Changes for page LX3V-8EX/16EX
Last modified by Jim on 2022/12/15 14:00
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -LX3V- 8EX/16EX1 +LX3V-16EX - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.Stone - Content
-
... ... @@ -15,10 +15,10 @@ 15 15 16 16 = **2 Dimensions ** = 17 17 18 - [[image:image-20220704141033-9.png||height="404" width="358" class="img-thumbnail"]] [[image:image-20220704141040-10.png||height="375" width="370"class="img-thumbnail"]]18 + [[image:image-20220704141033-9.png||height="404" width="358"]] [[image:image-20220704141040-10.png||height="375" width="370"]] 19 19 20 20 (% style="text-align:center" %) 21 -[[image:image-20220704141048-11.png||height="729" width="859" class="img-thumbnail"]]21 +[[image:image-20220704141048-11.png||height="729" width="859"]] 22 22 23 23 1. Extension cable 24 24 1. Input indicator light of each channel ... ... @@ -30,20 +30,17 @@ 30 30 1. DIN rail hook 31 31 1. Mounting holes (φ4.5) 32 32 33 -| =(% scope="row" style="width: 72px;" %)Name|=(% style="width:37px;" %)Description|=(% style="width:1px;" %)Status|=(% style="width:419px;" %)Event status34 -| =(% rowspan="3"style="width: 72px;"%)LINK|(% rowspan="3" style="width:437px" %)Communication indicator between PLC and expansion module|(% style="width:151px" %)Flashes|(% style="width:419px" %)Normal data transmission(normal communication)35 -| =(% style="width:1px;" %)OFF|(% style="width:419px" %)Data transmission is abnormal, stopped, or failed36 -| =(% style="width:1px;" %)ON|(% style="width:419px" %)Software is abnormal or hardware is faulty33 +|Name|(% style="width:475px" %)Description|(% style="width:145px" %)Status|(% style="width:508px" %)Event status 34 +|(% rowspan="3" %)LINK|(% rowspan="3" style="width:475px" %)Communication indicator between PLC and expansion module|(% style="width:145px" %)Flashes|(% style="width:508px" %)Normal data transmission(normal communication) 35 +|(% style="width:145px" %)OFF|(% style="width:508px" %)Data transmission is abnormal, stopped, or failed 36 +|(% style="width:145px" %)ON|(% style="width:508px" %)Software is abnormal or hardware is faulty 37 37 38 -(% class="box infomessage" %) 39 -((( 40 40 **✎Note:** Except different I/O input points, LX3V-8EX and LX3V-16EX have the same dimensions and the same other functions. 41 -))) 42 42 43 -== Crimp terminals == 40 +== **2.1 Crimp terminals** == 44 44 45 45 (% style="text-align:center" %) 46 -[[image:image-20220704140755-3.png ||class="img-thumbnail"]]43 +[[image:image-20220704140755-3.png]] 47 47 48 48 1. Please use crimp terminals as indicated on the graph. 49 49 1. The tightening torque should be applied 5 to 8 Kg.cm. ... ... @@ -51,12 +51,9 @@ 51 51 52 52 = **3 Output specification** = 53 53 54 -| =**Item**|=**DC input**51 +|**Item**|**DC input** 55 55 |Model|LX3V-8EX or LX3V-16EX 56 -|Output circuit|((( 57 -(% style="text-align:center" %) 58 -[[image:image-20220704140755-4.png]] 59 -))) 53 +|Output circuit|[[image:image-20220704140755-4.png]] 60 60 |Input signal voltage|DC ± 24V ± 10% *1 61 61 |Input signal current|5mA/ DC 24V 62 62 |Input ON current|More than 3.5mA ... ... @@ -75,17 +75,14 @@ 75 75 1. If you expand an LX3V-16EX module on the host, the X points defined in the module on the host are X20 to X27 and X30 to X37. 76 76 1. If you expand multiple I/O input point modules on the host, the I/Os on the module will be named in the same order. 77 77 78 -(% class="box infomessage" %) 79 -((( 80 80 **✎Note: **When adding IO expansion modules to the host, in principle, the number of all input points X must not exceed 256 points. When adding IO expansion modules to the host, if the host needs to connect multiple IO modules, it is recommended to add a separate power supply board to the module for power supply. 81 -))) 82 82 83 83 = **5 Program** = 84 84 85 -[[image:image-20220704141326-13.png ||class="img-thumbnail"]]76 +[[image:image-20220704141326-13.png]] 86 86 87 -As shown in the example above, it is LX3V-3624MT with two LX3V-16EX modules and one LX3V-4DA module. The host has 36 input points X: X0 to X7, X10 to X17, X20 to X27. X30 to X37 and X40 to X43. The input point in the module ① called by host are X50 to X57 and X60 to X67, and the input points in the module ③ called by host are X70 to X77 and X 100to X107.78 +As shown in the example above, it is LX3V-3624MT with two LX3V-16EX modules and one LX3V-4DA module. The host has 36 input points X: X0 to X7, X10 to X17, X20 to X27. X30 to X37 and X40 to X43. The input point in the module ① called by host are X50 to X57 and X60 to X67, and the input points in the module ③ called by host are X70 to X77 and X80 to X87. 88 88 89 -[[image:image-20220704141313-12.png ||class="img-thumbnail"]]80 +[[image:image-20220704141313-12.png]] 90 90 91 91 As shown in the example above, it is LX3V-3624MT with one LX3V-16EX and two LX3V-4DA modules. The host has 36 input points X: X0 to X7, X10 to X17, X20 to X27, X30 to X37 and X40 to X43. The input point in the module ③ called by host are X50 to X57 and X60 to X67.