Changes for page 12 PLC Protocol OLD

Last modified by Mora Zhou on 2024/12/05 14:53

From version 75.1
edited by Ben
on 2022/08/29 14:17
Change comment: There is no comment for this version
To version 78.1
edited by Ben
on 2022/08/29 14:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -399,7 +399,6 @@
399 399  
400 400  (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring.
401 401  
402 -
403 403  **Software configuration of PLC**
404 404  
405 405  **1)PLC programming software**
... ... @@ -471,7 +471,6 @@
471 471  
472 472  = Create communication with **Rockwell PLC** =
473 473  
474 -
475 475  == **MicroLogix Protocol** ==
476 476  
477 477  MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5
... ... @@ -587,264 +587,17 @@
587 587  |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15
588 588  |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15
589 589  |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15
590 -|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range**
591 -|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255
592 -|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF
593 -|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF
594 -|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF
595 -|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF
596 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF
597 -|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF
588 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
589 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
590 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
591 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
592 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
593 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
594 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
595 +|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %)
598 598  
599 -= **Hitachi EHV Series (Ethernet)** =
597 += =
600 600  
601 -Supported series: Hitachi EHV series
602 -
603 -**HMI Settings**
604 -
605 -(% class="table-bordered" %)
606 -|**Items**|**Settings**|**Note**
607 -|Protocol|Hitachi EHV series|
608 -|Connection|Ethernet|
609 -|Port No.|3004~~3007|
610 -
611 -**Address List**
612 -
613 -(% class="table-bordered" %)
614 -|**Type**|**Register**|**Range**|**Format**|**Note**
615 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
616 -|M|0 - 7FFF.f (Hex)|M HHHH.h|
617 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
618 -H1H2H3H4 Module main number
619 -
620 -H1: Remote number
621 -
622 -H2: Unit number
623 -
624 -H3: Slot number
625 -
626 -H4: Word number of Module
627 -
628 -H Sub number of Module
629 -
630 -For example:X21.3
631 -
632 -Slot number 2
633 -
634 -Word number of module is 1
635 -
636 -Bit number of module is 3
637 -
638 -Remote number and unit number are 0
639 -)))
640 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
641 -|R|0 – FF.f (Hex)|R HH.h|
642 -|L|0 - 73FF.f (Hex)|L HHHH.h|
643 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
644 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
645 -H1H2H3H4 Module main number
646 -
647 -H1: Remote number
648 -
649 -H2: Unit number
650 -
651 -H3: Slot number
652 -
653 -H4: Word number of module
654 -
655 -For example:WX21
656 -
657 -Word number of module is 1
658 -
659 -Slot number is 2
660 -
661 -Remote number and unit number are 0
662 -)))
663 -|WY|0 – FFFF (Hex)|WY H1H2H3H4
664 -|WR|0 – FFFF (Hex)|WR HHHH|
665 -|WL|0 - 73FF (Hex)|WL HHHH|
666 -|TC|0 - 2559|TC DDDD|
667 -
668 -**Communication settings in HMI**
669 -
670 -Enable HMI Ethernet in [Project Settings];
671 -
672 -(% style="text-align:center" %)
673 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
674 -
675 -Set PLC IP in [Device IP] settings;
676 -
677 -(% style="text-align:center" %)
678 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
679 -
680 -**PLC Configuration**
681 -
682 -Connect with PLC, select[Online mode];
683 -
684 -(% style="text-align:center" %)
685 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
686 -
687 -Set IP address, it is the same LAN parameters with HMI;
688 -
689 -(% style="text-align:center" %)
690 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
691 -
692 -3) Save PLC communication parameter, and restart PLC
693 -
694 -**PLC Monitor Mode**
695 -
696 -Connect with PLC and choose to “online” mode
697 -
698 -(% style="text-align:center" %)
699 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
700 -
701 -Open I/O monitor sheet1
702 -
703 -(% style="text-align:center" %)
704 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
705 -
706 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
707 -
708 -(% style="text-align:center" %)
709 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
710 -
711 -Enter the register address, click OK to view the value of the register.
712 -
713 -(% style="text-align:center" %)
714 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
715 -
716 -(% style="text-align:center" %)
717 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
718 -
719 -**✎Note:**
720 -
721 -* Both word registers and bit registers support even continuous read/write functions;
722 -* The range of registers is based on the specific PLC type;
723 -
724 -**Cable Wiring**
725 -
726 -(% style="text-align:center" %)
727 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
728 -
729 -= **IEC60870-5 104 Client** =
730 -
731 -**HMI Setting**
732 -
733 -(% class="table-bordered" %)
734 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
735 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
736 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
737 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
738 -
739 -**Address List**
740 -
741 -(% class="table-bordered" %)
742 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
743 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
744 -|(% style="width:461px" %)SCNA|0~~16777215.7
745 -|(% style="width:461px" %)DPTB|0~~16777215.7
746 -|(% style="width:461px" %)DCNA|0~~16777215.7
747 -|(% style="width:461px" %)METF|0~~16777215.7
748 -|(% style="width:461px" %)SENC|0~~16777215.7
749 -|(% style="width:461px" %)SENA|0~~16777215.7
750 -|(% style="width:461px" %)MENA|0~~16777215.7
751 -|(% style="width:461px" %)METD|0~~16777215.7
752 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
753 -|(% style="width:461px" %)SCNA|0~~16777215
754 -|(% style="width:461px" %)DPTB|0~~16777215
755 -|(% style="width:461px" %)DCNA|0~~16777215
756 -|(% style="width:461px" %)SENA|0~~16777215
757 -|(% style="width:461px" %)MENA|0~~16777215
758 -|(% style="width:461px" %)METD|0~~16777215
759 -|(% style="width:461px" %)INRO|0~~16777215
760 -|(% style="width:461px" %)TIMESYN|0~~16777215
761 -|(% style="width:461px" %)TIMEZ|0~~16777215
762 -|(% style="width:461px" %)NTP|0~~16777215
763 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
764 -|(% style="width:461px" %)SENC|0~~16777215
765 -
766 -**Address Configuration**
767 -
768 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
769 -
770 -(% style="text-align:center" %)
771 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
772 -
773 -(% style="text-align:center" %)
774 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
775 -
776 -Extended tag name
777 -
778 -Address range for the extended tag.
779 -
780 -**Communication Settings**
781 -
782 -Enable HMI Ethernet in [Project Settings];
783 -
784 -(% style="text-align:center" %)
785 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
786 -
787 -Set PLC IP in [Device IP] settings;
788 -
789 -(% style="text-align:center" %)
790 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
791 -
792 -**Cable Wiring**
793 -
794 -(% style="text-align:center" %)
795 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
796 -
797 -= **LG XGK FEnet Ethernet** =
798 -
799 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
800 -
801 -**HMI Settings**
802 -
803 -(% class="table-bordered" %)
804 -|**Items**|**Settings**|**Note**
805 -|Protocol|LG XGK FEnet(Ethernet)|
806 -|Connection|Ethernet|
807 -|Port No.|2004|
808 -
809 -**Address List**
810 -
811 -(% class="table-bordered" %)
812 -|**Type**|**Register**|**Range**|**Format**|**Note**
813 -|(% rowspan="14" %)Word|P|0~~2047|P d|
814 -|M|0~~2047|M d|
815 -|K|0~~2047|K d|
816 -|F|0~~2047|F d|
817 -|T|0~~2047|T d|
818 -|C|0~~2047|C d|
819 -|Z|0~~127|Z d|
820 -|S|0~~127|S d|
821 -|L|0~~11263|L d|
822 -|N|0~~21503|N d|
823 -|D|0~~32767|D d|
824 -|R|0~~32767|R d|
825 -|ZR|0~~65535|ZR d|
826 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
827 -
828 -**✎Note:**
829 -
830 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
831 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
832 -* All bit registers are in the form of bits in word, and the range is the same as the word register;
833 -
834 -**Communication settings in HMI**
835 -
836 -Enable HMI Ethernet in [Project Settings];
837 -
838 -(% style="text-align:center" %)
839 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
840 -
841 -Set PLC IP in [Device IP] settings;
842 -
843 -(% style="text-align:center" %)
844 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
845 -
846 -**Cable Wiring**
847 -
848 848  = **Mitsubishi** =
849 849  
850 850  == **FX1S, 1N, 2N Series** ==
... ... @@ -2618,8 +2618,6 @@
2618 2618  
2619 2619  **✎Note:** COM3 only available in PI8000/PI9000 series.
2620 2620  
2621 -= =
2622 -
2623 2623  = **Printer** =
2624 2624  
2625 2625  == **TSPL label printer** ==
... ... @@ -2850,3 +2850,252 @@
2850 2850  * The protocol uploads the information acquired by the USB scanner to the HMI;
2851 2851  * The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object;
2852 2852  * Recommended model: DELI 14880 barcode scanner;
2602 +
2603 += **Hitachi EHV Series (Ethernet)** =
2604 +
2605 +Supported series: Hitachi EHV series
2606 +
2607 +**HMI Settings**
2608 +
2609 +(% class="table-bordered" %)
2610 +|**Items**|**Settings**|**Note**
2611 +|Protocol|Hitachi EHV series|
2612 +|Connection|Ethernet|
2613 +|Port No.|3004~~3007|
2614 +
2615 +**Address List**
2616 +
2617 +(% class="table-bordered" %)
2618 +|**Type**|**Register**|**Range**|**Format**|**Note**
2619 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD|
2620 +|M|0 - 7FFF.f (Hex)|M HHHH.h|
2621 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)(((
2622 +H1H2H3H4 Module main number
2623 +
2624 +H1: Remote number
2625 +
2626 +H2: Unit number
2627 +
2628 +H3: Slot number
2629 +
2630 +H4: Word number of Module
2631 +
2632 +H Sub number of Module
2633 +
2634 +For example:X21.3
2635 +
2636 +Slot number 2
2637 +
2638 +Word number of module is 1
2639 +
2640 +Bit number of module is 3
2641 +
2642 +Remote number and unit number are 0
2643 +)))
2644 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h
2645 +|R|0 – FF.f (Hex)|R HH.h|
2646 +|L|0 - 73FF.f (Hex)|L HHHH.h|
2647 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH|
2648 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)(((
2649 +H1H2H3H4 Module main number
2650 +
2651 +H1: Remote number
2652 +
2653 +H2: Unit number
2654 +
2655 +H3: Slot number
2656 +
2657 +H4: Word number of module
2658 +
2659 +For example:WX21
2660 +
2661 +Word number of module is 1
2662 +
2663 +Slot number is 2
2664 +
2665 +Remote number and unit number are 0
2666 +)))
2667 +|WY|0 – FFFF (Hex)|WY H1H2H3H4
2668 +|WR|0 – FFFF (Hex)|WR HHHH|
2669 +|WL|0 - 73FF (Hex)|WL HHHH|
2670 +|TC|0 - 2559|TC DDDD|
2671 +
2672 +**Communication settings in HMI**
2673 +
2674 +Enable HMI Ethernet in [Project Settings];
2675 +
2676 +(% style="text-align:center" %)
2677 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2678 +
2679 +Set PLC IP in [Device IP] settings;
2680 +
2681 +(% style="text-align:center" %)
2682 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]]
2683 +
2684 +**PLC Configuration**
2685 +
2686 +Connect with PLC, select[Online mode];
2687 +
2688 +(% style="text-align:center" %)
2689 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]]
2690 +
2691 +Set IP address, it is the same LAN parameters with HMI;
2692 +
2693 +(% style="text-align:center" %)
2694 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]]
2695 +
2696 +3) Save PLC communication parameter, and restart PLC
2697 +
2698 +**PLC Monitor Mode**
2699 +
2700 +Connect with PLC and choose to “online” mode
2701 +
2702 +(% style="text-align:center" %)
2703 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]]
2704 +
2705 +Open I/O monitor sheet1
2706 +
2707 +(% style="text-align:center" %)
2708 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]]
2709 +
2710 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected
2711 +
2712 +(% style="text-align:center" %)
2713 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]]
2714 +
2715 +Enter the register address, click OK to view the value of the register.
2716 +
2717 +(% style="text-align:center" %)
2718 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2719 +
2720 +(% style="text-align:center" %)
2721 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]]
2722 +
2723 +**✎Note:**
2724 +
2725 +* Both word registers and bit registers support even continuous read/write functions;
2726 +* The range of registers is based on the specific PLC type;
2727 +
2728 +**Cable Wiring**
2729 +
2730 +(% style="text-align:center" %)
2731 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2732 +
2733 += **IEC60870-5 104 Client** =
2734 +
2735 +**HMI Setting**
2736 +
2737 +(% class="table-bordered" %)
2738 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note**
2739 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %)
2740 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %)
2741 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %)
2742 +
2743 +**Address List**
2744 +
2745 +(% class="table-bordered" %)
2746 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range**
2747 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7
2748 +|(% style="width:461px" %)SCNA|0~~16777215.7
2749 +|(% style="width:461px" %)DPTB|0~~16777215.7
2750 +|(% style="width:461px" %)DCNA|0~~16777215.7
2751 +|(% style="width:461px" %)METF|0~~16777215.7
2752 +|(% style="width:461px" %)SENC|0~~16777215.7
2753 +|(% style="width:461px" %)SENA|0~~16777215.7
2754 +|(% style="width:461px" %)MENA|0~~16777215.7
2755 +|(% style="width:461px" %)METD|0~~16777215.7
2756 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215
2757 +|(% style="width:461px" %)SCNA|0~~16777215
2758 +|(% style="width:461px" %)DPTB|0~~16777215
2759 +|(% style="width:461px" %)DCNA|0~~16777215
2760 +|(% style="width:461px" %)SENA|0~~16777215
2761 +|(% style="width:461px" %)MENA|0~~16777215
2762 +|(% style="width:461px" %)METD|0~~16777215
2763 +|(% style="width:461px" %)INRO|0~~16777215
2764 +|(% style="width:461px" %)TIMESYN|0~~16777215
2765 +|(% style="width:461px" %)TIMEZ|0~~16777215
2766 +|(% style="width:461px" %)NTP|0~~16777215
2767 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215
2768 +|(% style="width:461px" %)SENC|0~~16777215
2769 +
2770 +**Address Configuration**
2771 +
2772 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable.
2773 +
2774 +(% style="text-align:center" %)
2775 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]]
2776 +
2777 +(% style="text-align:center" %)
2778 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]]
2779 +
2780 +Extended tag name
2781 +
2782 +Address range for the extended tag.
2783 +
2784 +**Communication Settings**
2785 +
2786 +Enable HMI Ethernet in [Project Settings];
2787 +
2788 +(% style="text-align:center" %)
2789 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2790 +
2791 +Set PLC IP in [Device IP] settings;
2792 +
2793 +(% style="text-align:center" %)
2794 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]]
2795 +
2796 +**Cable Wiring**
2797 +
2798 +(% style="text-align:center" %)
2799 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]]
2800 +
2801 += **LG XGK FEnet Ethernet** =
2802 +
2803 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module
2804 +
2805 +**HMI Settings**
2806 +
2807 +(% class="table-bordered" %)
2808 +|**Items**|**Settings**|**Note**
2809 +|Protocol|LG XGK FEnet(Ethernet)|
2810 +|Connection|Ethernet|
2811 +|Port No.|2004|
2812 +
2813 +**Address List**
2814 +
2815 +(% class="table-bordered" %)
2816 +|**Type**|**Register**|**Range**|**Format**|**Note**
2817 +|(% rowspan="14" %)Word|P|0~~2047|P d|
2818 +|M|0~~2047|M d|
2819 +|K|0~~2047|K d|
2820 +|F|0~~2047|F d|
2821 +|T|0~~2047|T d|
2822 +|C|0~~2047|C d|
2823 +|Z|0~~127|Z d|
2824 +|S|0~~127|S d|
2825 +|L|0~~11263|L d|
2826 +|N|0~~21503|N d|
2827 +|D|0~~32767|D d|
2828 +|R|0~~32767|R d|
2829 +|ZR|0~~65535|ZR d|
2830 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31
2831 +
2832 +**✎Note:**
2833 +
2834 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC;
2835 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC;
2836 +* All bit registers are in the form of bits in word, and the range is the same as the word register;
2837 +
2838 +**Communication settings in HMI**
2839 +
2840 +Enable HMI Ethernet in [Project Settings];
2841 +
2842 +(% style="text-align:center" %)
2843 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]]
2844 +
2845 +Set PLC IP in [Device IP] settings;
2846 +
2847 +(% style="text-align:center" %)
2848 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]]
2849 +
2850 +**Cable Wiring**