Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -399,6 +399,7 @@ 399 399 400 400 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 401 401 402 + 402 402 **Software configuration of PLC** 403 403 404 404 **1)PLC programming software** ... ... @@ -470,6 +470,7 @@ 470 470 471 471 = Create communication with **Rockwell PLC** = 472 472 474 + 473 473 == **MicroLogix Protocol** == 474 474 475 475 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -594,8 +594,255 @@ 594 594 |(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF 595 595 |(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF 596 596 597 -= = 599 += **Hitachi EHV Series (Ethernet)** = 598 598 601 +Supported series: Hitachi EHV series 602 + 603 +**HMI Settings** 604 + 605 +(% class="table-bordered" %) 606 +|**Items**|**Settings**|**Note** 607 +|Protocol|Hitachi EHV series| 608 +|Connection|Ethernet| 609 +|Port No.|3004~~3007| 610 + 611 +**Address List** 612 + 613 +(% class="table-bordered" %) 614 +|**Type**|**Register**|**Range**|**Format**|**Note** 615 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 616 +|M|0 - 7FFF.f (Hex)|M HHHH.h| 617 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 618 +H1H2H3H4 Module main number 619 + 620 +H1: Remote number 621 + 622 +H2: Unit number 623 + 624 +H3: Slot number 625 + 626 +H4: Word number of Module 627 + 628 +H Sub number of Module 629 + 630 +For example:X21.3 631 + 632 +Slot number 2 633 + 634 +Word number of module is 1 635 + 636 +Bit number of module is 3 637 + 638 +Remote number and unit number are 0 639 +))) 640 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 641 +|R|0 – FF.f (Hex)|R HH.h| 642 +|L|0 - 73FF.f (Hex)|L HHHH.h| 643 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 644 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 645 +H1H2H3H4 Module main number 646 + 647 +H1: Remote number 648 + 649 +H2: Unit number 650 + 651 +H3: Slot number 652 + 653 +H4: Word number of module 654 + 655 +For example:WX21 656 + 657 +Word number of module is 1 658 + 659 +Slot number is 2 660 + 661 +Remote number and unit number are 0 662 +))) 663 +|WY|0 – FFFF (Hex)|WY H1H2H3H4 664 +|WR|0 – FFFF (Hex)|WR HHHH| 665 +|WL|0 - 73FF (Hex)|WL HHHH| 666 +|TC|0 - 2559|TC DDDD| 667 + 668 +**Communication settings in HMI** 669 + 670 +Enable HMI Ethernet in [Project Settings]; 671 + 672 +(% style="text-align:center" %) 673 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 674 + 675 +Set PLC IP in [Device IP] settings; 676 + 677 +(% style="text-align:center" %) 678 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 679 + 680 +**PLC Configuration** 681 + 682 +Connect with PLC, select[Online mode]; 683 + 684 +(% style="text-align:center" %) 685 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 686 + 687 +Set IP address, it is the same LAN parameters with HMI; 688 + 689 +(% style="text-align:center" %) 690 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 691 + 692 +3) Save PLC communication parameter, and restart PLC 693 + 694 +**PLC Monitor Mode** 695 + 696 +Connect with PLC and choose to “online” mode 697 + 698 +(% style="text-align:center" %) 699 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 700 + 701 +Open I/O monitor sheet1 702 + 703 +(% style="text-align:center" %) 704 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 705 + 706 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 707 + 708 +(% style="text-align:center" %) 709 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 710 + 711 +Enter the register address, click OK to view the value of the register. 712 + 713 +(% style="text-align:center" %) 714 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 715 + 716 +(% style="text-align:center" %) 717 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 718 + 719 +**✎Note:** 720 + 721 +* Both word registers and bit registers support even continuous read/write functions; 722 +* The range of registers is based on the specific PLC type; 723 + 724 +**Cable Wiring** 725 + 726 +(% style="text-align:center" %) 727 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 728 + 729 += **IEC60870-5 104 Client** = 730 + 731 +**HMI Setting** 732 + 733 +(% class="table-bordered" %) 734 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 735 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 736 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 737 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 738 + 739 +**Address List** 740 + 741 +(% class="table-bordered" %) 742 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 743 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 744 +|(% style="width:461px" %)SCNA|0~~16777215.7 745 +|(% style="width:461px" %)DPTB|0~~16777215.7 746 +|(% style="width:461px" %)DCNA|0~~16777215.7 747 +|(% style="width:461px" %)METF|0~~16777215.7 748 +|(% style="width:461px" %)SENC|0~~16777215.7 749 +|(% style="width:461px" %)SENA|0~~16777215.7 750 +|(% style="width:461px" %)MENA|0~~16777215.7 751 +|(% style="width:461px" %)METD|0~~16777215.7 752 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 753 +|(% style="width:461px" %)SCNA|0~~16777215 754 +|(% style="width:461px" %)DPTB|0~~16777215 755 +|(% style="width:461px" %)DCNA|0~~16777215 756 +|(% style="width:461px" %)SENA|0~~16777215 757 +|(% style="width:461px" %)MENA|0~~16777215 758 +|(% style="width:461px" %)METD|0~~16777215 759 +|(% style="width:461px" %)INRO|0~~16777215 760 +|(% style="width:461px" %)TIMESYN|0~~16777215 761 +|(% style="width:461px" %)TIMEZ|0~~16777215 762 +|(% style="width:461px" %)NTP|0~~16777215 763 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 764 +|(% style="width:461px" %)SENC|0~~16777215 765 + 766 +**Address Configuration** 767 + 768 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 769 + 770 +(% style="text-align:center" %) 771 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 772 + 773 +(% style="text-align:center" %) 774 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 775 + 776 +Extended tag name 777 + 778 +Address range for the extended tag. 779 + 780 +**Communication Settings** 781 + 782 +Enable HMI Ethernet in [Project Settings]; 783 + 784 +(% style="text-align:center" %) 785 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 786 + 787 +Set PLC IP in [Device IP] settings; 788 + 789 +(% style="text-align:center" %) 790 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 791 + 792 +**Cable Wiring** 793 + 794 +(% style="text-align:center" %) 795 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 796 + 797 += **LG XGK FEnet Ethernet** = 798 + 799 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 800 + 801 +**HMI Settings** 802 + 803 +(% class="table-bordered" %) 804 +|**Items**|**Settings**|**Note** 805 +|Protocol|LG XGK FEnet(Ethernet)| 806 +|Connection|Ethernet| 807 +|Port No.|2004| 808 + 809 +**Address List** 810 + 811 +(% class="table-bordered" %) 812 +|**Type**|**Register**|**Range**|**Format**|**Note** 813 +|(% rowspan="14" %)Word|P|0~~2047|P d| 814 +|M|0~~2047|M d| 815 +|K|0~~2047|K d| 816 +|F|0~~2047|F d| 817 +|T|0~~2047|T d| 818 +|C|0~~2047|C d| 819 +|Z|0~~127|Z d| 820 +|S|0~~127|S d| 821 +|L|0~~11263|L d| 822 +|N|0~~21503|N d| 823 +|D|0~~32767|D d| 824 +|R|0~~32767|R d| 825 +|ZR|0~~65535|ZR d| 826 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 827 + 828 +**✎Note:** 829 + 830 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 831 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 832 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 833 + 834 +**Communication settings in HMI** 835 + 836 +Enable HMI Ethernet in [Project Settings]; 837 + 838 +(% style="text-align:center" %) 839 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 840 + 841 +Set PLC IP in [Device IP] settings; 842 + 843 +(% style="text-align:center" %) 844 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 845 + 846 +**Cable Wiring** 847 + 599 599 = **Mitsubishi** = 600 600 601 601 == **FX1S, 1N, 2N Series** == ... ... @@ -2369,6 +2369,8 @@ 2369 2369 2370 2370 **✎Note:** COM3 only available in PI8000/PI9000 series. 2371 2371 2621 += = 2622 + 2372 2372 = **Printer** = 2373 2373 2374 2374 == **TSPL label printer** == ... ... @@ -2569,283 +2569,3 @@ 2569 2569 2570 2570 (% style="text-align:center" %) 2571 2571 [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]] 2572 - 2573 -= **Barcode Scanner** = 2574 - 2575 -Supported: DELI 14880 barcode scanner 2576 - 2577 -**HMI Setting** 2578 - 2579 -|**Items**|**Settings**|**Note** 2580 -|Protocol|Barcode Scanner| 2581 -|Connection|USB| 2582 - 2583 -**Operating Procedures** 2584 - 2585 -Select [Barcode Scanner]; 2586 - 2587 -(% style="text-align:center" %) 2588 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 2589 - 2590 -Set address for receiving; 2591 - 2592 -Set correct length; 2593 - 2594 -(% style="text-align:center" %) 2595 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 2596 - 2597 -**✎Note:** 2598 - 2599 -* The protocol uploads the information acquired by the USB scanner to the HMI; 2600 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 2601 -* Recommended model: DELI 14880 barcode scanner; 2602 - 2603 - 2604 -= **Hitachi EHV Series (Ethernet)** = 2605 - 2606 -Supported series: Hitachi EHV series 2607 - 2608 -**HMI Settings** 2609 - 2610 -(% class="table-bordered" %) 2611 -|**Items**|**Settings**|**Note** 2612 -|Protocol|Hitachi EHV series| 2613 -|Connection|Ethernet| 2614 -|Port No.|3004~~3007| 2615 - 2616 -**Address List** 2617 - 2618 -(% class="table-bordered" %) 2619 -|**Type**|**Register**|**Range**|**Format**|**Note** 2620 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 2621 -|M|0 - 7FFF.f (Hex)|M HHHH.h| 2622 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 2623 -H1H2H3H4 Module main number 2624 - 2625 -H1: Remote number 2626 - 2627 -H2: Unit number 2628 - 2629 -H3: Slot number 2630 - 2631 -H4: Word number of Module 2632 - 2633 -H Sub number of Module 2634 - 2635 -For example:X21.3 2636 - 2637 -Slot number 2 2638 - 2639 -Word number of module is 1 2640 - 2641 -Bit number of module is 3 2642 - 2643 -Remote number and unit number are 0 2644 -))) 2645 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 2646 -|R|0 – FF.f (Hex)|R HH.h| 2647 -|L|0 - 73FF.f (Hex)|L HHHH.h| 2648 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 2649 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 2650 -H1H2H3H4 Module main number 2651 - 2652 -H1: Remote number 2653 - 2654 -H2: Unit number 2655 - 2656 -H3: Slot number 2657 - 2658 -H4: Word number of module 2659 - 2660 -For example:WX21 2661 - 2662 -Word number of module is 1 2663 - 2664 -Slot number is 2 2665 - 2666 -Remote number and unit number are 0 2667 -))) 2668 -|WY|0 – FFFF (Hex)|WY H1H2H3H4 2669 -|WR|0 – FFFF (Hex)|WR HHHH| 2670 -|WL|0 - 73FF (Hex)|WL HHHH| 2671 -|TC|0 - 2559|TC DDDD| 2672 - 2673 -**Communication settings in HMI** 2674 - 2675 -Enable HMI Ethernet in [Project Settings]; 2676 - 2677 -(% style="text-align:center" %) 2678 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2679 - 2680 -Set PLC IP in [Device IP] settings; 2681 - 2682 -(% style="text-align:center" %) 2683 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 2684 - 2685 -**PLC Configuration** 2686 - 2687 -Connect with PLC, select[Online mode]; 2688 - 2689 -(% style="text-align:center" %) 2690 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 2691 - 2692 -Set IP address, it is the same LAN parameters with HMI; 2693 - 2694 -(% style="text-align:center" %) 2695 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 2696 - 2697 -3) Save PLC communication parameter, and restart PLC 2698 - 2699 -**PLC Monitor Mode** 2700 - 2701 -Connect with PLC and choose to “online” mode 2702 - 2703 -(% style="text-align:center" %) 2704 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 2705 - 2706 -Open I/O monitor sheet1 2707 - 2708 -(% style="text-align:center" %) 2709 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 2710 - 2711 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 2712 - 2713 -(% style="text-align:center" %) 2714 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 2715 - 2716 -Enter the register address, click OK to view the value of the register. 2717 - 2718 -(% style="text-align:center" %) 2719 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2720 - 2721 -(% style="text-align:center" %) 2722 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2723 - 2724 -**✎Note:** 2725 - 2726 -* Both word registers and bit registers support even continuous read/write functions; 2727 -* The range of registers is based on the specific PLC type; 2728 - 2729 -**Cable Wiring** 2730 - 2731 -(% style="text-align:center" %) 2732 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2733 - 2734 -= **IEC60870-5 104 Client** = 2735 - 2736 -**HMI Setting** 2737 - 2738 -(% class="table-bordered" %) 2739 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 2740 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 2741 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 2742 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 2743 - 2744 -**Address List** 2745 - 2746 -(% class="table-bordered" %) 2747 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 2748 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 2749 -|(% style="width:461px" %)SCNA|0~~16777215.7 2750 -|(% style="width:461px" %)DPTB|0~~16777215.7 2751 -|(% style="width:461px" %)DCNA|0~~16777215.7 2752 -|(% style="width:461px" %)METF|0~~16777215.7 2753 -|(% style="width:461px" %)SENC|0~~16777215.7 2754 -|(% style="width:461px" %)SENA|0~~16777215.7 2755 -|(% style="width:461px" %)MENA|0~~16777215.7 2756 -|(% style="width:461px" %)METD|0~~16777215.7 2757 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 2758 -|(% style="width:461px" %)SCNA|0~~16777215 2759 -|(% style="width:461px" %)DPTB|0~~16777215 2760 -|(% style="width:461px" %)DCNA|0~~16777215 2761 -|(% style="width:461px" %)SENA|0~~16777215 2762 -|(% style="width:461px" %)MENA|0~~16777215 2763 -|(% style="width:461px" %)METD|0~~16777215 2764 -|(% style="width:461px" %)INRO|0~~16777215 2765 -|(% style="width:461px" %)TIMESYN|0~~16777215 2766 -|(% style="width:461px" %)TIMEZ|0~~16777215 2767 -|(% style="width:461px" %)NTP|0~~16777215 2768 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 2769 -|(% style="width:461px" %)SENC|0~~16777215 2770 - 2771 -**Address Configuration** 2772 - 2773 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 2774 - 2775 -(% style="text-align:center" %) 2776 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 2777 - 2778 -(% style="text-align:center" %) 2779 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 2780 - 2781 -Extended tag name 2782 - 2783 -Address range for the extended tag. 2784 - 2785 -**Communication Settings** 2786 - 2787 -Enable HMI Ethernet in [Project Settings]; 2788 - 2789 -(% style="text-align:center" %) 2790 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2791 - 2792 -Set PLC IP in [Device IP] settings; 2793 - 2794 -(% style="text-align:center" %) 2795 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 2796 - 2797 -**Cable Wiring** 2798 - 2799 -(% style="text-align:center" %) 2800 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2801 - 2802 -= **LG XGK FEnet Ethernet** = 2803 - 2804 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2805 - 2806 -**HMI Settings** 2807 - 2808 -(% class="table-bordered" %) 2809 -|**Items**|**Settings**|**Note** 2810 -|Protocol|LG XGK FEnet(Ethernet)| 2811 -|Connection|Ethernet| 2812 -|Port No.|2004| 2813 - 2814 -**Address List** 2815 - 2816 -(% class="table-bordered" %) 2817 -|**Type**|**Register**|**Range**|**Format**|**Note** 2818 -|(% rowspan="14" %)Word|P|0~~2047|P d| 2819 -|M|0~~2047|M d| 2820 -|K|0~~2047|K d| 2821 -|F|0~~2047|F d| 2822 -|T|0~~2047|T d| 2823 -|C|0~~2047|C d| 2824 -|Z|0~~127|Z d| 2825 -|S|0~~127|S d| 2826 -|L|0~~11263|L d| 2827 -|N|0~~21503|N d| 2828 -|D|0~~32767|D d| 2829 -|R|0~~32767|R d| 2830 -|ZR|0~~65535|ZR d| 2831 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 2832 - 2833 -**✎Note:** 2834 - 2835 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 2836 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 2837 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 2838 - 2839 -**Communication settings in HMI** 2840 - 2841 -Enable HMI Ethernet in [Project Settings]; 2842 - 2843 -(% style="text-align:center" %) 2844 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2845 - 2846 -Set PLC IP in [Device IP] settings; 2847 - 2848 -(% style="text-align:center" %) 2849 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 2850 - 2851 -**Cable Wiring**