469 -= = 471 += Create communication with **Rockwell PLC** = 470 470 471 -= ** Allen-Bradley** =473 +== **MicroLogix Protocol** == 472 472 475 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 476 + 477 +**HMI Settings** 478 + 479 +(% class="table-bordered" %) 480 +|**Item**|**Settings**|**Note** 481 +|Protocol|Allen-Bradlley MicroLogix| 482 +|Connection|RS232| 483 +|Baud rate|19200| 484 +|Data bit|8| 485 +|Parity|None| 486 +|Stop bit|1| 487 +|PLC station No.|1| 488 + 489 +**Address List** 490 + 491 +(% class="table-bordered" %) 492 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 493 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 494 +|O|O d.d|0.0~~255.15| 495 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 496 +|S|S d.d|0.0~~255.15| 497 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 498 +|(% rowspan="9" %)Word|S|S d|0~~255| 499 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 500 +|TP|TP nnhh|0~~ffff 501 +|CS|CS nnhh|0~~ffff 502 +|CP|CP nnhh|0~~ffff 503 +|N|N nnhh|0~~ffff 504 +|C|C nnhh|0~~ffff 505 +|T|T nnhh|0~~ffff 506 +|R|R nnhh|0~~ffff 507 + 508 +**Cable Wiring** 509 + 510 + 511 +(% style="text-align:center" %) 512 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 513 + 473 473 == **FreeTag Ethernet/IP (CompactLogix)** == 474 474 475 475 Allen-Brandly CompactLogix ... ... @@ -527,46 +527,6 @@ 527 527 (% style="text-align:center" %) 528 528 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 529 529 530 -== **MicroLogix** == 531 - 532 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 533 - 534 -**HMI Settings** 535 - 536 -(% class="table-bordered" %) 537 -|**Item**|**Settings**|**Note** 538 -|Protocol|Allen-Bradlley MicroLogix| 539 -|Connection|RS232| 540 -|Baud rate|19200| 541 -|Data bit|8| 542 -|Parity|None| 543 -|Stop bit|1| 544 -|PLC station No.|1| 545 - 546 -**Address List** 547 - 548 -(% class="table-bordered" %) 549 -|**Type**|**Device registers**|**Format**|**Range**|**Note** 550 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 551 -|O|O d.d|0.0~~255.15| 552 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 553 -|S|S d.d|0.0~~255.15| 554 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 555 -|(% rowspan="9" %)Word|S|S d|0~~255| 556 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 557 -|TP|TP nnhh|0~~ffff 558 -|CS|CS nnhh|0~~ffff 559 -|CP|CP nnhh|0~~ffff 560 -|N|N nnhh|0~~ffff 561 -|C|C nnhh|0~~ffff 562 -|T|T nnhh|0~~ffff 563 -|R|R nnhh|0~~ffff 564 - 565 -**Cable Wiring** 566 - 567 -(% style="text-align:center" %) 568 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 569 - 570 570 == **AB PLC address edit** == 571 571 572 572 The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. ... ... @@ -593,286 +593,8 @@ 593 593 |(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF 594 594 |(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF 595 595 596 -= **BarcodeScanner**=597 += = 597 597 598 -Supported: DELI 14880 barcode scanner 599 - 600 -**HMI Setting** 601 - 602 -(% class="table-bordered" %) 603 -|**Items**|**Settings**|**Note** 604 -|Protocol|Barcode Scanner| 605 -|Connection|USB| 606 - 607 -**Operating Procedures** 608 - 609 -Select [Barcode Scanner]; 610 - 611 -(% style="text-align:center" %) 612 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 613 - 614 -Set address for receiving; 615 - 616 -Set correct length; 617 - 618 -(% style="text-align:center" %) 619 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 620 - 621 -**✎Note:** 622 - 623 -* The protocol uploads the information acquired by the USB scanner to the HMI; 624 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 625 -* Recommended model: DELI 14880 barcode scanner; 626 - 627 -= **Hitachi EHV Series (Ethernet)** = 628 - 629 -Supported series: Hitachi EHV series 630 - 631 -**HMI Settings** 632 - 633 -(% class="table-bordered" %) 634 -|**Items**|**Settings**|**Note** 635 -|Protocol|Hitachi EHV series| 636 -|Connection|Ethernet| 637 -|Port No.|3004~~3007| 638 - 639 -**Address List** 640 - 641 -(% class="table-bordered" %) 642 -|**Type**|**Register**|**Range**|**Format**|**Note** 643 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 644 -|M|0 - 7FFF.f (Hex)|M HHHH.h| 645 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 646 -H1H2H3H4 Module main number 647 - 648 -H1: Remote number 649 - 650 -H2: Unit number 651 - 652 -H3: Slot number 653 - 654 -H4: Word number of Module 655 - 656 -H Sub number of Module 657 - 658 -For example:X21.3 659 - 660 -Slot number 2 661 - 662 -Word number of module is 1 663 - 664 -Bit number of module is 3 665 - 666 -Remote number and unit number are 0 667 -))) 668 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 669 -|R|0 – FF.f (Hex)|R HH.h| 670 -|L|0 - 73FF.f (Hex)|L HHHH.h| 671 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 672 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 673 -H1H2H3H4 Module main number 674 - 675 -H1: Remote number 676 - 677 -H2: Unit number 678 - 679 -H3: Slot number 680 - 681 -H4: Word number of module 682 - 683 -For example:WX21 684 - 685 -Word number of module is 1 686 - 687 -Slot number is 2 688 - 689 -Remote number and unit number are 0 690 -))) 691 -|WY|0 – FFFF (Hex)|WY H1H2H3H4 692 -|WR|0 – FFFF (Hex)|WR HHHH| 693 -|WL|0 - 73FF (Hex)|WL HHHH| 694 -|TC|0 - 2559|TC DDDD| 695 - 696 -**Communication settings in HMI** 697 - 698 -Enable HMI Ethernet in [Project Settings]; 699 - 700 -(% style="text-align:center" %) 701 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 702 - 703 -Set PLC IP in [Device IP] settings; 704 - 705 -(% style="text-align:center" %) 706 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 707 - 708 -**PLC Configuration** 709 - 710 -Connect with PLC, select[Online mode]; 711 - 712 -(% style="text-align:center" %) 713 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 714 - 715 -Set IP address, it is the same LAN parameters with HMI; 716 - 717 -(% style="text-align:center" %) 718 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 719 - 720 -3) Save PLC communication parameter, and restart PLC 721 - 722 -**PLC Monitor Mode** 723 - 724 -Connect with PLC and choose to “online” mode 725 - 726 -(% style="text-align:center" %) 727 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 728 - 729 -Open I/O monitor sheet1 730 - 731 -(% style="text-align:center" %) 732 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 733 - 734 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 735 - 736 -(% style="text-align:center" %) 737 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 738 - 739 -Enter the register address, click OK to view the value of the register. 740 - 741 -(% style="text-align:center" %) 742 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 743 - 744 -(% style="text-align:center" %) 745 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 746 - 747 -**✎Note:** 748 - 749 -* Both word registers and bit registers support even continuous read/write functions; 750 -* The range of registers is based on the specific PLC type; 751 - 752 -**Cable Wiring** 753 - 754 -(% style="text-align:center" %) 755 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 756 - 757 -= **IEC60870-5 104 Client** = 758 - 759 -**HMI Setting** 760 - 761 -(% class="table-bordered" %) 762 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 763 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 764 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 765 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 766 - 767 -**Address List** 768 - 769 -(% class="table-bordered" %) 770 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 771 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 772 -|(% style="width:461px" %)SCNA|0~~16777215.7 773 -|(% style="width:461px" %)DPTB|0~~16777215.7 774 -|(% style="width:461px" %)DCNA|0~~16777215.7 775 -|(% style="width:461px" %)METF|0~~16777215.7 776 -|(% style="width:461px" %)SENC|0~~16777215.7 777 -|(% style="width:461px" %)SENA|0~~16777215.7 778 -|(% style="width:461px" %)MENA|0~~16777215.7 779 -|(% style="width:461px" %)METD|0~~16777215.7 780 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 781 -|(% style="width:461px" %)SCNA|0~~16777215 782 -|(% style="width:461px" %)DPTB|0~~16777215 783 -|(% style="width:461px" %)DCNA|0~~16777215 784 -|(% style="width:461px" %)SENA|0~~16777215 785 -|(% style="width:461px" %)MENA|0~~16777215 786 -|(% style="width:461px" %)METD|0~~16777215 787 -|(% style="width:461px" %)INRO|0~~16777215 788 -|(% style="width:461px" %)TIMESYN|0~~16777215 789 -|(% style="width:461px" %)TIMEZ|0~~16777215 790 -|(% style="width:461px" %)NTP|0~~16777215 791 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 792 -|(% style="width:461px" %)SENC|0~~16777215 793 - 794 -**Address Configuration** 795 - 796 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 797 - 798 -(% style="text-align:center" %) 799 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 800 - 801 -(% style="text-align:center" %) 802 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 803 - 804 -Extended tag name 805 - 806 -Address range for the extended tag. 807 - 808 -**Communication Settings** 809 - 810 -Enable HMI Ethernet in [Project Settings]; 811 - 812 -(% style="text-align:center" %) 813 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 814 - 815 -Set PLC IP in [Device IP] settings; 816 - 817 -(% style="text-align:center" %) 818 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 819 - 820 -**Cable Wiring** 821 - 822 -(% style="text-align:center" %) 823 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 824 - 825 -= **LG XGK FEnet Ethernet** = 826 - 827 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 828 - 829 -**HMI Settings** 830 - 831 -(% class="table-bordered" %) 832 -|**Items**|**Settings**|**Note** 833 -|Protocol|LG XGK FEnet(Ethernet)| 834 -|Connection|Ethernet| 835 -|Port No.|2004| 836 - 837 -**Address List** 838 - 839 -(% class="table-bordered" %) 840 -|**Type**|**Register**|**Range**|**Format**|**Note** 841 -|(% rowspan="14" %)Word|P|0~~2047|P d| 842 -|M|0~~2047|M d| 843 -|K|0~~2047|K d| 844 -|F|0~~2047|F d| 845 -|T|0~~2047|T d| 846 -|C|0~~2047|C d| 847 -|Z|0~~127|Z d| 848 -|S|0~~127|S d| 849 -|L|0~~11263|L d| 850 -|N|0~~21503|N d| 851 -|D|0~~32767|D d| 852 -|R|0~~32767|R d| 853 -|ZR|0~~65535|ZR d| 854 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 855 - 856 -**✎Note:** 857 - 858 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 859 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 860 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 861 - 862 -**Communication settings in HMI** 863 - 864 -Enable HMI Ethernet in [Project Settings]; 865 - 866 -(% style="text-align:center" %) 867 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 868 - 869 -Set PLC IP in [Device IP] settings; 870 - 871 -(% style="text-align:center" %) 872 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 873 - 874 -**Cable Wiring** 875 - 876 876 = **Mitsubishi** = 877 877 878 878 == **FX1S, 1N, 2N Series** == ... ... @@ -2646,8 +2646,6 @@ 2646 2646 2647 2647 **✎Note:** COM3 only available in PI8000/PI9000 series. 2648 2648 2649 -= = 2650 - 2651 2651 = **Printer** = 2652 2652 2653 2653 == **TSPL label printer** == ... ... @@ -2848,3 +2848,283 @@ 2848 2848 2849 2849 (% style="text-align:center" %) 2850 2850 [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]] 2572 + 2573 += **Barcode Scanner** = 2574 + 2575 +Supported: DELI 14880 barcode scanner 2576 + 2577 +**HMI Setting** 2578 + 2579 +|**Items**|**Settings**|**Note** 2580 +|Protocol|Barcode Scanner| 2581 +|Connection|USB| 2582 + 2583 +**Operating Procedures** 2584 + 2585 +Select [Barcode Scanner]; 2586 + 2587 +(% style="text-align:center" %) 2588 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 2589 + 2590 +Set address for receiving; 2591 + 2592 +Set correct length; 2593 + 2594 +(% style="text-align:center" %) 2595 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 2596 + 2597 +**✎Note:** 2598 + 2599 +* The protocol uploads the information acquired by the USB scanner to the HMI; 2600 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 2601 +* Recommended model: DELI 14880 barcode scanner; 2602 + 2603 + 2604 += **Hitachi EHV Series (Ethernet)** = 2605 + 2606 +Supported series: Hitachi EHV series 2607 + 2608 +**HMI Settings** 2609 + 2610 +(% class="table-bordered" %) 2611 +|**Items**|**Settings**|**Note** 2612 +|Protocol|Hitachi EHV series| 2613 +|Connection|Ethernet| 2614 +|Port No.|3004~~3007| 2615 + 2616 +**Address List** 2617 + 2618 +(% class="table-bordered" %) 2619 +|**Type**|**Register**|**Range**|**Format**|**Note** 2620 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 2621 +|M|0 - 7FFF.f (Hex)|M HHHH.h| 2622 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 2623 +H1H2H3H4 Module main number 2624 + 2625 +H1: Remote number 2626 + 2627 +H2: Unit number 2628 + 2629 +H3: Slot number 2630 + 2631 +H4: Word number of Module 2632 + 2633 +H Sub number of Module 2634 + 2635 +For example:X21.3 2636 + 2637 +Slot number 2 2638 + 2639 +Word number of module is 1 2640 + 2641 +Bit number of module is 3 2642 + 2643 +Remote number and unit number are 0 2644 +))) 2645 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 2646 +|R|0 – FF.f (Hex)|R HH.h| 2647 +|L|0 - 73FF.f (Hex)|L HHHH.h| 2648 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 2649 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 2650 +H1H2H3H4 Module main number 2651 + 2652 +H1: Remote number 2653 + 2654 +H2: Unit number 2655 + 2656 +H3: Slot number 2657 + 2658 +H4: Word number of module 2659 + 2660 +For example:WX21 2661 + 2662 +Word number of module is 1 2663 + 2664 +Slot number is 2 2665 + 2666 +Remote number and unit number are 0 2667 +))) 2668 +|WY|0 – FFFF (Hex)|WY H1H2H3H4 2669 +|WR|0 – FFFF (Hex)|WR HHHH| 2670 +|WL|0 - 73FF (Hex)|WL HHHH| 2671 +|TC|0 - 2559|TC DDDD| 2672 + 2673 +**Communication settings in HMI** 2674 + 2675 +Enable HMI Ethernet in [Project Settings]; 2676 + 2677 +(% style="text-align:center" %) 2678 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2679 + 2680 +Set PLC IP in [Device IP] settings; 2681 + 2682 +(% style="text-align:center" %) 2683 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 2684 + 2685 +**PLC Configuration** 2686 + 2687 +Connect with PLC, select[Online mode]; 2688 + 2689 +(% style="text-align:center" %) 2690 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 2691 + 2692 +Set IP address, it is the same LAN parameters with HMI; 2693 + 2694 +(% style="text-align:center" %) 2695 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 2696 + 2697 +3) Save PLC communication parameter, and restart PLC 2698 + 2699 +**PLC Monitor Mode** 2700 + 2701 +Connect with PLC and choose to “online” mode 2702 + 2703 +(% style="text-align:center" %) 2704 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 2705 + 2706 +Open I/O monitor sheet1 2707 + 2708 +(% style="text-align:center" %) 2709 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 2710 + 2711 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 2712 + 2713 +(% style="text-align:center" %) 2714 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 2715 + 2716 +Enter the register address, click OK to view the value of the register. 2717 + 2718 +(% style="text-align:center" %) 2719 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2720 + 2721 +(% style="text-align:center" %) 2722 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2723 + 2724 +**✎Note:** 2725 + 2726 +* Both word registers and bit registers support even continuous read/write functions; 2727 +* The range of registers is based on the specific PLC type; 2728 + 2729 +**Cable Wiring** 2730 + 2731 +(% style="text-align:center" %) 2732 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2733 + 2734 += **IEC60870-5 104 Client** = 2735 + 2736 +**HMI Setting** 2737 + 2738 +(% class="table-bordered" %) 2739 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 2740 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 2741 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 2742 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 2743 + 2744 +**Address List** 2745 + 2746 +(% class="table-bordered" %) 2747 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 2748 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 2749 +|(% style="width:461px" %)SCNA|0~~16777215.7 2750 +|(% style="width:461px" %)DPTB|0~~16777215.7 2751 +|(% style="width:461px" %)DCNA|0~~16777215.7 2752 +|(% style="width:461px" %)METF|0~~16777215.7 2753 +|(% style="width:461px" %)SENC|0~~16777215.7 2754 +|(% style="width:461px" %)SENA|0~~16777215.7 2755 +|(% style="width:461px" %)MENA|0~~16777215.7 2756 +|(% style="width:461px" %)METD|0~~16777215.7 2757 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 2758 +|(% style="width:461px" %)SCNA|0~~16777215 2759 +|(% style="width:461px" %)DPTB|0~~16777215 2760 +|(% style="width:461px" %)DCNA|0~~16777215 2761 +|(% style="width:461px" %)SENA|0~~16777215 2762 +|(% style="width:461px" %)MENA|0~~16777215 2763 +|(% style="width:461px" %)METD|0~~16777215 2764 +|(% style="width:461px" %)INRO|0~~16777215 2765 +|(% style="width:461px" %)TIMESYN|0~~16777215 2766 +|(% style="width:461px" %)TIMEZ|0~~16777215 2767 +|(% style="width:461px" %)NTP|0~~16777215 2768 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 2769 +|(% style="width:461px" %)SENC|0~~16777215 2770 + 2771 +**Address Configuration** 2772 + 2773 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 2774 + 2775 +(% style="text-align:center" %) 2776 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 2777 + 2778 +(% style="text-align:center" %) 2779 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 2780 + 2781 +Extended tag name 2782 + 2783 +Address range for the extended tag. 2784 + 2785 +**Communication Settings** 2786 + 2787 +Enable HMI Ethernet in [Project Settings]; 2788 + 2789 +(% style="text-align:center" %) 2790 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2791 + 2792 +Set PLC IP in [Device IP] settings; 2793 + 2794 +(% style="text-align:center" %) 2795 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 2796 + 2797 +**Cable Wiring** 2798 + 2799 +(% style="text-align:center" %) 2800 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2801 + 2802 += **LG XGK FEnet Ethernet** = 2803 + 2804 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2805 + 2806 +**HMI Settings** 2807 + 2808 +(% class="table-bordered" %) 2809 +|**Items**|**Settings**|**Note** 2810 +|Protocol|LG XGK FEnet(Ethernet)| 2811 +|Connection|Ethernet| 2812 +|Port No.|2004| 2813 + 2814 +**Address List** 2815 + 2816 +(% class="table-bordered" %) 2817 +|**Type**|**Register**|**Range**|**Format**|**Note** 2818 +|(% rowspan="14" %)Word|P|0~~2047|P d| 2819 +|M|0~~2047|M d| 2820 +|K|0~~2047|K d| 2821 +|F|0~~2047|F d| 2822 +|T|0~~2047|T d| 2823 +|C|0~~2047|C d| 2824 +|Z|0~~127|Z d| 2825 +|S|0~~127|S d| 2826 +|L|0~~11263|L d| 2827 +|N|0~~21503|N d| 2828 +|D|0~~32767|D d| 2829 +|R|0~~32767|R d| 2830 +|ZR|0~~65535|ZR d| 2831 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 2832 + 2833 +**✎Note:** 2834 + 2835 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 2836 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 2837 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 2838 + 2839 +**Communication settings in HMI** 2840 + 2841 +Enable HMI Ethernet in [Project Settings]; 2842 + 2843 +(% style="text-align:center" %) 2844 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2845 + 2846 +Set PLC IP in [Device IP] settings; 2847 + 2848 +(% style="text-align:center" %) 2849 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 2850 + 2851 +**Cable Wiring**