44 44  
45 45  Please install the end cover on the right side of the last expansion module, align it with the module interface slot and connect it, as shown in the figure below:
46 46  
47 -(% style="text-align:center" %)
48 -[[image:图片7.png||height="303" width="577"]]
49 49  
50 -== **2.4** **Wiring instruction diagram** ==
51 -
52 -When using the 4PT expansion module, the wiring method of the sensor is as shown in the following diagrams:
53 -
54 54  (% style="text-align:center" %)
55 -[[image:123.wmf]]
49 +[[image:1761790902574-569.png||height="377" width="719"]]
56 56  
57 57  == **2.4 Indicator** ==
58 58  
... ... @@ -83,9 +83,9 @@
83 83  |=L1-/L2-/L3-/L4-|(% style="text-align:center" %)N/A
84 84  |=I1+/I2+/I3+/I4 +|(% style="text-align:center" %)N/A
85 85  
86 -= **3 Parameter Specification** =
80 +== **3 Parameter Specification** ==
87 87  
88 -== **3.1 Input Specification** ==
82 +=== **3.1 Input Specification** ===
89 89  
90 90  (% style="margin-left:auto; margin-right:auto" %)
91 91  |=**Item**|=**Description**
... ... @@ -205,7 +205,7 @@
205 205  == **4.1 Use on LX6V/LX6S** ==
206 206  
207 207  (% style="text-align:center" %)
208 -[[image:图片8.png]]
202 +[[image:1761791554402-822.png||height="324" width="537"]]
209 209  
210 210  **(1 ) Add Module**
211 211  
... ... @@ -264,24 +264,22 @@
264 264  
265 265  After the module configuration is completed and the program is compiled correctly, the project can be downloaded (at present, it is not supported to download the extension module configuration separately). Before downloading, make sure that the connected expansion module model and configuration model are in the same order. Otherwise, the PLC will report an error and stop running.
266 266  
267 -(% style="text-align:center" %)
268 -[[image:图片2.png]]
269 269  
262 +
270 270  == **4.2 Used on LX6V-EM□-ECAT coupler** ==
271 271  
272 272  (% style="text-align:center" %)
273 273  [[image:1761791932607-101.png]]
274 274  
268 +
275 275  **(1) First  add EtherCAT device**
276 276  
277 277  According to steps ① to ④ in the figure below, right-click EtherCAT, and click [New]->[Import] to import the ESI device description file of the device;
278 278  
279 -(% style="text-align:center" %)
280 -[[image:图片3.png]]
273 +[[image:1761790435601-438.jpeg]]
281 281  
282 282  After the import is completed, select the coupler according to the module model and location connected to PLC. (the figure below takes LX6V-EMB-ECAT as an example);
283 283  
284 -(% style="text-align:center" %)
285 285  [[image:1761790435610-644.jpeg]]
286 286  
287 287  **(2) Configuration module**
... ... @@ -288,20 +288,18 @@
288 288  
289 289  Right-click the currently added coupler to add the expansion module mounted to the current coupler.
290 290  
291 -(% style="text-align:center" %)
292 -[[image:图片4.png]]
283 +[[image:1761790435616-427.jpeg]]
293 293  
294 294  **✎Note: **When the configuration module is inconsistent with the actual mounted module, an error will be reported that the OP cannot be successful.
295 295  
296 296  **(3) Start configuration**
297 297  
298 -(% style="text-align:center" %)
299 -[[image:图片5.png||alt="1761790435644-648.jpeg"]]
289 +[[image:1761790435644-648.jpeg]]
300 300  
301 301  
302 -(% style="text-align:center" %)
303 -[[image:图片6.png]]
292 +[[image:1761790435655-470.jpeg]]
304 304  
294 +
305 305  ① PT module temperature unit: Set the temperature unit for the module output. The supported temperature unit types are Celsius (℃) or Fahrenheit (℉), the default unit is: Celsius;
306 306  
307 307  0: Degree Celsius (℃);
... ... @@ -342,7 +342,6 @@
342 342  
343 343  The temperature and state of the module can be mapped to variables/device. For example, the following figure maps the temperature values of the CH0 to CH3 channels to the D0 to D7 device, and the status codes of the CH0 to CH3 channels to the D8 to D11 device.
344 344  
345 -(% style="text-align:center" %)
346 346  [[image:1761790435666-763.jpeg]]
347 347  
348 348  Click save configuration and download the configuration to PLC.
123.wmf
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -81.9 KB
Content
图片3.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -3.0 MB
Content
图片4.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -4.8 MB
Content
图片5.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -4.8 MB
Content
图片6.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -4.8 MB
Content
图片7.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -581.1 KB
Content
图片8.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -491.0 KB
Content