Changes for page LX5V-2PT2DAI
Last modified by WeconTurkey on 2024/10/16 22:58
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -124,7 +124,7 @@ 124 124 125 125 **✎Note:** 126 126 127 -* 127 +* 128 128 ** Do not place signal cables near high voltage power cables or in the same trunk line. Otherwise, it may be disturbed or surged. Keep a safe distance between signal cable and power cable, at least 100mm. 129 129 ** Ground the shielding of shielded wire or shielded cable. But the ground point and high voltage line cannot be the same. 130 130 ** Do not connect cables of impermissible size to avoid poor contact or product damage. ... ... @@ -249,9 +249,9 @@ 249 249 * The input temperature of control channel is 0℃, the value of acquisition channel is 30 (unit: 0.1℃), and the actual channel value should be 0 (unit: 0.1℃). 250 250 * The input temperature of control channel is 500℃, the value of acquisition channel is 5200 (unit: 0.1℃), and the actual channel value should be 5000 (unit: 0.1℃). 251 251 252 -Suppose the gain is a, and the offset is b, then[[image:image-20221222112833-6.png]] [[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml6012\wps9.png]][[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml6012\wps7.png]][[image:file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml6012\wps9.png]]252 +Suppose the gain is a, and the offset is b, then[[image:image-20221222112833-6.png]] 253 253 254 -Solve and get[[image: file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml6012\wps8.png]][[image:image-20221222112858-7.png]] The calibration can be completed by setting the corresponding gain offset to the current channel.254 +Solve and get[[image:image-20221222112858-7.png]] The calibration can be completed by setting the corresponding gain offset to the current channel. 255 255 256 256 **✎Note**: **Using gain and offset calibration can only reduce the linear error. Since the PT100 resistance and temperature curve are nonlinear, there is still a certain error in partial temperature after the calibration is successful.** 257 257 ... ... @@ -279,9 +279,9 @@ 279 279 * When the channel input digital value is 0, the multimeter measures the output current of BD board channel to be 5mA (corresponding digital value is 125). 280 280 * When the channel input digital value is 2000, the multimeter measures the output current of BD board channel to be 5mA (corresponding digital value is 1875). 281 281 282 -Suppose the gain is a, and the offset is b, then[[image: file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml6012\wps10.png]][[image:image-20221222113055-9.png]]282 +Suppose the gain is a, and the offset is b, then[[image:image-20221222113055-9.png]] 283 283 284 -Solve and get[[image: file:///C:\Users\ANNAXU~~1\AppData\Local\Temp\ksohtml6012\wps11.png]][[image:image-20221222113102-10.png]]The calibration can be completed by setting the corresponding gain offset to the current channel.284 +Solve and get[[image:image-20221222113102-10.png]]The calibration can be completed by setting the corresponding gain offset to the current channel. 285 285 286 286 4. Set I/O mapping. The channels are mapped to R device according to the current number of BD board channels by default. As shown in the following figure, BD board CH1 to CH4 is mapped to device R0 to R3. 287 287 ... ... @@ -334,3 +334,72 @@ 334 334 2: Channel value exceeds the range 335 335 ))) 336 336 |0x2184|×|R|Channel 2 error code|0|0 to 1|0: No error; 1: Channel value exceeds the range 337 + 338 +② DAI buffer memory (BFM): used for BD board status monitoring. 339 + 340 +(% class="table-bordered" %) 341 +|((( 342 +**BFM** 343 + 344 +**Address** 345 +)))|**Power-off hold**|**Read/write**|**Memory name**|**Default**|**Range**|**Description** 346 +|0x2200|×|R/W|Channel 3 channel enable|1|0 to 1|0: Channel closed; 1: Channel open 347 +|0x2201|×|R/W|Channel 3 channel mode selection|1|1|1: Current output mode (4mA to 20mA) 348 +|0x2203|×|R/W|Output status after channel 3 stops|0|0 to 2|((( 349 +0: Output cleared; 1: Output held 350 + 351 +2: Output preset value 352 +))) 353 +|0x2204|×|R/W|Channel 3 output preset value|0|-32768 to 32767| 354 +|0x2280|×|R|Channel 3 channel value|0|0 to 2000|Only supported in channel mapping device setting 355 +|0x2282|×|R|Channel 3 status information|1|0 to 2|((( 356 +0: Channel closed 1: Channel opened 357 + 358 +2: Channel value exceeds the range 359 +))) 360 +|0x2284|×|R|Channel 3 error code|0|0 to 1|0: No error; 1: Channel value exceeds the range 361 +|0x2300|×|R/W|Channel 4 channel enable|1|0 to 1|0: Channel closed; 1: Channel open 362 +|0x2301|×|R/W|Channel 4 channel mode selection|1|1|1: Current output mode (4mA to 20mA) 363 +|0x2303|×|R/W|Output status after channel 4 stops|0|0 to 2|((( 364 +0: Output cleared; 1: Output held 365 + 366 +2: Output preset value 367 +))) 368 +|0x2304|×|R/W|Channel 4 output preset value|0|-32768 to 32767| 369 +|0x2380|×|R|Channel 4 channel value|0|0 to 2000|Only supported in channel mapping device setting 370 +|0x2382|×|R|Channel 4 status information|1|0 to 2|((( 371 +0: Channel closed 1: Channel opened 372 + 373 +2: Channel value exceeds the range 374 +))) 375 +|0x2384|×|R|Channel 4 error code|0|0 to 1|0: No error; 1: Channel value exceeds the range 376 + 377 +③ Universal buffer memory (BFM): used to diagnose the communication status of the currently connected BD board. 378 + 379 +(% class="table-bordered" %) 380 +|((( 381 +**BFM** 382 + 383 +**Address** 384 +)))|**Power-off hold**|((( 385 +**Read/write** 386 + 387 +**Function** 388 +)))|**Memory name**|**Default**|**Range**|**Description** 389 +|0x200|×|R|Current maximum package length|0|0 to 0xFFFF|The maximum length of the currently sent package 390 +|0x202|×|R|Number of retransmissions|0|0 to 0xFFFF|Number of retransmissions 391 +|0x204|×|R|Number of retransmissions of subpackages|0|0 to 0xFFFF|Number of retransmissions of subpackages 392 +|0x206|×|R|Received times of sync frame|0|0 to 0xFFFF|Received times of sync frame 393 +|0x208|×|R|Sent times of sync frame|0|0 to 0xFFFF|Sent times of sync frame 394 +|0x20A|×|R|Control the number of transmissions|0|0 to 0xFFFF|Control the number of transmissions 395 +|0x20C|×|R|Control the number of receptions|0|0 to 0xFFFF|Control the number of receptions 396 +|0x20E|×|R|Number of subscriptions sent|0|0 to 0xFFFF|Number of subscriptions sent 397 +|0x210|×|R|Number of subscriptions received|0|0 to 0xFFFF|Number of subscriptions received 398 +|0x212|√|R/W|Latest error code|0|Only 0 can be written.|Protocol internal error code, write 0 to clear 399 +|0x214|×|R|Number of bytes sent|0|0 to 0xFFFFFFFF|Number of bytes sent 400 +|0x218|×|R|Number of valid bytes sent|0|0 to 0xFFFFFFFF|Number of valid bytes sent 401 +|0x21C|×|R|Number of bytes received|0|0 to 0xFFFFFFFF|Number of bytes received 402 +|0x220|×|R|Number of valid bytes received|0|0 to 0xFFFFFFFF|Number of valid bytes received 403 +|0x224|×|R|Communication time (unit s)|0|0 to 0xFFFFFFFF|Normal communication time since the BD board is powered on 404 + 405 +