@@ -62,14 +62,14 @@ |
62 |
62 |
|=#5(E)|(% colspan="3" %)Holding mode |
63 |
63 |
|=#6|(% colspan="3" %)Reserved |
64 |
64 |
|=#7|(% colspan="3" %)Reserved |
65 |
|
-|=#8(E)|(% colspan="3" %)Offset/gain setting command CH1,CH2 default :H0000 |
66 |
|
-|=#9(E)|(% colspan="3" %)Offset/gain setting command CH3,CH4 default :H0000 |
|
65 |
+|=#8(E)|(% colspan="3" %)Offset/gain setting command CH1,CH2 default: H0000 |
|
66 |
+|=#9(E)|(% colspan="3" %)Offset/gain setting command CH3,CH4 default: H0000 |
67 |
67 |
|=#10|(% colspan="2" %)Offset data CH1*1|(% rowspan="8" %)((( |
68 |
68 |
Unit: mV or μA |
69 |
69 |
|
70 |
|
-Default offset value:0 |
|
70 |
+Default offset value: 0 |
71 |
71 |
|
72 |
|
-Default gain value:+5000, |
|
72 |
+Default gain value: +5000, |
73 |
73 |
|
74 |
74 |
Output mode 0 |
75 |
75 |
))) |
... |
... |
@@ -145,6 +145,8 @@ |
145 |
145 |
[[image:LX3V-4DA_html_7af7e1524e66e172.png||height="97" width="400" class="img-thumbnail"]] |
146 |
146 |
))) |
147 |
147 |
|
|
148 |
+**Formula for Gain/Offset: Analog output=Digital input*(Gain-Offset)/Constant+Offset** |
|
149 |
+ |
148 |
148 |
**[BFM #10 ~~ #17]** |
149 |
149 |
|
150 |
150 |
Offset/gain data: The offset and gain values are changed by writing new data to BFM #10 through #17. The units of the data to be written are mV or µA. The data should be written and then BFM #8 and #9 set. Note that the data value will be rounded down to the nearest 5mV or 20µA. |