... ... @@ -469,10 +469,50 @@
469 469  
470 470  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
471 471  
472 -= =
472 += Create communication with **Rockwell PLC** =
473 473  
474 -= **Allen-Bradley** =
475 475  
475 +== **MicroLogix Protocol** ==
476 +
477 +MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
478 +
479 +**HMI Settings**
480 +
481 +(% class="table-bordered" %)
482 +|**Item**|**Settings**|**Note**
483 +|Protocol|Allen-Bradlley MicroLogix|
484 +|Connection|RS232|
485 +|Baud rate|19200|
486 +|Data bit|8|
487 +|Parity|None|
488 +|Stop bit|1|
489 +|PLC station No.|1|
490 +
491 +**Address List**
492 +
493 +(% class="table-bordered" %)
494 +|**Type**|**Device registers**|**Format**|**Range**|**Note**
495 +|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
496 +|O|O d.d|0.0~~255.15|
497 +|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
498 +|S|S d.d|0.0~~255.15|
499 +|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
500 +|(% rowspan="9" %)Word|S|S d|0~~255|
501 +|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
502 +|TP|TP nnhh|0~~ffff
503 +|CS|CS nnhh|0~~ffff
504 +|CP|CP nnhh|0~~ffff
505 +|N|N nnhh|0~~ffff
506 +|C|C nnhh|0~~ffff
507 +|T|T nnhh|0~~ffff
508 +|R|R nnhh|0~~ffff
509 +
510 +**Cable Wiring**
511 +
512 +
513 +(% style="text-align:center" %)
514 +[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
515 +
476 476  == **FreeTag Ethernet/IP (CompactLogix)** ==
477 477  
478 478  Allen-Brandly CompactLogix
... ... @@ -530,46 +530,6 @@
530 530  (% style="text-align:center" %)
531 531  [[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
532 532  
533 -== **MicroLogix** ==
534 -
535 -MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
536 -
537 -**HMI Settings**
538 -
539 -(% class="table-bordered" %)
540 -|**Item**|**Settings**|**Note**
541 -|Protocol|Allen-Bradlley MicroLogix|
542 -|Connection|RS232|
543 -|Baud rate|19200|
544 -|Data bit|8|
545 -|Parity|None|
546 -|Stop bit|1|
547 -|PLC station No.|1|
548 -
549 -**Address List**
550 -
551 -(% class="table-bordered" %)
552 -|**Type**|**Device registers**|**Format**|**Range**|**Note**
553 -|(% rowspan="5" %)Bit|I|I d.d|0.0~~255.15|
554 -|O|O d.d|0.0~~255.15|
555 -|B|B nnhh.dd|0.0~~ffff.15|nn: block number (hex)
556 -|S|S d.d|0.0~~255.15|
557 -|N|N nnhh.dd|0.0~~ffff.15|nn: block number (hex)
558 -|(% rowspan="9" %)Word|S|S d|0~~255|
559 -|TS|TS nnhh|0~~ffff|(% rowspan="8" %)nn: block number (hex)
560 -|TP|TP nnhh|0~~ffff
561 -|CS|CS nnhh|0~~ffff
562 -|CP|CP nnhh|0~~ffff
563 -|N|N nnhh|0~~ffff
564 -|C|C nnhh|0~~ffff
565 -|T|T nnhh|0~~ffff
566 -|R|R nnhh|0~~ffff
567 -
568 -**Cable Wiring**
569 -
570 -(% style="text-align:center" %)
571 -[[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
572 -
573 573  == **AB PLC address edit** ==
574 574  
575 575  The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
... ... @@ -596,37 +596,6 @@
596 596  |(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
597 597  |(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
598 598  
599 -= **Barcode Scanner** =
600 -
601 -Supported: DELI 14880 barcode scanner
602 -
603 -**HMI Setting**
604 -
605 -(% class="table-bordered" %)
606 -|**Items**|**Settings**|**Note**
607 -|Protocol|Barcode Scanner|
608 -|Connection|USB|
609 -
610 -**Operating Procedures**
611 -
612 -Select [Barcode Scanner];
613 -
614 -(% style="text-align:center" %)
615 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
616 -
617 -Set address for receiving;
618 -
619 -Set correct length;
620 -
621 -(% style="text-align:center" %)
622 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
623 -
624 -**✎Note:**
625 -
626 -* The protocol uploads the information acquired by the USB scanner to the HMI;
627 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
628 -* Recommended model: DELI 14880 barcode scanner;
629 -
630 630  = **Hitachi EHV Series (Ethernet)** =
631 631  
632 632  Supported series: Hitachi EHV series
... ... @@ -2649,8 +2649,6 @@
2649 2649  
2650 2650  **✎Note:** COM3 only available in PI8000/PI9000 series.
2651 2651  
2652 -= =
2653 -
2654 2654  = **Printer** =
2655 2655  
2656 2656  == **TSPL label printer** ==
... ... @@ -2851,3 +2851,33 @@
2851 2851  
2852 2852  (% style="text-align:center" %)
2853 2853  [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
2821 +
2822 += **Barcode Scanner** =
2823 +
2824 +Supported: DELI 14880 barcode scanner
2825 +
2826 +**HMI Setting**
2827 +
2828 +|**Items**|**Settings**|**Note**
2829 +|Protocol|Barcode Scanner|
2830 +|Connection|USB|
2831 +
2832 +**Operating Procedures**
2833 +
2834 +Select [Barcode Scanner];
2835 +
2836 +(% style="text-align:center" %)
2837 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
2838 +
2839 +Set address for receiving;
2840 +
2841 +Set correct length;
2842 +
2843 +(% style="text-align:center" %)
2844 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
2845 +
2846 +**✎Note:**
2847 +
2848 +* The protocol uploads the information acquired by the USB scanner to the HMI;
2849 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
2850 +* Recommended model: DELI 14880 barcode scanner;