... ... @@ -15,10 +15,10 @@
15 15  
16 16  = **2 Dimensions ** =
17 17  
18 - [[image:image-20220704141033-9.png||height="404" width="358" class="img-thumbnail"]] [[image:image-20220704141040-10.png||height="375" width="370" class="img-thumbnail"]]
18 + [[image:image-20220704141033-9.png||height="404" width="358"]] [[image:image-20220704141040-10.png||height="375" width="370"]]
19 19  
20 20  (% style="text-align:center" %)
21 -[[image:image-20220704141048-11.png||height="729" width="859" class="img-thumbnail"]]
21 +[[image:image-20220704141048-11.png||height="729" width="859"]]
22 22  
23 23  1. Extension cable
24 24  1. Input indicator light of each channel
... ... @@ -30,20 +30,17 @@
30 30  1. DIN rail hook
31 31  1. Mounting holes (φ4.5)
32 32  
33 -|=(% scope="row" style="width: 72px;" %)Name|=(% style="width: 437px;" %)Description|=(% style="width: 151px;" %)Status|=(% style="width: 419px;" %)Event status
34 -|=(% rowspan="3" style="width: 72px;" %)LINK|(% rowspan="3" style="width:437px" %)Communication indicator between PLC and expansion module|(% style="width:151px" %)Flashes|(% style="width:419px" %)Normal data transmission(normal communication)
35 -|=(% style="width: 151px;" %)OFF|(% style="width:419px" %)Data transmission is abnormal, stopped, or failed
36 -|=(% style="width: 151px;" %)ON|(% style="width:419px" %)Software is abnormal or hardware is faulty
33 +|Name|(% style="width:475px" %)Description|(% style="width:145px" %)Status|(% style="width:508px" %)Event status
34 +|(% rowspan="3" %)LINK|(% rowspan="3" style="width:475px" %)Communication indicator between PLC and expansion module|(% style="width:145px" %)Flashes|(% style="width:508px" %)Normal data transmission(normal communication)
35 +|(% style="width:145px" %)OFF|(% style="width:508px" %)Data transmission is abnormal, stopped, or failed
36 +|(% style="width:145px" %)ON|(% style="width:508px" %)Software is abnormal or hardware is faulty
37 37  
38 -(% class="box infomessage" %)
39 -(((
40 40  **✎Note:** Except different I/O input points, LX3V-8EX and LX3V-16EX have the same dimensions and the same other functions.
41 -)))
42 42  
43 -== Crimp terminals ==
40 +== **2.1 Crimp terminals** ==
44 44  
45 45  (% style="text-align:center" %)
46 -[[image:image-20220704140755-3.png||class="img-thumbnail"]]
43 +[[image:image-20220704140755-3.png]]
47 47  
48 48  1. Please use crimp terminals as indicated on the graph.
49 49  1. The tightening torque should be applied 5 to 8 Kg.cm.
... ... @@ -51,12 +51,9 @@
51 51  
52 52  = **3 Output specification** =
53 53  
54 -|=**Item**|=**DC input**
51 +|**Item**|**DC input**
55 55  |Model|LX3V-8EX or LX3V-16EX
56 -|Output circuit|(((
57 -(% style="text-align:center" %)
58 -[[image:image-20220704140755-4.png]]
59 -)))
53 +|Output circuit|[[image:image-20220704140755-4.png]]
60 60  |Input signal voltage|DC ± 24V ± 10% *1
61 61  |Input signal current|5mA/ DC 24V
62 62  |Input ON current|More than 3.5mA
... ... @@ -75,17 +75,14 @@
75 75  1. If you expand an LX3V-16EX module on the host, the X points defined in the module on the host are X20 to X27 and X30 to X37.
76 76  1. If you expand multiple I/O input point modules on the host, the I/Os on the module will be named in the same order.
77 77  
78 -(% class="box infomessage" %)
79 -(((
80 80  **✎Note: **When adding IO expansion modules to the host, in principle, the number of all input points X must not exceed 256 points. When adding IO expansion modules to the host, if the host needs to connect multiple IO modules, it is recommended to add a separate power supply board to the module for power supply.
81 -)))
82 82  
83 83  = **5 Program** =
84 84  
85 -[[image:image-20220704141326-13.png||class="img-thumbnail"]]
76 +[[image:image-20220704141326-13.png]]
86 86  
87 87  As shown in the example above, it is LX3V-3624MT with two LX3V-16EX modules and one LX3V-4DA module. The host has 36 input points X: X0 to X7, X10 to X17, X20 to X27. X30 to X37 and X40 to X43. The input point in the module ① called by host are X50 to X57 and X60 to X67, and the input points in the module ③ called by host are X70 to X77 and X80 to X87.
88 88  
89 -[[image:image-20220704141313-12.png||class="img-thumbnail"]]
80 +[[image:image-20220704141313-12.png]]
90 90  
91 91  As shown in the example above, it is LX3V-3624MT with one LX3V-16EX and two LX3V-4DA modules. The host has 36 input points X: X0 to X7, X10 to X17, X20 to X27, X30 to X37 and X40 to X43. The input point in the module ③ called by host are X50 to X57 and X60 to X67.