Changes for page LX3V-8EX/16EX
Last modified by Jim on 2022/12/15 14:00
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -15,10 +15,10 @@ 15 15 16 16 = **2 Dimensions ** = 17 17 18 - [[image:image-20220704141033-9.png||height="404" width="358"]] [[image:image-20220704141040-10.png||height="375" width="370"]] 18 + [[image:image-20220704141033-9.png||height="404" width="358" class="img-thumbnail"]] [[image:image-20220704141040-10.png||height="375" width="370" class="img-thumbnail"]] 19 19 20 20 (% style="text-align:center" %) 21 -[[image:image-20220704141048-11.png||height="729" width="859"]] 21 +[[image:image-20220704141048-11.png||height="729" width="859" class="img-thumbnail"]] 22 22 23 23 1. Extension cable 24 24 1. Input indicator light of each channel ... ... @@ -30,17 +30,20 @@ 30 30 1. DIN rail hook 31 31 1. Mounting holes (φ4.5) 32 32 33 -|Name|(% style="width:47 5px" %)Description|(% style="width:145px" %)Status|(% style="width:508px" %)Event status34 -|(% rowspan="3" %)LINK|(% rowspan="3" style="width:47 5px" %)Communication indicator between PLC and expansion module|(% style="width:145px" %)Flashes|(% style="width:508px" %)Normal data transmission(normal communication)35 -|(% style="width:1 45px" %)OFF|(% style="width:508px" %)Data transmission is abnormal, stopped, or failed36 -|(% style="width:1 45px" %)ON|(% style="width:508px" %)Software is abnormal or hardware is faulty33 +|=(% scope="row" style="width: 72px;" %)Name|=(% style="width: 437px;" %)Description|=(% style="width: 151px;" %)Status|=(% style="width: 419px;" %)Event status 34 +|=(% rowspan="3" style="width: 72px;" %)LINK|(% rowspan="3" style="width:437px" %)Communication indicator between PLC and expansion module|(% style="width:151px" %)Flashes|(% style="width:419px" %)Normal data transmission(normal communication) 35 +|=(% style="width: 151px;" %)OFF|(% style="width:419px" %)Data transmission is abnormal, stopped, or failed 36 +|=(% style="width: 151px;" %)ON|(% style="width:419px" %)Software is abnormal or hardware is faulty 37 37 38 +(% class="box infomessage" %) 39 +((( 38 38 **✎Note:** Except different I/O input points, LX3V-8EX and LX3V-16EX have the same dimensions and the same other functions. 41 +))) 39 39 40 -== **2.1Crimp terminals**==43 +== Crimp terminals == 41 41 42 42 (% style="text-align:center" %) 43 -[[image:image-20220704140755-3.png]] 46 +[[image:image-20220704140755-3.png||class="img-thumbnail"]] 44 44 45 45 1. Please use crimp terminals as indicated on the graph. 46 46 1. The tightening torque should be applied 5 to 8 Kg.cm. ... ... @@ -48,9 +48,12 @@ 48 48 49 49 = **3 Output specification** = 50 50 51 -|**Item**|**DC input** 54 +|=**Item**|=**DC input** 52 52 |Model|LX3V-8EX or LX3V-16EX 53 -|Output circuit|[[image:image-20220704140755-4.png]] 56 +|Output circuit|((( 57 +(% style="text-align:center" %) 58 +[[image:image-20220704140755-4.png]] 59 +))) 54 54 |Input signal voltage|DC ± 24V ± 10% *1 55 55 |Input signal current|5mA/ DC 24V 56 56 |Input ON current|More than 3.5mA ... ... @@ -69,14 +69,17 @@ 69 69 1. If you expand an LX3V-16EX module on the host, the X points defined in the module on the host are X20 to X27 and X30 to X37. 70 70 1. If you expand multiple I/O input point modules on the host, the I/Os on the module will be named in the same order. 71 71 78 +(% class="box infomessage" %) 79 +((( 72 72 **✎Note: **When adding IO expansion modules to the host, in principle, the number of all input points X must not exceed 256 points. When adding IO expansion modules to the host, if the host needs to connect multiple IO modules, it is recommended to add a separate power supply board to the module for power supply. 81 +))) 73 73 74 74 = **5 Program** = 75 75 76 -[[image:image-20220704141326-13.png]] 85 +[[image:image-20220704141326-13.png||class="img-thumbnail"]] 77 77 78 78 As shown in the example above, it is LX3V-3624MT with two LX3V-16EX modules and one LX3V-4DA module. The host has 36 input points X: X0 to X7, X10 to X17, X20 to X27. X30 to X37 and X40 to X43. The input point in the module ① called by host are X50 to X57 and X60 to X67, and the input points in the module ③ called by host are X70 to X77 and X80 to X87. 79 79 80 -[[image:image-20220704141313-12.png]] 89 +[[image:image-20220704141313-12.png||class="img-thumbnail"]] 81 81 82 82 As shown in the example above, it is LX3V-3624MT with one LX3V-16EX and two LX3V-4DA modules. The host has 36 input points X: X0 to X7, X10 to X17, X20 to X27, X30 to X37 and X40 to X43. The input point in the module ③ called by host are X50 to X57 and X60 to X67.