Changes for page LX3V-8EY/16EY

Last modified by Devin Chen on 2024/02/13 17:17

From version 5.1
edited by Stone Wu
on 2022/07/04 14:20
Change comment: There is no comment for this version
To version 6.1
edited by Stone Wu
on 2022/09/14 16:07
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -5,7 +5,7 @@
5 5  Naming rule of LX3V I/O output expansion module:
6 6  
7 7  (% style="text-align:center" %)
8 -[[image:image-20220704141604-1.png||height="82" width="300"]]
8 +[[image:image-20220704141604-1.png||height="82" width="300" class="img-thumbnail"]]
9 9  
10 10  
11 11  1. WECON PLC;
... ... @@ -17,10 +17,10 @@
17 17  
18 18  = **2 Dimensions** =
19 19  
20 - [[image:image-20220704141653-8.jpeg]] [[image:image-20220704141658-9.jpeg]]
20 + [[image:image-20220704141653-8.jpeg||class="img-thumbnail"]] [[image:image-20220704141658-9.jpeg||class="img-thumbnail"]]
21 21  
22 22  (% style="text-align:center" %)
23 -[[image:image-20220704141707-10.jpeg||height="838" width="986"]]
23 +[[image:image-20220704141707-10.jpeg||height="838" width="986" class="img-thumbnail"]]
24 24  
25 25  1. Extension cable
26 26  1. Input indicator light of each channel
... ... @@ -32,17 +32,20 @@
32 32  1. DIN rail hook
33 33  1. Mounting holes (φ4.5)
34 34  
35 -|Name|(% style="width:517px" %)Description|(% style="width:123px" %)Status|(% style="width:487px" %)Event status
36 -|(% rowspan="3" %)LINK|(% rowspan="3" style="width:517px" %)Communication indicator between PLC and expansion module|(% style="width:123px" %)Flashes|(% style="width:487px" %)Normal data transmission(normal communication)
37 -|(% style="width:123px" %)OFF|(% style="width:487px" %)Data transmission is abnormal, stopped, or failed
38 -|(% style="width:123px" %)ON|(% style="width:487px" %)Software is abnormal or hardware is faulty
35 +|=(% scope="row" style="width: 75px;" %)Name|=(% style="width: 460px;" %)Description|=(% style="width: 147px;" %)Status|=(% style="width: 417px;" %)Event status
36 +|=(% rowspan="3" style="width: 75px;" %)LINK|(% rowspan="3" style="width:460px" %)Communication indicator between PLC and expansion module|(% style="width:147px" %)Flashes|(% style="width:417px" %)Normal data transmission(normal communication)
37 +|=(% style="width: 147px;" %)OFF|(% style="width:417px" %)Data transmission is abnormal, stopped, or failed
38 +|=(% style="width: 147px;" %)ON|(% style="width:417px" %)Software is abnormal or hardware is faulty
39 39  
40 +(% class="box infomessage" %)
41 +(((
40 40  **✎Note:** Except different I/O input points, LX3V-8EY and LX3V-16EY have the same dimensions and the same other functions.
43 +)))
41 41  
42 -== **2.1 Crimp terminations** ==
45 +== Crimp terminations ==
43 43  
44 44  (% style="text-align:center" %)
45 -[[image:image-20220704141604-3.png]]
48 +[[image:image-20220704141604-3.png||class="img-thumbnail"]]
46 46  
47 47  1. Please use crimp terminals as indicated on the graph.
48 48  1. The tightening torque should be applied 5 to 8 Kg.cm.
... ... @@ -50,17 +50,16 @@
50 50  
51 51  = **3 Output specification** =
52 52  
53 -|(% colspan="2" %)**Item**|**Relay output**|**Transistor output**
54 -|(% colspan="2" %)ModeL|LX3V-8EYR/16EYR|LX3V-8EYT/16EYT
55 -|(% colspan="2" %)Output circuit|[[image:image-20220704141604-4.png]]|[[image:image-20220704141604-5.png]]
56 -|(% colspan="2" %)Power supply|Less than AC250V or DC 30V|DC 5V to 30V
57 -|(% colspan="2" %)Circuit insulation|Mechanical|Optocoupler insulation
58 -|(% colspan="2" %)LED|Light when relay is energized|Light when optocoupler is energized
59 -|(% rowspan="3" %)(((
60 -Max
61 -
62 -Load
63 -)))|Resistance|(((
56 +(% style="width:1125px" %)
57 +|=(% colspan="2" scope="row" style="width: 253px;" %)**Item**|=(% style="width: 416px;" %)**Relay output**|=**Transistor output**
58 +|=(% colspan="2" style="width: 253px;" %)Model|(% style="width:416px" %)LX3V-8EYR/16EYR|LX3V-8EYT/16EYT
59 +|=(% colspan="2" style="width: 253px;" %)Output circuit|(% style="width:416px" %)[[image:image-20220704141604-4.png||height="310" width="298" class="img-thumbnail"]]|[[image:image-20220704141604-5.png||height="306" width="287" class="img-thumbnail"]]
60 +|=(% colspan="2" style="width: 253px;" %)Power supply|(% style="width:416px" %)Less than AC250V or DC 30V|DC 5V to 30V
61 +|=(% colspan="2" style="width: 253px;" %)Circuit insulation|(% style="width:416px" %)Mechanical|Optocoupler insulation
62 +|=(% colspan="2" style="width: 253px;" %)LED|(% style="width:416px" %)Light when relay is energized|Light when optocoupler is energized
63 +|=(% rowspan="3" style="width: 113px;" %)(((
64 +Max load
65 +)))|(% style="width:140px" %)Resistance|(% style="width:416px" %)(((
64 64  2A/one point
65 65  
66 66  8A/four points
... ... @@ -73,12 +73,12 @@
73 73  
74 74  1.6A/eight points
75 75  )))
76 -|Inductance|80VA|12W/DC24V
77 -|Lamp|100W|1.5W/DC24V
78 -|(% colspan="2" %)Leakage current|-|0.1mA/ DC 30V
79 -|(% colspan="2" %)Minimum load|-|DC 5V 2mA
80 -|(% colspan="2" %)OFF->ON|About 10ms|Less than 0.2ms
81 -|(% colspan="2" %)ON-> OFF|About 10ms|Less than 0.2ms
78 +|=(% style="width: 140px;" %)Inductance|(% style="width:416px" %)80VA|12W/DC24V
79 +|=(% style="width: 140px;" %)Lamp|(% style="width:416px" %)100W|1.5W/DC24V
80 +|=(% colspan="2" style="width: 253px;" %)Leakage current|(% style="width:416px" %)-|0.1mA/ DC 30V
81 +|=(% colspan="2" style="width: 253px;" %)Minimum load|(% style="width:416px" %)-|DC 5V 2mA
82 +|=(% colspan="2" style="width: 253px;" %)OFF->ON|(% style="width:416px" %)About 10ms|Less than 0.2ms
83 +|=(% colspan="2" style="width: 253px;" %)ON-> OFF|(% style="width:416px" %)About 10ms|Less than 0.2ms
82 82  
83 83  = **4 Instructions** =
84 84  
... ... @@ -88,14 +88,17 @@
88 88  1. If you expand an LX3V-16EY module on the host , the Y points defined in the module on the host computer are X20 to X27 and X30 to X37.
89 89  1. If you expand multiple I/O output point modules on the host, the I/Os on the module will be named in the same order.
90 90  
93 +(% class="box infomessage" %)
94 +(((
91 91  **✎Note: **When adding IO expansion modules to the host, in principle, the number of all output points Y must not exceed 256 points. When adding IO expansion modules to the host, if the host needs to connect multiple IO modules, it is recommended to add a separate power supply board to the module for power supply.
96 +)))
92 92  
93 93  = **5 Program** =
94 94  
95 -[[image:image-20220704141847-12.jpeg]]
100 +[[image:image-20220704141847-12.jpeg||class="img-thumbnail"]]
96 96  
97 97  As shown in the example above, it is LX3V-3624MT with two LX3V-16EY modules and one LX3V-4DA module. The host has 24 output points Y: Y0 to Y7, Y10 to Y17, Y20 to Y27. The output point in the module ① called by host are Y30 to Y37 and Y40 to Y43, and the output points in the module ③ called by host are Y50 to Y57 and Y60 to Y67.
98 98  
99 -[[image:image-20220704141840-11.jpeg]]
104 +[[image:image-20220704141840-11.jpeg||class="img-thumbnail"]]
100 100  
101 101  As shown in the example above, it is the LX3V-3624MT with one LX3V-16EYR and two LX3V-4DA modules. The host has24 output points Y: Y0 to YX7, Y10 to Y17, Y20 to Y27. The output point in the module ③ called by host are Y30 to Y37 and Y40 to Y47.