From version 2.2
edited by Leo Wei
on 2022/06/08 14:42
on 2022/06/08 14:42
Change comment:
Update document after refactoring.
To version 5.1
edited by Devin Chen
on 2023/10/18 11:43
on 2023/10/18 11:43
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.DevinChen - Content
-
... ... @@ -8,34 +8,26 @@ 8 8 = **2 External dimensions and parts** = 9 9 10 10 (% style="text-align:center" %) 11 -[[image:LX3V-4DA_html_305fb145f01df02f.png|| class="img-thumbnail" height="337" width="1000"]]11 +[[image:LX3V-4DA_html_305fb145f01df02f.png||height="337" width="1000" class="img-thumbnail"]] 12 12 13 -① Extension cable and connector 13 +1. Extension cable and connector 14 +1. Com LED: Light when communicating 15 +1. Power LED: Light when getting power 16 +1. State LED: Light when normal condition 17 +1. Module name 18 +1. Analog signal output terminal 19 +1. Extension module interface 20 +1. DIN rail mounting slot 21 +1. DIN rail hook 22 +1. Mounting holes (φ4.5) 14 14 15 -② Com LED: Light when communicating 16 - 17 -③ Power LED: Light when getting power 18 - 19 -④ State LED: Light when normal condition 20 - 21 -⑤ Module name 22 - 23 -⑥ Analog signal output terminal 24 - 25 -⑦ Extension module interface 26 - 27 -⑧ DIN rail mounting slot 28 - 29 -⑨ DIN rail hook 30 - 31 -⑩ Mounting holes (φ4.5) 32 - 33 33 ((( 34 -* Be sure to use the crimp-style terminals that satisfy the dimensional requirements shows in the left figure. 35 -* Apply 0.5 to 0.8 N.m (5 to 8 kgf.cm) torque to tighten the terminals to prevent abnormal operation. 25 +Be sure to use the crimp-style terminals that satisfy the dimensional requirements shows in the left figure. 36 36 27 +Apply 0.5 to 0.8 N.m (5 to 8 kgf.cm) torque to tighten the terminals to prevent abnormal operation. 28 + 37 37 (% style="text-align:center" %) 38 -[[image:LX3V-4DA_html_567be68423413d26.png|| class="img-thumbnail" height="199" width="300"]]30 +[[image:LX3V-4DA_html_567be68423413d26.png||height="199" width="300" class="img-thumbnail"]] 39 39 ))) 40 40 41 41 = **3 Installation and wiring** = ... ... @@ -43,42 +43,36 @@ 43 43 Various special blocks controlled by the FROM/TO commands, such as the analog input blocks high-speed counter blocks, etc. can be connected to the LX3V programmable controller (MPU), or connected to the right side of the other extension blocks or units. Up to 16 special blocks can be connected to a single MPU in the numeric order of No. 0 to No.15. 44 44 45 45 (% style="text-align:center" %) 46 -[[image:LX3V-4DA_html_272dd0c915b463ef.png|| class="img-thumbnail" height="344" width="1100"]]38 +[[image:LX3V-4DA_html_272dd0c915b463ef.png||height="344" width="1100" class="img-thumbnail"]] 47 47 48 48 **WIRING: **The terminal layout shown below may differ from the actual layout. For the correct terminal layout, refer to section 2 External Dimensions and Parts. 49 49 50 50 (% style="text-align:center" %) 51 -[[image:LX3V-4DA_html_6f615e1cb3ad1139.png|| class="img-thumbnail" height="212" width="800"]]43 +[[image:LX3V-4DA_html_6f615e1cb3ad1139.png||height="212" width="800" class="img-thumbnail"]] 52 52 53 -*1: Use a twisted pair shielded cable for the analog output. This cable should be wired away from power lines or any other lines which could induce noise. 45 +* *1: Use a twisted pair shielded cable for the analog output. This cable should be wired away from power lines or any other lines which could induce noise. 46 +* *2: Apply 1-point grounding at the load side of the output cable (class 3 grounding: 100Ω or less). 47 +* *3: If electrical noise or a voltage ripple exists at the output, connect a smoothing capacitor of 0.1 to 0.47uF, 25V. 48 +* *4: Connect the [[image:LX3V-4DA_html_521762f8994ba428.png]] terminal on the LX3V-4DA with the [[image:LX3V-4DA_html_521762f8994ba428.png]] terminal on the MPU of the programmable controller. 49 +* *5: Shorting the voltage output terminal or connecting the current output load to the voltage output terminal may damage the LX3V-4DA. 50 +* *6: The 24V DC service power of the programmable controller can also be used. 51 +* *7: Don’t connect any unit to the unused terminal [[image:LX3V-4DA_html_9ea03e9f7e6e8562.png]] 54 54 55 -*2: Apply 1-point grounding at the load side of the output cable (class 3 grounding: 100Ω or less). 56 - 57 -*3: If electrical noise or a voltage ripple exists at the output, connect a smoothing capacitor of 0.1 to 0.47uF, 25V. 58 - 59 -*4: Connect the [[image:LX3V-4DA_html_521762f8994ba428.png]] terminal on the LX3V-4DA with the [[image:LX3V-4DA_html_521762f8994ba428.png]] terminal on the MPU of the programmable controller. 60 - 61 -*5: Shorting the voltage output terminal or connecting the current output load to the voltage output terminal may damage the LX3V-4DA. 62 - 63 -*6: The 24V DC service power of the programmable controller can also be used. 64 - 65 -*7: Don’t connect any unit to the unused terminal [[image:LX3V-4DA_html_9ea03e9f7e6e8562.png]] 66 - 67 67 = **4 Allocation of buffer memories (BFM)** = 68 68 69 69 (% border="1" %) 70 -|**BFM**|(% colspan="3" %)**Description** 71 -|#0(E)|(% colspan="3" %)Output mode select. Factory setting H0000 72 -|#1|Output data Channel CH1|(% colspan="2" rowspan="4" %)Channel output value, default: 0 73 -|#2|Output data Channel CH2 74 -|#3|Output data Channel CH3 75 -|#4|Output data Channel CH4 76 -|#5(E)|(% colspan="3" %)Holding mode 77 -|#6|(% colspan="3" %)Reserved 78 -|#7|(% colspan="3" %)Reserved 79 -|#8(E)|(% colspan="3" %)Offset/gain setting command CH1,CH2 default :H0000 80 -|#9(E)|(% colspan="3" %)Offset/gain setting command CH3,CH4 default :H0000 81 -|#10|(% colspan="2" %)Offset data CH1*1|(% rowspan="8" %)((( 56 +|=(% scope="row" %)**BFM**|=(% colspan="3" %)**Description** 57 +|=#0(E)|(% colspan="3" %)Output mode select. Factory setting H0000 58 +|=#1|Output data Channel CH1|(% colspan="2" rowspan="4" %)Channel output value, default: 0 59 +|=#2|Output data Channel CH2 60 +|=#3|Output data Channel CH3 61 +|=#4|Output data Channel CH4 62 +|=#5(E)|(% colspan="3" %)Holding mode 63 +|=#6|(% colspan="3" %)Reserved 64 +|=#7|(% colspan="3" %)Reserved 65 +|=#8(E)|(% colspan="3" %)Offset/gain setting command CH1,CH2 default :H0000 66 +|=#9(E)|(% colspan="3" %)Offset/gain setting command CH3,CH4 default :H0000 67 +|=#10|(% colspan="2" %)Offset data CH1*1|(% rowspan="8" %)((( 82 82 Unit: mV or μA 83 83 84 84 Default offset value:0 ... ... @@ -87,123 +87,112 @@ 87 87 88 88 Output mode 0 89 89 ))) 90 -|#11|(% colspan="2" %)Gain data CH1*2 91 -|#12|(% colspan="2" %)Offset data CH2*1 92 -|#13|(% colspan="2" %)Gain data CH2*2 93 -|#14|(% colspan="2" %)Offset data CH3*1 94 -|#15|(% colspan="2" %)Gain data CH3*2 95 -|#16|(% colspan="2" %)Offset data CH4*1 96 -|#17|(% colspan="2" %)Gain data CH4*2 97 -|#18,#19|(% colspan="3" %)Reserved 98 -|#20(E)|(% colspan="3" %)Initialize, default: 0 99 -|#21E|(% colspan="3" %)I/O characteristics adjustment inhibit (Initial value 1) 100 -|#22-#28|(% colspan="3" %)Reserved 101 -|#29|(% colspan="3" %)Error states 102 -|#30|(% colspan="3" %)K3020 identification code 103 -|#31|(% colspan="3" %)Software version 76 +|=#11|(% colspan="2" %)Gain data CH1*2 77 +|=#12|(% colspan="2" %)Offset data CH2*1 78 +|=#13|(% colspan="2" %)Gain data CH2*2 79 +|=#14|(% colspan="2" %)Offset data CH3*1 80 +|=#15|(% colspan="2" %)Gain data CH3*2 81 +|=#16|(% colspan="2" %)Offset data CH4*1 82 +|=#17|(% colspan="2" %)Gain data CH4*2 83 +|=#18,#19|(% colspan="3" %)Reserved 84 +|=#20(E)|(% colspan="3" %)Initialize, default: 0 85 +|=#21E|(% colspan="3" %)I/O characteristics adjustment inhibit (Initial value 1) 86 +|=#22-#28|(% colspan="3" %)Reserved 87 +|=#29|(% colspan="3" %)Error states 88 +|=#30|(% colspan="3" %)K3020 identification code 89 +|=#31|(% colspan="3" %)Software version 104 104 105 105 * **Channel Select** 106 106 107 107 The value of BFM #0 switches the analog output between voltage and current on each channel. It takes the form of a 4 digit hexadecimal number. The first digit will be the command for channel1 (CH1), and the second digit for channel 2 (CH2) etc. The numeric values of these four digits respectively represent the following items: 108 108 109 -O=0: Sets the voltage output mode (-10V to 10V); 95 +* O=0: Sets the voltage output mode (-10V to 10V); 96 +* O=1: Sets the current output mode (+4mA to +20mA); 97 +* O=2: Sets the current output mode (0mA to 20mA); 98 +* O=3: Channel OFF; 99 +* O=4: Sets the voltage output mode (-10V to 10V); 100 +* O=5: Sets the current output mode (+4mA to +20mA); 101 +* O=6: Sets the current output mode (0mA to 20mA); 110 110 111 -O=1: Sets the current output mode (+4mA to +20mA); 112 - 113 -O=2: Sets the current output mode (0mA to 20mA); 114 - 115 -O=3: Channel OFF; 116 - 117 -O=4: Sets the voltage output mode (-10V to 10V); 118 - 119 -O=5: Sets the current output mode (+4mA to +20mA); 120 - 121 -O=6: Sets the current output mode (0mA to 20mA); 122 - 123 123 **Example: H3310** 124 124 125 -CH1: voltage range (-10V to 10V); 105 +* CH1: voltage range (-10V to 10V); 106 +* CH2: voltage range (+4mA to +20mA); 107 +* CH3CH4: Channel OFF; 126 126 127 -CH2: voltage range (+4mA to +20mA); 128 - 129 -CH3CH4: Channel OFF; 130 - 131 131 (% border="1" %) 132 -|**BFM#0**|**Analog mode**|**Digital mode**|**Resolution**|**Gain/Offset**|**Constant** 133 -|0|-10V ~~ 10V|-2000 ~~2000|5mV|0/5000|1000 134 -|1|4mA ~~ 20mA|0 ~~ 1000|16uA|4000/20000|1000 135 -|2|0 ~~ 20mA|0 ~~ 1000|20uA|0/20000|1000 136 -|3|Disable|~-~-|~-~-|~-~-|~-~- 137 -|4|-10V ~~ 10V|-10000 ~~ 10000|1mV|0/5000|5000 138 -|5|4mA ~~ 20mA|0 ~~ 2000|8uA|4000/20000|2000 139 -|6|0 ~~ 20mA|0 ~~ 2000|10uA|0/20000|2000 110 +|=(% scope="row" %)**BFM#0**|=**Analog mode**|=**Digital mode**|=**Resolution**|=**Gain/Offset**|=**Constant** 111 +|=0|-10V ~~ 10V|-2000 ~~2000|5mV|0/5000|1000 112 +|=1|4mA ~~ 20mA|0 ~~ 1000|16uA|4000/20000|1000 113 +|=2|0 ~~ 20mA|0 ~~ 1000|20uA|0/20000|1000 114 +|=3|Disable|~-~-|~-~-|~-~-|~-~- 115 +|=4|-10V ~~ 10V|-10000 ~~ 10000|1mV|0/5000|5000 116 +|=5|4mA ~~ 20mA|0 ~~ 2000|8uA|4000/20000|2000 117 +|=6|0 ~~ 20mA|0 ~~ 2000|10uA|0/20000|2000 140 140 141 -* *[BFM #5]**119 +**[BFM #5]** 142 142 143 143 Data holding mode: While the programmable controller is in the STOP mode, the last output value in the RUN mode will be held. To reset the value to the offset value, write the hexadecimal value in BFM #5 as follows: 144 144 145 145 ((( 146 -O=0: Holds the output 124 +* O=0: Holds the output 125 +* O=1: Reset to the offset value 147 147 148 -O=1: Reset to the offset value 149 - 150 150 (% style="text-align:center" %) 151 -[[image:LX3V-4DA_html_1226aff1aed554b0.png|| class="img-thumbnail" height="75" width="200"]]128 +[[image:LX3V-4DA_html_1226aff1aed554b0.png||height="75" width="200" class="img-thumbnail"]] 152 152 ))) 153 153 154 154 **Example: H0011** 155 155 156 -CH1 and CH2=offset value; 133 +* CH1 and CH2=offset value; 134 +* CH3 and CH4=output holding; 157 157 158 - CH3andCH4=output holding;136 +**[BFM #8 and #9]** 159 159 160 -* **[BFM #8 and #9]** 161 - 162 162 Offset/gain setting command: Changes offset and gain values of channels CH1 through CH4 by writing 1 to the corresponding Hex digits of BFM #8 or #9. The current values will be valid until this command is output. 163 163 164 164 ((( 165 -O=0: No change done; 141 +* O=0: No change done; 142 +* O=1: Change data value 166 166 167 -O=1: Change data value 168 - 169 169 (% style="text-align:center" %) 170 -[[image:LX3V-4DA_html_7af7e1524e66e172.png|| class="img-thumbnail" height="97" width="400"]]145 +[[image:LX3V-4DA_html_7af7e1524e66e172.png||height="97" width="400" class="img-thumbnail"]] 171 171 ))) 172 172 173 -* *[BFM#10~~#17]**148 +**Formula for Gain/Offset: Analog output=Digital input*(Gain-Offset)/Constant+Offset** 174 174 150 +**[BFM #10 ~~ #17]** 151 + 175 175 Offset/gain data: The offset and gain values are changed by writing new data to BFM #10 through #17. The units of the data to be written are mV or µA. The data should be written and then BFM #8 and #9 set. Note that the data value will be rounded down to the nearest 5mV or 20µA. 176 176 177 -* *[BFM #20] Initialize**154 +**[BFM #20] Initialize** 178 178 179 179 When K1 is written in BFM #20, all values will be initialized to the factory-settings. (Note that the BFM #20 data will override the BFM #21 data.) This initialize function is convenient if users have an error in adjustment. 180 180 181 -* *[BFM #21] I/O characteristics adjustment inhibit**158 +**[BFM #21] I/O characteristics adjustment inhibit** 182 182 183 183 Setting BFM #21 to 2 inhibits the user from inadvertent adjustment of I/O characteristics. The adjustment inhibits function, once set, will be valid until the Permit command (BFM #21=1) is set. The initial value is 1 (Permit). The set value will be retained even after power-off. 184 184 185 -* *[BFM #29] Error status**162 +**[BFM #29] Error status** 186 186 187 187 When an error occurs, use the FROM command to read out the details of the error. 188 188 189 189 (% border="1" %) 190 -|**Bit**|**Name**|**Status when bit is set to “1" (turned on)**|((( 191 -**Status when bit is set to ”0"** 192 - 193 -**(turned off)** 167 +|=(% scope="row" style="width: 58px;" %)**Bit**|=(% style="width: 213px;" %)**Name**|=(% style="width: 463px;" %)**Status when bit is set to “1" (turned on)**|=((( 168 +**Status when bit is set to ”0" (turned off)** 194 194 ))) 195 -|b0|Error|Error if any of b1 through b4 is turned on|No error 196 -|b1|O/G error|Offset/gain data in EEPROM is abnormal or a data setting error occurs|Offset/Gain data normal 197 -|b2|Power supply error|24V DC power failure|Power supplied normally 198 -|b3|Hardware error|Defective D/A converter or other hardware|Non-detective hardware 199 -|b10|Range error|The digital input or analog output value is out of the specified range|The input or output value is in the specified range. 200 -|b12|G/O Adjustment prohibit status|BFM #21 is not set to “1".|((( 170 +|=(% style="width: 58px;" %)b0|(% style="width:213px" %)Error|(% style="width:463px" %)Error if any of b1 through b4 is turned on|No error 171 +|=(% style="width: 58px;" %)b1|(% style="width:213px" %)O/G error|(% style="width:463px" %)Offset/gain data in EEPROM is abnormal or a data setting error occurs|Offset/Gain data normal 172 +|=(% style="width: 58px;" %)b2|(% style="width:213px" %)Power supply error|(% style="width:463px" %)24V DC power failure|Power supplied normally 173 +|=(% style="width: 58px;" %)b3|(% style="width:213px" %)Hardware error|(% style="width:463px" %)Defective D/A converter or other hardware|Non-detective hardware 174 +|=(% style="width: 58px;" %)b10|(% style="width:213px" %)Range error|(% style="width:463px" %)The digital input or analog output value is out of the specified range|The input or output value is in the specified range. 175 +|=(% style="width: 58px;" %)b12|(% style="width:213px" %)G/O Adjustment prohibit status|(% style="width:463px" %)BFM #21 is not set to “1".|((( 201 201 Adjustable status 202 202 203 203 (BFM #21 = 1) 204 204 ))) 205 205 206 -* *[BFM #30]**181 +**[BFM #30]** 207 207 208 208 The identification code for a special block is read using the FROM command. The identification code for the LX3V-4DA unit is K3020.The MPU can use this facility in the program to identify the special block before commencing any data transfer from and to the special block. 209 209 ... ... @@ -218,14 +218,12 @@ 218 218 219 219 If the factory-set I/O characteristics are not changed and the status information is not used, user can operate the LX3V-4DA using the following simple program. For the FROM and TO commands, refer to the LX3V PLC Programming Manual. 220 220 221 -CH1 and CH2: Voltage output mode (-10V to +10V); 196 +1. CH1 and CH2: Voltage output mode (-10V to +10V); 197 +1. CH3: Current output mode (+4mA to +20mA); 198 +1. CH4: Current output mode (0mA to +20mA); 222 222 223 -CH3: Current output mode (+4mA to +20mA); 224 - 225 -CH4: Current output mode (0mA to +20mA); 226 - 227 227 (% style="text-align:center" %) 228 -[[image:LX3V-4DA_html_6cdc7105ddd85647.png|| class="img-thumbnail" height="196" width="400"]]201 +[[image:LX3V-4DA_html_6cdc7105ddd85647.png||height="196" width="400" class="img-thumbnail"]] 229 229 230 230 **✎Note: ** 231 231 ... ... @@ -237,16 +237,12 @@ 237 237 238 238 Write data in respective data registers while observing the following ranges: 239 239 240 -Data register D0 and D1: -2,000 to +2,000 Data register D2 and D3: 0 to +1,000 213 +* Data register D0 and D1: -2,000 to +2,000 Data register D2 and D3: 0 to +1,000 214 +* Data register D0→ BFM #1 (output to CH1) 215 +* Data register D1→ BFM #2 (output to CH2) 216 +* Data register D2→ BFM #3 (output to CH3) 217 +* Data register D3→ BFM #4 (output to CH4) 241 241 242 -Data register D0→ BFM #1 (output to CH1) 243 - 244 -Data register D1→ BFM #2 (output to CH2) 245 - 246 -Data register D2→ BFM #3 (output to CH3) 247 - 248 -Data register D3→ BFM #4 (output to CH4) 249 - 250 250 **Operation procedure** 251 251 252 252 1. Turn off the power of the MPU, and then connect the LX3V-4DA. After that, wire the I/O lines of the LX3V-4DA. ... ... @@ -282,7 +282,7 @@ 282 282 Output data abnormal 283 283 284 284 (% style="text-align:center" %) 285 -[[image:LX3V-4DA_html_7a75142ebdd9b334.png|| class="img-thumbnail" height="408" width="400"]]254 +[[image:LX3V-4DA_html_7a75142ebdd9b334.png||height="408" width="400" class="img-thumbnail"]] 286 286 ))) 287 287 288 288 = **6 Caution regarding operation** = ... ... @@ -293,7 +293,7 @@ 293 293 1. Check that there is no power overload on either the 5V or 24V power source, remember the loading on the LX3V MPU or a powered extension unit varies according to the number of extension blocks or special function blocks connected. 294 294 1. Put the main processing unit into RUN.((( 295 295 (% style="text-align:center" %) 296 -[[image:LX3V-4DA_html_40b4d6f7aabb6324.png|| class="img-thumbnail" height="115" width="600"]]265 +[[image:LX3V-4DA_html_40b4d6f7aabb6324.png||height="115" width="600" class="img-thumbnail"]] 297 297 ))) 298 298 1. After turning on or off the 24 VDC power for analog signals, the analog output may fluctuate for approximately 1 second. This is due to time delays in the power supply from the MPU or differences in start time. For this reason, be sure to take preventive measures so that this output fluctuation will not affect the external units. 299 299 ... ... @@ -304,16 +304,13 @@ 304 304 The standard characteristics (factory default) are shown by the solid lines in the figure below. These characteristics can be adjusted according to the conditions of the user’s system. 305 305 306 306 (% style="text-align:center" %) 307 -[[image:LX3V-4DA_html_fb0ea795f3721075.png|| class="img-thumbnail" height="354" width="1000"]]276 +[[image:LX3V-4DA_html_fb0ea795f3721075.png||height="354" width="1000" class="img-thumbnail"]] 308 308 309 -Gain value: Analog output value when the digital input is +1,000; 278 +* Gain value: Analog output value when the digital input is +1,000; 279 +* Offset value: Analog output value when the digital input is 0; 280 +* When the slope of the I/O characteristic line is steep: slight changes to the digital input will greatly increase or reduce the analog output. 281 +* When the slope of the I/O characteristic line is gentle: slight changes to the digital input will not always change the analog output. 310 310 311 -Offset value: Analog output value when the digital input is 0; 312 - 313 -When the slope of the I/O characteristic line is steep: slight changes to the digital input will greatly increase or reduce the analog output. 314 - 315 -When the slope of the I/O characteristic line is gentle: slight changes to the digital input will not always change the analog output. 316 - 317 317 **Adjustment of I/O Characteristics** 318 318 319 319 * To adjust the I/O characteristics, set the offset and gain of the LX3V-4DA either using push button switches connected to input terminals of the programmable controller or using the forced on/off function of a programming panel. To change the offset and gain, just change the conversion constants of the LX3V-4DA. Metering of the analog output is not needed for adjustment; however a program should be created in the MPU. ... ... @@ -320,40 +320,40 @@ 320 320 * An example program for adjustment is shown below. The example shows that for channel CH2 of LX3V-4DA block No.1, the offset value is changed to 7 mA, and the gain value to 20 mA. Note that for CH1, CH3, and CH4. 321 321 322 322 (% style="text-align:center" %) 323 -[[image:LX3V-4DA_html_4a8b657f5c76b2ee.png|| class="img-thumbnail" height="558" width="800"]]289 +[[image:LX3V-4DA_html_4a8b657f5c76b2ee.png||height="558" width="800" class="img-thumbnail"]] 324 324 325 325 (% style="text-align:center" %) 326 -[[image:LX3V-4DA_html_c84bc0ab8f54de6f.png|| class="img-thumbnail" height="252" width="300"]]292 +[[image:LX3V-4DA_html_c84bc0ab8f54de6f.png||height="252" width="300" class="img-thumbnail"]] 327 327 328 328 = **8 Outline of FROM and TO** = 329 329 330 330 For a detailed description, please refer to the LX3V PLC programming manual. 331 331 332 -* *Read BFM**298 +**Read BFM** 333 333 334 334 ((( 335 335 BFM#30 of special unit No.1→D0 336 336 337 337 (% style="text-align:center" %) 338 -[[image:LX3V-4DA_html_a1291f1fe8cf7f36.png|| class="img-thumbnail" height="67" width="300"]]304 +[[image:LX3V-4DA_html_a1291f1fe8cf7f36.png||height="67" width="300" class="img-thumbnail"]] 339 339 ))) 340 340 341 - 1.**m1:** Special unit or block number (K0 to K7, numbered from the MPU)342 - 1.**m2:** Buffer memory head address (K0 to K31)343 - 1.**D.:** Head device number of destination data. T, C, D, KnM, KnY, KnS, V and Z can be used to designate the head device. Each device number can be qualified using an index.344 - 1.**n:** Number of transfer points (K1 to K32) (K1 to K16 for 32-bit command)307 +* **m1:** Special unit or block number (K0 to K7, numbered from the MPU) 308 +* **m2:** Buffer memory head address (K0 to K31) 309 +* **D.:** Head device number of destination data. T, C, D, KnM, KnY, KnS, V and Z can be used to designate the head device. Each device number can be qualified using an index. 310 +* **n:** Number of transfer points (K1 to K32) (K1 to K16 for 32-bit command) 345 345 346 -* *Write BFM**312 +**Write BFM** 347 347 348 348 ((( 349 349 D2 and D3 →BFM#1 and #2 of special unit No.1 350 350 351 351 (% style="text-align:center" %) 352 -[[image:LX3V-4DA_html_8a0cda9fad9fac35.png|| class="img-thumbnail" height="67" width="300"]]318 +[[image:LX3V-4DA_html_8a0cda9fad9fac35.png||height="67" width="300" class="img-thumbnail"]] 353 353 ))) 354 354 355 - 1.**m1, m2, n:** Same as read BFM356 - 1.**S.: **Head device number of source data. T, C, D, KnX, KnM, KnY, KnS, V, Z, K and H can be used to designate the head device. Each device number can be qualified using an index.321 +* **m1, m2, n:** Same as read BFM 322 +* **S.: **Head device number of source data. T, C, D, KnX, KnM, KnY, KnS, V, Z, K and H can be used to designate the head device. Each device number can be qualified using an index. 357 357 358 358 When X010 and X011 are off, transfer will not be executed, therefore the destination data value will not be changed. 359 359 ... ... @@ -380,7 +380,7 @@ 380 380 381 381 On or off: The ambient conditions are not suitable for the LX3V-4DA, or the LX3V-4DA is defective. 382 382 383 - 1.Check that the external load resistance connected to each analog output terminal does not exceed the capacity of the LX3V-4DA drive (voltage output: 2kΩ to 1 MΩ / current output: 500Ω).384 - 1.Check the output voltage or current value using a voltmeter or ammeter, and confirm that the output meets the I/O characteristics. If the output does not meet the I/O characteristics, adjust the offset and gain again. Refer to section 8.349 +* Check that the external load resistance connected to each analog output terminal does not exceed the capacity of the LX3V-4DA drive (voltage output: 2kΩ to 1 MΩ / current output: 500Ω). 350 +* Check the output voltage or current value using a voltmeter or ammeter, and confirm that the output meets the I/O characteristics. If the output does not meet the I/O characteristics, adjust the offset and gain again. Refer to section 8. 385 385 386 386 To test the withstand voltage of the LX3V-4DA, connect all the terminals to the grounding terminal.