Changes for page LX5V-2PT2DAI

Last modified by WeconTurkey on 2024/10/16 22:58

From version 2.1
edited by Jim
on 2022/12/22 11:07
Change comment: There is no comment for this version
To version 3.1
edited by Jim
on 2022/12/22 11:16
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -78,7 +78,7 @@
78 78  When the channel is open, the light is on, and the current is output; When the channel is closed, the light is off, and the current is not output (approaching 0).
79 79  )))
80 80  
81 -= 3. ** Specification** =
81 += 3. ** Specification** =
82 82  
83 83  ~1. General specification: Same as PLC main unit. (Please refer to the accompanying manual of the PLC main unit.)
84 84  
... ... @@ -124,7 +124,7 @@
124 124  
125 125  **✎Note:**
126 126  
127 -*
127 +*
128 128  ** Do not place signal cables near high voltage power cables or in the same trunk line. Otherwise, it may be disturbed or surged. Keep a safe distance between signal cable and power cable, at least 100mm.
129 129  ** Ground the shielding of shielded wire or shielded cable. But the ground point and high voltage line cannot be the same.
130 130  ** Do not connect cables of impermissible size to avoid poor contact or product damage.
... ... @@ -152,3 +152,67 @@
152 152  |AWG16|1.309
153 153  
154 154  [[image:image-20221222110656-4.png]]
155 +
156 +=== **4.2 I/O Mode** ===
157 +
158 +Thermal resistance PT100 input mode
159 +
160 +[[image:image-20221222110832-1.jpeg]]
161 +
162 +Current output mode
163 +
164 +[[image:image-20221222110832-2.png]]
165 +
166 += **5. Description of PLC device** =
167 +
168 +~1. When connected to LX3 series PLC, please refer to LX3 series BD board manual.
169 +
170 +2. When connected to LX5 series PLC, if the firmware version of PLC is lower than 2.051 (excluding 2.051), or BD board is not configured by host computer, it can be controlled by the following system devices:
171 +
172 +3. User can select device through I/O mapping to use the configuration function of new BD board. For details, please refer to "[[6.1 Parameter configuration>>path:#_6.1 参数配置]]".
173 +
174 +**Device allocation**
175 +
176 +|**PLC model**|**BD Model**|**Device**|(% colspan="2" %)**Description**|**Devices**|**Description**
177 +|(% rowspan="4" %)LX5V|(% rowspan="4" %)2PT2DAI|SM2010|CH1 thermal resistance input channel open flag|(% rowspan="4" %)(((
178 +OFF: Open
179 +
180 +ON: Close
181 +)))|SD2010|(((
182 +The temperature of CH1 at 0.1°C
183 +
184 +(-100℃ to 600℃: -1000 to 6000)
185 +)))
186 +|SM2011|CH2 thermal resistance input channel open flag|SD2011|(((
187 +The temperature of CH2 at 0.1°C
188 +
189 +(-100℃ to 600℃: -1000 to 6000)
190 +)))
191 +|SM2012|CH3 current output channel open flag|SD2012|(((
192 +CH3 digital value
193 +
194 +0 to 2000: 4mA to 20mA
195 +)))
196 +|SM2013|CH4 current output channel open flag|SD2013|(((
197 +CH4 digital value
198 +
199 +0 to 2000: 4mA to 20mA
200 +)))
201 +
202 += **6. Instructions for use** =
203 +
204 +=== **6.1 Parameter configuration** ===
205 +
206 +① Open the host computer software and create a new project, in “Project Manager” → “Extended Function” , double-click "BD Board Configuration" **^^Note^^**to enter “BD settings” interface;
207 +
208 +② Configure the currently connected PLC (take the LX5V-2416 model as an example) and BD board model on the BD board configuration interface: Select “LX5V-2PTWDAI" in the device bar on the right side of the BD board configuration interface and double-click to add it to the corresponding slot position of PLC (slot number 1 or 2, the software will select slot 1 by default, and right-click to move down to slot 2);
209 +
210 +③ After adding the BD board to the slot, double-click or right-click to select configuration parameters to enter LX5V-2PT2DAI-BD configuration parameters interface, as shown in the following figure. Configure related parameters on this interface.
211 +
212 +[[image:image-20221222111514-3.png]]
213 +
214 +**Note: This function is only supported in the following versions of host computer, slave computer and BD board:**
215 +
216 +(1) Supported host computer software versions: Wecon PLC Editor2 2.1.204 and above, as shown in the following figure:
217 +
218 +[[image:image-20221222111611-4.png]]
image-20221222110832-1.jpeg
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +9.3 KB
Content
image-20221222110832-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +43.3 KB
Content
image-20221222111514-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +966.5 KB
Content
image-20221222111611-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +966.5 KB
Content