Changes for page LX3V-4AD
Last modified by Devin Chen on 2024/11/27 15:04
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -10,102 +10,23 @@ 10 10 (% style="text-align:center" %) 11 11 [[image:LX3V-4AD_html_5159808b9e4fa86a.png||height="391" width="1000" class="img-thumbnail"]] 12 12 13 -1. ((( 14 -Extension cable and connector 15 -))) 16 -1. ((( 17 -COM LED: Light when communicating Error LED: Channel calibration indicators 18 -))) 19 -1. ((( 20 -Power LED: Light when connect to 24V 21 -))) 22 -1. ((( 23 -State LED: Light when normal condition 24 -))) 25 -1. ((( 26 -Link LED: Light when communicate with PLC 27 -))) 28 -1. ((( 29 -Module name 30 -))) 31 -1. ((( 32 -Extension module interface 33 -))) 34 -1. ((( 35 -DIN rail mounting slot 36 -))) 37 -1. ((( 38 -DIN rail hook 39 -))) 40 -1. ((( 41 -Holes for direct installation: 2 places (Φ4.5) 42 -))) 13 +1. Extension cable and connector 14 +1. COM LED: Light when communicating 15 +1. Power LED: Light when connect to 24V 16 +1. State LED: Light when normal condition 17 +1. Module name 18 +1. Analog signal output terminal 19 +1. Extension module interface 20 +1. DIN rail mounting slot 21 +1. DIN rail hook 43 43 44 44 ((( 45 -(% style="margin-left:auto; margin-right:auto" %) 46 -|=**Name**|=**Description**|=**Light status**|=**Event status** 47 -|(% rowspan="2" %)((( 48 -COM LED 49 - 50 - 51 -)))|(% rowspan="2" %)((( 52 -Communication indicator for communication board and acquisition board 53 - 54 - 55 -)))|Flashing|Data interacting 56 -|Off|Data interaction error/stop/failure 57 -|(% rowspan="2" %)((( 58 -ERR LED 59 - 60 - 61 -)))|(% rowspan="2" %)((( 62 -Factory calibration LED 63 - 64 - 65 -)))|Off|Factory calibrated 66 -|Lighting|Factory uncalibrated 67 -|(% rowspan="2" %)((( 68 -24V LED 69 - 70 - 71 -)))|(% rowspan="2" %)((( 72 -Power indicator 73 - 74 - 75 -)))|Off|24V power is abnormal. 76 -|Lighting|24V power is normal. 77 -|(% rowspan="3" %)((( 78 -LINK LED 79 - 80 - 81 -)))|(% rowspan="3" %)((( 82 -Communication indicator for PLC and expansion module 83 - 84 - 85 -)))|Flashing|Data interacting 86 -|Off|Data interaction error/stop/failure 87 -|Lighting|Software running abnormal or hardware failure 88 -|(% rowspan="3" %)((( 89 -AD LED 90 - 91 - 92 -)))|(% rowspan="3" %)((( 93 -4 channel indicators 94 - 95 - 96 -)))|Flashing|Input voltage or current range exceed limit or channel unconnected 97 -|Off|Channel closed 98 -|Lighting|Input analog is in the normal range 99 - 100 -(% style="text-align:center" %) 101 -[[image:LX3V-4AD_html_5bc4b53029347d0f.png||height="309" width="618" class="img-thumbnail"]] 102 - 103 - 104 104 Please use crimp terminals as indicated on the graph. 105 105 106 106 The tightening torque should be applied 5 to 8 Kg.cm. 107 107 108 -= = 28 +(% style="text-align:center" %) 29 +[[image:LX3V-4AD_html_5bc4b53029347d0f.png||height="195" width="400" class="img-thumbnail"]] 109 109 110 110 = **3 Terminal layouts** = 111 111 ... ... @@ -384,6 +384,9 @@ 384 384 1. The operational status of the LX3V-4AD is read from BFM #29 and output as bit devices at the LX3V main unit. If there are no errors in the operation of the LX3V-4AD, then the averaged data BFM’s are read. 385 385 1. In the case of this example BFM #5 and #6 are read into the LX3V main unit and stored at D0 and D1. These devices contain the averaged data for CH1 and CH2 respectively. 386 386 308 + 309 + 310 + 387 387 **Using gain and offset in a program** 388 388 389 389 The gain and offset of the LX3V-4AD can be adjusted using push-button switches on the input terminal of the PC. It can also be adjusted using software settings sent from the PC. ... ... @@ -415,7 +415,7 @@ 415 415 416 416 **High-speed conversion by changing A/D conversion time in a program** 417 417 418 -[[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]][[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]] [[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]][[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]][[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]]**[[image:6.3-图片1.png]]**342 +[[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]][[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]]**[[image:6.3-图片1.png]]** 419 419 ))) 420 420 421 421 Writing K10 to BFM#15 and set conversion time of all channels as 3ms.