... ... @@ -399,7 +399,6 @@
399 399  
400 400  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
401 401  
402 -
403 403  **Software configuration of PLC**
404 404  
405 405  **1)PLC programming software**
... ... @@ -469,69 +469,10 @@
469 469  
470 470  The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC.
471 471  
472 -= =
471 += Create communication with **Rockwell PLC** =
473 473  
474 -= **Allen-Bradley** =
473 +== **MicroLogix Protocol** ==
475 475  
476 -== **FreeTag Ethernet/IP (CompactLogix)** ==
477 -
478 -Allen-Brandly CompactLogix
479 -
480 -**HMI Settings**
481 -
482 -(% class="table-bordered" %)
483 -|**Items**|**Settings**|**Note**
484 -|Protocol|Allen-Brandley FreeTag Ethernet/IP (CompactLogix)|
485 -|Connection|Ethernet|
486 -|Port No.|44818|
487 -
488 -**PLC Setting**
489 -
490 -Create new tags
491 -
492 -(% style="text-align:center" %)
493 -[[image:12.PLC Protocol_html_a748a27dcf7f1124.png||data-xwiki-image-style-alignment="center" height="411" width="700" class="img-thumbnail"]]
494 -
495 -Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments])
496 -
497 -(% style="text-align:center" %)
498 -[[image:12.PLC Protocol_html_151379170bb8ff3e.png||data-xwiki-image-style-alignment="center" height="352" width="700" class="img-thumbnail"]]
499 -
500 -Import labels, please open [Communication] window and click [Import label];
501 -
502 -Select csv file, all tags will be displayed as belows;
503 -
504 -(% style="text-align:center" %)
505 -[[image:12.PLC Protocol_html_af192e54dee96f38.png||data-xwiki-image-style-alignment="center" height="586" width="700" class="img-thumbnail"]]
506 -
507 -**✎Note:**
508 -
509 -Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format.
510 -
511 -(% style="text-align:center" %)
512 -[[image:12.PLC Protocol_html_33df1d63ebe53726.png||data-xwiki-image-style-alignment="center" height="206" width="700" class="img-thumbnail"]]
513 -
514 -The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting.
515 -
516 -**Communication settings in HMI**
517 -
518 -Enable HMI Ethernet in [Project Settings];
519 -
520 -(% style="text-align:center" %)
521 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="106" width="400" class="img-thumbnail"]]
522 -
523 -Set PLC IP in [Device IP] settings;
524 -
525 -(% style="text-align:center" %)
526 -[[image:12.PLC Protocol_html_27870d373581892e.png||data-xwiki-image-style-alignment="center" height="206" width="600" class="img-thumbnail"]]
527 -
528 -**Cable Wiring**
529 -
530 -(% style="text-align:center" %)
531 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
532 -
533 -== **MicroLogix** ==
534 -
535 535  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
536 536  
537 537  **HMI Settings**
... ... @@ -567,315 +567,95 @@
567 567  
568 568  **Cable Wiring**
569 569  
510 +
570 570  (% style="text-align:center" %)
571 571  [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]]
572 572  
573 -== **AB PLC address edit** ==
514 +== **FreeTag Ethernet/IP (CompactLogix)** ==
574 574  
575 -The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
516 +Allen-Brandly CompactLogix
576 576  
577 -* **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal).
578 -* **Bit address B:** The address ranges from 000.0 to fff.15. The first f from left to right represents the block number (hexadecimal); The second and third f from left to right represent the word address (hexadecimal). The value 0 to 15 after the decimal point reprensents the sub address (decimal).
579 -* **Word address S:** The word address ranges from 0 to 255 (decimal).
580 -* **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal).
581 -
582 -**✎Note: **Register address TP, CS, CP, N, F and TS address edit are same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table.
583 -
584 -|(% style="width:393px" %)**PLC bit address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
585 -|(% style="width:393px" %)I|(% style="width:350px" %)dd.dd|(% style="width:333px" %)I 0.0 ~~ 255.15
586 -|(% style="width:393px" %)O|(% style="width:350px" %)dd.dd|(% style="width:333px" %)O 0.0 ~~ 255.15
587 -|(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
588 -|(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
589 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
590 -|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
591 -|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255
592 -|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF
593 -|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF
594 -|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF
595 -|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF
596 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
597 -|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
598 -
599 -= **Barcode Scanner** =
600 -
601 -Supported: DELI 14880 barcode scanner
602 -
603 -**HMI Setting**
604 -
605 -(% class="table-bordered" %)
606 -|**Items**|**Settings**|**Note**
607 -|Protocol|Barcode Scanner|
608 -|Connection|USB|
609 -
610 -**Operating Procedures**
611 -
612 -Select [Barcode Scanner];
613 -
614 -(% style="text-align:center" %)
615 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
616 -
617 -Set address for receiving;
618 -
619 -Set correct length;
620 -
621 -(% style="text-align:center" %)
622 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
623 -
624 -**✎Note:**
625 -
626 -* The protocol uploads the information acquired by the USB scanner to the HMI;
627 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
628 -* Recommended model: DELI 14880 barcode scanner;
629 -
630 -= **Hitachi EHV Series (Ethernet)** =
631 -
632 -Supported series: Hitachi EHV series
633 -
634 634  **HMI Settings**
635 635  
636 636  (% class="table-bordered" %)
637 637  |**Items**|**Settings**|**Note**
638 -|Protocol|Hitachi EHV series|
522 +|Protocol|Allen-Brandley FreeTag Ethernet/IP (CompactLogix)|
639 639  |Connection|Ethernet|
640 -|Port No.|3004~~3007|
524 +|Port No.|44818|
641 641  
642 -**Address List**
526 +**PLC Setting**
643 643  
644 -(% class="table-bordered" %)
645 -|**Type**|**Register**|**Range**|**Format**|**Note**
646 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
647 -|M|0 - 7FFF.f (Hex)|M HHHH.h|
648 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
649 -H1H2H3H4 Module main number
528 +Create new tags
650 650  
651 -H1: Remote number
652 -
653 -H2: Unit number
654 -
655 -H3: Slot number
656 -
657 -H4: Word number of Module
658 -
659 -H Sub number of Module
660 -
661 -For example:X21.3
662 -
663 -Slot number 2
664 -
665 -Word number of module is 1
666 -
667 -Bit number of module is 3
668 -
669 -Remote number and unit number are 0
670 -)))
671 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
672 -|R|0 – FF.f (Hex)|R HH.h|
673 -|L|0 - 73FF.f (Hex)|L HHHH.h|
674 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
675 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
676 -H1H2H3H4 Module main number
677 -
678 -H1: Remote number
679 -
680 -H2: Unit number
681 -
682 -H3: Slot number
683 -
684 -H4: Word number of module
685 -
686 -For example:WX21
687 -
688 -Word number of module is 1
689 -
690 -Slot number is 2
691 -
692 -Remote number and unit number are 0
693 -)))
694 -|WY|0 – FFFF (Hex)|WY H1H2H3H4
695 -|WR|0 – FFFF (Hex)|WR HHHH|
696 -|WL|0 - 73FF (Hex)|WL HHHH|
697 -|TC|0 - 2559|TC DDDD|
698 -
699 -**Communication settings in HMI**
700 -
701 -Enable HMI Ethernet in [Project Settings];
702 -
703 703  (% style="text-align:center" %)
704 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
531 +[[image:12.PLC Protocol_html_a748a27dcf7f1124.png||data-xwiki-image-style-alignment="center" height="411" width="700" class="img-thumbnail"]]
705 705  
706 -Set PLC IP in [Device IP] settings;
533 +Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments])
707 707  
708 708  (% style="text-align:center" %)
709 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
536 +[[image:12.PLC Protocol_html_151379170bb8ff3e.png||data-xwiki-image-style-alignment="center" height="352" width="700" class="img-thumbnail"]]
710 710  
711 -**PLC Configuration**
538 +Import labels, please open [Communication] window and click [Import label];
712 712  
713 -Connect with PLC, select[Online mode];
540 +Select csv file, all tags will be displayed as belows;
714 714  
715 715  (% style="text-align:center" %)
716 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
543 +[[image:12.PLC Protocol_html_af192e54dee96f38.png||data-xwiki-image-style-alignment="center" height="586" width="700" class="img-thumbnail"]]
717 717  
718 -Set IP address, it is the same LAN parameters with HMI;
719 -
720 -(% style="text-align:center" %)
721 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
722 -
723 -3) Save PLC communication parameter, and restart PLC
724 -
725 -**PLC Monitor Mode**
726 -
727 -Connect with PLC and choose to “online” mode
728 -
729 -(% style="text-align:center" %)
730 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
731 -
732 -Open I/O monitor sheet1
733 -
734 -(% style="text-align:center" %)
735 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
736 -
737 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
738 -
739 -(% style="text-align:center" %)
740 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
741 -
742 -Enter the register address, click OK to view the value of the register.
743 -
744 -(% style="text-align:center" %)
745 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
746 -
747 -(% style="text-align:center" %)
748 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
749 -
750 750  **✎Note:**
751 751  
752 -* Both word registers and bit registers support even continuous read/write functions;
753 -* The range of registers is based on the specific PLC type;
547 +Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format.
754 754  
755 -**Cable Wiring**
756 -
757 757  (% style="text-align:center" %)
758 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
550 +[[image:12.PLC Protocol_html_33df1d63ebe53726.png||data-xwiki-image-style-alignment="center" height="206" width="700" class="img-thumbnail"]]
759 759  
760 -= **IEC60870-5 104 Client** =
552 +The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting.
761 761  
762 -**HMI Setting**
554 +**Communication settings in HMI**
763 763  
764 -(% class="table-bordered" %)
765 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
766 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
767 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
768 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
769 -
770 -**Address List**
771 -
772 -(% class="table-bordered" %)
773 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
774 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
775 -|(% style="width:461px" %)SCNA|0~~16777215.7
776 -|(% style="width:461px" %)DPTB|0~~16777215.7
777 -|(% style="width:461px" %)DCNA|0~~16777215.7
778 -|(% style="width:461px" %)METF|0~~16777215.7
779 -|(% style="width:461px" %)SENC|0~~16777215.7
780 -|(% style="width:461px" %)SENA|0~~16777215.7
781 -|(% style="width:461px" %)MENA|0~~16777215.7
782 -|(% style="width:461px" %)METD|0~~16777215.7
783 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
784 -|(% style="width:461px" %)SCNA|0~~16777215
785 -|(% style="width:461px" %)DPTB|0~~16777215
786 -|(% style="width:461px" %)DCNA|0~~16777215
787 -|(% style="width:461px" %)SENA|0~~16777215
788 -|(% style="width:461px" %)MENA|0~~16777215
789 -|(% style="width:461px" %)METD|0~~16777215
790 -|(% style="width:461px" %)INRO|0~~16777215
791 -|(% style="width:461px" %)TIMESYN|0~~16777215
792 -|(% style="width:461px" %)TIMEZ|0~~16777215
793 -|(% style="width:461px" %)NTP|0~~16777215
794 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
795 -|(% style="width:461px" %)SENC|0~~16777215
796 -
797 -**Address Configuration**
798 -
799 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
800 -
801 -(% style="text-align:center" %)
802 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
803 -
804 -(% style="text-align:center" %)
805 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
806 -
807 -Extended tag name
808 -
809 -Address range for the extended tag.
810 -
811 -**Communication Settings**
812 -
813 813  Enable HMI Ethernet in [Project Settings];
814 814  
815 815  (% style="text-align:center" %)
816 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
559 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="106" width="400" class="img-thumbnail"]]
817 817  
818 818  Set PLC IP in [Device IP] settings;
819 819  
820 820  (% style="text-align:center" %)
821 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
564 +[[image:12.PLC Protocol_html_27870d373581892e.png||data-xwiki-image-style-alignment="center" height="206" width="600" class="img-thumbnail"]]
822 822  
823 823  **Cable Wiring**
824 824  
825 825  (% style="text-align:center" %)
826 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
569 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]]
827 827  
828 -= **LG XGK FEnet Ethernet** =
571 +== **AB PLC address edit** ==
829 829  
830 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
573 +The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200.
831 831  
832 -**HMI Settings**
575 +* **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal).
576 +* **Bit address B:** The address ranges from 000.0 to fff.15. The first f from left to right represents the block number (hexadecimal); The second and third f from left to right represent the word address (hexadecimal). The value 0 to 15 after the decimal point reprensents the sub address (decimal).
577 +* **Word address S:** The word address ranges from 0 to 255 (decimal).
578 +* **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal).
833 833  
834 -(% class="table-bordered" %)
835 -|**Items**|**Settings**|**Note**
836 -|Protocol|LG XGK FEnet(Ethernet)|
837 -|Connection|Ethernet|
838 -|Port No.|2004|
580 +**✎Note: **Register address TP, CS, CP, N, F and TS address edit are same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table.
839 839  
840 -**Address List**
582 +|(% style="width:393px" %)**PLC bit address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
583 +|(% style="width:393px" %)I|(% style="width:350px" %)dd.dd|(% style="width:333px" %)I 0.0 ~~ 255.15
584 +|(% style="width:393px" %)O|(% style="width:350px" %)dd.dd|(% style="width:333px" %)O 0.0 ~~ 255.15
585 +|(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
586 +|(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
587 +|(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
588 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
589 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
590 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
591 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
592 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
593 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
594 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
595 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
841 841  
842 -(% class="table-bordered" %)
843 -|**Type**|**Register**|**Range**|**Format**|**Note**
844 -|(% rowspan="14" %)Word|P|0~~2047|P d|
845 -|M|0~~2047|M d|
846 -|K|0~~2047|K d|
847 -|F|0~~2047|F d|
848 -|T|0~~2047|T d|
849 -|C|0~~2047|C d|
850 -|Z|0~~127|Z d|
851 -|S|0~~127|S d|
852 -|L|0~~11263|L d|
853 -|N|0~~21503|N d|
854 -|D|0~~32767|D d|
855 -|R|0~~32767|R d|
856 -|ZR|0~~65535|ZR d|
857 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
597 += =
858 858  
859 -**✎Note:**
860 -
861 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
862 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
863 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
864 -
865 -**Communication settings in HMI**
866 -
867 -Enable HMI Ethernet in [Project Settings];
868 -
869 -(% style="text-align:center" %)
870 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
871 -
872 -Set PLC IP in [Device IP] settings;
873 -
874 -(% style="text-align:center" %)
875 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
876 -
877 -**Cable Wiring**
878 -
879 879  = **Mitsubishi** =
880 880  
881 881  == **FX1S, 1N, 2N Series** ==
... ... @@ -2649,8 +2649,6 @@
2649 2649  
2650 2650  **✎Note:** COM3 only available in PI8000/PI9000 series.
2651 2651  
2652 -= =
2653 -
2654 2654  = **Printer** =
2655 2655  
2656 2656  == **TSPL label printer** ==
... ... @@ -2851,3 +2851,282 @@
2851 2851  
2852 2852  (% style="text-align:center" %)
2853 2853  [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
2572 +
2573 += **Barcode Scanner** =
2574 +
2575 +Supported: DELI 14880 barcode scanner
2576 +
2577 +**HMI Setting**
2578 +
2579 +|**Items**|**Settings**|**Note**
2580 +|Protocol|Barcode Scanner|
2581 +|Connection|USB|
2582 +
2583 +**Operating Procedures**
2584 +
2585 +Select [Barcode Scanner];
2586 +
2587 +(% style="text-align:center" %)
2588 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
2589 +
2590 +Set address for receiving;
2591 +
2592 +Set correct length;
2593 +
2594 +(% style="text-align:center" %)
2595 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
2596 +
2597 +**✎Note:**
2598 +
2599 +* The protocol uploads the information acquired by the USB scanner to the HMI;
2600 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
2601 +* Recommended model: DELI 14880 barcode scanner;
2602 +
2603 += **Hitachi EHV Series (Ethernet)** =
2604 +
2605 +Supported series: Hitachi EHV series
2606 +
2607 +**HMI Settings**
2608 +
2609 +(% class="table-bordered" %)
2610 +|**Items**|**Settings**|**Note**
2611 +|Protocol|Hitachi EHV series|
2612 +|Connection|Ethernet|
2613 +|Port No.|3004~~3007|
2614 +
2615 +**Address List**
2616 +
2617 +(% class="table-bordered" %)
2618 +|**Type**|**Register**|**Range**|**Format**|**Note**
2619 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
2620 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
2621 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
2622 +H1H2H3H4 Module main number
2623 +
2624 +H1: Remote number
2625 +
2626 +H2: Unit number
2627 +
2628 +H3: Slot number
2629 +
2630 +H4: Word number of Module
2631 +
2632 +H Sub number of Module
2633 +
2634 +For example:X21.3
2635 +
2636 +Slot number 2
2637 +
2638 +Word number of module is 1
2639 +
2640 +Bit number of module is 3
2641 +
2642 +Remote number and unit number are 0
2643 +)))
2644 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
2645 +|R|0 – FF.f (Hex)|R HH.h|
2646 +|L|0 - 73FF.f (Hex)|L HHHH.h|
2647 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
2648 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
2649 +H1H2H3H4 Module main number
2650 +
2651 +H1: Remote number
2652 +
2653 +H2: Unit number
2654 +
2655 +H3: Slot number
2656 +
2657 +H4: Word number of module
2658 +
2659 +For example:WX21
2660 +
2661 +Word number of module is 1
2662 +
2663 +Slot number is 2
2664 +
2665 +Remote number and unit number are 0
2666 +)))
2667 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
2668 +|WR|0 – FFFF (Hex)|WR HHHH|
2669 +|WL|0 - 73FF (Hex)|WL HHHH|
2670 +|TC|0 - 2559|TC DDDD|
2671 +
2672 +**Communication settings in HMI**
2673 +
2674 +Enable HMI Ethernet in [Project Settings];
2675 +
2676 +(% style="text-align:center" %)
2677 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2678 +
2679 +Set PLC IP in [Device IP] settings;
2680 +
2681 +(% style="text-align:center" %)
2682 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2683 +
2684 +**PLC Configuration**
2685 +
2686 +Connect with PLC, select[Online mode];
2687 +
2688 +(% style="text-align:center" %)
2689 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
2690 +
2691 +Set IP address, it is the same LAN parameters with HMI;
2692 +
2693 +(% style="text-align:center" %)
2694 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
2695 +
2696 +3) Save PLC communication parameter, and restart PLC
2697 +
2698 +**PLC Monitor Mode**
2699 +
2700 +Connect with PLC and choose to “online” mode
2701 +
2702 +(% style="text-align:center" %)
2703 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
2704 +
2705 +Open I/O monitor sheet1
2706 +
2707 +(% style="text-align:center" %)
2708 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
2709 +
2710 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
2711 +
2712 +(% style="text-align:center" %)
2713 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
2714 +
2715 +Enter the register address, click OK to view the value of the register.
2716 +
2717 +(% style="text-align:center" %)
2718 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2719 +
2720 +(% style="text-align:center" %)
2721 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2722 +
2723 +**✎Note:**
2724 +
2725 +* Both word registers and bit registers support even continuous read/write functions;
2726 +* The range of registers is based on the specific PLC type;
2727 +
2728 +**Cable Wiring**
2729 +
2730 +(% style="text-align:center" %)
2731 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2732 +
2733 += **IEC60870-5 104 Client** =
2734 +
2735 +**HMI Setting**
2736 +
2737 +(% class="table-bordered" %)
2738 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
2739 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
2740 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
2741 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
2742 +
2743 +**Address List**
2744 +
2745 +(% class="table-bordered" %)
2746 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
2747 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
2748 +|(% style="width:461px" %)SCNA|0~~16777215.7
2749 +|(% style="width:461px" %)DPTB|0~~16777215.7
2750 +|(% style="width:461px" %)DCNA|0~~16777215.7
2751 +|(% style="width:461px" %)METF|0~~16777215.7
2752 +|(% style="width:461px" %)SENC|0~~16777215.7
2753 +|(% style="width:461px" %)SENA|0~~16777215.7
2754 +|(% style="width:461px" %)MENA|0~~16777215.7
2755 +|(% style="width:461px" %)METD|0~~16777215.7
2756 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
2757 +|(% style="width:461px" %)SCNA|0~~16777215
2758 +|(% style="width:461px" %)DPTB|0~~16777215
2759 +|(% style="width:461px" %)DCNA|0~~16777215
2760 +|(% style="width:461px" %)SENA|0~~16777215
2761 +|(% style="width:461px" %)MENA|0~~16777215
2762 +|(% style="width:461px" %)METD|0~~16777215
2763 +|(% style="width:461px" %)INRO|0~~16777215
2764 +|(% style="width:461px" %)TIMESYN|0~~16777215
2765 +|(% style="width:461px" %)TIMEZ|0~~16777215
2766 +|(% style="width:461px" %)NTP|0~~16777215
2767 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
2768 +|(% style="width:461px" %)SENC|0~~16777215
2769 +
2770 +**Address Configuration**
2771 +
2772 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
2773 +
2774 +(% style="text-align:center" %)
2775 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
2776 +
2777 +(% style="text-align:center" %)
2778 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
2779 +
2780 +Extended tag name
2781 +
2782 +Address range for the extended tag.
2783 +
2784 +**Communication Settings**
2785 +
2786 +Enable HMI Ethernet in [Project Settings];
2787 +
2788 +(% style="text-align:center" %)
2789 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2790 +
2791 +Set PLC IP in [Device IP] settings;
2792 +
2793 +(% style="text-align:center" %)
2794 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
2795 +
2796 +**Cable Wiring**
2797 +
2798 +(% style="text-align:center" %)
2799 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2800 +
2801 += **LG XGK FEnet Ethernet** =
2802 +
2803 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
2804 +
2805 +**HMI Settings**
2806 +
2807 +(% class="table-bordered" %)
2808 +|**Items**|**Settings**|**Note**
2809 +|Protocol|LG XGK FEnet(Ethernet)|
2810 +|Connection|Ethernet|
2811 +|Port No.|2004|
2812 +
2813 +**Address List**
2814 +
2815 +(% class="table-bordered" %)
2816 +|**Type**|**Register**|**Range**|**Format**|**Note**
2817 +|(% rowspan="14" %)Word|P|0~~2047|P d|
2818 +|M|0~~2047|M d|
2819 +|K|0~~2047|K d|
2820 +|F|0~~2047|F d|
2821 +|T|0~~2047|T d|
2822 +|C|0~~2047|C d|
2823 +|Z|0~~127|Z d|
2824 +|S|0~~127|S d|
2825 +|L|0~~11263|L d|
2826 +|N|0~~21503|N d|
2827 +|D|0~~32767|D d|
2828 +|R|0~~32767|R d|
2829 +|ZR|0~~65535|ZR d|
2830 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
2831 +
2832 +**✎Note:**
2833 +
2834 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
2835 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
2836 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
2837 +
2838 +**Communication settings in HMI**
2839 +
2840 +Enable HMI Ethernet in [Project Settings];
2841 +
2842 +(% style="text-align:center" %)
2843 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2844 +
2845 +Set PLC IP in [Device IP] settings;
2846 +
2847 +(% style="text-align:center" %)
2848 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
2849 +
2850 +**Cable Wiring**