1 1  = **1 Introduction** =
2 2  
3 3  (% style="text-align:center" %)
4 -[[image:1761790581619-130.png||height="397" width="397"]]
4 +[[image:1761790581619-130.png||height="359" width="359"]]
5 5  
6 +
6 6  LX6V-4PT (4-channal analog inputs), used for the acquisition of thermocouple input analog signals. Suitable for Wecon LX6 series PLC and LX6V-EM□-ECAT coupler.
7 7  
8 8  LX6V-EM□-ECAT firmware version that supports this module: V2.022 and above, the corresponding XML version: 1.3 and above.
... ... @@ -18,6 +18,7 @@
18 18  (% style="text-align:center" %)
19 19  [[image:1761790728530-525.png]]
20 20  
22 +
21 21  ① LED; ② Terminal; ③ Expansion module interface; ④ Mounting hole: 2 places (Φ4.5); ⑤ DIN rail buckle.
22 22  
23 23  == **2.2 Terminal description** ==
... ... @@ -46,7 +46,7 @@
46 46  
47 47  
48 48  (% style="text-align:center" %)
49 -[[image:1761790902574-569.png||height="377" width="719"]]
51 +[[image:1761790902574-569.png]]
50 50  
51 51  == **2.4 Indicator** ==
52 52  
... ... @@ -79,7 +79,7 @@
79 79  
80 80  == **3 Parameter Specification** ==
81 81  
82 -=== **3.1 Input Specification** ===
84 +=== **3.1 ​​​​​​​Input Specification** ===
83 83  
84 84  (% style="margin-left:auto; margin-right:auto" %)
85 85  |=**Item**|=**Description**
... ... @@ -159,7 +159,7 @@
159 159  |(% style="text-align:center" %)Channel diagnosis|(% style="text-align:center" %)Over upper limit alarm, over lower limit alarm, disconnection alarm, overflow alarm
160 160  |(% style="text-align:center" %)Configuration diagnostics|(% style="text-align:center" %)Configuration error identification, channel parameter configuration error
161 161  
162 -== **3.4 Accuracy calculation** ==
164 +== **​​​​​​​3.4 Accuracy calculation** ==
163 163  
164 164  Within the working temperature range, when the temperature change rate is less than 0.3°C/min, the accuracy of this product = ADC sampling accuracy + line resistance error + contact impedance error. According to the measure principle, it is necessary to wait for the module to be powered on for 45 minutes before measuring.
165 165  
... ... @@ -196,10 +196,10 @@
196 196  
197 197  This module is suitable for Wecon LX6 series PLC and LX6V-EM□-ECAT coupler. The two usage methods are as follow.
198 198  
199 -== **4.1 Use on LX6V/LX6S** ==
201 +== **​​​​​​​4.1 Use on LX6V/LX6S** ==
200 200  
201 201  (% style="text-align:center" %)
202 -[[image:1761791554402-822.png||height="324" width="537"]]
204 +[[image:1761791554402-822.png]]
203 203  
204 204  **(1 ) Add Module**
205 205  
... ... @@ -212,13 +212,12 @@
212 212  ③ Double-click the module in the current machine slot to open the parameter configuration interface;
213 213  
214 214  (% style="text-align:center" %)
215 -[[image:图片1.png]]
217 +[[image:1761790435581-926.jpeg]]
216 216  
217 217  **(2) Configuration module**
218 218  
219 219  **~ 1) General configuration**
220 220  
221 -(% style="text-align:center" %)
222 222  [[image:1761790435591-998.jpeg]]
223 223  
224 224  ① Temperature unit: Set the temperature unit for the module output. The supported temperature unit types are Celsius (℃) or Fahrenheit (℉), the default unit is: Celsius;
... ... @@ -227,7 +227,6 @@
227 227  
228 228  **~ 2) Channel configuration**
229 229  
230 -(% style="text-align:center" %)
231 231  [[image:1761790435593-675.jpeg]]
232 232  
233 233  ① Enable channels: It can be set whether to enable the current expansion module channel;
... ... @@ -244,8 +244,7 @@
244 244  
245 245  By default, channels are mapped to R device according to the number of current module channels. The figure below maps modules CH1 ~~ CH12 to R0 ~~ R11 device. The data type of temperature value of channel is REAL. If want to display the temperature value of channel 1, the temperature value can be viewed after assigning a variable using the DEMOV instruction.
246 246  
247 -(% style="text-align:center" %)
248 -[[image:1761790435595-524.jpeg||height="638" width="806"]]
247 +[[image:1761790435595-524.jpeg]]
249 249  
250 250  Supported status codes:
251 251  
... ... @@ -258,10 +258,10 @@
258 258  
259 259  After the module configuration is completed and the program is compiled correctly, the project can be downloaded (at present, it is not supported to download the extension module configuration separately). Before downloading, make sure that the connected expansion module model and configuration model are in the same order. Otherwise, the PLC will report an error and stop running.
260 260  
260 +[[image:1761790435597-964.jpeg]]
261 261  
262 +== ​​​​​​​**4.2 Used on LX6V-EM□-ECAT coupler** ==
262 262  
263 -== **4.2 Used on LX6V-EM□-ECAT coupler** ==
264 -
265 265  (% style="text-align:center" %)
266 266  [[image:1761791932607-101.png]]
267 267  
1761792561604-505.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -977.1 KB
Content
1761792587489-425.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -977.1 KB
Content
1761792704532-635.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -299.8 KB
Content
1761792792216-675.jpeg
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -500.0 KB
Content
图片1.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -4.8 MB
Content
图片2.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -4.1 MB
Content