Changes for page LX3V-4LTC
Last modified by Devin Chen on 2024/11/22 09:42
From version 4.1
edited by Mora Zhou
on 2023/11/22 10:31
on 2023/11/22 10:31
Change comment:
There is no comment for this version
To version 8.1
edited by Devin Chen
on 2024/11/22 09:42
on 2024/11/22 09:42
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Mora1 +XWiki.DevinChen - Content
-
... ... @@ -88,7 +88,7 @@ 88 88 (% class="table-bordered" style="width:1117px" %) 89 89 |=(% rowspan="2" scope="row" style="width: 253px;" %)**Item**|=(% colspan="2" style="width: 378px;" %)**Centigrade (°C)**|=(% colspan="2" style="width: 445px;" %)**Fahrenheit (°F)** 90 90 |(% colspan="4" style="width:715px" %)Both °C and °F are available by reading the appropriate buffer memory (BFM). 91 -|(% style="width:253px" %)Input signal|(% colspan="4" style="width:823px" %)Thermocouple: Type K, J, T, E, N, B, R, S ( each type can be used for each channel), 4 channels most.91 +|(% style="width:253px" %)Input signal|(% colspan="4" style="width:823px" %)Thermocouple: Type K, J, T, E, N, B, R, S (Each type can be used for each channel), 4 channels most. 92 92 |(% rowspan="8" style="width:253px" %)((( 93 93 Rated temperature range 94 94 )))|(% style="width:130px" %)Type K|(% style="width:248px" %)-100 to +1,200|(% style="width:147px" %)Type K|(% style="width:298px" %)-148 to +2,192 ... ... @@ -175,7 +175,7 @@ 175 175 |=(% colspan="2" %)((( 176 176 **Conversion Characteristics** 177 177 178 -Readings given at calibration reference point 0°C/32°F (0/320) respectively. ( subject to the overall accuracy)178 +Readings given at calibration reference point 0°C/32°F (0/320) respectively. (Subject to the overall accuracy) 179 179 ))) 180 180 |[[image:LX3V-4LTC_html_92edc788ec28d1cf.gif||class="img-thumbnail"]]|[[image:LX3V-4LTC_html_304483742690ee7c.gif||class="img-thumbnail"]] 181 181 ... ... @@ -284,8 +284,8 @@ 284 284 * Other: Starts control; 285 285 ))) 286 286 |(% style="width:55px" %)#48|(% style="width:12px" %)#86|(% style="width:52px" %)#124|(% style="width:65px" %)#162|(% style="width:143px" %)Auto/manual mode changeover|(% style="width:68px" %)0|(% style="width:77px" %)W/R|(% style="width:104px" %)0|(% style="width:348px" %)((( 287 -* 0: A UTO;288 -* Other: M AN;287 +* 0: Autol mode; 288 +* Other: Manual mode; 289 289 ))) 290 290 |(% style="width:55px" %)#49|(% style="width:12px" %)#87|(% style="width:52px" %)#125|(% style="width:65px" %)#163|(% style="width:143px" %)Manual output set value|(% style="width:68px" %)0|(% style="width:77px" %)W/R|(% style="width:104px" %)0|(% style="width:348px" %)The value is equal to the value of control output in manual mode. 291 291 |(% style="width:55px" %)#50|(% style="width:12px" %)#88|(% style="width:52px" %)#126|(% style="width:65px" %)#164|(% style="width:143px" %)Self-tuning execution command|(% style="width:68px" %)0|(% style="width:77px" %)W/R|(% style="width:104px" %)0|(% style="width:348px" %)((( ... ... @@ -389,6 +389,8 @@ 389 389 ))) 390 390 |(% style="width:55px" %)#76~~#80|(% style="width:12px" %)#114~~#118|(% style="width:52px" %)#152~~#156|(% style="width:65px" %)#190~~#193|(% style="width:143px" %)Reserved|(% style="width:68px" %)-|(% style="width:77px" %)-|(% style="width:104px" %)-|(% style="width:348px" %)Reserved 391 391 392 +(% class="box infomessage" %) 393 +((( 392 392 **✎Note: ** 393 393 394 394 * 0: Retentive; ... ... @@ -395,6 +395,7 @@ 395 395 * X: Non-retentive; 396 396 * R: Only read is enabled; 397 397 * R/W: Both read and write are enabled; 400 +))) 398 398 399 399 **Details of buffer memories** 400 400 ... ... @@ -457,6 +457,17 @@ 457 457 458 458 The identification code or ID number for this Special Block is read from buffer memory BFM #30 by FROM instruction. This number for the LX3V-4LTC unit is K2130. The PLC can use this ID in program to identify the special block before commencing data transfer to and from the special block. 459 459 463 +**Power-down retention flag BFM#42** 464 + 465 +First, configure the parameters to be saved, and then set the power-down retention flag BFM#42 to 1. This enables power-down retention for the configured parameters. 466 + 467 +The operation steps are illustrated as follows: 468 + 469 +1. Set the power-down retention register to a value of 100 (e.g., BFM#52 is set to 100). 470 +1. Set the power-down retention flag BFM#42 to 1 (data is saved at this point, and BFM#42 will automatically reset to zero upon completion). 471 +1. Change the data of the power-down retention register to 1000 (e.g., BFM#52 is set to 1000). 472 +1. Power off and then power on again. At this point, check the value of the power-down retention register, which should be 100 (e.g., BFM#52 shows a value of 100)." 473 + 460 460 **Error flag BFM #43, BFM#81, BFM#119, BFM#157 (Temperature control is stopped)** 461 461 462 462 ((( ... ... @@ -599,6 +599,8 @@ 599 599 |(% style="width:88px" %)11|(% style="width:238px" %)Alarm for Upper/lower limit deviation with wait|(% style="width:608px" %)Alarms if absolute deviation (= Measured value (PV) – Set value (SV)) is less than value of alarm. However, measured value is ignored at the start of system.|(% style="width:141px" %)+Input width 600 600 ))) 601 601 616 +(% class="box infomessage" %) 617 +((( 602 602 **✎Note: ** 603 603 604 604 * Input range: it is from the lower threshold to the upper threshold of input value ... ... @@ -605,6 +605,7 @@ 605 605 * Input width: Width from the lower threshold to the upper threshold of input value (Input width = Upper threshold value - Lower threshold value). 606 606 * ±Input width: it could be positive and negative. 607 607 * + Input width: it could be positive only. 624 +))) 608 608 609 609 **Alarm dead zone setting** 610 610