Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -399,6 +399,7 @@ 399 399 400 400 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 401 401 402 + 402 402 **Software configuration of PLC** 403 403 404 404 **1)PLC programming software** ... ... @@ -468,10 +468,69 @@ 468 468 469 469 The above are all the steps for establishing ethernet communication between Wecon HMI with LX5V PLC. 470 470 471 -= Createcommunication with **Rockwell PLC**=472 += = 472 472 473 -= =**MicroLogix Protocol** ==474 += **Allen-Bradley** = 474 474 476 +== **FreeTag Ethernet/IP (CompactLogix)** == 477 + 478 +Allen-Brandly CompactLogix 479 + 480 +**HMI Settings** 481 + 482 +(% class="table-bordered" %) 483 +|**Items**|**Settings**|**Note** 484 +|Protocol|Allen-Brandley FreeTag Ethernet/IP (CompactLogix)| 485 +|Connection|Ethernet| 486 +|Port No.|44818| 487 + 488 +**PLC Setting** 489 + 490 +Create new tags 491 + 492 +(% style="text-align:center" %) 493 +[[image:12.PLC Protocol_html_a748a27dcf7f1124.png||data-xwiki-image-style-alignment="center" height="411" width="700" class="img-thumbnail"]] 494 + 495 +Export tags to CSV file. ([Tools] » [Export] » [Tags and Logic Comments]) 496 + 497 +(% style="text-align:center" %) 498 +[[image:12.PLC Protocol_html_151379170bb8ff3e.png||data-xwiki-image-style-alignment="center" height="352" width="700" class="img-thumbnail"]] 499 + 500 +Import labels, please open [Communication] window and click [Import label]; 501 + 502 +Select csv file, all tags will be displayed as belows; 503 + 504 +(% style="text-align:center" %) 505 +[[image:12.PLC Protocol_html_af192e54dee96f38.png||data-xwiki-image-style-alignment="center" height="586" width="700" class="img-thumbnail"]] 506 + 507 +**✎Note:** 508 + 509 +Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format. 510 + 511 +(% style="text-align:center" %) 512 +[[image:12.PLC Protocol_html_33df1d63ebe53726.png||data-xwiki-image-style-alignment="center" height="206" width="700" class="img-thumbnail"]] 513 + 514 +The directory of changing system settings: [Control Panel] -> [Date, Time, Language,and Regional Options] -> [Change the format of numbers, dates, and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting. 515 + 516 +**Communication settings in HMI** 517 + 518 +Enable HMI Ethernet in [Project Settings]; 519 + 520 +(% style="text-align:center" %) 521 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="106" width="400" class="img-thumbnail"]] 522 + 523 +Set PLC IP in [Device IP] settings; 524 + 525 +(% style="text-align:center" %) 526 +[[image:12.PLC Protocol_html_27870d373581892e.png||data-xwiki-image-style-alignment="center" height="206" width="600" class="img-thumbnail"]] 527 + 528 +**Cable Wiring** 529 + 530 +(% style="text-align:center" %) 531 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="400" class="img-thumbnail"]] 532 + 533 +== **MicroLogix** == 534 + 475 475 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 476 476 477 477 **HMI Settings** ... ... @@ -507,95 +507,315 @@ 507 507 508 508 **Cable Wiring** 509 509 510 - 511 511 (% style="text-align:center" %) 512 512 [[image:12.PLC Protocol_html_58205bdf82c06d4.png||data-xwiki-image-style-alignment="center" height="307" width="500" class="img-thumbnail"]] 513 513 514 -== ** FreeTagEthernet/IP(CompactLogix)** ==573 +== **AB PLC address edit** == 515 515 516 -Allen-Bra ndly CompactLogix575 +The operational address is determined by the connection of Allen-Bradley PLC to HMI. For extension modules or other special conditions, refer to allen-Bradley PLC instruction manual. The following is an example of allen-bradley MicroLogix1200. 517 517 577 +* **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal). 578 +* **Bit address B:** The address ranges from 000.0 to fff.15. The first f from left to right represents the block number (hexadecimal); The second and third f from left to right represent the word address (hexadecimal). The value 0 to 15 after the decimal point reprensents the sub address (decimal). 579 +* **Word address S:** The word address ranges from 0 to 255 (decimal). 580 +* **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal). 581 + 582 +**✎Note: **Register address TP, CS, CP, N, F and TS address edit are same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table. 583 + 584 +|(% style="width:393px" %)**PLC bit address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range** 585 +|(% style="width:393px" %)I|(% style="width:350px" %)dd.dd|(% style="width:333px" %)I 0.0 ~~ 255.15 586 +|(% style="width:393px" %)O|(% style="width:350px" %)dd.dd|(% style="width:333px" %)O 0.0 ~~ 255.15 587 +|(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15 588 +|(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15 589 +|(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15 590 +|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range** 591 +|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255 592 +|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF 593 +|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF 594 +|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF 595 +|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF 596 +|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF 597 +|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF 598 + 599 += **Barcode Scanner** = 600 + 601 +Supported: DELI 14880 barcode scanner 602 + 603 +**HMI Setting** 604 + 605 +(% class="table-bordered" %) 606 +|**Items**|**Settings**|**Note** 607 +|Protocol|Barcode Scanner| 608 +|Connection|USB| 609 + 610 +**Operating Procedures** 611 + 612 +Select [Barcode Scanner]; 613 + 614 +(% style="text-align:center" %) 615 +[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 616 + 617 +Set address for receiving; 618 + 619 +Set correct length; 620 + 621 +(% style="text-align:center" %) 622 +[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 623 + 624 +**✎Note:** 625 + 626 +* The protocol uploads the information acquired by the USB scanner to the HMI; 627 +* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 628 +* Recommended model: DELI 14880 barcode scanner; 629 + 630 += **Hitachi EHV Series (Ethernet)** = 631 + 632 +Supported series: Hitachi EHV series 633 + 518 518 **HMI Settings** 519 519 520 520 (% class="table-bordered" %) 521 521 |**Items**|**Settings**|**Note** 522 -|Protocol| Allen-BrandleyFreeTagEthernet/IP (CompactLogix)|638 +|Protocol|Hitachi EHV series| 523 523 |Connection|Ethernet| 524 -|Port No.|4 4818|640 +|Port No.|3004~~3007| 525 525 526 -** PLC Setting**642 +**Address List** 527 527 528 -Create new tags 644 +(% class="table-bordered" %) 645 +|**Type**|**Register**|**Range**|**Format**|**Note** 646 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 647 +|M|0 - 7FFF.f (Hex)|M HHHH.h| 648 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 649 +H1H2H3H4 Module main number 529 529 651 +H1: Remote number 652 + 653 +H2: Unit number 654 + 655 +H3: Slot number 656 + 657 +H4: Word number of Module 658 + 659 +H Sub number of Module 660 + 661 +For example:X21.3 662 + 663 +Slot number 2 664 + 665 +Word number of module is 1 666 + 667 +Bit number of module is 3 668 + 669 +Remote number and unit number are 0 670 +))) 671 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 672 +|R|0 – FF.f (Hex)|R HH.h| 673 +|L|0 - 73FF.f (Hex)|L HHHH.h| 674 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 675 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 676 +H1H2H3H4 Module main number 677 + 678 +H1: Remote number 679 + 680 +H2: Unit number 681 + 682 +H3: Slot number 683 + 684 +H4: Word number of module 685 + 686 +For example:WX21 687 + 688 +Word number of module is 1 689 + 690 +Slot number is 2 691 + 692 +Remote number and unit number are 0 693 +))) 694 +|WY|0 – FFFF (Hex)|WY H1H2H3H4 695 +|WR|0 – FFFF (Hex)|WR HHHH| 696 +|WL|0 - 73FF (Hex)|WL HHHH| 697 +|TC|0 - 2559|TC DDDD| 698 + 699 +**Communication settings in HMI** 700 + 701 +Enable HMI Ethernet in [Project Settings]; 702 + 530 530 (% style="text-align:center" %) 531 -[[image:12.PLC Protocol_html_ a748a27dcf7f1124.png||data-xwiki-image-style-alignment="center" height="411" width="700" class="img-thumbnail"]]704 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 532 532 533 - Export tags to CSV file. ([Tools] » [Export]»[TagsandLogicComments])706 +Set PLC IP in [Device IP] settings; 534 534 535 535 (% style="text-align:center" %) 536 -[[image:12.PLC Protocol_html_ 151379170bb8ff3e.png||data-xwiki-image-style-alignment="center" height="352" width="700" class="img-thumbnail"]]709 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 537 537 538 - Importlabels, please open [Communication] window and click [Import label];711 +**PLC Configuration** 539 539 540 - Selectcsv file,all tagswill bedisplayedas belows;713 +Connect with PLC, select[Online mode]; 541 541 542 542 (% style="text-align:center" %) 543 -[[image:12.PLC Protocol_html_ af192e54dee96f38.png||data-xwiki-image-style-alignment="center" height="586" width="700" class="img-thumbnail"]]716 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 544 544 718 +Set IP address, it is the same LAN parameters with HMI; 719 + 720 +(% style="text-align:center" %) 721 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 722 + 723 +3) Save PLC communication parameter, and restart PLC 724 + 725 +**PLC Monitor Mode** 726 + 727 +Connect with PLC and choose to “online” mode 728 + 729 +(% style="text-align:center" %) 730 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 731 + 732 +Open I/O monitor sheet1 733 + 734 +(% style="text-align:center" %) 735 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 736 + 737 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 738 + 739 +(% style="text-align:center" %) 740 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 741 + 742 +Enter the register address, click OK to view the value of the register. 743 + 744 +(% style="text-align:center" %) 745 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 746 + 747 +(% style="text-align:center" %) 748 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 749 + 545 545 **✎Note:** 546 546 547 -Because in different region, the separation symbol is different, we suggest you check this before you want to import your tags. To open csv file as text format. 752 +* Both word registers and bit registers support even continuous read/write functions; 753 +* The range of registers is based on the specific PLC type; 548 548 755 +**Cable Wiring** 756 + 549 549 (% style="text-align:center" %) 550 -[[image:12.PLC Protocol_html_ 33df1d63ebe53726.png||data-xwiki-image-style-alignment="center" height="206" width="700" class="img-thumbnail"]]758 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 551 551 552 - Thedirectory of changing system settings: [Control Panel]->[Date,Time, Language,and RegionalOptions] -> [Changethe format ofnumbers, dates,and times]->[Customize]-> [List separator]. Please select [,] and export CSV file after setting.760 += **IEC60870-5 104 Client** = 553 553 554 -** Communicationsettings in HMI**762 +**HMI Setting** 555 555 764 +(% class="table-bordered" %) 765 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 766 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 767 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 768 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 769 + 770 +**Address List** 771 + 772 +(% class="table-bordered" %) 773 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 774 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 775 +|(% style="width:461px" %)SCNA|0~~16777215.7 776 +|(% style="width:461px" %)DPTB|0~~16777215.7 777 +|(% style="width:461px" %)DCNA|0~~16777215.7 778 +|(% style="width:461px" %)METF|0~~16777215.7 779 +|(% style="width:461px" %)SENC|0~~16777215.7 780 +|(% style="width:461px" %)SENA|0~~16777215.7 781 +|(% style="width:461px" %)MENA|0~~16777215.7 782 +|(% style="width:461px" %)METD|0~~16777215.7 783 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 784 +|(% style="width:461px" %)SCNA|0~~16777215 785 +|(% style="width:461px" %)DPTB|0~~16777215 786 +|(% style="width:461px" %)DCNA|0~~16777215 787 +|(% style="width:461px" %)SENA|0~~16777215 788 +|(% style="width:461px" %)MENA|0~~16777215 789 +|(% style="width:461px" %)METD|0~~16777215 790 +|(% style="width:461px" %)INRO|0~~16777215 791 +|(% style="width:461px" %)TIMESYN|0~~16777215 792 +|(% style="width:461px" %)TIMEZ|0~~16777215 793 +|(% style="width:461px" %)NTP|0~~16777215 794 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 795 +|(% style="width:461px" %)SENC|0~~16777215 796 + 797 +**Address Configuration** 798 + 799 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 800 + 801 +(% style="text-align:center" %) 802 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 803 + 804 +(% style="text-align:center" %) 805 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 806 + 807 +Extended tag name 808 + 809 +Address range for the extended tag. 810 + 811 +**Communication Settings** 812 + 556 556 Enable HMI Ethernet in [Project Settings]; 557 557 558 558 (% style="text-align:center" %) 559 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="10 6" width="400" class="img-thumbnail"]]816 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 560 560 561 561 Set PLC IP in [Device IP] settings; 562 562 563 563 (% style="text-align:center" %) 564 -[[image:12.PLC Protocol_html_ 27870d373581892e.png||data-xwiki-image-style-alignment="center" height="206" width="600" class="img-thumbnail"]]821 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 565 565 566 566 **Cable Wiring** 567 567 568 568 (% style="text-align:center" %) 569 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="40 0" class="img-thumbnail"]]826 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 570 570 571 -= =**AB PLCaddressedit** ==828 += **LG XGK FEnet Ethernet** = 572 572 573 - The operational address is determinedby theconnection of Allen-BradleyPLCtoHMI. For extension modulesorotherspecial conditions,referto allen-Bradley PLC instructionmanual. The following is an example of allen-bradley MicroLogix1200.830 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 574 574 575 -* **Bit address I:** The address ranges from 0.0 to 255.15. The value of the data before the decimal point ranges from 0 to 255 (decimal). The value from 0 to 15 after the decimal point is the sub address (decimal). 576 -* **Bit address B:** The address ranges from 000.0 to fff.15. The first f from left to right represents the block number (hexadecimal); The second and third f from left to right represent the word address (hexadecimal). The value 0 to 15 after the decimal point reprensents the sub address (decimal). 577 -* **Word address S:** The word address ranges from 0 to 255 (decimal). 578 -* **Word address TS:** The address ranges from 000.0 to ffff. The first and second f from left to right represents the block number (hexadecimal); The third and fourth f from left to right represent the word address (hexadecimal). 832 +**HMI Settings** 579 579 580 -**✎Note: **Register address TP, CS, CP, N, F and TS address edit are same. D indicates decimal, and F indicates hexadecimal. Different PLC models may support different registers. See the following table. 834 +(% class="table-bordered" %) 835 +|**Items**|**Settings**|**Note** 836 +|Protocol|LG XGK FEnet(Ethernet)| 837 +|Connection|Ethernet| 838 +|Port No.|2004| 581 581 582 -|(% style="width:393px" %)**PLC bit address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range** 583 -|(% style="width:393px" %)I|(% style="width:350px" %)dd.dd|(% style="width:333px" %)I 0.0 ~~ 255.15 584 -|(% style="width:393px" %)O|(% style="width:350px" %)dd.dd|(% style="width:333px" %)O 0.0 ~~ 255.15 585 -|(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15 586 -|(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15 587 -|(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15 588 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 589 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 590 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 591 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 592 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 593 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 594 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 595 -|(% style="width:393px" %) |(% style="width:350px" %) |(% style="width:333px" %) 840 +**Address List** 596 596 597 -= = 842 +(% class="table-bordered" %) 843 +|**Type**|**Register**|**Range**|**Format**|**Note** 844 +|(% rowspan="14" %)Word|P|0~~2047|P d| 845 +|M|0~~2047|M d| 846 +|K|0~~2047|K d| 847 +|F|0~~2047|F d| 848 +|T|0~~2047|T d| 849 +|C|0~~2047|C d| 850 +|Z|0~~127|Z d| 851 +|S|0~~127|S d| 852 +|L|0~~11263|L d| 853 +|N|0~~21503|N d| 854 +|D|0~~32767|D d| 855 +|R|0~~32767|R d| 856 +|ZR|0~~65535|ZR d| 857 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 598 598 859 +**✎Note:** 860 + 861 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 862 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 863 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 864 + 865 +**Communication settings in HMI** 866 + 867 +Enable HMI Ethernet in [Project Settings]; 868 + 869 +(% style="text-align:center" %) 870 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 871 + 872 +Set PLC IP in [Device IP] settings; 873 + 874 +(% style="text-align:center" %) 875 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 876 + 877 +**Cable Wiring** 878 + 599 599 = **Mitsubishi** = 600 600 601 601 == **FX1S, 1N, 2N Series** == ... ... @@ -2369,6 +2369,8 @@ 2369 2369 2370 2370 **✎Note:** COM3 only available in PI8000/PI9000 series. 2371 2371 2652 += = 2653 + 2372 2372 = **Printer** = 2373 2373 2374 2374 == **TSPL label printer** == ... ... @@ -2569,282 +2569,3 @@ 2569 2569 2570 2570 (% style="text-align:center" %) 2571 2571 [[image:image-20220817154212-1.jpeg||height="315" width="554" class="img-thumbnail"]] 2572 - 2573 -= **Barcode Scanner** = 2574 - 2575 -Supported: DELI 14880 barcode scanner 2576 - 2577 -**HMI Setting** 2578 - 2579 -|**Items**|**Settings**|**Note** 2580 -|Protocol|Barcode Scanner| 2581 -|Connection|USB| 2582 - 2583 -**Operating Procedures** 2584 - 2585 -Select [Barcode Scanner]; 2586 - 2587 -(% style="text-align:center" %) 2588 -[[image:12.PLC Protocol_html_55a3056357320966.png||data-xwiki-image-style-alignment="center" height="266" width="600" class="img-thumbnail"]] 2589 - 2590 -Set address for receiving; 2591 - 2592 -Set correct length; 2593 - 2594 -(% style="text-align:center" %) 2595 -[[image:12.PLC Protocol_html_30a4c9e9dd4db40b.png||data-xwiki-image-style-alignment="center" height="701" width="500" class="img-thumbnail"]] 2596 - 2597 -**✎Note:** 2598 - 2599 -* The protocol uploads the information acquired by the USB scanner to the HMI; 2600 -* The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 2601 -* Recommended model: DELI 14880 barcode scanner; 2602 - 2603 -= **Hitachi EHV Series (Ethernet)** = 2604 - 2605 -Supported series: Hitachi EHV series 2606 - 2607 -**HMI Settings** 2608 - 2609 -(% class="table-bordered" %) 2610 -|**Items**|**Settings**|**Note** 2611 -|Protocol|Hitachi EHV series| 2612 -|Connection|Ethernet| 2613 -|Port No.|3004~~3007| 2614 - 2615 -**Address List** 2616 - 2617 -(% class="table-bordered" %) 2618 -|**Type**|**Register**|**Range**|**Format**|**Note** 2619 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 2620 -|M|0 - 7FFF.f (Hex)|M HHHH.h| 2621 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 2622 -H1H2H3H4 Module main number 2623 - 2624 -H1: Remote number 2625 - 2626 -H2: Unit number 2627 - 2628 -H3: Slot number 2629 - 2630 -H4: Word number of Module 2631 - 2632 -H Sub number of Module 2633 - 2634 -For example:X21.3 2635 - 2636 -Slot number 2 2637 - 2638 -Word number of module is 1 2639 - 2640 -Bit number of module is 3 2641 - 2642 -Remote number and unit number are 0 2643 -))) 2644 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 2645 -|R|0 – FF.f (Hex)|R HH.h| 2646 -|L|0 - 73FF.f (Hex)|L HHHH.h| 2647 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 2648 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 2649 -H1H2H3H4 Module main number 2650 - 2651 -H1: Remote number 2652 - 2653 -H2: Unit number 2654 - 2655 -H3: Slot number 2656 - 2657 -H4: Word number of module 2658 - 2659 -For example:WX21 2660 - 2661 -Word number of module is 1 2662 - 2663 -Slot number is 2 2664 - 2665 -Remote number and unit number are 0 2666 -))) 2667 -|WY|0 – FFFF (Hex)|WY H1H2H3H4 2668 -|WR|0 – FFFF (Hex)|WR HHHH| 2669 -|WL|0 - 73FF (Hex)|WL HHHH| 2670 -|TC|0 - 2559|TC DDDD| 2671 - 2672 -**Communication settings in HMI** 2673 - 2674 -Enable HMI Ethernet in [Project Settings]; 2675 - 2676 -(% style="text-align:center" %) 2677 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2678 - 2679 -Set PLC IP in [Device IP] settings; 2680 - 2681 -(% style="text-align:center" %) 2682 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 2683 - 2684 -**PLC Configuration** 2685 - 2686 -Connect with PLC, select[Online mode]; 2687 - 2688 -(% style="text-align:center" %) 2689 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 2690 - 2691 -Set IP address, it is the same LAN parameters with HMI; 2692 - 2693 -(% style="text-align:center" %) 2694 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 2695 - 2696 -3) Save PLC communication parameter, and restart PLC 2697 - 2698 -**PLC Monitor Mode** 2699 - 2700 -Connect with PLC and choose to “online” mode 2701 - 2702 -(% style="text-align:center" %) 2703 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 2704 - 2705 -Open I/O monitor sheet1 2706 - 2707 -(% style="text-align:center" %) 2708 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 2709 - 2710 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 2711 - 2712 -(% style="text-align:center" %) 2713 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 2714 - 2715 -Enter the register address, click OK to view the value of the register. 2716 - 2717 -(% style="text-align:center" %) 2718 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2719 - 2720 -(% style="text-align:center" %) 2721 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2722 - 2723 -**✎Note:** 2724 - 2725 -* Both word registers and bit registers support even continuous read/write functions; 2726 -* The range of registers is based on the specific PLC type; 2727 - 2728 -**Cable Wiring** 2729 - 2730 -(% style="text-align:center" %) 2731 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2732 - 2733 -= **IEC60870-5 104 Client** = 2734 - 2735 -**HMI Setting** 2736 - 2737 -(% class="table-bordered" %) 2738 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 2739 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 2740 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 2741 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 2742 - 2743 -**Address List** 2744 - 2745 -(% class="table-bordered" %) 2746 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 2747 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 2748 -|(% style="width:461px" %)SCNA|0~~16777215.7 2749 -|(% style="width:461px" %)DPTB|0~~16777215.7 2750 -|(% style="width:461px" %)DCNA|0~~16777215.7 2751 -|(% style="width:461px" %)METF|0~~16777215.7 2752 -|(% style="width:461px" %)SENC|0~~16777215.7 2753 -|(% style="width:461px" %)SENA|0~~16777215.7 2754 -|(% style="width:461px" %)MENA|0~~16777215.7 2755 -|(% style="width:461px" %)METD|0~~16777215.7 2756 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 2757 -|(% style="width:461px" %)SCNA|0~~16777215 2758 -|(% style="width:461px" %)DPTB|0~~16777215 2759 -|(% style="width:461px" %)DCNA|0~~16777215 2760 -|(% style="width:461px" %)SENA|0~~16777215 2761 -|(% style="width:461px" %)MENA|0~~16777215 2762 -|(% style="width:461px" %)METD|0~~16777215 2763 -|(% style="width:461px" %)INRO|0~~16777215 2764 -|(% style="width:461px" %)TIMESYN|0~~16777215 2765 -|(% style="width:461px" %)TIMEZ|0~~16777215 2766 -|(% style="width:461px" %)NTP|0~~16777215 2767 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 2768 -|(% style="width:461px" %)SENC|0~~16777215 2769 - 2770 -**Address Configuration** 2771 - 2772 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 2773 - 2774 -(% style="text-align:center" %) 2775 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 2776 - 2777 -(% style="text-align:center" %) 2778 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 2779 - 2780 -Extended tag name 2781 - 2782 -Address range for the extended tag. 2783 - 2784 -**Communication Settings** 2785 - 2786 -Enable HMI Ethernet in [Project Settings]; 2787 - 2788 -(% style="text-align:center" %) 2789 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2790 - 2791 -Set PLC IP in [Device IP] settings; 2792 - 2793 -(% style="text-align:center" %) 2794 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 2795 - 2796 -**Cable Wiring** 2797 - 2798 -(% style="text-align:center" %) 2799 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2800 - 2801 -= **LG XGK FEnet Ethernet** = 2802 - 2803 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2804 - 2805 -**HMI Settings** 2806 - 2807 -(% class="table-bordered" %) 2808 -|**Items**|**Settings**|**Note** 2809 -|Protocol|LG XGK FEnet(Ethernet)| 2810 -|Connection|Ethernet| 2811 -|Port No.|2004| 2812 - 2813 -**Address List** 2814 - 2815 -(% class="table-bordered" %) 2816 -|**Type**|**Register**|**Range**|**Format**|**Note** 2817 -|(% rowspan="14" %)Word|P|0~~2047|P d| 2818 -|M|0~~2047|M d| 2819 -|K|0~~2047|K d| 2820 -|F|0~~2047|F d| 2821 -|T|0~~2047|T d| 2822 -|C|0~~2047|C d| 2823 -|Z|0~~127|Z d| 2824 -|S|0~~127|S d| 2825 -|L|0~~11263|L d| 2826 -|N|0~~21503|N d| 2827 -|D|0~~32767|D d| 2828 -|R|0~~32767|R d| 2829 -|ZR|0~~65535|ZR d| 2830 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 2831 - 2832 -**✎Note:** 2833 - 2834 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 2835 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 2836 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 2837 - 2838 -**Communication settings in HMI** 2839 - 2840 -Enable HMI Ethernet in [Project Settings]; 2841 - 2842 -(% style="text-align:center" %) 2843 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2844 - 2845 -Set PLC IP in [Device IP] settings; 2846 - 2847 -(% style="text-align:center" %) 2848 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 2849 - 2850 -**Cable Wiring**