Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 73.1
edited by Ben
on 2022/08/29 14:15
Change comment: There is no comment for this version
To version 80.1
edited by Ben
on 2022/08/29 14:20
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -399,7 +399,6 @@
399 399  
400 400  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
401 401  
402 -
403 403  **Software configuration of PLC**
404 404  
405 405  **1)PLC programming software**
... ... @@ -471,7 +471,6 @@
471 471  
472 472  = Create communication with **Rockwell PLC** =
473 473  
474 -
475 475  == **MicroLogix Protocol** ==
476 476  
477 477  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -587,295 +587,17 @@
587 587  |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
588 588  |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
589 589  |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
590 -|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
591 -|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255
592 -|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF
593 -|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF
594 -|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF
595 -|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF
596 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
597 -|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
588 +|**PLC word address type**|**Address format**|**Address range**
589 +|S|ddd|S0 ~~ 255
590 +|TS|ffff|TS0 ~~ FFFF
591 +|TP|ffff|TP0 ~~ FFFF
592 +|CS|ffff|CS0 ~~ FFFF
593 +|CP|ffff|CP0 ~~ FFFF
594 +|N|ffff|N0 ~~ FFFF
595 +|F|ffff|F0 ~~ FFFF
598 598  
599 -= **Barcode Scanner** =
597 += =
600 600  
601 -Supported: DELI 14880 barcode scanner
602 -
603 -**HMI Setting**
604 -
605 -(% class="table-bordered" %)
606 -|**Items**|**Settings**|**Note**
607 -|Protocol|Barcode Scanner|
608 -|Connection|USB|
609 -
610 -**Operating Procedures**
611 -
612 -Select [Barcode Scanner];
613 -
614 -(% style="text-align:center" %)
615 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
616 -
617 -Set address for receiving;
618 -
619 -Set correct length;
620 -
621 -(% style="text-align:center" %)
622 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
623 -
624 -**✎Note:**
625 -
626 -* The protocol uploads the information acquired by the USB scanner to the HMI;
627 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
628 -* Recommended model: DELI 14880 barcode scanner;
629 -
630 -= **Hitachi EHV Series (Ethernet)** =
631 -
632 -Supported series: Hitachi EHV series
633 -
634 -**HMI Settings**
635 -
636 -(% class="table-bordered" %)
637 -|**Items**|**Settings**|**Note**
638 -|Protocol|Hitachi EHV series|
639 -|Connection|Ethernet|
640 -|Port No.|3004~~3007|
641 -
642 -**Address List**
643 -
644 -(% class="table-bordered" %)
645 -|**Type**|**Register**|**Range**|**Format**|**Note**
646 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
647 -|M|0 - 7FFF.f (Hex)|M HHHH.h|
648 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
649 -H1H2H3H4 Module main number
650 -
651 -H1: Remote number
652 -
653 -H2: Unit number
654 -
655 -H3: Slot number
656 -
657 -H4: Word number of Module
658 -
659 -H Sub number of Module
660 -
661 -For example:X21.3
662 -
663 -Slot number 2
664 -
665 -Word number of module is 1
666 -
667 -Bit number of module is 3
668 -
669 -Remote number and unit number are 0
670 -)))
671 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
672 -|R|0 – FF.f (Hex)|R HH.h|
673 -|L|0 - 73FF.f (Hex)|L HHHH.h|
674 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
675 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
676 -H1H2H3H4 Module main number
677 -
678 -H1: Remote number
679 -
680 -H2: Unit number
681 -
682 -H3: Slot number
683 -
684 -H4: Word number of module
685 -
686 -For example:WX21
687 -
688 -Word number of module is 1
689 -
690 -Slot number is 2
691 -
692 -Remote number and unit number are 0
693 -)))
694 -|WY|0 – FFFF (Hex)|WY H1H2H3H4
695 -|WR|0 – FFFF (Hex)|WR HHHH|
696 -|WL|0 - 73FF (Hex)|WL HHHH|
697 -|TC|0 - 2559|TC DDDD|
698 -
699 -**Communication settings in HMI**
700 -
701 -Enable HMI Ethernet in [Project Settings];
702 -
703 -(% style="text-align:center" %)
704 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
705 -
706 -Set PLC IP in [Device IP] settings;
707 -
708 -(% style="text-align:center" %)
709 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
710 -
711 -**PLC Configuration**
712 -
713 -Connect with PLC, select[Online mode];
714 -
715 -(% style="text-align:center" %)
716 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
717 -
718 -Set IP address, it is the same LAN parameters with HMI;
719 -
720 -(% style="text-align:center" %)
721 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
722 -
723 -3) Save PLC communication parameter, and restart PLC
724 -
725 -**PLC Monitor Mode**
726 -
727 -Connect with PLC and choose to “online” mode
728 -
729 -(% style="text-align:center" %)
730 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
731 -
732 -Open I/O monitor sheet1
733 -
734 -(% style="text-align:center" %)
735 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
736 -
737 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
738 -
739 -(% style="text-align:center" %)
740 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
741 -
742 -Enter the register address, click OK to view the value of the register.
743 -
744 -(% style="text-align:center" %)
745 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
746 -
747 -(% style="text-align:center" %)
748 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
749 -
750 -**✎Note:**
751 -
752 -* Both word registers and bit registers support even continuous read/write functions;
753 -* The range of registers is based on the specific PLC type;
754 -
755 -**Cable Wiring**
756 -
757 -(% style="text-align:center" %)
758 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
759 -
760 -= **IEC60870-5 104 Client** =
761 -
762 -**HMI Setting**
763 -
764 -(% class="table-bordered" %)
765 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
766 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
767 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
768 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
769 -
770 -**Address List**
771 -
772 -(% class="table-bordered" %)
773 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
774 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
775 -|(% style="width:461px" %)SCNA|0~~16777215.7
776 -|(% style="width:461px" %)DPTB|0~~16777215.7
777 -|(% style="width:461px" %)DCNA|0~~16777215.7
778 -|(% style="width:461px" %)METF|0~~16777215.7
779 -|(% style="width:461px" %)SENC|0~~16777215.7
780 -|(% style="width:461px" %)SENA|0~~16777215.7
781 -|(% style="width:461px" %)MENA|0~~16777215.7
782 -|(% style="width:461px" %)METD|0~~16777215.7
783 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
784 -|(% style="width:461px" %)SCNA|0~~16777215
785 -|(% style="width:461px" %)DPTB|0~~16777215
786 -|(% style="width:461px" %)DCNA|0~~16777215
787 -|(% style="width:461px" %)SENA|0~~16777215
788 -|(% style="width:461px" %)MENA|0~~16777215
789 -|(% style="width:461px" %)METD|0~~16777215
790 -|(% style="width:461px" %)INRO|0~~16777215
791 -|(% style="width:461px" %)TIMESYN|0~~16777215
792 -|(% style="width:461px" %)TIMEZ|0~~16777215
793 -|(% style="width:461px" %)NTP|0~~16777215
794 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
795 -|(% style="width:461px" %)SENC|0~~16777215
796 -
797 -**Address Configuration**
798 -
799 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
800 -
801 -(% style="text-align:center" %)
802 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
803 -
804 -(% style="text-align:center" %)
805 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
806 -
807 -Extended tag name
808 -
809 -Address range for the extended tag.
810 -
811 -**Communication Settings**
812 -
813 -Enable HMI Ethernet in [Project Settings];
814 -
815 -(% style="text-align:center" %)
816 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
817 -
818 -Set PLC IP in [Device IP] settings;
819 -
820 -(% style="text-align:center" %)
821 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
822 -
823 -**Cable Wiring**
824 -
825 -(% style="text-align:center" %)
826 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
827 -
828 -= **LG XGK FEnet Ethernet** =
829 -
830 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
831 -
832 -**HMI Settings**
833 -
834 -(% class="table-bordered" %)
835 -|**Items**|**Settings**|**Note**
836 -|Protocol|LG XGK FEnet(Ethernet)|
837 -|Connection|Ethernet|
838 -|Port No.|2004|
839 -
840 -**Address List**
841 -
842 -(% class="table-bordered" %)
843 -|**Type**|**Register**|**Range**|**Format**|**Note**
844 -|(% rowspan="14" %)Word|P|0~~2047|P d|
845 -|M|0~~2047|M d|
846 -|K|0~~2047|K d|
847 -|F|0~~2047|F d|
848 -|T|0~~2047|T d|
849 -|C|0~~2047|C d|
850 -|Z|0~~127|Z d|
851 -|S|0~~127|S d|
852 -|L|0~~11263|L d|
853 -|N|0~~21503|N d|
854 -|D|0~~32767|D d|
855 -|R|0~~32767|R d|
856 -|ZR|0~~65535|ZR d|
857 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
858 -
859 -**✎Note:**
860 -
861 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
862 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
863 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
864 -
865 -**Communication settings in HMI**
866 -
867 -Enable HMI Ethernet in [Project Settings];
868 -
869 -(% style="text-align:center" %)
870 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
871 -
872 -Set PLC IP in [Device IP] settings;
873 -
874 -(% style="text-align:center" %)
875 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
876 -
877 -**Cable Wiring**
878 -
879 879  = **Mitsubishi** =
880 880  
881 881  == **FX1S, 1N, 2N Series** ==
... ... @@ -2649,8 +2649,6 @@
2649 2649  
2650 2650  **✎Note:** COM3 only available in PI8000/PI9000 series.
2651 2651  
2652 -= =
2653 -
2654 2654  = **Printer** =
2655 2655  
2656 2656  == **TSPL label printer** ==
... ... @@ -2851,3 +2851,284 @@
2851 2851  
2852 2852  (% style="text-align:center" %)
2853 2853  [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]]
2572 +
2573 += **Barcode Scanner** =
2574 +
2575 +Supported: DELI 14880 barcode scanner
2576 +
2577 +**HMI Setting**
2578 +
2579 +|**Items**|**Settings**|**Note**
2580 +|Protocol|Barcode Scanner|
2581 +|Connection|USB|
2582 +
2583 +**Operating Procedures**
2584 +
2585 +Select [Barcode Scanner];
2586 +
2587 +(% style="text-align:center" %)
2588 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]]
2589 +
2590 +Set address for receiving;
2591 +
2592 +Set correct length;
2593 +
2594 +(% style="text-align:center" %)
2595 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]]
2596 +
2597 +**✎Note:**
2598 +
2599 +* The protocol uploads the information acquired by the USB scanner to the HMI;
2600 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
2601 +* Recommended model: DELI 14880 barcode scanner;
2602 +
2603 += **Hitachi EHV Series (Ethernet)** =
2604 +
2605 +Supported series: Hitachi EHV series
2606 +
2607 +**HMI Settings**
2608 +
2609 +(% class="table-bordered" %)
2610 +|**Items**|**Settings**|**Note**
2611 +|Protocol|Hitachi EHV series|
2612 +|Connection|Ethernet|
2613 +|Port No.|3004~~3007|
2614 +
2615 +**Address List**
2616 +
2617 +(% class="table-bordered" %)
2618 +|**Type**|**Register**|**Range**|**Format**|**Note**
2619 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
2620 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
2621 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
2622 +H1H2H3H4 Module main number
2623 +
2624 +H1: Remote number
2625 +
2626 +H2: Unit number
2627 +
2628 +H3: Slot number
2629 +
2630 +H4: Word number of Module
2631 +
2632 +H Sub number of Module
2633 +
2634 +For example:X21.3
2635 +
2636 +Slot number 2
2637 +
2638 +Word number of module is 1
2639 +
2640 +Bit number of module is 3
2641 +
2642 +Remote number and unit number are 0
2643 +)))
2644 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
2645 +|R|0 – FF.f (Hex)|R HH.h|
2646 +|L|0 - 73FF.f (Hex)|L HHHH.h|
2647 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
2648 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
2649 +H1H2H3H4 Module main number
2650 +
2651 +H1: Remote number
2652 +
2653 +H2: Unit number
2654 +
2655 +H3: Slot number
2656 +
2657 +H4: Word number of module
2658 +
2659 +For example:WX21
2660 +
2661 +Word number of module is 1
2662 +
2663 +Slot number is 2
2664 +
2665 +Remote number and unit number are 0
2666 +)))
2667 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
2668 +|WR|0 – FFFF (Hex)|WR HHHH|
2669 +|WL|0 - 73FF (Hex)|WL HHHH|
2670 +|TC|0 - 2559|TC DDDD|
2671 +
2672 +**Communication settings in HMI**
2673 +
2674 +Enable HMI Ethernet in [Project Settings];
2675 +
2676 +(% style="text-align:center" %)
2677 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2678 +
2679 +Set PLC IP in [Device IP] settings;
2680 +
2681 +(% style="text-align:center" %)
2682 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2683 +
2684 +**PLC Configuration**
2685 +
2686 +Connect with PLC, select[Online mode];
2687 +
2688 +(% style="text-align:center" %)
2689 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
2690 +
2691 +Set IP address, it is the same LAN parameters with HMI;
2692 +
2693 +(% style="text-align:center" %)
2694 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
2695 +
2696 +3) Save PLC communication parameter, and restart PLC
2697 +
2698 +**PLC Monitor Mode**
2699 +
2700 +Connect with PLC and choose to “online” mode
2701 +
2702 +(% style="text-align:center" %)
2703 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
2704 +
2705 +Open I/O monitor sheet1
2706 +
2707 +(% style="text-align:center" %)
2708 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
2709 +
2710 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
2711 +
2712 +(% style="text-align:center" %)
2713 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
2714 +
2715 +Enter the register address, click OK to view the value of the register.
2716 +
2717 +(% style="text-align:center" %)
2718 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2719 +
2720 +(% style="text-align:center" %)
2721 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2722 +
2723 +**✎Note:**
2724 +
2725 +* Both word registers and bit registers support even continuous read/write functions;
2726 +* The range of registers is based on the specific PLC type;
2727 +
2728 +**Cable Wiring**
2729 +
2730 +(% style="text-align:center" %)
2731 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2732 +
2733 += **IEC60870-5 104 Client** =
2734 +
2735 +**HMI Setting**
2736 +
2737 +(% class="table-bordered" %)
2738 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
2739 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
2740 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
2741 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
2742 +
2743 +**Address List**
2744 +
2745 +(% class="table-bordered" %)
2746 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
2747 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
2748 +|(% style="width:461px" %)SCNA|0~~16777215.7
2749 +|(% style="width:461px" %)DPTB|0~~16777215.7
2750 +|(% style="width:461px" %)DCNA|0~~16777215.7
2751 +|(% style="width:461px" %)METF|0~~16777215.7
2752 +|(% style="width:461px" %)SENC|0~~16777215.7
2753 +|(% style="width:461px" %)SENA|0~~16777215.7
2754 +|(% style="width:461px" %)MENA|0~~16777215.7
2755 +|(% style="width:461px" %)METD|0~~16777215.7
2756 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
2757 +|(% style="width:461px" %)SCNA|0~~16777215
2758 +|(% style="width:461px" %)DPTB|0~~16777215
2759 +|(% style="width:461px" %)DCNA|0~~16777215
2760 +|(% style="width:461px" %)SENA|0~~16777215
2761 +|(% style="width:461px" %)MENA|0~~16777215
2762 +|(% style="width:461px" %)METD|0~~16777215
2763 +|(% style="width:461px" %)INRO|0~~16777215
2764 +|(% style="width:461px" %)TIMESYN|0~~16777215
2765 +|(% style="width:461px" %)TIMEZ|0~~16777215
2766 +|(% style="width:461px" %)NTP|0~~16777215
2767 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
2768 +|(% style="width:461px" %)SENC|0~~16777215
2769 +
2770 +**Address Configuration**
2771 +
2772 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
2773 +
2774 +(% style="text-align:center" %)
2775 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
2776 +
2777 +(% style="text-align:center" %)
2778 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
2779 +
2780 +Extended tag name
2781 +
2782 +Address range for the extended tag.
2783 +
2784 +**Communication Settings**
2785 +
2786 +Enable HMI Ethernet in [Project Settings];
2787 +
2788 +(% style="text-align:center" %)
2789 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2790 +
2791 +Set PLC IP in [Device IP] settings;
2792 +
2793 +(% style="text-align:center" %)
2794 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
2795 +
2796 +**Cable Wiring**
2797 +
2798 +(% style="text-align:center" %)
2799 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2800 +
2801 += **LG XGK FEnet Ethernet** =
2802 +
2803 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
2804 +
2805 +**HMI Settings**
2806 +
2807 +(% class="table-bordered" %)
2808 +|**Items**|**Settings**|**Note**
2809 +|Protocol|LG XGK FEnet(Ethernet)|
2810 +|Connection|Ethernet|
2811 +|Port No.|2004|
2812 +
2813 +**Address List**
2814 +
2815 +(% class="table-bordered" %)
2816 +|**Type**|**Register**|**Range**|**Format**|**Note**
2817 +|(% rowspan="14" %)Word|P|0~~2047|P d|
2818 +|M|0~~2047|M d|
2819 +|K|0~~2047|K d|
2820 +|F|0~~2047|F d|
2821 +|T|0~~2047|T d|
2822 +|C|0~~2047|C d|
2823 +|Z|0~~127|Z d|
2824 +|S|0~~127|S d|
2825 +|L|0~~11263|L d|
2826 +|N|0~~21503|N d|
2827 +|D|0~~32767|D d|
2828 +|R|0~~32767|R d|
2829 +|ZR|0~~65535|ZR d|
2830 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
2831 +
2832 +**✎Note:**
2833 +
2834 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
2835 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
2836 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
2837 +
2838 +**Communication settings in HMI**
2839 +
2840 +Enable HMI Ethernet in [Project Settings];
2841 +
2842 +(% style="text-align:center" %)
2843 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2844 +
2845 +Set PLC IP in [Device IP] settings;
2846 +
2847 +(% style="text-align:center" %)
2848 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
2849 +
2850 +**Cable Wiring**
2851 +
2852 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]