Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 66.1
edited by Ben
on 2022/08/29 14:06
Change comment: There is no comment for this version
To version 77.1
edited by Ben
on 2022/08/29 14:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -87,6 +87,7 @@
87 87  
88 88  = Create communication with WECON PLC =
89 89  
90 +== **LX3V Serial Protocol** ==
90 90  
91 91  Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM
92 92  
... ... @@ -140,7 +140,8 @@
140 140  
141 141  [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]]
142 142  
143 -== HMI settings ==
144 +(% class="wikigeneratedid" id="HHMIsettings" %)
145 +**HMI settings**
144 144  
145 145  **Download PIStudio Software**
146 146  
... ... @@ -229,7 +229,8 @@
229 229  * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]]
230 230  * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]]
231 231  
232 -== PLC settings ==
234 +(% class="wikigeneratedid" id="HPLCsettings" %)
235 +**PLC settings**
233 233  
234 234  **Download PLC Software**
235 235  
... ... @@ -314,7 +314,7 @@
314 314  (% style="text-align:center" %)
315 315  [[image:image-20220819105928-9.png||height="229" width="669"]]
316 316  
317 -= **HMI and Wecon LX5V serial communication** =
320 +== **LX5V Serial Protocol** ==
318 318  
319 319  This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
320 320  
... ... @@ -392,11 +392,10 @@
392 392  
393 393  The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC.
394 394  
395 -== **HMI and Wecon LX5V-N Ethernet communication** ==
398 +== **LX5V-N Ethernet protocol** ==
396 396  
397 397  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
398 398  
399 -
400 400  **Software configuration of PLC**
401 401  
402 402  **1)PLC programming software**
... ... @@ -466,10 +466,49 @@
466 466  
467 467  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
468 468  
469 -= =
471 += Create communication with **Rockwell PLC** =
470 470  
471 -= **Allen-Bradley** =
473 +== **MicroLogix Protocol** ==
472 472  
475 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
476 +
477 +**HMI Settings**
478 +
479 +(% class="table-bordered" %)
480 +|**Item**|**Settings**|**Note**
481 +|Protocol|Allen-Bradlley MicroLogix|
482 +|Connection|RS232|
483 +|Baud rate|19200|
484 +|Data bit|8|
485 +|Parity|None|
486 +|Stop bit|1|
487 +|PLC station No.|1|
488 +
489 +**Address List**
490 +
491 +(% class="table-bordered" %)
492 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
493 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
494 +|O|O d.d|0.0~~255.15|
495 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
496 +|S|S d.d|0.0~~255.15|
497 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
498 +|(% rowspan="9" %)Word|S|S d|0~~255|
499 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
500 +|TP|TP nnhh|0~~ffff
501 +|CS|CS nnhh|0~~ffff
502 +|CP|CP nnhh|0~~ffff
503 +|N|N nnhh|0~~ffff
504 +|C|C nnhh|0~~ffff
505 +|T|T nnhh|0~~ffff
506 +|R|R nnhh|0~~ffff
507 +
508 +**Cable Wiring**
509 +
510 +
511 +(% style="text-align:center" %)
512 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
513 +
473 473  == **FreeTag Ethernet/IP (CompactLogix)** ==
474 474  
475 475  Allen-Brandly CompactLogix
... ... @@ -527,46 +527,6 @@
527 527  (% style="text-align:center" %)
528 528  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
529 529  
530 -== **MicroLogix** ==
531 -
532 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
533 -
534 -**HMI Settings**
535 -
536 -(% class="table-bordered" %)
537 -|**Item**|**Settings**|**Note**
538 -|Protocol|Allen-Bradlley MicroLogix|
539 -|Connection|RS232|
540 -|Baud rate|19200|
541 -|Data bit|8|
542 -|Parity|None|
543 -|Stop bit|1|
544 -|PLC station No.|1|
545 -
546 -**Address List**
547 -
548 -(% class="table-bordered" %)
549 -|**Type**|**Device registers**|**Format**|**Range**|**Note**
550 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
551 -|O|O d.d|0.0~~255.15|
552 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
553 -|S|S d.d|0.0~~255.15|
554 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
555 -|(% rowspan="9" %)Word|S|S d|0~~255|
556 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
557 -|TP|TP nnhh|0~~ffff
558 -|CS|CS nnhh|0~~ffff
559 -|CP|CP nnhh|0~~ffff
560 -|N|N nnhh|0~~ffff
561 -|C|C nnhh|0~~ffff
562 -|T|T nnhh|0~~ffff
563 -|R|R nnhh|0~~ffff
564 -
565 -**Cable Wiring**
566 -
567 -(% style="text-align:center" %)
568 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
569 -
570 570  == **AB PLC address edit** ==
571 571  
572 572  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
... ... @@ -593,286 +593,8 @@
593 593  |(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
594 594  |(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
595 595  
596 -= **Barcode Scanner** =
597 += =
597 597  
598 -Supported: DELI 14880 barcode scanner
599 -
600 -**HMI Setting**
601 -
602 -(% class="table-bordered" %)
603 -|**Items**|**Settings**|**Note**
604 -|Protocol|Barcode Scanner|
605 -|Connection|USB|
606 -
607 -**Operating Procedures**
608 -
609 -Select [Barcode Scanner];
610 -
611 -(% style="text-align:center" %)
612 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
613 -
614 -Set address for receiving;
615 -
616 -Set correct length;
617 -
618 -(% style="text-align:center" %)
619 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
620 -
621 -**✎Note:**
622 -
623 -* The protocol uploads the information acquired by the USB scanner to the HMI;
624 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
625 -* Recommended model: DELI 14880 barcode scanner;
626 -
627 -= **Hitachi EHV Series (Ethernet)** =
628 -
629 -Supported series: Hitachi EHV series
630 -
631 -**HMI Settings**
632 -
633 -(% class="table-bordered" %)
634 -|**Items**|**Settings**|**Note**
635 -|Protocol|Hitachi EHV series|
636 -|Connection|Ethernet|
637 -|Port No.|3004~~3007|
638 -
639 -**Address List**
640 -
641 -(% class="table-bordered" %)
642 -|**Type**|**Register**|**Range**|**Format**|**Note**
643 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
644 -|M|0 - 7FFF.f (Hex)|M HHHH.h|
645 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
646 -H1H2H3H4 Module main number
647 -
648 -H1: Remote number
649 -
650 -H2: Unit number
651 -
652 -H3: Slot number
653 -
654 -H4: Word number of Module
655 -
656 -H Sub number of Module
657 -
658 -For example:X21.3
659 -
660 -Slot number 2
661 -
662 -Word number of module is 1
663 -
664 -Bit number of module is 3
665 -
666 -Remote number and unit number are 0
667 -)))
668 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
669 -|R|0 – FF.f (Hex)|R HH.h|
670 -|L|0 - 73FF.f (Hex)|L HHHH.h|
671 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
672 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
673 -H1H2H3H4 Module main number
674 -
675 -H1: Remote number
676 -
677 -H2: Unit number
678 -
679 -H3: Slot number
680 -
681 -H4: Word number of module
682 -
683 -For example:WX21
684 -
685 -Word number of module is 1
686 -
687 -Slot number is 2
688 -
689 -Remote number and unit number are 0
690 -)))
691 -|WY|0 – FFFF (Hex)|WY H1H2H3H4
692 -|WR|0 – FFFF (Hex)|WR HHHH|
693 -|WL|0 - 73FF (Hex)|WL HHHH|
694 -|TC|0 - 2559|TC DDDD|
695 -
696 -**Communication settings in HMI**
697 -
698 -Enable HMI Ethernet in [Project Settings];
699 -
700 -(% style="text-align:center" %)
701 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
702 -
703 -Set PLC IP in [Device IP] settings;
704 -
705 -(% style="text-align:center" %)
706 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
707 -
708 -**PLC Configuration**
709 -
710 -Connect with PLC, select[Online mode];
711 -
712 -(% style="text-align:center" %)
713 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
714 -
715 -Set IP address, it is the same LAN parameters with HMI;
716 -
717 -(% style="text-align:center" %)
718 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
719 -
720 -3) Save PLC communication parameter, and restart PLC
721 -
722 -**PLC Monitor Mode**
723 -
724 -Connect with PLC and choose to “online” mode
725 -
726 -(% style="text-align:center" %)
727 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
728 -
729 -Open I/O monitor sheet1
730 -
731 -(% style="text-align:center" %)
732 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
733 -
734 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
735 -
736 -(% style="text-align:center" %)
737 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
738 -
739 -Enter the register address, click OK to view the value of the register.
740 -
741 -(% style="text-align:center" %)
742 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
743 -
744 -(% style="text-align:center" %)
745 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
746 -
747 -**✎Note:**
748 -
749 -* Both word registers and bit registers support even continuous read/write functions;
750 -* The range of registers is based on the specific PLC type;
751 -
752 -**Cable Wiring**
753 -
754 -(% style="text-align:center" %)
755 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
756 -
757 -= **IEC60870-5 104 Client** =
758 -
759 -**HMI Setting**
760 -
761 -(% class="table-bordered" %)
762 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
763 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
764 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
765 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
766 -
767 -**Address List**
768 -
769 -(% class="table-bordered" %)
770 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
771 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
772 -|(% style="width:461px" %)SCNA|0~~16777215.7
773 -|(% style="width:461px" %)DPTB|0~~16777215.7
774 -|(% style="width:461px" %)DCNA|0~~16777215.7
775 -|(% style="width:461px" %)METF|0~~16777215.7
776 -|(% style="width:461px" %)SENC|0~~16777215.7
777 -|(% style="width:461px" %)SENA|0~~16777215.7
778 -|(% style="width:461px" %)MENA|0~~16777215.7
779 -|(% style="width:461px" %)METD|0~~16777215.7
780 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
781 -|(% style="width:461px" %)SCNA|0~~16777215
782 -|(% style="width:461px" %)DPTB|0~~16777215
783 -|(% style="width:461px" %)DCNA|0~~16777215
784 -|(% style="width:461px" %)SENA|0~~16777215
785 -|(% style="width:461px" %)MENA|0~~16777215
786 -|(% style="width:461px" %)METD|0~~16777215
787 -|(% style="width:461px" %)INRO|0~~16777215
788 -|(% style="width:461px" %)TIMESYN|0~~16777215
789 -|(% style="width:461px" %)TIMEZ|0~~16777215
790 -|(% style="width:461px" %)NTP|0~~16777215
791 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
792 -|(% style="width:461px" %)SENC|0~~16777215
793 -
794 -**Address Configuration**
795 -
796 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
797 -
798 -(% style="text-align:center" %)
799 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
800 -
801 -(% style="text-align:center" %)
802 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
803 -
804 -Extended tag name
805 -
806 -Address range for the extended tag.
807 -
808 -**Communication Settings**
809 -
810 -Enable HMI Ethernet in [Project Settings];
811 -
812 -(% style="text-align:center" %)
813 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
814 -
815 -Set PLC IP in [Device IP] settings;
816 -
817 -(% style="text-align:center" %)
818 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
819 -
820 -**Cable Wiring**
821 -
822 -(% style="text-align:center" %)
823 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
824 -
825 -= **LG XGK FEnet Ethernet** =
826 -
827 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
828 -
829 -**HMI Settings**
830 -
831 -(% class="table-bordered" %)
832 -|**Items**|**Settings**|**Note**
833 -|Protocol|LG XGK FEnet(Ethernet)|
834 -|Connection|Ethernet|
835 -|Port No.|2004|
836 -
837 -**Address List**
838 -
839 -(% class="table-bordered" %)
840 -|**Type**|**Register**|**Range**|**Format**|**Note**
841 -|(% rowspan="14" %)Word|P|0~~2047|P d|
842 -|M|0~~2047|M d|
843 -|K|0~~2047|K d|
844 -|F|0~~2047|F d|
845 -|T|0~~2047|T d|
846 -|C|0~~2047|C d|
847 -|Z|0~~127|Z d|
848 -|S|0~~127|S d|
849 -|L|0~~11263|L d|
850 -|N|0~~21503|N d|
851 -|D|0~~32767|D d|
852 -|R|0~~32767|R d|
853 -|ZR|0~~65535|ZR d|
854 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
855 -
856 -**✎Note:**
857 -
858 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
859 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
860 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
861 -
862 -**Communication settings in HMI**
863 -
864 -Enable HMI Ethernet in [Project Settings];
865 -
866 -(% style="text-align:center" %)
867 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
868 -
869 -Set PLC IP in [Device IP] settings;
870 -
871 -(% style="text-align:center" %)
872 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
873 -
874 -**Cable Wiring**
875 -
876 876  = **Mitsubishi** =
877 877  
878 878  == **FX1S, 1N, 2N Series** ==
... ... @@ -2646,8 +2646,6 @@
2646 2646  
2647 2647  **✎Note:** COM3 only available in PI8000/PI9000 series.
2648 2648  
2649 -= =
2650 -
2651 2651  = **Printer** =
2652 2652  
2653 2653  == **TSPL label printer** ==
... ... @@ -2848,3 +2848,283 @@
2848 2848  
2849 2849  (% style="text-align:center" %)
2850 2850  [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
2572 +
2573 += **Barcode Scanner** =
2574 +
2575 +Supported: DELI 14880 barcode scanner
2576 +
2577 +**HMI Setting**
2578 +
2579 +|**Items**|**Settings**|**Note**
2580 +|Protocol|Barcode Scanner|
2581 +|Connection|USB|
2582 +
2583 +**Operating Procedures**
2584 +
2585 +Select [Barcode Scanner];
2586 +
2587 +(% style="text-align:center" %)
2588 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
2589 +
2590 +Set address for receiving;
2591 +
2592 +Set correct length;
2593 +
2594 +(% style="text-align:center" %)
2595 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
2596 +
2597 +**✎Note:**
2598 +
2599 +* The protocol uploads the information acquired by the USB scanner to the HMI;
2600 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
2601 +* Recommended model: DELI 14880 barcode scanner;
2602 +
2603 +
2604 += **Hitachi EHV Series (Ethernet)** =
2605 +
2606 +Supported series: Hitachi EHV series
2607 +
2608 +**HMI Settings**
2609 +
2610 +(% class="table-bordered" %)
2611 +|**Items**|**Settings**|**Note**
2612 +|Protocol|Hitachi EHV series|
2613 +|Connection|Ethernet|
2614 +|Port No.|3004~~3007|
2615 +
2616 +**Address List**
2617 +
2618 +(% class="table-bordered" %)
2619 +|**Type**|**Register**|**Range**|**Format**|**Note**
2620 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
2621 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
2622 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
2623 +H1H2H3H4 Module main number
2624 +
2625 +H1: Remote number
2626 +
2627 +H2: Unit number
2628 +
2629 +H3: Slot number
2630 +
2631 +H4: Word number of Module
2632 +
2633 +H Sub number of Module
2634 +
2635 +For example:X21.3
2636 +
2637 +Slot number 2
2638 +
2639 +Word number of module is 1
2640 +
2641 +Bit number of module is 3
2642 +
2643 +Remote number and unit number are 0
2644 +)))
2645 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
2646 +|R|0 – FF.f (Hex)|R HH.h|
2647 +|L|0 - 73FF.f (Hex)|L HHHH.h|
2648 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
2649 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
2650 +H1H2H3H4 Module main number
2651 +
2652 +H1: Remote number
2653 +
2654 +H2: Unit number
2655 +
2656 +H3: Slot number
2657 +
2658 +H4: Word number of module
2659 +
2660 +For example:WX21
2661 +
2662 +Word number of module is 1
2663 +
2664 +Slot number is 2
2665 +
2666 +Remote number and unit number are 0
2667 +)))
2668 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
2669 +|WR|0 – FFFF (Hex)|WR HHHH|
2670 +|WL|0 - 73FF (Hex)|WL HHHH|
2671 +|TC|0 - 2559|TC DDDD|
2672 +
2673 +**Communication settings in HMI**
2674 +
2675 +Enable HMI Ethernet in [Project Settings];
2676 +
2677 +(% style="text-align:center" %)
2678 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2679 +
2680 +Set PLC IP in [Device IP] settings;
2681 +
2682 +(% style="text-align:center" %)
2683 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2684 +
2685 +**PLC Configuration**
2686 +
2687 +Connect with PLC, select[Online mode];
2688 +
2689 +(% style="text-align:center" %)
2690 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
2691 +
2692 +Set IP address, it is the same LAN parameters with HMI;
2693 +
2694 +(% style="text-align:center" %)
2695 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
2696 +
2697 +3) Save PLC communication parameter, and restart PLC
2698 +
2699 +**PLC Monitor Mode**
2700 +
2701 +Connect with PLC and choose to “online” mode
2702 +
2703 +(% style="text-align:center" %)
2704 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
2705 +
2706 +Open I/O monitor sheet1
2707 +
2708 +(% style="text-align:center" %)
2709 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
2710 +
2711 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
2712 +
2713 +(% style="text-align:center" %)
2714 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
2715 +
2716 +Enter the register address, click OK to view the value of the register.
2717 +
2718 +(% style="text-align:center" %)
2719 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2720 +
2721 +(% style="text-align:center" %)
2722 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2723 +
2724 +**✎Note:**
2725 +
2726 +* Both word registers and bit registers support even continuous read/write functions;
2727 +* The range of registers is based on the specific PLC type;
2728 +
2729 +**Cable Wiring**
2730 +
2731 +(% style="text-align:center" %)
2732 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2733 +
2734 += **IEC60870-5 104 Client** =
2735 +
2736 +**HMI Setting**
2737 +
2738 +(% class="table-bordered" %)
2739 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
2740 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
2741 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
2742 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
2743 +
2744 +**Address List**
2745 +
2746 +(% class="table-bordered" %)
2747 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
2748 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
2749 +|(% style="width:461px" %)SCNA|0~~16777215.7
2750 +|(% style="width:461px" %)DPTB|0~~16777215.7
2751 +|(% style="width:461px" %)DCNA|0~~16777215.7
2752 +|(% style="width:461px" %)METF|0~~16777215.7
2753 +|(% style="width:461px" %)SENC|0~~16777215.7
2754 +|(% style="width:461px" %)SENA|0~~16777215.7
2755 +|(% style="width:461px" %)MENA|0~~16777215.7
2756 +|(% style="width:461px" %)METD|0~~16777215.7
2757 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
2758 +|(% style="width:461px" %)SCNA|0~~16777215
2759 +|(% style="width:461px" %)DPTB|0~~16777215
2760 +|(% style="width:461px" %)DCNA|0~~16777215
2761 +|(% style="width:461px" %)SENA|0~~16777215
2762 +|(% style="width:461px" %)MENA|0~~16777215
2763 +|(% style="width:461px" %)METD|0~~16777215
2764 +|(% style="width:461px" %)INRO|0~~16777215
2765 +|(% style="width:461px" %)TIMESYN|0~~16777215
2766 +|(% style="width:461px" %)TIMEZ|0~~16777215
2767 +|(% style="width:461px" %)NTP|0~~16777215
2768 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
2769 +|(% style="width:461px" %)SENC|0~~16777215
2770 +
2771 +**Address Configuration**
2772 +
2773 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
2774 +
2775 +(% style="text-align:center" %)
2776 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
2777 +
2778 +(% style="text-align:center" %)
2779 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
2780 +
2781 +Extended tag name
2782 +
2783 +Address range for the extended tag.
2784 +
2785 +**Communication Settings**
2786 +
2787 +Enable HMI Ethernet in [Project Settings];
2788 +
2789 +(% style="text-align:center" %)
2790 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2791 +
2792 +Set PLC IP in [Device IP] settings;
2793 +
2794 +(% style="text-align:center" %)
2795 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
2796 +
2797 +**Cable Wiring**
2798 +
2799 +(% style="text-align:center" %)
2800 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2801 +
2802 += **LG XGK FEnet Ethernet** =
2803 +
2804 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
2805 +
2806 +**HMI Settings**
2807 +
2808 +(% class="table-bordered" %)
2809 +|**Items**|**Settings**|**Note**
2810 +|Protocol|LG XGK FEnet(Ethernet)|
2811 +|Connection|Ethernet|
2812 +|Port No.|2004|
2813 +
2814 +**Address List**
2815 +
2816 +(% class="table-bordered" %)
2817 +|**Type**|**Register**|**Range**|**Format**|**Note**
2818 +|(% rowspan="14" %)Word|P|0~~2047|P d|
2819 +|M|0~~2047|M d|
2820 +|K|0~~2047|K d|
2821 +|F|0~~2047|F d|
2822 +|T|0~~2047|T d|
2823 +|C|0~~2047|C d|
2824 +|Z|0~~127|Z d|
2825 +|S|0~~127|S d|
2826 +|L|0~~11263|L d|
2827 +|N|0~~21503|N d|
2828 +|D|0~~32767|D d|
2829 +|R|0~~32767|R d|
2830 +|ZR|0~~65535|ZR d|
2831 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
2832 +
2833 +**✎Note:**
2834 +
2835 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
2836 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
2837 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
2838 +
2839 +**Communication settings in HMI**
2840 +
2841 +Enable HMI Ethernet in [Project Settings];
2842 +
2843 +(% style="text-align:center" %)
2844 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2845 +
2846 +Set PLC IP in [Device IP] settings;
2847 +
2848 +(% style="text-align:center" %)
2849 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
2850 +
2851 +**Cable Wiring**