Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -87,6 +87,7 @@ 87 87 88 88 = Create communication with WECON PLC = 89 89 90 +== **LX3V Serial Protocol** == 90 90 91 91 Supported series: WECON LX2V/ LX2E/ LX3V/LX3VP/LX3VE/LX3VM 92 92 ... ... @@ -140,7 +140,8 @@ 140 140 141 141 [[https:~~/~~/drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing>>url:https://drive.google.com/drive/folders/13rgso7oUlatZQN_SNEcJCcN4toEdDPoP?usp=sharing]] 142 142 143 -== HMI settings == 144 +(% class="wikigeneratedid" id="HHMIsettings" %) 145 +**HMI settings** 144 144 145 145 **Download PIStudio Software** 146 146 ... ... @@ -229,7 +229,8 @@ 229 229 * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]] 230 230 * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]] 231 231 232 -== PLC settings == 234 +(% class="wikigeneratedid" id="HPLCsettings" %) 235 +**PLC settings** 233 233 234 234 **Download PLC Software** 235 235 ... ... @@ -314,7 +314,7 @@ 314 314 (% style="text-align:center" %) 315 315 [[image:image-20220819105928-9.png||height="229" width="669"]] 316 316 317 -= ** HMI and WeconLX5Vserialcommunication** =320 +== **LX5V Serial Protocol** == 318 318 319 319 This example introduces the establishment of serial port communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 320 320 ... ... @@ -392,11 +392,10 @@ 392 392 393 393 The above are all the steps for establishing serial port communication between Wecon HMI with LX5V PLC. 394 394 395 -== ** HMI and WeconLX5V-N Ethernetcommunication** ==398 +== **LX5V-N Ethernet protocol** == 396 396 397 397 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 398 398 399 - 400 400 **Software configuration of PLC** 401 401 402 402 **1)PLC programming software** ... ... @@ -466,69 +466,10 @@ 466 466 467 467 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 468 468 469 -= = 471 += Create communication with **Rockwell PLC** = 470 470 471 -= ** Allen-Bradley** =473 +== **MicroLogix Protocol** == 472 472 473 -== **FreeTag Ethernet/IP (CompactLogix)** == 474 - 475 -Allen-Brandly CompactLogix 476 - 477 -**HMI Settings** 478 - 479 -(% class="table-bordered" %) 480 -|**Items**|**Settings**|**Note** 481 -|Protocol|Allen-Brandley FreeTag Ethernet/IP (CompactLogix)| 482 -|Connection|Ethernet| 483 -|Port No.|44818| 484 - 485 -**PLC Setting** 486 - 487 -Create new tags 488 - 489 -(% style="text-align:center" %) 490 -[[image:12.PLC Protocol_html_a748a27dcf7f1124.png||data-xwiki-image-style-alignment="center" height="411" width="700" class="img-thumbnail"]] 491 - 492 -Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments]) 493 - 494 -(% style="text-align:center" %) 495 -[[image:12.PLC Protocol_html_151379170bb8ff3e.png||data-xwiki-image-style-alignment="center" height="352" width="700" class="img-thumbnail"]] 496 - 497 -Import labels, please open [Communication] window and click [Import label]; 498 - 499 -Select csv file, all tags will be displayed as belows; 500 - 501 -(% style="text-align:center" %) 502 -[[image:12.PLC Protocol_html_af192e54dee96f38.png||data-xwiki-image-style-alignment="center" height="586" width="700" class="img-thumbnail"]] 503 - 504 -**✎Note:** 505 - 506 -Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format. 507 - 508 -(% style="text-align:center" %) 509 -[[image:12.PLC Protocol_html_33df1d63ebe53726.png||data-xwiki-image-style-alignment="center" height="206" width="700" class="img-thumbnail"]] 510 - 511 -The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting. 512 - 513 -**Communication settings in HMI** 514 - 515 -Enable HMI Ethernet in [Project Settings]; 516 - 517 -(% style="text-align:center" %) 518 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="106" width="400" class="img-thumbnail"]] 519 - 520 -Set PLC IP in [Device IP] settings; 521 - 522 -(% style="text-align:center" %) 523 -[[image:12.PLC Protocol_html_27870d373581892e.png||data-xwiki-image-style-alignment="center" height="206" width="600" class="img-thumbnail"]] 524 - 525 -**Cable Wiring** 526 - 527 -(% style="text-align:center" %) 528 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 529 - 530 -== **MicroLogix** == 531 - 532 532 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 533 533 534 534 **HMI Settings** ... ... @@ -564,315 +564,95 @@ 564 564 565 565 **Cable Wiring** 566 566 510 + 567 567 (% style="text-align:center" %) 568 568 [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 569 569 570 -== ** AB PLC addressedit** ==514 +== **FreeTag Ethernet/IP (CompactLogix)** == 571 571 572 - The operational address is determined by the connection ofAllen-BradleyPLCtoHMI. For extensionmodules or other specialconditions, refer to allen-Bradley PLC instruction manual. The followings an example of allen-bradley MicroLogix1200.516 +Allen-Brandly CompactLogix 573 573 574 -* **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal). 575 -* **Bit address B:** The address ranges from 000.0 to fff.15. The first f from left to right represents the block number (hexadecimal); The second and third f from left to right represent the word address (hexadecimal). The value 0 to 15 after the decimal point reprensents the sub address (decimal). 576 -* **Word address S:** The word address ranges from 0 to 255 (decimal). 577 -* **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal). 578 - 579 -**✎Note: **Register address TP, CS, CP, N, F and TS address edit are same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table. 580 - 581 -|(% style="width:393px" %)**PLC bit address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range** 582 -|(% style="width:393px" %)I|(% style="width:350px" %)dd.dd|(% style="width:333px" %)I 0.0 ~~ 255.15 583 -|(% style="width:393px" %)O|(% style="width:350px" %)dd.dd|(% style="width:333px" %)O 0.0 ~~ 255.15 584 -|(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15 585 -|(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15 586 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15 587 -|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range** 588 -|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255 589 -|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF 590 -|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF 591 -|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF 592 -|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF 593 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF 594 -|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF 595 - 596 -= **Barcode Scanner** = 597 - 598 -Supported: DELI 14880 barcode scanner 599 - 600 -**HMI Setting** 601 - 602 -(% class="table-bordered" %) 603 -|**Items**|**Settings**|**Note** 604 -|Protocol|Barcode Scanner| 605 -|Connection|USB| 606 - 607 -**Operating Procedures** 608 - 609 -Select [Barcode Scanner]; 610 - 611 -(% style="text-align:center" %) 612 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 613 - 614 -Set address for receiving; 615 - 616 -Set correct length; 617 - 618 -(% style="text-align:center" %) 619 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 620 - 621 -**✎Note:** 622 - 623 -* The protocol uploads the information acquired by the USB scanner to the HMI; 624 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 625 -* Recommended model: DELI 14880 barcode scanner; 626 - 627 -= **Hitachi EHV Series (Ethernet)** = 628 - 629 -Supported series: Hitachi EHV series 630 - 631 631 **HMI Settings** 632 632 633 633 (% class="table-bordered" %) 634 634 |**Items**|**Settings**|**Note** 635 -|Protocol| HitachiEHVseries|522 +|Protocol|Allen-Brandley FreeTag Ethernet/IP (CompactLogix)| 636 636 |Connection|Ethernet| 637 -|Port No.| 3004~~3007|524 +|Port No.|44818| 638 638 639 -** AddressList**526 +**PLC Setting** 640 640 641 -(% class="table-bordered" %) 642 -|**Type**|**Register**|**Range**|**Format**|**Note** 643 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 644 -|M|0 - 7FFF.f (Hex)|M HHHH.h| 645 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 646 -H1H2H3H4 Module main number 528 +Create new tags 647 647 648 -H1: Remote number 649 - 650 -H2: Unit number 651 - 652 -H3: Slot number 653 - 654 -H4: Word number of Module 655 - 656 -H Sub number of Module 657 - 658 -For example:X21.3 659 - 660 -Slot number 2 661 - 662 -Word number of module is 1 663 - 664 -Bit number of module is 3 665 - 666 -Remote number and unit number are 0 667 -))) 668 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 669 -|R|0 – FF.f (Hex)|R HH.h| 670 -|L|0 - 73FF.f (Hex)|L HHHH.h| 671 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 672 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 673 -H1H2H3H4 Module main number 674 - 675 -H1: Remote number 676 - 677 -H2: Unit number 678 - 679 -H3: Slot number 680 - 681 -H4: Word number of module 682 - 683 -For example:WX21 684 - 685 -Word number of module is 1 686 - 687 -Slot number is 2 688 - 689 -Remote number and unit number are 0 690 -))) 691 -|WY|0 – FFFF (Hex)|WY H1H2H3H4 692 -|WR|0 – FFFF (Hex)|WR HHHH| 693 -|WL|0 - 73FF (Hex)|WL HHHH| 694 -|TC|0 - 2559|TC DDDD| 695 - 696 -**Communication settings in HMI** 697 - 698 -Enable HMI Ethernet in [Project Settings]; 699 - 700 700 (% style="text-align:center" %) 701 -[[image:12.PLC Protocol_html_4 3b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]531 +[[image:12.PLC Protocol_html_a748a27dcf7f1124.png||data-xwiki-image-style-alignment="center" height="411" width="700" class="img-thumbnail"]] 702 702 703 - SetPLCIPin[DeviceIP]settings;533 +Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments]) 704 704 705 705 (% style="text-align:center" %) 706 -[[image:12.PLC Protocol_html_ d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]536 +[[image:12.PLC Protocol_html_151379170bb8ff3e.png||data-xwiki-image-style-alignment="center" height="352" width="700" class="img-thumbnail"]] 707 707 708 - **PLCConfiguration**538 +Import labels, please open [Communication] window and click [Import label]; 709 709 710 - ConnectwithPLC,select[Onlinemode];540 +Select csv file, all tags will be displayed as belows; 711 711 712 712 (% style="text-align:center" %) 713 -[[image:12.PLC Protocol_html_ 8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]543 +[[image:12.PLC Protocol_html_af192e54dee96f38.png||data-xwiki-image-style-alignment="center" height="586" width="700" class="img-thumbnail"]] 714 714 715 -Set IP address, it is the same LAN parameters with HMI; 716 - 717 -(% style="text-align:center" %) 718 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 719 - 720 -3) Save PLC communication parameter, and restart PLC 721 - 722 -**PLC Monitor Mode** 723 - 724 -Connect with PLC and choose to “online” mode 725 - 726 -(% style="text-align:center" %) 727 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 728 - 729 -Open I/O monitor sheet1 730 - 731 -(% style="text-align:center" %) 732 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 733 - 734 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 735 - 736 -(% style="text-align:center" %) 737 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 738 - 739 -Enter the register address, click OK to view the value of the register. 740 - 741 -(% style="text-align:center" %) 742 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 743 - 744 -(% style="text-align:center" %) 745 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 746 - 747 747 **✎Note:** 748 748 749 -* Both word registers and bit registers support even continuous read/write functions; 750 -* The range of registers is based on the specific PLC type; 547 +Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format. 751 751 752 -**Cable Wiring** 753 - 754 754 (% style="text-align:center" %) 755 -[[image:12.PLC Protocol_html_ 2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]550 +[[image:12.PLC Protocol_html_33df1d63ebe53726.png||data-xwiki-image-style-alignment="center" height="206" width="700" class="img-thumbnail"]] 756 756 757 - =**IEC60870-5104Client**=552 +The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting. 758 758 759 -** HMISetting**554 +**Communication settings in HMI** 760 760 761 -(% class="table-bordered" %) 762 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 763 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 764 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 765 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 766 - 767 -**Address List** 768 - 769 -(% class="table-bordered" %) 770 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 771 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 772 -|(% style="width:461px" %)SCNA|0~~16777215.7 773 -|(% style="width:461px" %)DPTB|0~~16777215.7 774 -|(% style="width:461px" %)DCNA|0~~16777215.7 775 -|(% style="width:461px" %)METF|0~~16777215.7 776 -|(% style="width:461px" %)SENC|0~~16777215.7 777 -|(% style="width:461px" %)SENA|0~~16777215.7 778 -|(% style="width:461px" %)MENA|0~~16777215.7 779 -|(% style="width:461px" %)METD|0~~16777215.7 780 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 781 -|(% style="width:461px" %)SCNA|0~~16777215 782 -|(% style="width:461px" %)DPTB|0~~16777215 783 -|(% style="width:461px" %)DCNA|0~~16777215 784 -|(% style="width:461px" %)SENA|0~~16777215 785 -|(% style="width:461px" %)MENA|0~~16777215 786 -|(% style="width:461px" %)METD|0~~16777215 787 -|(% style="width:461px" %)INRO|0~~16777215 788 -|(% style="width:461px" %)TIMESYN|0~~16777215 789 -|(% style="width:461px" %)TIMEZ|0~~16777215 790 -|(% style="width:461px" %)NTP|0~~16777215 791 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 792 -|(% style="width:461px" %)SENC|0~~16777215 793 - 794 -**Address Configuration** 795 - 796 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 797 - 798 -(% style="text-align:center" %) 799 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 800 - 801 -(% style="text-align:center" %) 802 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 803 - 804 -Extended tag name 805 - 806 -Address range for the extended tag. 807 - 808 -**Communication Settings** 809 - 810 810 Enable HMI Ethernet in [Project Settings]; 811 811 812 812 (% style="text-align:center" %) 813 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="10 7" width="405" class="img-thumbnail"]]559 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="106" width="400" class="img-thumbnail"]] 814 814 815 815 Set PLC IP in [Device IP] settings; 816 816 817 817 (% style="text-align:center" %) 818 -[[image:12.PLC Protocol_html_ f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]564 +[[image:12.PLC Protocol_html_27870d373581892e.png||data-xwiki-image-style-alignment="center" height="206" width="600" class="img-thumbnail"]] 819 819 820 820 **Cable Wiring** 821 821 822 822 (% style="text-align:center" %) 823 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="40 1" class="img-thumbnail"]]569 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 824 824 825 -= **L GXGK FEnetEthernet** =571 +== **AB PLC address edit** == 826 826 827 - SupportedSeries:LSXGTseriesXGKCPU withXGL-EFMTEthernet module573 +The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. 828 828 829 -**HMI Settings** 575 +* **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal). 576 +* **Bit address B:** The address ranges from 000.0 to fff.15. The first f from left to right represents the block number (hexadecimal); The second and third f from left to right represent the word address (hexadecimal). The value 0 to 15 after the decimal point reprensents the sub address (decimal). 577 +* **Word address S:** The word address ranges from 0 to 255 (decimal). 578 +* **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal). 830 830 831 -(% class="table-bordered" %) 832 -|**Items**|**Settings**|**Note** 833 -|Protocol|LG XGK FEnet(Ethernet)| 834 -|Connection|Ethernet| 835 -|Port No.|2004| 580 +**✎Note: **Register address TP, CS, CP, N, F and TS address edit are same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table. 836 836 837 -**Address List** 582 +|(% style="width:393px" %)**PLC bit address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range** 583 +|(% style="width:393px" %)I|(% style="width:350px" %)dd.dd|(% style="width:333px" %)I 0.0 ~~ 255.15 584 +|(% style="width:393px" %)O|(% style="width:350px" %)dd.dd|(% style="width:333px" %)O 0.0 ~~ 255.15 585 +|(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15 586 +|(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15 587 +|(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15 588 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 589 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 590 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 591 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 592 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 593 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 594 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 595 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 838 838 839 -(% class="table-bordered" %) 840 -|**Type**|**Register**|**Range**|**Format**|**Note** 841 -|(% rowspan="14" %)Word|P|0~~2047|P d| 842 -|M|0~~2047|M d| 843 -|K|0~~2047|K d| 844 -|F|0~~2047|F d| 845 -|T|0~~2047|T d| 846 -|C|0~~2047|C d| 847 -|Z|0~~127|Z d| 848 -|S|0~~127|S d| 849 -|L|0~~11263|L d| 850 -|N|0~~21503|N d| 851 -|D|0~~32767|D d| 852 -|R|0~~32767|R d| 853 -|ZR|0~~65535|ZR d| 854 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 597 += = 855 855 856 -**✎Note:** 857 - 858 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 859 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 860 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 861 - 862 -**Communication settings in HMI** 863 - 864 -Enable HMI Ethernet in [Project Settings]; 865 - 866 -(% style="text-align:center" %) 867 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 868 - 869 -Set PLC IP in [Device IP] settings; 870 - 871 -(% style="text-align:center" %) 872 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 873 - 874 -**Cable Wiring** 875 - 876 876 = **Mitsubishi** = 877 877 878 878 == **FX1S, 1N, 2N Series** == ... ... @@ -2646,8 +2646,6 @@ 2646 2646 2647 2647 **✎Note:** COM3 only available in PI8000/PI9000 series. 2648 2648 2649 -= = 2650 - 2651 2651 = **Printer** = 2652 2652 2653 2653 == **TSPL label printer** == ... ... @@ -2848,3 +2848,282 @@ 2848 2848 2849 2849 (% style="text-align:center" %) 2850 2850 [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]] 2572 + 2573 += **Barcode Scanner** = 2574 + 2575 +Supported: DELI 14880 barcode scanner 2576 + 2577 +**HMI Setting** 2578 + 2579 +|**Items**|**Settings**|**Note** 2580 +|Protocol|Barcode Scanner| 2581 +|Connection|USB| 2582 + 2583 +**Operating Procedures** 2584 + 2585 +Select [Barcode Scanner]; 2586 + 2587 +(% style="text-align:center" %) 2588 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 2589 + 2590 +Set address for receiving; 2591 + 2592 +Set correct length; 2593 + 2594 +(% style="text-align:center" %) 2595 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 2596 + 2597 +**✎Note:** 2598 + 2599 +* The protocol uploads the information acquired by the USB scanner to the HMI; 2600 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 2601 +* Recommended model: DELI 14880 barcode scanner; 2602 + 2603 += **Hitachi EHV Series (Ethernet)** = 2604 + 2605 +Supported series: Hitachi EHV series 2606 + 2607 +**HMI Settings** 2608 + 2609 +(% class="table-bordered" %) 2610 +|**Items**|**Settings**|**Note** 2611 +|Protocol|Hitachi EHV series| 2612 +|Connection|Ethernet| 2613 +|Port No.|3004~~3007| 2614 + 2615 +**Address List** 2616 + 2617 +(% class="table-bordered" %) 2618 +|**Type**|**Register**|**Range**|**Format**|**Note** 2619 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 2620 +|M|0 - 7FFF.f (Hex)|M HHHH.h| 2621 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 2622 +H1H2H3H4 Module main number 2623 + 2624 +H1: Remote number 2625 + 2626 +H2: Unit number 2627 + 2628 +H3: Slot number 2629 + 2630 +H4: Word number of Module 2631 + 2632 +H Sub number of Module 2633 + 2634 +For example:X21.3 2635 + 2636 +Slot number 2 2637 + 2638 +Word number of module is 1 2639 + 2640 +Bit number of module is 3 2641 + 2642 +Remote number and unit number are 0 2643 +))) 2644 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 2645 +|R|0 – FF.f (Hex)|R HH.h| 2646 +|L|0 - 73FF.f (Hex)|L HHHH.h| 2647 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 2648 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 2649 +H1H2H3H4 Module main number 2650 + 2651 +H1: Remote number 2652 + 2653 +H2: Unit number 2654 + 2655 +H3: Slot number 2656 + 2657 +H4: Word number of module 2658 + 2659 +For example:WX21 2660 + 2661 +Word number of module is 1 2662 + 2663 +Slot number is 2 2664 + 2665 +Remote number and unit number are 0 2666 +))) 2667 +|WY|0 – FFFF (Hex)|WY H1H2H3H4 2668 +|WR|0 – FFFF (Hex)|WR HHHH| 2669 +|WL|0 - 73FF (Hex)|WL HHHH| 2670 +|TC|0 - 2559|TC DDDD| 2671 + 2672 +**Communication settings in HMI** 2673 + 2674 +Enable HMI Ethernet in [Project Settings]; 2675 + 2676 +(% style="text-align:center" %) 2677 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2678 + 2679 +Set PLC IP in [Device IP] settings; 2680 + 2681 +(% style="text-align:center" %) 2682 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 2683 + 2684 +**PLC Configuration** 2685 + 2686 +Connect with PLC, select[Online mode]; 2687 + 2688 +(% style="text-align:center" %) 2689 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 2690 + 2691 +Set IP address, it is the same LAN parameters with HMI; 2692 + 2693 +(% style="text-align:center" %) 2694 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 2695 + 2696 +3) Save PLC communication parameter, and restart PLC 2697 + 2698 +**PLC Monitor Mode** 2699 + 2700 +Connect with PLC and choose to “online” mode 2701 + 2702 +(% style="text-align:center" %) 2703 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 2704 + 2705 +Open I/O monitor sheet1 2706 + 2707 +(% style="text-align:center" %) 2708 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 2709 + 2710 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 2711 + 2712 +(% style="text-align:center" %) 2713 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 2714 + 2715 +Enter the register address, click OK to view the value of the register. 2716 + 2717 +(% style="text-align:center" %) 2718 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2719 + 2720 +(% style="text-align:center" %) 2721 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2722 + 2723 +**✎Note:** 2724 + 2725 +* Both word registers and bit registers support even continuous read/write functions; 2726 +* The range of registers is based on the specific PLC type; 2727 + 2728 +**Cable Wiring** 2729 + 2730 +(% style="text-align:center" %) 2731 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2732 + 2733 += **IEC60870-5 104 Client** = 2734 + 2735 +**HMI Setting** 2736 + 2737 +(% class="table-bordered" %) 2738 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 2739 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 2740 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 2741 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 2742 + 2743 +**Address List** 2744 + 2745 +(% class="table-bordered" %) 2746 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 2747 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 2748 +|(% style="width:461px" %)SCNA|0~~16777215.7 2749 +|(% style="width:461px" %)DPTB|0~~16777215.7 2750 +|(% style="width:461px" %)DCNA|0~~16777215.7 2751 +|(% style="width:461px" %)METF|0~~16777215.7 2752 +|(% style="width:461px" %)SENC|0~~16777215.7 2753 +|(% style="width:461px" %)SENA|0~~16777215.7 2754 +|(% style="width:461px" %)MENA|0~~16777215.7 2755 +|(% style="width:461px" %)METD|0~~16777215.7 2756 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 2757 +|(% style="width:461px" %)SCNA|0~~16777215 2758 +|(% style="width:461px" %)DPTB|0~~16777215 2759 +|(% style="width:461px" %)DCNA|0~~16777215 2760 +|(% style="width:461px" %)SENA|0~~16777215 2761 +|(% style="width:461px" %)MENA|0~~16777215 2762 +|(% style="width:461px" %)METD|0~~16777215 2763 +|(% style="width:461px" %)INRO|0~~16777215 2764 +|(% style="width:461px" %)TIMESYN|0~~16777215 2765 +|(% style="width:461px" %)TIMEZ|0~~16777215 2766 +|(% style="width:461px" %)NTP|0~~16777215 2767 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 2768 +|(% style="width:461px" %)SENC|0~~16777215 2769 + 2770 +**Address Configuration** 2771 + 2772 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 2773 + 2774 +(% style="text-align:center" %) 2775 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 2776 + 2777 +(% style="text-align:center" %) 2778 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 2779 + 2780 +Extended tag name 2781 + 2782 +Address range for the extended tag. 2783 + 2784 +**Communication Settings** 2785 + 2786 +Enable HMI Ethernet in [Project Settings]; 2787 + 2788 +(% style="text-align:center" %) 2789 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2790 + 2791 +Set PLC IP in [Device IP] settings; 2792 + 2793 +(% style="text-align:center" %) 2794 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 2795 + 2796 +**Cable Wiring** 2797 + 2798 +(% style="text-align:center" %) 2799 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2800 + 2801 += **LG XGK FEnet Ethernet** = 2802 + 2803 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2804 + 2805 +**HMI Settings** 2806 + 2807 +(% class="table-bordered" %) 2808 +|**Items**|**Settings**|**Note** 2809 +|Protocol|LG XGK FEnet(Ethernet)| 2810 +|Connection|Ethernet| 2811 +|Port No.|2004| 2812 + 2813 +**Address List** 2814 + 2815 +(% class="table-bordered" %) 2816 +|**Type**|**Register**|**Range**|**Format**|**Note** 2817 +|(% rowspan="14" %)Word|P|0~~2047|P d| 2818 +|M|0~~2047|M d| 2819 +|K|0~~2047|K d| 2820 +|F|0~~2047|F d| 2821 +|T|0~~2047|T d| 2822 +|C|0~~2047|C d| 2823 +|Z|0~~127|Z d| 2824 +|S|0~~127|S d| 2825 +|L|0~~11263|L d| 2826 +|N|0~~21503|N d| 2827 +|D|0~~32767|D d| 2828 +|R|0~~32767|R d| 2829 +|ZR|0~~65535|ZR d| 2830 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 2831 + 2832 +**✎Note:** 2833 + 2834 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 2835 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 2836 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 2837 + 2838 +**Communication settings in HMI** 2839 + 2840 +Enable HMI Ethernet in [Project Settings]; 2841 + 2842 +(% style="text-align:center" %) 2843 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2844 + 2845 +Set PLC IP in [Device IP] settings; 2846 + 2847 +(% style="text-align:center" %) 2848 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 2849 + 2850 +**Cable Wiring**