Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -399,7 +399,6 @@ 399 399 400 400 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 401 401 402 - 403 403 **Software configuration of PLC** 404 404 405 405 **1)PLC programming software** ... ... @@ -471,7 +471,6 @@ 471 471 472 472 = Create communication with **Rockwell PLC** = 473 473 474 - 475 475 == **MicroLogix Protocol** == 476 476 477 477 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -587,295 +587,17 @@ 587 587 |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15 588 588 |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15 589 589 |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15 590 -| (% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**591 -| (% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255592 -| (% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF593 -| (% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF594 -| (% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF595 -| (% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF596 -| (% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF597 -| (% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF588 +|**PLC word address type**|**Address format**|**Address range** 589 +|S|ddd|S0 ~~ 255 590 +|TS|ffff|TS0 ~~ FFFF 591 +|TP|ffff|TP0 ~~ FFFF 592 +|CS|ffff|CS0 ~~ FFFF 593 +|CP|ffff|CP0 ~~ FFFF 594 +|N|ffff|N0 ~~ FFFF 595 +|F|ffff|F0 ~~ FFFF 598 598 599 -= **BarcodeScanner**=597 += = 600 600 601 -Supported: DELI 14880 barcode scanner 602 - 603 -**HMI Setting** 604 - 605 -(% class="table-bordered" %) 606 -|**Items**|**Settings**|**Note** 607 -|Protocol|Barcode Scanner| 608 -|Connection|USB| 609 - 610 -**Operating Procedures** 611 - 612 -Select [Barcode Scanner]; 613 - 614 -(% style="text-align:center" %) 615 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 616 - 617 -Set address for receiving; 618 - 619 -Set correct length; 620 - 621 -(% style="text-align:center" %) 622 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 623 - 624 -**✎Note:** 625 - 626 -* The protocol uploads the information acquired by the USB scanner to the HMI; 627 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 628 -* Recommended model: DELI 14880 barcode scanner; 629 - 630 -= **Hitachi EHV Series (Ethernet)** = 631 - 632 -Supported series: Hitachi EHV series 633 - 634 -**HMI Settings** 635 - 636 -(% class="table-bordered" %) 637 -|**Items**|**Settings**|**Note** 638 -|Protocol|Hitachi EHV series| 639 -|Connection|Ethernet| 640 -|Port No.|3004~~3007| 641 - 642 -**Address List** 643 - 644 -(% class="table-bordered" %) 645 -|**Type**|**Register**|**Range**|**Format**|**Note** 646 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 647 -|M|0 - 7FFF.f (Hex)|M HHHH.h| 648 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 649 -H1H2H3H4 Module main number 650 - 651 -H1: Remote number 652 - 653 -H2: Unit number 654 - 655 -H3: Slot number 656 - 657 -H4: Word number of Module 658 - 659 -H Sub number of Module 660 - 661 -For example:X21.3 662 - 663 -Slot number 2 664 - 665 -Word number of module is 1 666 - 667 -Bit number of module is 3 668 - 669 -Remote number and unit number are 0 670 -))) 671 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 672 -|R|0 – FF.f (Hex)|R HH.h| 673 -|L|0 - 73FF.f (Hex)|L HHHH.h| 674 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 675 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 676 -H1H2H3H4 Module main number 677 - 678 -H1: Remote number 679 - 680 -H2: Unit number 681 - 682 -H3: Slot number 683 - 684 -H4: Word number of module 685 - 686 -For example:WX21 687 - 688 -Word number of module is 1 689 - 690 -Slot number is 2 691 - 692 -Remote number and unit number are 0 693 -))) 694 -|WY|0 – FFFF (Hex)|WY H1H2H3H4 695 -|WR|0 – FFFF (Hex)|WR HHHH| 696 -|WL|0 - 73FF (Hex)|WL HHHH| 697 -|TC|0 - 2559|TC DDDD| 698 - 699 -**Communication settings in HMI** 700 - 701 -Enable HMI Ethernet in [Project Settings]; 702 - 703 -(% style="text-align:center" %) 704 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 705 - 706 -Set PLC IP in [Device IP] settings; 707 - 708 -(% style="text-align:center" %) 709 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 710 - 711 -**PLC Configuration** 712 - 713 -Connect with PLC, select[Online mode]; 714 - 715 -(% style="text-align:center" %) 716 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 717 - 718 -Set IP address, it is the same LAN parameters with HMI; 719 - 720 -(% style="text-align:center" %) 721 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 722 - 723 -3) Save PLC communication parameter, and restart PLC 724 - 725 -**PLC Monitor Mode** 726 - 727 -Connect with PLC and choose to “online” mode 728 - 729 -(% style="text-align:center" %) 730 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 731 - 732 -Open I/O monitor sheet1 733 - 734 -(% style="text-align:center" %) 735 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 736 - 737 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 738 - 739 -(% style="text-align:center" %) 740 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 741 - 742 -Enter the register address, click OK to view the value of the register. 743 - 744 -(% style="text-align:center" %) 745 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 746 - 747 -(% style="text-align:center" %) 748 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 749 - 750 -**✎Note:** 751 - 752 -* Both word registers and bit registers support even continuous read/write functions; 753 -* The range of registers is based on the specific PLC type; 754 - 755 -**Cable Wiring** 756 - 757 -(% style="text-align:center" %) 758 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 759 - 760 -= **IEC60870-5 104 Client** = 761 - 762 -**HMI Setting** 763 - 764 -(% class="table-bordered" %) 765 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 766 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 767 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 768 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 769 - 770 -**Address List** 771 - 772 -(% class="table-bordered" %) 773 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 774 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 775 -|(% style="width:461px" %)SCNA|0~~16777215.7 776 -|(% style="width:461px" %)DPTB|0~~16777215.7 777 -|(% style="width:461px" %)DCNA|0~~16777215.7 778 -|(% style="width:461px" %)METF|0~~16777215.7 779 -|(% style="width:461px" %)SENC|0~~16777215.7 780 -|(% style="width:461px" %)SENA|0~~16777215.7 781 -|(% style="width:461px" %)MENA|0~~16777215.7 782 -|(% style="width:461px" %)METD|0~~16777215.7 783 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 784 -|(% style="width:461px" %)SCNA|0~~16777215 785 -|(% style="width:461px" %)DPTB|0~~16777215 786 -|(% style="width:461px" %)DCNA|0~~16777215 787 -|(% style="width:461px" %)SENA|0~~16777215 788 -|(% style="width:461px" %)MENA|0~~16777215 789 -|(% style="width:461px" %)METD|0~~16777215 790 -|(% style="width:461px" %)INRO|0~~16777215 791 -|(% style="width:461px" %)TIMESYN|0~~16777215 792 -|(% style="width:461px" %)TIMEZ|0~~16777215 793 -|(% style="width:461px" %)NTP|0~~16777215 794 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 795 -|(% style="width:461px" %)SENC|0~~16777215 796 - 797 -**Address Configuration** 798 - 799 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 800 - 801 -(% style="text-align:center" %) 802 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 803 - 804 -(% style="text-align:center" %) 805 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 806 - 807 -Extended tag name 808 - 809 -Address range for the extended tag. 810 - 811 -**Communication Settings** 812 - 813 -Enable HMI Ethernet in [Project Settings]; 814 - 815 -(% style="text-align:center" %) 816 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 817 - 818 -Set PLC IP in [Device IP] settings; 819 - 820 -(% style="text-align:center" %) 821 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 822 - 823 -**Cable Wiring** 824 - 825 -(% style="text-align:center" %) 826 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 827 - 828 -= **LG XGK FEnet Ethernet** = 829 - 830 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 831 - 832 -**HMI Settings** 833 - 834 -(% class="table-bordered" %) 835 -|**Items**|**Settings**|**Note** 836 -|Protocol|LG XGK FEnet(Ethernet)| 837 -|Connection|Ethernet| 838 -|Port No.|2004| 839 - 840 -**Address List** 841 - 842 -(% class="table-bordered" %) 843 -|**Type**|**Register**|**Range**|**Format**|**Note** 844 -|(% rowspan="14" %)Word|P|0~~2047|P d| 845 -|M|0~~2047|M d| 846 -|K|0~~2047|K d| 847 -|F|0~~2047|F d| 848 -|T|0~~2047|T d| 849 -|C|0~~2047|C d| 850 -|Z|0~~127|Z d| 851 -|S|0~~127|S d| 852 -|L|0~~11263|L d| 853 -|N|0~~21503|N d| 854 -|D|0~~32767|D d| 855 -|R|0~~32767|R d| 856 -|ZR|0~~65535|ZR d| 857 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 858 - 859 -**✎Note:** 860 - 861 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 862 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 863 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 864 - 865 -**Communication settings in HMI** 866 - 867 -Enable HMI Ethernet in [Project Settings]; 868 - 869 -(% style="text-align:center" %) 870 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 871 - 872 -Set PLC IP in [Device IP] settings; 873 - 874 -(% style="text-align:center" %) 875 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 876 - 877 -**Cable Wiring** 878 - 879 879 = **Mitsubishi** = 880 880 881 881 == **FX1S, 1N, 2N Series** == ... ... @@ -2649,8 +2649,6 @@ 2649 2649 2650 2650 **✎Note:** COM3 only available in PI8000/PI9000 series. 2651 2651 2652 -= = 2653 - 2654 2654 = **Printer** = 2655 2655 2656 2656 == **TSPL label printer** == ... ... @@ -2851,3 +2851,284 @@ 2851 2851 2852 2852 (% style="text-align:center" %) 2853 2853 [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]] 2572 + 2573 += **Barcode Scanner** = 2574 + 2575 +Supported: DELI 14880 barcode scanner 2576 + 2577 +**HMI Setting** 2578 + 2579 +|**Items**|**Settings**|**Note** 2580 +|Protocol|Barcode Scanner| 2581 +|Connection|USB| 2582 + 2583 +**Operating Procedures** 2584 + 2585 +Select [Barcode Scanner]; 2586 + 2587 +(% style="text-align:center" %) 2588 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 2589 + 2590 +Set address for receiving; 2591 + 2592 +Set correct length; 2593 + 2594 +(% style="text-align:center" %) 2595 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 2596 + 2597 +**✎Note:** 2598 + 2599 +* The protocol uploads the information acquired by the USB scanner to the HMI; 2600 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 2601 +* Recommended model: DELI 14880 barcode scanner; 2602 + 2603 += **Hitachi EHV Series (Ethernet)** = 2604 + 2605 +Supported series: Hitachi EHV series 2606 + 2607 +**HMI Settings** 2608 + 2609 +(% class="table-bordered" %) 2610 +|**Items**|**Settings**|**Note** 2611 +|Protocol|Hitachi EHV series| 2612 +|Connection|Ethernet| 2613 +|Port No.|3004~~3007| 2614 + 2615 +**Address List** 2616 + 2617 +(% class="table-bordered" %) 2618 +|**Type**|**Register**|**Range**|**Format**|**Note** 2619 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 2620 +|M|0 - 7FFF.f (Hex)|M HHHH.h| 2621 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 2622 +H1H2H3H4 Module main number 2623 + 2624 +H1: Remote number 2625 + 2626 +H2: Unit number 2627 + 2628 +H3: Slot number 2629 + 2630 +H4: Word number of Module 2631 + 2632 +H Sub number of Module 2633 + 2634 +For example:X21.3 2635 + 2636 +Slot number 2 2637 + 2638 +Word number of module is 1 2639 + 2640 +Bit number of module is 3 2641 + 2642 +Remote number and unit number are 0 2643 +))) 2644 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 2645 +|R|0 – FF.f (Hex)|R HH.h| 2646 +|L|0 - 73FF.f (Hex)|L HHHH.h| 2647 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 2648 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 2649 +H1H2H3H4 Module main number 2650 + 2651 +H1: Remote number 2652 + 2653 +H2: Unit number 2654 + 2655 +H3: Slot number 2656 + 2657 +H4: Word number of module 2658 + 2659 +For example:WX21 2660 + 2661 +Word number of module is 1 2662 + 2663 +Slot number is 2 2664 + 2665 +Remote number and unit number are 0 2666 +))) 2667 +|WY|0 – FFFF (Hex)|WY H1H2H3H4 2668 +|WR|0 – FFFF (Hex)|WR HHHH| 2669 +|WL|0 - 73FF (Hex)|WL HHHH| 2670 +|TC|0 - 2559|TC DDDD| 2671 + 2672 +**Communication settings in HMI** 2673 + 2674 +Enable HMI Ethernet in [Project Settings]; 2675 + 2676 +(% style="text-align:center" %) 2677 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2678 + 2679 +Set PLC IP in [Device IP] settings; 2680 + 2681 +(% style="text-align:center" %) 2682 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 2683 + 2684 +**PLC Configuration** 2685 + 2686 +Connect with PLC, select[Online mode]; 2687 + 2688 +(% style="text-align:center" %) 2689 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 2690 + 2691 +Set IP address, it is the same LAN parameters with HMI; 2692 + 2693 +(% style="text-align:center" %) 2694 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 2695 + 2696 +3) Save PLC communication parameter, and restart PLC 2697 + 2698 +**PLC Monitor Mode** 2699 + 2700 +Connect with PLC and choose to “online” mode 2701 + 2702 +(% style="text-align:center" %) 2703 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 2704 + 2705 +Open I/O monitor sheet1 2706 + 2707 +(% style="text-align:center" %) 2708 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 2709 + 2710 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 2711 + 2712 +(% style="text-align:center" %) 2713 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 2714 + 2715 +Enter the register address, click OK to view the value of the register. 2716 + 2717 +(% style="text-align:center" %) 2718 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2719 + 2720 +(% style="text-align:center" %) 2721 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2722 + 2723 +**✎Note:** 2724 + 2725 +* Both word registers and bit registers support even continuous read/write functions; 2726 +* The range of registers is based on the specific PLC type; 2727 + 2728 +**Cable Wiring** 2729 + 2730 +(% style="text-align:center" %) 2731 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2732 + 2733 += **IEC60870-5 104 Client** = 2734 + 2735 +**HMI Setting** 2736 + 2737 +(% class="table-bordered" %) 2738 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 2739 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 2740 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 2741 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 2742 + 2743 +**Address List** 2744 + 2745 +(% class="table-bordered" %) 2746 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 2747 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 2748 +|(% style="width:461px" %)SCNA|0~~16777215.7 2749 +|(% style="width:461px" %)DPTB|0~~16777215.7 2750 +|(% style="width:461px" %)DCNA|0~~16777215.7 2751 +|(% style="width:461px" %)METF|0~~16777215.7 2752 +|(% style="width:461px" %)SENC|0~~16777215.7 2753 +|(% style="width:461px" %)SENA|0~~16777215.7 2754 +|(% style="width:461px" %)MENA|0~~16777215.7 2755 +|(% style="width:461px" %)METD|0~~16777215.7 2756 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 2757 +|(% style="width:461px" %)SCNA|0~~16777215 2758 +|(% style="width:461px" %)DPTB|0~~16777215 2759 +|(% style="width:461px" %)DCNA|0~~16777215 2760 +|(% style="width:461px" %)SENA|0~~16777215 2761 +|(% style="width:461px" %)MENA|0~~16777215 2762 +|(% style="width:461px" %)METD|0~~16777215 2763 +|(% style="width:461px" %)INRO|0~~16777215 2764 +|(% style="width:461px" %)TIMESYN|0~~16777215 2765 +|(% style="width:461px" %)TIMEZ|0~~16777215 2766 +|(% style="width:461px" %)NTP|0~~16777215 2767 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 2768 +|(% style="width:461px" %)SENC|0~~16777215 2769 + 2770 +**Address Configuration** 2771 + 2772 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 2773 + 2774 +(% style="text-align:center" %) 2775 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 2776 + 2777 +(% style="text-align:center" %) 2778 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 2779 + 2780 +Extended tag name 2781 + 2782 +Address range for the extended tag. 2783 + 2784 +**Communication Settings** 2785 + 2786 +Enable HMI Ethernet in [Project Settings]; 2787 + 2788 +(% style="text-align:center" %) 2789 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2790 + 2791 +Set PLC IP in [Device IP] settings; 2792 + 2793 +(% style="text-align:center" %) 2794 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 2795 + 2796 +**Cable Wiring** 2797 + 2798 +(% style="text-align:center" %) 2799 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2800 + 2801 += **LG XGK FEnet Ethernet** = 2802 + 2803 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2804 + 2805 +**HMI Settings** 2806 + 2807 +(% class="table-bordered" %) 2808 +|**Items**|**Settings**|**Note** 2809 +|Protocol|LG XGK FEnet(Ethernet)| 2810 +|Connection|Ethernet| 2811 +|Port No.|2004| 2812 + 2813 +**Address List** 2814 + 2815 +(% class="table-bordered" %) 2816 +|**Type**|**Register**|**Range**|**Format**|**Note** 2817 +|(% rowspan="14" %)Word|P|0~~2047|P d| 2818 +|M|0~~2047|M d| 2819 +|K|0~~2047|K d| 2820 +|F|0~~2047|F d| 2821 +|T|0~~2047|T d| 2822 +|C|0~~2047|C d| 2823 +|Z|0~~127|Z d| 2824 +|S|0~~127|S d| 2825 +|L|0~~11263|L d| 2826 +|N|0~~21503|N d| 2827 +|D|0~~32767|D d| 2828 +|R|0~~32767|R d| 2829 +|ZR|0~~65535|ZR d| 2830 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 2831 + 2832 +**✎Note:** 2833 + 2834 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 2835 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 2836 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 2837 + 2838 +**Communication settings in HMI** 2839 + 2840 +Enable HMI Ethernet in [Project Settings]; 2841 + 2842 +(% style="text-align:center" %) 2843 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2844 + 2845 +Set PLC IP in [Device IP] settings; 2846 + 2847 +(% style="text-align:center" %) 2848 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 2849 + 2850 +**Cable Wiring** 2851 + 2852 +[[image:https://docs.we-con.com.cn/bin/download/PIStudio/12.PLC%20protocols/WebHome/12.PLC%20Protocol_html_2297240b57346b2a.png?width=401&height=170&rev=1.1||alt="12.可编程逻辑控制器Protocol_html_2297240b57346b2a.png" height="170" width="401"]]