1 General
This manual is applied to LX3V-8EX and LX3V-16EX digital input expansion modules.
2 Naming rule
Naming rule of LX3V I/O input expansion module:
- WECON PLC;
- Main module;
- Expansion module;
- Product type, E means expansion;
- Expansion input(X);
3 Dimensions
- Extension cable and connector
- State LED: Light when normal condition
- Power LED: Light when connect to 24V
- Module name
- digital signal output terminal
- Extension module interface
- DIN rail mounting slot
- DIN rail hook
- Mounting holes (φ4.5)
3.1 Crimp terminations
- Please use crimp terminals as indicated on the graph.
- The tightening torque should be applied 5 to 8 Kg.cm.
- Other terminals should be empty but only wiring terminals mention in this manual.
4 Output specification
Item | DC input |
Mode | LX3V-16EX |
Output circuit | |
Input voltage | DC ± 24V ± 10% *1 |
Input current | 5mA/ DC 24V |
Input ON current | More than 3.5mA |
Input OFF current | Less than 1.5mA |
Input response time | About 10ms |
X0~X7 built-in digital filter, setting time 0 ~ 60ms | |
Input signal | Contactor NPN or PNP |
Circuit insulation | Photo-coupling |
LED | Lights when input is energized |