Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -399,7 +399,6 @@ 399 399 400 400 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 401 401 402 - 403 403 **Software configuration of PLC** 404 404 405 405 **1)PLC programming software** ... ... @@ -471,7 +471,6 @@ 471 471 472 472 = Create communication with **Rockwell PLC** = 473 473 474 - 475 475 == **MicroLogix Protocol** == 476 476 477 477 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -596,255 +596,8 @@ 596 596 |(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF 597 597 |(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF 598 598 599 -= **HitachiEHVSeries (Ethernet)**=597 += = 600 600 601 -Supported series: Hitachi EHV series 602 - 603 -**HMI Settings** 604 - 605 -(% class="table-bordered" %) 606 -|**Items**|**Settings**|**Note** 607 -|Protocol|Hitachi EHV series| 608 -|Connection|Ethernet| 609 -|Port No.|3004~~3007| 610 - 611 -**Address List** 612 - 613 -(% class="table-bordered" %) 614 -|**Type**|**Register**|**Range**|**Format**|**Note** 615 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 616 -|M|0 - 7FFF.f (Hex)|M HHHH.h| 617 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 618 -H1H2H3H4 Module main number 619 - 620 -H1: Remote number 621 - 622 -H2: Unit number 623 - 624 -H3: Slot number 625 - 626 -H4: Word number of Module 627 - 628 -H Sub number of Module 629 - 630 -For example:X21.3 631 - 632 -Slot number 2 633 - 634 -Word number of module is 1 635 - 636 -Bit number of module is 3 637 - 638 -Remote number and unit number are 0 639 -))) 640 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 641 -|R|0 – FF.f (Hex)|R HH.h| 642 -|L|0 - 73FF.f (Hex)|L HHHH.h| 643 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 644 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 645 -H1H2H3H4 Module main number 646 - 647 -H1: Remote number 648 - 649 -H2: Unit number 650 - 651 -H3: Slot number 652 - 653 -H4: Word number of module 654 - 655 -For example:WX21 656 - 657 -Word number of module is 1 658 - 659 -Slot number is 2 660 - 661 -Remote number and unit number are 0 662 -))) 663 -|WY|0 – FFFF (Hex)|WY H1H2H3H4 664 -|WR|0 – FFFF (Hex)|WR HHHH| 665 -|WL|0 - 73FF (Hex)|WL HHHH| 666 -|TC|0 - 2559|TC DDDD| 667 - 668 -**Communication settings in HMI** 669 - 670 -Enable HMI Ethernet in [Project Settings]; 671 - 672 -(% style="text-align:center" %) 673 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 674 - 675 -Set PLC IP in [Device IP] settings; 676 - 677 -(% style="text-align:center" %) 678 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 679 - 680 -**PLC Configuration** 681 - 682 -Connect with PLC, select[Online mode]; 683 - 684 -(% style="text-align:center" %) 685 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 686 - 687 -Set IP address, it is the same LAN parameters with HMI; 688 - 689 -(% style="text-align:center" %) 690 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 691 - 692 -3) Save PLC communication parameter, and restart PLC 693 - 694 -**PLC Monitor Mode** 695 - 696 -Connect with PLC and choose to “online” mode 697 - 698 -(% style="text-align:center" %) 699 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 700 - 701 -Open I/O monitor sheet1 702 - 703 -(% style="text-align:center" %) 704 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 705 - 706 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 707 - 708 -(% style="text-align:center" %) 709 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 710 - 711 -Enter the register address, click OK to view the value of the register. 712 - 713 -(% style="text-align:center" %) 714 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 715 - 716 -(% style="text-align:center" %) 717 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 718 - 719 -**✎Note:** 720 - 721 -* Both word registers and bit registers support even continuous read/write functions; 722 -* The range of registers is based on the specific PLC type; 723 - 724 -**Cable Wiring** 725 - 726 -(% style="text-align:center" %) 727 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 728 - 729 -= **IEC60870-5 104 Client** = 730 - 731 -**HMI Setting** 732 - 733 -(% class="table-bordered" %) 734 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 735 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 736 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 737 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 738 - 739 -**Address List** 740 - 741 -(% class="table-bordered" %) 742 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 743 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 744 -|(% style="width:461px" %)SCNA|0~~16777215.7 745 -|(% style="width:461px" %)DPTB|0~~16777215.7 746 -|(% style="width:461px" %)DCNA|0~~16777215.7 747 -|(% style="width:461px" %)METF|0~~16777215.7 748 -|(% style="width:461px" %)SENC|0~~16777215.7 749 -|(% style="width:461px" %)SENA|0~~16777215.7 750 -|(% style="width:461px" %)MENA|0~~16777215.7 751 -|(% style="width:461px" %)METD|0~~16777215.7 752 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 753 -|(% style="width:461px" %)SCNA|0~~16777215 754 -|(% style="width:461px" %)DPTB|0~~16777215 755 -|(% style="width:461px" %)DCNA|0~~16777215 756 -|(% style="width:461px" %)SENA|0~~16777215 757 -|(% style="width:461px" %)MENA|0~~16777215 758 -|(% style="width:461px" %)METD|0~~16777215 759 -|(% style="width:461px" %)INRO|0~~16777215 760 -|(% style="width:461px" %)TIMESYN|0~~16777215 761 -|(% style="width:461px" %)TIMEZ|0~~16777215 762 -|(% style="width:461px" %)NTP|0~~16777215 763 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 764 -|(% style="width:461px" %)SENC|0~~16777215 765 - 766 -**Address Configuration** 767 - 768 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 769 - 770 -(% style="text-align:center" %) 771 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 772 - 773 -(% style="text-align:center" %) 774 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 775 - 776 -Extended tag name 777 - 778 -Address range for the extended tag. 779 - 780 -**Communication Settings** 781 - 782 -Enable HMI Ethernet in [Project Settings]; 783 - 784 -(% style="text-align:center" %) 785 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 786 - 787 -Set PLC IP in [Device IP] settings; 788 - 789 -(% style="text-align:center" %) 790 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 791 - 792 -**Cable Wiring** 793 - 794 -(% style="text-align:center" %) 795 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 796 - 797 -= **LG XGK FEnet Ethernet** = 798 - 799 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 800 - 801 -**HMI Settings** 802 - 803 -(% class="table-bordered" %) 804 -|**Items**|**Settings**|**Note** 805 -|Protocol|LG XGK FEnet(Ethernet)| 806 -|Connection|Ethernet| 807 -|Port No.|2004| 808 - 809 -**Address List** 810 - 811 -(% class="table-bordered" %) 812 -|**Type**|**Register**|**Range**|**Format**|**Note** 813 -|(% rowspan="14" %)Word|P|0~~2047|P d| 814 -|M|0~~2047|M d| 815 -|K|0~~2047|K d| 816 -|F|0~~2047|F d| 817 -|T|0~~2047|T d| 818 -|C|0~~2047|C d| 819 -|Z|0~~127|Z d| 820 -|S|0~~127|S d| 821 -|L|0~~11263|L d| 822 -|N|0~~21503|N d| 823 -|D|0~~32767|D d| 824 -|R|0~~32767|R d| 825 -|ZR|0~~65535|ZR d| 826 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 827 - 828 -**✎Note:** 829 - 830 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 831 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 832 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 833 - 834 -**Communication settings in HMI** 835 - 836 -Enable HMI Ethernet in [Project Settings]; 837 - 838 -(% style="text-align:center" %) 839 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 840 - 841 -Set PLC IP in [Device IP] settings; 842 - 843 -(% style="text-align:center" %) 844 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 845 - 846 -**Cable Wiring** 847 - 848 848 = **Mitsubishi** = 849 849 850 850 == **FX1S, 1N, 2N Series** == ... ... @@ -2618,8 +2618,6 @@ 2618 2618 2619 2619 **✎Note:** COM3 only available in PI8000/PI9000 series. 2620 2620 2621 -= = 2622 - 2623 2623 = **Printer** = 2624 2624 2625 2625 == **TSPL label printer** == ... ... @@ -2820,3 +2820,283 @@ 2820 2820 2821 2821 (% style="text-align:center" %) 2822 2822 [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]] 2572 + 2573 += **Barcode Scanner** = 2574 + 2575 +Supported: DELI 14880 barcode scanner 2576 + 2577 +**HMI Setting** 2578 + 2579 +|**Items**|**Settings**|**Note** 2580 +|Protocol|Barcode Scanner| 2581 +|Connection|USB| 2582 + 2583 +**Operating Procedures** 2584 + 2585 +Select [Barcode Scanner]; 2586 + 2587 +(% style="text-align:center" %) 2588 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 2589 + 2590 +Set address for receiving; 2591 + 2592 +Set correct length; 2593 + 2594 +(% style="text-align:center" %) 2595 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 2596 + 2597 +**✎Note:** 2598 + 2599 +* The protocol uploads the information acquired by the USB scanner to the HMI; 2600 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 2601 +* Recommended model: DELI 14880 barcode scanner; 2602 + 2603 + 2604 += **Hitachi EHV Series (Ethernet)** = 2605 + 2606 +Supported series: Hitachi EHV series 2607 + 2608 +**HMI Settings** 2609 + 2610 +(% class="table-bordered" %) 2611 +|**Items**|**Settings**|**Note** 2612 +|Protocol|Hitachi EHV series| 2613 +|Connection|Ethernet| 2614 +|Port No.|3004~~3007| 2615 + 2616 +**Address List** 2617 + 2618 +(% class="table-bordered" %) 2619 +|**Type**|**Register**|**Range**|**Format**|**Note** 2620 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 2621 +|M|0 - 7FFF.f (Hex)|M HHHH.h| 2622 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 2623 +H1H2H3H4 Module main number 2624 + 2625 +H1: Remote number 2626 + 2627 +H2: Unit number 2628 + 2629 +H3: Slot number 2630 + 2631 +H4: Word number of Module 2632 + 2633 +H Sub number of Module 2634 + 2635 +For example:X21.3 2636 + 2637 +Slot number 2 2638 + 2639 +Word number of module is 1 2640 + 2641 +Bit number of module is 3 2642 + 2643 +Remote number and unit number are 0 2644 +))) 2645 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 2646 +|R|0 – FF.f (Hex)|R HH.h| 2647 +|L|0 - 73FF.f (Hex)|L HHHH.h| 2648 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 2649 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 2650 +H1H2H3H4 Module main number 2651 + 2652 +H1: Remote number 2653 + 2654 +H2: Unit number 2655 + 2656 +H3: Slot number 2657 + 2658 +H4: Word number of module 2659 + 2660 +For example:WX21 2661 + 2662 +Word number of module is 1 2663 + 2664 +Slot number is 2 2665 + 2666 +Remote number and unit number are 0 2667 +))) 2668 +|WY|0 – FFFF (Hex)|WY H1H2H3H4 2669 +|WR|0 – FFFF (Hex)|WR HHHH| 2670 +|WL|0 - 73FF (Hex)|WL HHHH| 2671 +|TC|0 - 2559|TC DDDD| 2672 + 2673 +**Communication settings in HMI** 2674 + 2675 +Enable HMI Ethernet in [Project Settings]; 2676 + 2677 +(% style="text-align:center" %) 2678 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2679 + 2680 +Set PLC IP in [Device IP] settings; 2681 + 2682 +(% style="text-align:center" %) 2683 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 2684 + 2685 +**PLC Configuration** 2686 + 2687 +Connect with PLC, select[Online mode]; 2688 + 2689 +(% style="text-align:center" %) 2690 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 2691 + 2692 +Set IP address, it is the same LAN parameters with HMI; 2693 + 2694 +(% style="text-align:center" %) 2695 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 2696 + 2697 +3) Save PLC communication parameter, and restart PLC 2698 + 2699 +**PLC Monitor Mode** 2700 + 2701 +Connect with PLC and choose to “online” mode 2702 + 2703 +(% style="text-align:center" %) 2704 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 2705 + 2706 +Open I/O monitor sheet1 2707 + 2708 +(% style="text-align:center" %) 2709 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 2710 + 2711 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 2712 + 2713 +(% style="text-align:center" %) 2714 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 2715 + 2716 +Enter the register address, click OK to view the value of the register. 2717 + 2718 +(% style="text-align:center" %) 2719 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2720 + 2721 +(% style="text-align:center" %) 2722 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2723 + 2724 +**✎Note:** 2725 + 2726 +* Both word registers and bit registers support even continuous read/write functions; 2727 +* The range of registers is based on the specific PLC type; 2728 + 2729 +**Cable Wiring** 2730 + 2731 +(% style="text-align:center" %) 2732 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2733 + 2734 += **IEC60870-5 104 Client** = 2735 + 2736 +**HMI Setting** 2737 + 2738 +(% class="table-bordered" %) 2739 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 2740 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 2741 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 2742 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 2743 + 2744 +**Address List** 2745 + 2746 +(% class="table-bordered" %) 2747 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 2748 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 2749 +|(% style="width:461px" %)SCNA|0~~16777215.7 2750 +|(% style="width:461px" %)DPTB|0~~16777215.7 2751 +|(% style="width:461px" %)DCNA|0~~16777215.7 2752 +|(% style="width:461px" %)METF|0~~16777215.7 2753 +|(% style="width:461px" %)SENC|0~~16777215.7 2754 +|(% style="width:461px" %)SENA|0~~16777215.7 2755 +|(% style="width:461px" %)MENA|0~~16777215.7 2756 +|(% style="width:461px" %)METD|0~~16777215.7 2757 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 2758 +|(% style="width:461px" %)SCNA|0~~16777215 2759 +|(% style="width:461px" %)DPTB|0~~16777215 2760 +|(% style="width:461px" %)DCNA|0~~16777215 2761 +|(% style="width:461px" %)SENA|0~~16777215 2762 +|(% style="width:461px" %)MENA|0~~16777215 2763 +|(% style="width:461px" %)METD|0~~16777215 2764 +|(% style="width:461px" %)INRO|0~~16777215 2765 +|(% style="width:461px" %)TIMESYN|0~~16777215 2766 +|(% style="width:461px" %)TIMEZ|0~~16777215 2767 +|(% style="width:461px" %)NTP|0~~16777215 2768 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 2769 +|(% style="width:461px" %)SENC|0~~16777215 2770 + 2771 +**Address Configuration** 2772 + 2773 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 2774 + 2775 +(% style="text-align:center" %) 2776 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 2777 + 2778 +(% style="text-align:center" %) 2779 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 2780 + 2781 +Extended tag name 2782 + 2783 +Address range for the extended tag. 2784 + 2785 +**Communication Settings** 2786 + 2787 +Enable HMI Ethernet in [Project Settings]; 2788 + 2789 +(% style="text-align:center" %) 2790 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2791 + 2792 +Set PLC IP in [Device IP] settings; 2793 + 2794 +(% style="text-align:center" %) 2795 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 2796 + 2797 +**Cable Wiring** 2798 + 2799 +(% style="text-align:center" %) 2800 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2801 + 2802 += **LG XGK FEnet Ethernet** = 2803 + 2804 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2805 + 2806 +**HMI Settings** 2807 + 2808 +(% class="table-bordered" %) 2809 +|**Items**|**Settings**|**Note** 2810 +|Protocol|LG XGK FEnet(Ethernet)| 2811 +|Connection|Ethernet| 2812 +|Port No.|2004| 2813 + 2814 +**Address List** 2815 + 2816 +(% class="table-bordered" %) 2817 +|**Type**|**Register**|**Range**|**Format**|**Note** 2818 +|(% rowspan="14" %)Word|P|0~~2047|P d| 2819 +|M|0~~2047|M d| 2820 +|K|0~~2047|K d| 2821 +|F|0~~2047|F d| 2822 +|T|0~~2047|T d| 2823 +|C|0~~2047|C d| 2824 +|Z|0~~127|Z d| 2825 +|S|0~~127|S d| 2826 +|L|0~~11263|L d| 2827 +|N|0~~21503|N d| 2828 +|D|0~~32767|D d| 2829 +|R|0~~32767|R d| 2830 +|ZR|0~~65535|ZR d| 2831 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 2832 + 2833 +**✎Note:** 2834 + 2835 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 2836 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 2837 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 2838 + 2839 +**Communication settings in HMI** 2840 + 2841 +Enable HMI Ethernet in [Project Settings]; 2842 + 2843 +(% style="text-align:center" %) 2844 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2845 + 2846 +Set PLC IP in [Device IP] settings; 2847 + 2848 +(% style="text-align:center" %) 2849 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 2850 + 2851 +**Cable Wiring**