... ... @@ -10,102 +10,23 @@
10 10  (% style="text-align:center" %)
11 11  [[image:LX3V-4AD_html_5159808b9e4fa86a.png||height="391" width="1000" class="img-thumbnail"]]
12 12  
13 -1. (((
14 -Extension cable and connector
15 -)))
16 -1. (((
17 -COM LED: Light when communicating Error LED: Channel calibration indicators
18 -)))
19 -1. (((
20 -Power LED: Light when connect to 24V
21 -)))
22 -1. (((
23 -State LED: Light when normal condition
24 -)))
25 -1. (((
26 -Link LED: Light when communicate with PLC
27 -)))
28 -1. (((
29 -Module name
30 -)))
31 -1. (((
32 -Extension module interface
33 -)))
34 -1. (((
35 -DIN rail mounting slot
36 -)))
37 -1. (((
38 -DIN rail hook
39 -)))
40 -1. (((
41 -Holes for direct installation: 2 places (Φ4.5)
42 -)))
13 +1. Extension cable and connector
14 +1. COM LED: Light when communicating
15 +1. Power LED: Light when connect to 24V
16 +1. State LED: Light when normal condition
17 +1. Module name
18 +1. Analog signal output terminal
19 +1. Extension module interface
20 +1. DIN rail mounting slot
21 +1. DIN rail hook
43 43  
44 44  (((
45 -(% style="margin-left:auto; margin-right:auto" %)
46 -|=**Name**|=**Description**|=**Light status**|=**Event status**
47 -|(% rowspan="2" %)(((
48 -COM LED
49 -
50 -
51 -)))|(% rowspan="2" %)(((
52 -Communication indicator for communication board and acquisition board
53 -
54 -
55 -)))|Flashing|Data interacting
56 -|Off|Data interaction error/stop/failure
57 -|(% rowspan="2" %)(((
58 -ERR LED
59 -
60 -
61 -)))|(% rowspan="2" %)(((
62 -Factory calibration LED
63 -
64 -
65 -)))|Off|Factory calibrated
66 -|Lighting|Factory uncalibrated
67 -|(% rowspan="2" %)(((
68 -24V LED
69 -
70 -
71 -)))|(% rowspan="2" %)(((
72 -Power indicator
73 -
74 -
75 -)))|Off|24V power is abnormal.
76 -|Lighting|24V power is normal.
77 -|(% rowspan="3" %)(((
78 -LINK LED
79 -
80 -
81 -)))|(% rowspan="3" %)(((
82 -Communication indicator for PLC and expansion module
83 -
84 -
85 -)))|Flashing|Data interacting
86 -|Off|Data interaction error/stop/failure
87 -|Lighting|Software running abnormal or hardware failure
88 -|(% rowspan="3" %)(((
89 -AD LED
90 -
91 -
92 -)))|(% rowspan="3" %)(((
93 -4 channel indicators
94 -
95 -
96 -)))|Flashing|Input voltage or current range exceed limit or channel unconnected
97 -|Off|Channel closed
98 -|Lighting|Input analog is in the normal range
99 -
100 -(% style="text-align:center" %)
101 -[[image:LX3V-4AD_html_5bc4b53029347d0f.png||height="309" width="618" class="img-thumbnail"]]
102 -
103 -
104 104  Please use crimp terminals as indicated on the graph.
105 105  
106 106  The tightening torque should be applied 5 to 8 Kg.cm.
107 107  
108 -= =
28 +(% style="text-align:center" %)
29 +[[image:LX3V-4AD_html_5bc4b53029347d0f.png||height="195" width="400" class="img-thumbnail"]]
109 109  
110 110  = **3 Terminal layouts** =
111 111  
... ... @@ -384,6 +384,9 @@
384 384  1. The operational status of the LX3V-4AD is read from BFM #29 and output as bit devices at the LX3V main unit. If there are no errors in the operation of the LX3V-4AD, then the averaged data BFM’s are read.
385 385  1. In the case of this example BFM #5 and #6 are read into the LX3V main unit and stored at D0 and D1. These devices contain the averaged data for CH1 and CH2 respectively.
386 386  
308 +
309 +
310 +
387 387  **Using gain and offset in a program**
388 388  
389 389  The gain and offset of the LX3V-4AD can be adjusted using push-button switches on the input terminal of the PC. It can also be adjusted using software settings sent from the PC.
... ... @@ -415,7 +415,7 @@
415 415  
416 416  **High-speed conversion by changing A/D conversion time in a program**
417 417  
418 -[[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]][[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]][[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]][[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]][[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]]**[[image:6.3-图片1.png]]**
342 +[[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]][[image:/bin/download/Expansions/1%20Module/Analog/LX3V-4AD/WebHome/6.3-%E5%9B%BE%E7%89%871.png?rev=1.1||alt="6.3-图片1.png"]]**[[image:6.3-图片1.png]]**
419 419  )))
420 420  
421 421  Writing K10 to BFM#15 and set conversion time of all channels as 3ms.