Changes for page LX5V-2PT2DAI
Last modified by WeconTurkey on 2024/10/16 22:58
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Jim1 +XWiki.Karen - Content
-
... ... @@ -1,13 +1,13 @@ 1 1 = **1. Installation** = 2 2 3 -* Before installation, it must be ensured that the PLC host and the related device of the BD board4 -* Two standard terminal heads are equipped with this B dboard. After connecting the wiring, insert them into its terminal. After confirming that the host, BDboard, wiring, etc. are installed correctly, it can be powered on for use.3 +* Before installation, it must be ensured that the PLC host and the related device of the BD module terminal wiring are powered off reliably. The module shell is inserted into the BD module slot of PLC host, and then locked with two standard screws for fixation. 4 +* Two standard terminal heads are equipped with this BD module. After connecting the wiring, insert them into its terminal. After confirming that the host, BD module, wiring, etc. are installed correctly, it can be powered on for use. 5 5 * **✎Note:** 6 6 ** When DAI current is output, ensure that the external load resistance is less than 500Ω. If the external load resistance is greater than 500Ω, the output current will be lower than normal value. 7 -** Please install the BD board firmly and fix it on PLC. Poor contact may lead to failure.8 -** Tightening torque for fixing BD board or PLC top cover is 0.3N.m to0.6N.m. Please tighten it firmly to avoid malfunction.7 +** Please install the BD module firmly and fix it on PLC. Poor contact may lead to failure. 8 +** Tightening torque for fixing BD module or PLC top cover is 0.3N.m to0.6N.m. Please tighten it firmly to avoid malfunction. 9 9 ** You can only use a LX5V-2PT2DAI-BD on the PLC main unit of LX5 series. 10 -* **Warning: Cut off the power before installing, removing or wiring the BD board to avoid electric shock or product damage.**10 +* **Warning: Cut off the power before installing, removing or wiring the BD module to avoid electric shock or product damage.** 11 11 12 12 = **2. Appearance and terminal** = 13 13 ... ... @@ -124,7 +124,7 @@ 124 124 125 125 **✎Note:** 126 126 127 -* 127 +* \\ 128 128 ** Do not place signal cables near high voltage power cables or in the same trunk line. Otherwise, it may be disturbed or surged. Keep a safe distance between signal cable and power cable, at least 100mm. 129 129 ** Ground the shielding of shielded wire or shielded cable. But the ground point and high voltage line cannot be the same. 130 130 ** Do not connect cables of impermissible size to avoid poor contact or product damage.