Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -231,7 +231,8 @@ 231 231 * HMI setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/>>https://docs.we-con.com.cn/bin/view/PIStudio/12.PLC%20protocols/]] 232 232 * PLC setting: [[https:~~/~~/docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/>>https://docs.we-con.com.cn/bin/view/PLC%20Editor/8.1.%09Communication/]] 233 233 234 -== PLC settings == 234 +(% class="wikigeneratedid" id="HPLCsettings" %) 235 +**PLC settings** 235 235 236 236 **Download PLC Software** 237 237 ... ... @@ -398,7 +398,6 @@ 398 398 399 399 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 400 400 401 - 402 402 **Software configuration of PLC** 403 403 404 404 **1)PLC programming software** ... ... @@ -468,10 +468,49 @@ 468 468 469 469 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 470 470 471 -= = 471 += Create communication with **Rockwell PLC** = 472 472 473 -= ** Allen-Bradley** =473 +== **MicroLogix Protocol** == 474 474 475 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 476 + 477 +**HMI Settings** 478 + 479 +(% class="table-bordered" %) 480 +|**Item**|**Settings**|**Note** 481 +|Protocol|Allen-Bradlley MicroLogix| 482 +|Connection|RS232| 483 +|Baud rate|19200| 484 +|Data bit|8| 485 +|Parity|None| 486 +|Stop bit|1| 487 +|PLC station No.|1| 488 + 489 +**Address List** 490 + 491 +(% class="table-bordered" %) 492 +|**Type**|**Device registers**|**Format**|**Range**|**Note** 493 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 494 +|O|O d.d|0.0~~255.15| 495 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 496 +|S|S d.d|0.0~~255.15| 497 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 498 +|(% rowspan="9" %)Word|S|S d|0~~255| 499 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 500 +|TP|TP nnhh|0~~ffff 501 +|CS|CS nnhh|0~~ffff 502 +|CP|CP nnhh|0~~ffff 503 +|N|N nnhh|0~~ffff 504 +|C|C nnhh|0~~ffff 505 +|T|T nnhh|0~~ffff 506 +|R|R nnhh|0~~ffff 507 + 508 +**Cable Wiring** 509 + 510 + 511 +(% style="text-align:center" %) 512 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 513 + 475 475 == **FreeTag Ethernet/IP (CompactLogix)** == 476 476 477 477 Allen-Brandly CompactLogix ... ... @@ -529,46 +529,6 @@ 529 529 (% style="text-align:center" %) 530 530 [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 531 531 532 -== **MicroLogix** == 533 - 534 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 535 - 536 -**HMI Settings** 537 - 538 -(% class="table-bordered" %) 539 -|**Item**|**Settings**|**Note** 540 -|Protocol|Allen-Bradlley MicroLogix| 541 -|Connection|RS232| 542 -|Baud rate|19200| 543 -|Data bit|8| 544 -|Parity|None| 545 -|Stop bit|1| 546 -|PLC station No.|1| 547 - 548 -**Address List** 549 - 550 -(% class="table-bordered" %) 551 -|**Type**|**Device registers**|**Format**|**Range**|**Note** 552 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15| 553 -|O|O d.d|0.0~~255.15| 554 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex) 555 -|S|S d.d|0.0~~255.15| 556 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex) 557 -|(% rowspan="9" %)Word|S|S d|0~~255| 558 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex) 559 -|TP|TP nnhh|0~~ffff 560 -|CS|CS nnhh|0~~ffff 561 -|CP|CP nnhh|0~~ffff 562 -|N|N nnhh|0~~ffff 563 -|C|C nnhh|0~~ffff 564 -|T|T nnhh|0~~ffff 565 -|R|R nnhh|0~~ffff 566 - 567 -**Cable Wiring** 568 - 569 -(% style="text-align:center" %) 570 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 571 - 572 572 == **AB PLC address edit** == 573 573 574 574 The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. ... ... @@ -595,286 +595,8 @@ 595 595 |(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF 596 596 |(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF 597 597 598 -= **BarcodeScanner**=597 += = 599 599 600 -Supported: DELI 14880 barcode scanner 601 - 602 -**HMI Setting** 603 - 604 -(% class="table-bordered" %) 605 -|**Items**|**Settings**|**Note** 606 -|Protocol|Barcode Scanner| 607 -|Connection|USB| 608 - 609 -**Operating Procedures** 610 - 611 -Select [Barcode Scanner]; 612 - 613 -(% style="text-align:center" %) 614 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 615 - 616 -Set address for receiving; 617 - 618 -Set correct length; 619 - 620 -(% style="text-align:center" %) 621 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 622 - 623 -**✎Note:** 624 - 625 -* The protocol uploads the information acquired by the USB scanner to the HMI; 626 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 627 -* Recommended model: DELI 14880 barcode scanner; 628 - 629 -= **Hitachi EHV Series (Ethernet)** = 630 - 631 -Supported series: Hitachi EHV series 632 - 633 -**HMI Settings** 634 - 635 -(% class="table-bordered" %) 636 -|**Items**|**Settings**|**Note** 637 -|Protocol|Hitachi EHV series| 638 -|Connection|Ethernet| 639 -|Port No.|3004~~3007| 640 - 641 -**Address List** 642 - 643 -(% class="table-bordered" %) 644 -|**Type**|**Register**|**Range**|**Format**|**Note** 645 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 646 -|M|0 - 7FFF.f (Hex)|M HHHH.h| 647 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 648 -H1H2H3H4 Module main number 649 - 650 -H1: Remote number 651 - 652 -H2: Unit number 653 - 654 -H3: Slot number 655 - 656 -H4: Word number of Module 657 - 658 -H Sub number of Module 659 - 660 -For example:X21.3 661 - 662 -Slot number 2 663 - 664 -Word number of module is 1 665 - 666 -Bit number of module is 3 667 - 668 -Remote number and unit number are 0 669 -))) 670 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 671 -|R|0 – FF.f (Hex)|R HH.h| 672 -|L|0 - 73FF.f (Hex)|L HHHH.h| 673 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 674 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 675 -H1H2H3H4 Module main number 676 - 677 -H1: Remote number 678 - 679 -H2: Unit number 680 - 681 -H3: Slot number 682 - 683 -H4: Word number of module 684 - 685 -For example:WX21 686 - 687 -Word number of module is 1 688 - 689 -Slot number is 2 690 - 691 -Remote number and unit number are 0 692 -))) 693 -|WY|0 – FFFF (Hex)|WY H1H2H3H4 694 -|WR|0 – FFFF (Hex)|WR HHHH| 695 -|WL|0 - 73FF (Hex)|WL HHHH| 696 -|TC|0 - 2559|TC DDDD| 697 - 698 -**Communication settings in HMI** 699 - 700 -Enable HMI Ethernet in [Project Settings]; 701 - 702 -(% style="text-align:center" %) 703 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 704 - 705 -Set PLC IP in [Device IP] settings; 706 - 707 -(% style="text-align:center" %) 708 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 709 - 710 -**PLC Configuration** 711 - 712 -Connect with PLC, select[Online mode]; 713 - 714 -(% style="text-align:center" %) 715 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 716 - 717 -Set IP address, it is the same LAN parameters with HMI; 718 - 719 -(% style="text-align:center" %) 720 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 721 - 722 -3) Save PLC communication parameter, and restart PLC 723 - 724 -**PLC Monitor Mode** 725 - 726 -Connect with PLC and choose to “online” mode 727 - 728 -(% style="text-align:center" %) 729 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 730 - 731 -Open I/O monitor sheet1 732 - 733 -(% style="text-align:center" %) 734 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 735 - 736 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 737 - 738 -(% style="text-align:center" %) 739 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 740 - 741 -Enter the register address, click OK to view the value of the register. 742 - 743 -(% style="text-align:center" %) 744 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 745 - 746 -(% style="text-align:center" %) 747 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 748 - 749 -**✎Note:** 750 - 751 -* Both word registers and bit registers support even continuous read/write functions; 752 -* The range of registers is based on the specific PLC type; 753 - 754 -**Cable Wiring** 755 - 756 -(% style="text-align:center" %) 757 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 758 - 759 -= **IEC60870-5 104 Client** = 760 - 761 -**HMI Setting** 762 - 763 -(% class="table-bordered" %) 764 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 765 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 766 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 767 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 768 - 769 -**Address List** 770 - 771 -(% class="table-bordered" %) 772 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 773 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 774 -|(% style="width:461px" %)SCNA|0~~16777215.7 775 -|(% style="width:461px" %)DPTB|0~~16777215.7 776 -|(% style="width:461px" %)DCNA|0~~16777215.7 777 -|(% style="width:461px" %)METF|0~~16777215.7 778 -|(% style="width:461px" %)SENC|0~~16777215.7 779 -|(% style="width:461px" %)SENA|0~~16777215.7 780 -|(% style="width:461px" %)MENA|0~~16777215.7 781 -|(% style="width:461px" %)METD|0~~16777215.7 782 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 783 -|(% style="width:461px" %)SCNA|0~~16777215 784 -|(% style="width:461px" %)DPTB|0~~16777215 785 -|(% style="width:461px" %)DCNA|0~~16777215 786 -|(% style="width:461px" %)SENA|0~~16777215 787 -|(% style="width:461px" %)MENA|0~~16777215 788 -|(% style="width:461px" %)METD|0~~16777215 789 -|(% style="width:461px" %)INRO|0~~16777215 790 -|(% style="width:461px" %)TIMESYN|0~~16777215 791 -|(% style="width:461px" %)TIMEZ|0~~16777215 792 -|(% style="width:461px" %)NTP|0~~16777215 793 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 794 -|(% style="width:461px" %)SENC|0~~16777215 795 - 796 -**Address Configuration** 797 - 798 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 799 - 800 -(% style="text-align:center" %) 801 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 802 - 803 -(% style="text-align:center" %) 804 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 805 - 806 -Extended tag name 807 - 808 -Address range for the extended tag. 809 - 810 -**Communication Settings** 811 - 812 -Enable HMI Ethernet in [Project Settings]; 813 - 814 -(% style="text-align:center" %) 815 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 816 - 817 -Set PLC IP in [Device IP] settings; 818 - 819 -(% style="text-align:center" %) 820 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 821 - 822 -**Cable Wiring** 823 - 824 -(% style="text-align:center" %) 825 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 826 - 827 -= **LG XGK FEnet Ethernet** = 828 - 829 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 830 - 831 -**HMI Settings** 832 - 833 -(% class="table-bordered" %) 834 -|**Items**|**Settings**|**Note** 835 -|Protocol|LG XGK FEnet(Ethernet)| 836 -|Connection|Ethernet| 837 -|Port No.|2004| 838 - 839 -**Address List** 840 - 841 -(% class="table-bordered" %) 842 -|**Type**|**Register**|**Range**|**Format**|**Note** 843 -|(% rowspan="14" %)Word|P|0~~2047|P d| 844 -|M|0~~2047|M d| 845 -|K|0~~2047|K d| 846 -|F|0~~2047|F d| 847 -|T|0~~2047|T d| 848 -|C|0~~2047|C d| 849 -|Z|0~~127|Z d| 850 -|S|0~~127|S d| 851 -|L|0~~11263|L d| 852 -|N|0~~21503|N d| 853 -|D|0~~32767|D d| 854 -|R|0~~32767|R d| 855 -|ZR|0~~65535|ZR d| 856 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 857 - 858 -**✎Note:** 859 - 860 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 861 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 862 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 863 - 864 -**Communication settings in HMI** 865 - 866 -Enable HMI Ethernet in [Project Settings]; 867 - 868 -(% style="text-align:center" %) 869 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 870 - 871 -Set PLC IP in [Device IP] settings; 872 - 873 -(% style="text-align:center" %) 874 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 875 - 876 -**Cable Wiring** 877 - 878 878 = **Mitsubishi** = 879 879 880 880 == **FX1S, 1N, 2N Series** == ... ... @@ -2648,8 +2648,6 @@ 2648 2648 2649 2649 **✎Note:** COM3 only available in PI8000/PI9000 series. 2650 2650 2651 -= = 2652 - 2653 2653 = **Printer** = 2654 2654 2655 2655 == **TSPL label printer** == ... ... @@ -2850,3 +2850,283 @@ 2850 2850 2851 2851 (% style="text-align:center" %) 2852 2852 [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]] 2572 + 2573 += **Barcode Scanner** = 2574 + 2575 +Supported: DELI 14880 barcode scanner 2576 + 2577 +**HMI Setting** 2578 + 2579 +|**Items**|**Settings**|**Note** 2580 +|Protocol|Barcode Scanner| 2581 +|Connection|USB| 2582 + 2583 +**Operating Procedures** 2584 + 2585 +Select [Barcode Scanner]; 2586 + 2587 +(% style="text-align:center" %) 2588 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 2589 + 2590 +Set address for receiving; 2591 + 2592 +Set correct length; 2593 + 2594 +(% style="text-align:center" %) 2595 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 2596 + 2597 +**✎Note:** 2598 + 2599 +* The protocol uploads the information acquired by the USB scanner to the HMI; 2600 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 2601 +* Recommended model: DELI 14880 barcode scanner; 2602 + 2603 + 2604 += **Hitachi EHV Series (Ethernet)** = 2605 + 2606 +Supported series: Hitachi EHV series 2607 + 2608 +**HMI Settings** 2609 + 2610 +(% class="table-bordered" %) 2611 +|**Items**|**Settings**|**Note** 2612 +|Protocol|Hitachi EHV series| 2613 +|Connection|Ethernet| 2614 +|Port No.|3004~~3007| 2615 + 2616 +**Address List** 2617 + 2618 +(% class="table-bordered" %) 2619 +|**Type**|**Register**|**Range**|**Format**|**Note** 2620 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 2621 +|M|0 - 7FFF.f (Hex)|M HHHH.h| 2622 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 2623 +H1H2H3H4 Module main number 2624 + 2625 +H1: Remote number 2626 + 2627 +H2: Unit number 2628 + 2629 +H3: Slot number 2630 + 2631 +H4: Word number of Module 2632 + 2633 +H Sub number of Module 2634 + 2635 +For example:X21.3 2636 + 2637 +Slot number 2 2638 + 2639 +Word number of module is 1 2640 + 2641 +Bit number of module is 3 2642 + 2643 +Remote number and unit number are 0 2644 +))) 2645 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 2646 +|R|0 – FF.f (Hex)|R HH.h| 2647 +|L|0 - 73FF.f (Hex)|L HHHH.h| 2648 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 2649 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 2650 +H1H2H3H4 Module main number 2651 + 2652 +H1: Remote number 2653 + 2654 +H2: Unit number 2655 + 2656 +H3: Slot number 2657 + 2658 +H4: Word number of module 2659 + 2660 +For example:WX21 2661 + 2662 +Word number of module is 1 2663 + 2664 +Slot number is 2 2665 + 2666 +Remote number and unit number are 0 2667 +))) 2668 +|WY|0 – FFFF (Hex)|WY H1H2H3H4 2669 +|WR|0 – FFFF (Hex)|WR HHHH| 2670 +|WL|0 - 73FF (Hex)|WL HHHH| 2671 +|TC|0 - 2559|TC DDDD| 2672 + 2673 +**Communication settings in HMI** 2674 + 2675 +Enable HMI Ethernet in [Project Settings]; 2676 + 2677 +(% style="text-align:center" %) 2678 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2679 + 2680 +Set PLC IP in [Device IP] settings; 2681 + 2682 +(% style="text-align:center" %) 2683 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 2684 + 2685 +**PLC Configuration** 2686 + 2687 +Connect with PLC, select[Online mode]; 2688 + 2689 +(% style="text-align:center" %) 2690 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 2691 + 2692 +Set IP address, it is the same LAN parameters with HMI; 2693 + 2694 +(% style="text-align:center" %) 2695 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 2696 + 2697 +3) Save PLC communication parameter, and restart PLC 2698 + 2699 +**PLC Monitor Mode** 2700 + 2701 +Connect with PLC and choose to “online” mode 2702 + 2703 +(% style="text-align:center" %) 2704 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 2705 + 2706 +Open I/O monitor sheet1 2707 + 2708 +(% style="text-align:center" %) 2709 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 2710 + 2711 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 2712 + 2713 +(% style="text-align:center" %) 2714 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 2715 + 2716 +Enter the register address, click OK to view the value of the register. 2717 + 2718 +(% style="text-align:center" %) 2719 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2720 + 2721 +(% style="text-align:center" %) 2722 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2723 + 2724 +**✎Note:** 2725 + 2726 +* Both word registers and bit registers support even continuous read/write functions; 2727 +* The range of registers is based on the specific PLC type; 2728 + 2729 +**Cable Wiring** 2730 + 2731 +(% style="text-align:center" %) 2732 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2733 + 2734 += **IEC60870-5 104 Client** = 2735 + 2736 +**HMI Setting** 2737 + 2738 +(% class="table-bordered" %) 2739 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 2740 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 2741 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 2742 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 2743 + 2744 +**Address List** 2745 + 2746 +(% class="table-bordered" %) 2747 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 2748 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 2749 +|(% style="width:461px" %)SCNA|0~~16777215.7 2750 +|(% style="width:461px" %)DPTB|0~~16777215.7 2751 +|(% style="width:461px" %)DCNA|0~~16777215.7 2752 +|(% style="width:461px" %)METF|0~~16777215.7 2753 +|(% style="width:461px" %)SENC|0~~16777215.7 2754 +|(% style="width:461px" %)SENA|0~~16777215.7 2755 +|(% style="width:461px" %)MENA|0~~16777215.7 2756 +|(% style="width:461px" %)METD|0~~16777215.7 2757 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 2758 +|(% style="width:461px" %)SCNA|0~~16777215 2759 +|(% style="width:461px" %)DPTB|0~~16777215 2760 +|(% style="width:461px" %)DCNA|0~~16777215 2761 +|(% style="width:461px" %)SENA|0~~16777215 2762 +|(% style="width:461px" %)MENA|0~~16777215 2763 +|(% style="width:461px" %)METD|0~~16777215 2764 +|(% style="width:461px" %)INRO|0~~16777215 2765 +|(% style="width:461px" %)TIMESYN|0~~16777215 2766 +|(% style="width:461px" %)TIMEZ|0~~16777215 2767 +|(% style="width:461px" %)NTP|0~~16777215 2768 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 2769 +|(% style="width:461px" %)SENC|0~~16777215 2770 + 2771 +**Address Configuration** 2772 + 2773 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 2774 + 2775 +(% style="text-align:center" %) 2776 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 2777 + 2778 +(% style="text-align:center" %) 2779 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 2780 + 2781 +Extended tag name 2782 + 2783 +Address range for the extended tag. 2784 + 2785 +**Communication Settings** 2786 + 2787 +Enable HMI Ethernet in [Project Settings]; 2788 + 2789 +(% style="text-align:center" %) 2790 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2791 + 2792 +Set PLC IP in [Device IP] settings; 2793 + 2794 +(% style="text-align:center" %) 2795 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 2796 + 2797 +**Cable Wiring** 2798 + 2799 +(% style="text-align:center" %) 2800 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2801 + 2802 += **LG XGK FEnet Ethernet** = 2803 + 2804 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2805 + 2806 +**HMI Settings** 2807 + 2808 +(% class="table-bordered" %) 2809 +|**Items**|**Settings**|**Note** 2810 +|Protocol|LG XGK FEnet(Ethernet)| 2811 +|Connection|Ethernet| 2812 +|Port No.|2004| 2813 + 2814 +**Address List** 2815 + 2816 +(% class="table-bordered" %) 2817 +|**Type**|**Register**|**Range**|**Format**|**Note** 2818 +|(% rowspan="14" %)Word|P|0~~2047|P d| 2819 +|M|0~~2047|M d| 2820 +|K|0~~2047|K d| 2821 +|F|0~~2047|F d| 2822 +|T|0~~2047|T d| 2823 +|C|0~~2047|C d| 2824 +|Z|0~~127|Z d| 2825 +|S|0~~127|S d| 2826 +|L|0~~11263|L d| 2827 +|N|0~~21503|N d| 2828 +|D|0~~32767|D d| 2829 +|R|0~~32767|R d| 2830 +|ZR|0~~65535|ZR d| 2831 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 2832 + 2833 +**✎Note:** 2834 + 2835 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 2836 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 2837 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 2838 + 2839 +**Communication settings in HMI** 2840 + 2841 +Enable HMI Ethernet in [Project Settings]; 2842 + 2843 +(% style="text-align:center" %) 2844 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2845 + 2846 +Set PLC IP in [Device IP] settings; 2847 + 2848 +(% style="text-align:center" %) 2849 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 2850 + 2851 +**Cable Wiring**