Changes for page 12 PLC Protocol OLD
Last modified by Mora Zhou on 2024/12/05 14:53
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -399,6 +399,7 @@ 399 399 400 400 (% id="cke_bm_147709S" style="display:none" %) (%%)This example introduces the establishment of Ethernet communication between Wecon HMI and LX5V. It is introduced through three parts: PLC software configuration, HMI software configuration, and hardware wiring. 401 401 402 + 402 402 **Software configuration of PLC** 403 403 404 404 **1)PLC programming software** ... ... @@ -470,6 +470,7 @@ 470 470 471 471 = Create communication with **Rockwell PLC** = 472 472 474 + 473 473 == **MicroLogix Protocol** == 474 474 475 475 MicroLogix 1000/1100/1200/1400/1500; SLC 5/03 5/04 5/05 PLC-5 ... ... @@ -585,17 +585,264 @@ 585 585 |(% style="width:393px" %)B|(% style="width:350px" %)fff.dd|(% style="width:333px" %)B 000.0 ~~ fff.15 586 586 |(% style="width:393px" %)S|(% style="width:350px" %)dd.dd|(% style="width:333px" %)S 0.0 ~~ 255.15 587 587 |(% style="width:393px" %)N|(% style="width:350px" %)ffff.dd|(% style="width:333px" %)N 000.0 ~~ fff.15 588 -|**PLC word address type**|**Address format**|**Address range** 589 -|S|ddd|S0 ~~ 255 590 -|TS|ffff|TS0 ~~ FFFF 591 -|TP|ffff|TP0 ~~ FFFF 592 -|CS|ffff|CS0 ~~ FFFF 593 -|CP|ffff|CP0 ~~ FFFF 594 -|N|ffff|N0 ~~ FFFF 595 -|F|ffff|F0 ~~ FFFF 590 +|(% style="width:393px" %)**PLC word address type**|(% style="width:350px" %)**Address format**|(% style="width:333px" %)**Address range** 591 +|(% style="width:393px" %)S|(% style="width:350px" %)ddd|(% style="width:333px" %)S0 ~~ 255 592 +|(% style="width:393px" %)TS|(% style="width:350px" %)ffff|(% style="width:333px" %)TS0 ~~ FFFF 593 +|(% style="width:393px" %)TP|(% style="width:350px" %)ffff|(% style="width:333px" %)TP0 ~~ FFFF 594 +|(% style="width:393px" %)CS|(% style="width:350px" %)ffff|(% style="width:333px" %)CS0 ~~ FFFF 595 +|(% style="width:393px" %)CP|(% style="width:350px" %)ffff|(% style="width:333px" %)CP0 ~~ FFFF 596 +|(% style="width:393px" %)N|(% style="width:350px" %)ffff|(% style="width:333px" %)N0 ~~ FFFF 597 +|(% style="width:393px" %)F|(% style="width:350px" %)ffff|(% style="width:333px" %)F0 ~~ FFFF 596 596 597 -= = 599 += **Hitachi EHV Series (Ethernet)** = 598 598 601 +Supported series: Hitachi EHV series 602 + 603 +**HMI Settings** 604 + 605 +(% class="table-bordered" %) 606 +|**Items**|**Settings**|**Note** 607 +|Protocol|Hitachi EHV series| 608 +|Connection|Ethernet| 609 +|Port No.|3004~~3007| 610 + 611 +**Address List** 612 + 613 +(% class="table-bordered" %) 614 +|**Type**|**Register**|**Range**|**Format**|**Note** 615 +|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 616 +|M|0 - 7FFF.f (Hex)|M HHHH.h| 617 +|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 618 +H1H2H3H4 Module main number 619 + 620 +H1: Remote number 621 + 622 +H2: Unit number 623 + 624 +H3: Slot number 625 + 626 +H4: Word number of Module 627 + 628 +H Sub number of Module 629 + 630 +For example:X21.3 631 + 632 +Slot number 2 633 + 634 +Word number of module is 1 635 + 636 +Bit number of module is 3 637 + 638 +Remote number and unit number are 0 639 +))) 640 +|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 641 +|R|0 – FF.f (Hex)|R HH.h| 642 +|L|0 - 73FF.f (Hex)|L HHHH.h| 643 +|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 644 +|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 645 +H1H2H3H4 Module main number 646 + 647 +H1: Remote number 648 + 649 +H2: Unit number 650 + 651 +H3: Slot number 652 + 653 +H4: Word number of module 654 + 655 +For example:WX21 656 + 657 +Word number of module is 1 658 + 659 +Slot number is 2 660 + 661 +Remote number and unit number are 0 662 +))) 663 +|WY|0 – FFFF (Hex)|WY H1H2H3H4 664 +|WR|0 – FFFF (Hex)|WR HHHH| 665 +|WL|0 - 73FF (Hex)|WL HHHH| 666 +|TC|0 - 2559|TC DDDD| 667 + 668 +**Communication settings in HMI** 669 + 670 +Enable HMI Ethernet in [Project Settings]; 671 + 672 +(% style="text-align:center" %) 673 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 674 + 675 +Set PLC IP in [Device IP] settings; 676 + 677 +(% style="text-align:center" %) 678 +[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 679 + 680 +**PLC Configuration** 681 + 682 +Connect with PLC, select[Online mode]; 683 + 684 +(% style="text-align:center" %) 685 +[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 686 + 687 +Set IP address, it is the same LAN parameters with HMI; 688 + 689 +(% style="text-align:center" %) 690 +[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 691 + 692 +3) Save PLC communication parameter, and restart PLC 693 + 694 +**PLC Monitor Mode** 695 + 696 +Connect with PLC and choose to “online” mode 697 + 698 +(% style="text-align:center" %) 699 +[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 700 + 701 +Open I/O monitor sheet1 702 + 703 +(% style="text-align:center" %) 704 +[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 705 + 706 +During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 707 + 708 +(% style="text-align:center" %) 709 +[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 710 + 711 +Enter the register address, click OK to view the value of the register. 712 + 713 +(% style="text-align:center" %) 714 +[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 715 + 716 +(% style="text-align:center" %) 717 +[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 718 + 719 +**✎Note:** 720 + 721 +* Both word registers and bit registers support even continuous read/write functions; 722 +* The range of registers is based on the specific PLC type; 723 + 724 +**Cable Wiring** 725 + 726 +(% style="text-align:center" %) 727 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 728 + 729 += **IEC60870-5 104 Client** = 730 + 731 +**HMI Setting** 732 + 733 +(% class="table-bordered" %) 734 +|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 735 +|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 736 +|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 737 +|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 738 + 739 +**Address List** 740 + 741 +(% class="table-bordered" %) 742 +|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 743 +|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 744 +|(% style="width:461px" %)SCNA|0~~16777215.7 745 +|(% style="width:461px" %)DPTB|0~~16777215.7 746 +|(% style="width:461px" %)DCNA|0~~16777215.7 747 +|(% style="width:461px" %)METF|0~~16777215.7 748 +|(% style="width:461px" %)SENC|0~~16777215.7 749 +|(% style="width:461px" %)SENA|0~~16777215.7 750 +|(% style="width:461px" %)MENA|0~~16777215.7 751 +|(% style="width:461px" %)METD|0~~16777215.7 752 +|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 753 +|(% style="width:461px" %)SCNA|0~~16777215 754 +|(% style="width:461px" %)DPTB|0~~16777215 755 +|(% style="width:461px" %)DCNA|0~~16777215 756 +|(% style="width:461px" %)SENA|0~~16777215 757 +|(% style="width:461px" %)MENA|0~~16777215 758 +|(% style="width:461px" %)METD|0~~16777215 759 +|(% style="width:461px" %)INRO|0~~16777215 760 +|(% style="width:461px" %)TIMESYN|0~~16777215 761 +|(% style="width:461px" %)TIMEZ|0~~16777215 762 +|(% style="width:461px" %)NTP|0~~16777215 763 +|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 764 +|(% style="width:461px" %)SENC|0~~16777215 765 + 766 +**Address Configuration** 767 + 768 +The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 769 + 770 +(% style="text-align:center" %) 771 +[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 772 + 773 +(% style="text-align:center" %) 774 +[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 775 + 776 +Extended tag name 777 + 778 +Address range for the extended tag. 779 + 780 +**Communication Settings** 781 + 782 +Enable HMI Ethernet in [Project Settings]; 783 + 784 +(% style="text-align:center" %) 785 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 786 + 787 +Set PLC IP in [Device IP] settings; 788 + 789 +(% style="text-align:center" %) 790 +[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 791 + 792 +**Cable Wiring** 793 + 794 +(% style="text-align:center" %) 795 +[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 796 + 797 += **LG XGK FEnet Ethernet** = 798 + 799 +Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 800 + 801 +**HMI Settings** 802 + 803 +(% class="table-bordered" %) 804 +|**Items**|**Settings**|**Note** 805 +|Protocol|LG XGK FEnet(Ethernet)| 806 +|Connection|Ethernet| 807 +|Port No.|2004| 808 + 809 +**Address List** 810 + 811 +(% class="table-bordered" %) 812 +|**Type**|**Register**|**Range**|**Format**|**Note** 813 +|(% rowspan="14" %)Word|P|0~~2047|P d| 814 +|M|0~~2047|M d| 815 +|K|0~~2047|K d| 816 +|F|0~~2047|F d| 817 +|T|0~~2047|T d| 818 +|C|0~~2047|C d| 819 +|Z|0~~127|Z d| 820 +|S|0~~127|S d| 821 +|L|0~~11263|L d| 822 +|N|0~~21503|N d| 823 +|D|0~~32767|D d| 824 +|R|0~~32767|R d| 825 +|ZR|0~~65535|ZR d| 826 +|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 827 + 828 +**✎Note:** 829 + 830 +* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 831 +* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 832 +* All bit registers are in the form of bits in word, and the range is the same as the word register; 833 + 834 +**Communication settings in HMI** 835 + 836 +Enable HMI Ethernet in [Project Settings]; 837 + 838 +(% style="text-align:center" %) 839 +[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 840 + 841 +Set PLC IP in [Device IP] settings; 842 + 843 +(% style="text-align:center" %) 844 +[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 845 + 846 +**Cable Wiring** 847 + 599 599 = **Mitsubishi** = 600 600 601 601 == **FX1S, 1N, 2N Series** == ... ... @@ -2369,6 +2369,8 @@ 2369 2369 2370 2370 **✎Note:** COM3 only available in PI8000/PI9000 series. 2371 2371 2621 += = 2622 + 2372 2372 = **Printer** = 2373 2373 2374 2374 == **TSPL label printer** == ... ... @@ -2599,252 +2599,3 @@ 2599 2599 * The protocol uploads the information acquired by the USB scanner to the HMI; 2600 2600 * The acquired information is displayed in string mode, so it is necessary to use [characters input/display] object; 2601 2601 * Recommended model: DELI 14880 barcode scanner; 2602 - 2603 -= **Hitachi EHV Series (Ethernet)** = 2604 - 2605 -Supported series: Hitachi EHV series 2606 - 2607 -**HMI Settings** 2608 - 2609 -(% class="table-bordered" %) 2610 -|**Items**|**Settings**|**Note** 2611 -|Protocol|Hitachi EHV series| 2612 -|Connection|Ethernet| 2613 -|Port No.|3004~~3007| 2614 - 2615 -**Address List** 2616 - 2617 -(% class="table-bordered" %) 2618 -|**Type**|**Register**|**Range**|**Format**|**Note** 2619 -|(% rowspan="6" %)Bit|T|0 - 2545|T DDDD| 2620 -|M|0 - 7FFF.f (Hex)|M HHHH.h| 2621 -|X|0 – FFFF.f (Hex)|X H1H2H3H4.h|(% rowspan="2" %)((( 2622 -H1H2H3H4 Module main number 2623 - 2624 -H1: Remote number 2625 - 2626 -H2: Unit number 2627 - 2628 -H3: Slot number 2629 - 2630 -H4: Word number of Module 2631 - 2632 -H Sub number of Module 2633 - 2634 -For example:X21.3 2635 - 2636 -Slot number 2 2637 - 2638 -Word number of module is 1 2639 - 2640 -Bit number of module is 3 2641 - 2642 -Remote number and unit number are 0 2643 -))) 2644 -|Y|0 – FFFF.f (Hex)|Y H1H2H3H4.h 2645 -|R|0 – FF.f (Hex)|R HH.h| 2646 -|L|0 - 73FF.f (Hex)|L HHHH.h| 2647 -|(% rowspan="6" %)Word|WM|0 - 7FFF (Hex)|WM HHHH| 2648 -|WX|0 – FFFF (Hex)|WX H1H2H3H4|(% rowspan="2" %)((( 2649 -H1H2H3H4 Module main number 2650 - 2651 -H1: Remote number 2652 - 2653 -H2: Unit number 2654 - 2655 -H3: Slot number 2656 - 2657 -H4: Word number of module 2658 - 2659 -For example:WX21 2660 - 2661 -Word number of module is 1 2662 - 2663 -Slot number is 2 2664 - 2665 -Remote number and unit number are 0 2666 -))) 2667 -|WY|0 – FFFF (Hex)|WY H1H2H3H4 2668 -|WR|0 – FFFF (Hex)|WR HHHH| 2669 -|WL|0 - 73FF (Hex)|WL HHHH| 2670 -|TC|0 - 2559|TC DDDD| 2671 - 2672 -**Communication settings in HMI** 2673 - 2674 -Enable HMI Ethernet in [Project Settings]; 2675 - 2676 -(% style="text-align:center" %) 2677 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2678 - 2679 -Set PLC IP in [Device IP] settings; 2680 - 2681 -(% style="text-align:center" %) 2682 -[[image:12.PLC Protocol_html_d825387f5bde6cdd.png||data-xwiki-image-style-alignment="center" height="190" width="554" class="img-thumbnail"]] 2683 - 2684 -**PLC Configuration** 2685 - 2686 -Connect with PLC, select[Online mode]; 2687 - 2688 -(% style="text-align:center" %) 2689 -[[image:12.PLC Protocol_html_8430dda44e5c199c.png||data-xwiki-image-style-alignment="center" height="420" width="600" class="img-thumbnail"]] 2690 - 2691 -Set IP address, it is the same LAN parameters with HMI; 2692 - 2693 -(% style="text-align:center" %) 2694 -[[image:12.PLC Protocol_html_1d8a634f64e25fc3.png||data-xwiki-image-style-alignment="center" height="252" width="347" class="img-thumbnail"]] 2695 - 2696 -3) Save PLC communication parameter, and restart PLC 2697 - 2698 -**PLC Monitor Mode** 2699 - 2700 -Connect with PLC and choose to “online” mode 2701 - 2702 -(% style="text-align:center" %) 2703 -[[image:12.PLC Protocol_html_cdac598e770e3b67.png||data-xwiki-image-style-alignment="center" height="193" width="553" class="img-thumbnail"]] 2704 - 2705 -Open I/O monitor sheet1 2706 - 2707 -(% style="text-align:center" %) 2708 -[[image:12.PLC Protocol_html_68eb3518e5f80892.png||data-xwiki-image-style-alignment="center" height="369" width="559" class="img-thumbnail"]] 2709 - 2710 -During monitoring bit address,1 pts should be selected; during monitoring word address, 16 pts should be selected 2711 - 2712 -(% style="text-align:center" %) 2713 -[[image:12.PLC Protocol_html_774652d8daf548d4.png||data-xwiki-image-style-alignment="center" height="118" width="102" class="img-thumbnail"]] 2714 - 2715 -Enter the register address, click OK to view the value of the register. 2716 - 2717 -(% style="text-align:center" %) 2718 -[[image:12.PLC Protocol_html_bba169c300c92051.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2719 - 2720 -(% style="text-align:center" %) 2721 -[[image:12.PLC Protocol_html_d3b23bb9e81921a3.png||data-xwiki-image-style-alignment="center" height="404" width="600" class="img-thumbnail"]] 2722 - 2723 -**✎Note:** 2724 - 2725 -* Both word registers and bit registers support even continuous read/write functions; 2726 -* The range of registers is based on the specific PLC type; 2727 - 2728 -**Cable Wiring** 2729 - 2730 -(% style="text-align:center" %) 2731 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2732 - 2733 -= **IEC60870-5 104 Client** = 2734 - 2735 -**HMI Setting** 2736 - 2737 -(% class="table-bordered" %) 2738 -|**Items**|(% style="width:725px" %)**Settings**|(% style="width:309px" %)**Note** 2739 -|Protocol|(% style="width:725px" %)IEC60870-5 104 Client|(% style="width:309px" %) 2740 -|Connection|(% style="width:725px" %)Ethernet|(% style="width:309px" %) 2741 -|Port No.|(% style="width:725px" %)2404|(% style="width:309px" %) 2742 - 2743 -**Address List** 2744 - 2745 -(% class="table-bordered" %) 2746 -|(% style="width:460px" %)**Type**|(% style="width:461px" %)**Register**|**Range** 2747 -|(% rowspan="9" style="width:460px" %)Bit|(% style="width:461px" %)SPTB|0~~16777215.7 2748 -|(% style="width:461px" %)SCNA|0~~16777215.7 2749 -|(% style="width:461px" %)DPTB|0~~16777215.7 2750 -|(% style="width:461px" %)DCNA|0~~16777215.7 2751 -|(% style="width:461px" %)METF|0~~16777215.7 2752 -|(% style="width:461px" %)SENC|0~~16777215.7 2753 -|(% style="width:461px" %)SENA|0~~16777215.7 2754 -|(% style="width:461px" %)MENA|0~~16777215.7 2755 -|(% style="width:461px" %)METD|0~~16777215.7 2756 -|(% rowspan="11" style="width:460px" %)Word|(% style="width:461px" %)SPTB|0~~16777215 2757 -|(% style="width:461px" %)SCNA|0~~16777215 2758 -|(% style="width:461px" %)DPTB|0~~16777215 2759 -|(% style="width:461px" %)DCNA|0~~16777215 2760 -|(% style="width:461px" %)SENA|0~~16777215 2761 -|(% style="width:461px" %)MENA|0~~16777215 2762 -|(% style="width:461px" %)METD|0~~16777215 2763 -|(% style="width:461px" %)INRO|0~~16777215 2764 -|(% style="width:461px" %)TIMESYN|0~~16777215 2765 -|(% style="width:461px" %)TIMEZ|0~~16777215 2766 -|(% style="width:461px" %)NTP|0~~16777215 2767 -|(% rowspan="2" style="width:460px" %)Double word|(% style="width:461px" %)METF|0~~16777215 2768 -|(% style="width:461px" %)SENC|0~~16777215 2769 - 2770 -**Address Configuration** 2771 - 2772 -The address registers of the IEC60870-5-104 protocol are SPTB, SCNA, DPTB, DCNA, METF, and SENC. The protocol needs to be added with an extension tag "ASDU", which could only be added in the [Address Identification Library], other places are not editable, that is, the read address in the object or script is not editable. 2773 - 2774 -(% style="text-align:center" %) 2775 -[[image:12.PLC Protocol_html_ba78d143bf457ead.png||data-xwiki-image-style-alignment="center" height="369" width="600" class="img-thumbnail"]] 2776 - 2777 -(% style="text-align:center" %) 2778 -[[image:12.PLC Protocol_html_23533fd5bb81f4ab.png||data-xwiki-image-style-alignment="center" height="389" width="600" class="img-thumbnail"]] 2779 - 2780 -Extended tag name 2781 - 2782 -Address range for the extended tag. 2783 - 2784 -**Communication Settings** 2785 - 2786 -Enable HMI Ethernet in [Project Settings]; 2787 - 2788 -(% style="text-align:center" %) 2789 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2790 - 2791 -Set PLC IP in [Device IP] settings; 2792 - 2793 -(% style="text-align:center" %) 2794 -[[image:12.PLC Protocol_html_f848736ec68b125.png||data-xwiki-image-style-alignment="center" height="191" width="554" class="img-thumbnail"]] 2795 - 2796 -**Cable Wiring** 2797 - 2798 -(% style="text-align:center" %) 2799 -[[image:12.PLC Protocol_html_2297240b57346b2a.png||data-xwiki-image-style-alignment="center" height="170" width="401" class="img-thumbnail"]] 2800 - 2801 -= **LG XGK FEnet Ethernet** = 2802 - 2803 -Supported Series: LS XGT series XGK CPU with XGL-EFMT Ethernet module 2804 - 2805 -**HMI Settings** 2806 - 2807 -(% class="table-bordered" %) 2808 -|**Items**|**Settings**|**Note** 2809 -|Protocol|LG XGK FEnet(Ethernet)| 2810 -|Connection|Ethernet| 2811 -|Port No.|2004| 2812 - 2813 -**Address List** 2814 - 2815 -(% class="table-bordered" %) 2816 -|**Type**|**Register**|**Range**|**Format**|**Note** 2817 -|(% rowspan="14" %)Word|P|0~~2047|P d| 2818 -|M|0~~2047|M d| 2819 -|K|0~~2047|K d| 2820 -|F|0~~2047|F d| 2821 -|T|0~~2047|T d| 2822 -|C|0~~2047|C d| 2823 -|Z|0~~127|Z d| 2824 -|S|0~~127|S d| 2825 -|L|0~~11263|L d| 2826 -|N|0~~21503|N d| 2827 -|D|0~~32767|D d| 2828 -|R|0~~32767|R d| 2829 -|ZR|0~~65535|ZR d| 2830 -|UxDD|0~~6331|UxDD nndd|nn: 0~~63, dd: 0~~31 2831 - 2832 -**✎Note:** 2833 - 2834 -* In addition to the "UxDD" register, the others correspond to the PLC register one by one. UxDD corresponds to U in the PLC; 2835 -* The [UxDD] register, defined in the PLC is Ux.dd, x represents the block, and dd represents 0-31 of each block. There are 64 blocks in the PLC; 2836 -* All bit registers are in the form of bits in word, and the range is the same as the word register; 2837 - 2838 -**Communication settings in HMI** 2839 - 2840 -Enable HMI Ethernet in [Project Settings]; 2841 - 2842 -(% style="text-align:center" %) 2843 -[[image:12.PLC Protocol_html_43b671f18153910d.png||data-xwiki-image-style-alignment="center" height="107" width="405" class="img-thumbnail"]] 2844 - 2845 -Set PLC IP in [Device IP] settings; 2846 - 2847 -(% style="text-align:center" %) 2848 -[[image:12.PLC Protocol_html_a2a19b5003ad4090.png||data-xwiki-image-style-alignment="center" height="189" width="554" class="img-thumbnail"]] 2849 - 2850 -**Cable Wiring**