Changes for page LX5V-2RS485-BD

Last modified by Jim on 2023/05/29 16:00

From version 11.1
edited by Stone Wu
on 2022/09/13 16:00
Change comment: There is no comment for this version
To version 7.1
edited by Stone Wu
on 2022/09/13 15:57
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -205,86 +205,86 @@
205 205  
206 206  **Error code**
207 207  
208 -|=(% scope="row" style="width: 99px;" %)**Error code**|=(% style="width: 976px;" %)**Content**
209 -|=(% style="width: 99px;" %)4085H|(% style="width:976px" %)(S), (M), (D) and (N) read address out of range of the device.
210 -|=(% style="width: 99px;" %)4084H|(% style="width:976px" %)Parameter value is out of the specified range.
208 +|=(% scope="row" style="width: 107px;" %)**Error code**|=(% style="width: 968px;" %)**Content**
209 +|=(% style="width: 107px;" %)4085H|(% style="width:968px" %)(S), (M), (D) and (N) read address out of range of the device.
210 +|=(% style="width: 107px;" %)4084H|(% style="width:968px" %)Parameter value is out of the specified range.
211 211  |=(% colspan="2" %)**COM3**
212 -|=(% style="width: 99px;" %)3280H|(% style="width:976px" %)COM3 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
213 -|=(% style="width: 99px;" %)3281H|(% style="width:976px" %)COM3 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
214 -|=(% style="width: 99px;" %)3282H|(% style="width:976px" %)COM3 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
215 -|=(% style="width: 99px;" %)3283H|(% style="width:976px" %)COM3 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
216 -|=(% style="width: 99px;" %)3284H|(% style="width:976px" %)COM3 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
217 -|=(% style="width: 99px;" %)3285H|(% style="width:976px" %)COM3 send buffer overflow. If this error appears, please contact your technician.
218 -|=(% style="width: 99px;" %)3286H|(% style="width:976px" %)COM3 function code error. Check whether the set function code is supported by PLC.
219 -|=(% style="width: 99px;" %)3287H|(% style="width:976px" %)COM3 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
220 -|=(% style="width: 99px;" %)3288H|(% style="width:976px" %)COM3 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
221 -|=(% style="width: 99px;" %)3289H|(% style="width:976px" %)COM3 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
222 -|=(% style="width: 99px;" %)328AH|(% style="width:976px" %)COM3 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
223 -|=(% style="width: 99px;" %)328BH|(% style="width:976px" %)COM3 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
224 -|=(% style="width: 99px;" %)328CH|(% style="width:976px" %)COM3 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed (Please refer to Modbus exception 04).
225 -|=(% style="width: 99px;" %)328DH|(% style="width:976px" %)COM3 slave confirmation. Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
226 -|=(% style="width: 99px;" %)328EH|(% style="width:976px" %)COM 3 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
227 -|=(% style="width: 99px;" %)328FH|(% style="width:976px" %)COM3 sending timed out. If this error appears, please contact your technician.
228 -|=(% style="width: 99px;" %)32A0H|(% style="width:976px" %)COM3 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
229 -|=(% style="width: 99px;" %)32A1H|(% style="width:976px" %)COM3 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
212 +|=(% style="width: 107px;" %)3280H|(% style="width:968px" %)COM3 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
213 +|=(% style="width: 107px;" %)3281H|(% style="width:968px" %)COM3 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
214 +|=(% style="width: 107px;" %)3282H|(% style="width:968px" %)COM3 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
215 +|=(% style="width: 107px;" %)3283H|(% style="width:968px" %)COM3 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
216 +|=(% style="width: 107px;" %)3284H|(% style="width:968px" %)COM3 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
217 +|=(% style="width: 107px;" %)3285H|(% style="width:968px" %)COM3 send buffer overflow. If this error appears, please contact your technician.
218 +|=(% style="width: 107px;" %)3286H|(% style="width:968px" %)COM3 function code error. Check whether the set function code is supported by PLC.
219 +|=(% style="width: 107px;" %)3287H|(% style="width:968px" %)COM3 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
220 +|=(% style="width: 107px;" %)3288H|(% style="width:968px" %)COM3 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
221 +|=(% style="width: 107px;" %)3289H|(% style="width:968px" %)COM3 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
222 +|=(% style="width: 107px;" %)328AH|(% style="width:968px" %)COM3 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
223 +|=(% style="width: 107px;" %)328BH|(% style="width:968px" %)COM3 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
224 +|=(% style="width: 107px;" %)328CH|(% style="width:968px" %)COM3 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed (Please refer to Modbus exception 04).
225 +|=(% style="width: 107px;" %)328DH|(% style="width:968px" %)COM3 slave confirmation. Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
226 +|=(% style="width: 107px;" %)328EH|(% style="width:968px" %)COM 3 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
227 +|=(% style="width: 107px;" %)328FH|(% style="width:968px" %)COM3 sending timed out. If this error appears, please contact your technician.
228 +|=(% style="width: 107px;" %)32A0H|(% style="width:968px" %)COM3 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
229 +|=(% style="width: 107px;" %)32A1H|(% style="width:968px" %)COM3 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
230 230  |=(% colspan="2" %)**COM4**
231 -|=(% style="width: 99px;" %)3380H|(% style="width:976px" %)COM4 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
232 -|=(% style="width: 99px;" %)3381H|(% style="width:976px" %)COM4 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
233 -|=(% style="width: 99px;" %)3382H|(% style="width:976px" %)COM4 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
234 -|=(% style="width: 99px;" %)3383H|(% style="width:976px" %)COM4 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
235 -|=(% style="width: 99px;" %)3384H|(% style="width:976px" %)COM4 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
236 -|=(% style="width: 99px;" %)3385H|(% style="width:976px" %)COM4 send buffer overflow. If this error appears, please contact your technician.
237 -|=(% style="width: 99px;" %)3386H|(% style="width:976px" %)COM4 function code error. Check whether the set function code is supported by PLC.
238 -|=(% style="width: 99px;" %)3387H|(% style="width:976px" %)COM4 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
239 -|=(% style="width: 99px;" %)3388H|(% style="width:976px" %)COM4 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
240 -|=(% style="width: 99px;" %)3389H|(% style="width:976px" %)COM4 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
241 -|=(% style="width: 99px;" %)338AH|(% style="width:976px" %)COM4 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
242 -|=(% style="width: 99px;" %)338BH|(% style="width:976px" %)COM4 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
243 -|=(% style="width: 99px;" %)338CH|(% style="width:976px" %)COM4 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed. (Please refer to Modbus exception 04).
244 -|=(% style="width: 99px;" %)338DH|(% style="width:976px" %)COM4 slave confirmation Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
245 -|=(% style="width: 99px;" %)338EH|(% style="width:976px" %)COM4 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
246 -|=(% style="width: 99px;" %)338FH|(% style="width:976px" %)COM4 send timed out. If this error appears, please contact your technician.
247 -|=(% style="width: 99px;" %)33A0H|(% style="width:976px" %)COM4 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
248 -|=(% style="width: 99px;" %)33A1H|(% style="width:976px" %)COM4 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
231 +|=(% style="width: 107px;" %)3380H|(% style="width:968px" %)COM4 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
232 +|=(% style="width: 107px;" %)3381H|(% style="width:968px" %)COM4 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
233 +|=(% style="width: 107px;" %)3382H|(% style="width:968px" %)COM4 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
234 +|=(% style="width: 107px;" %)3383H|(% style="width:968px" %)COM4 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
235 +|=(% style="width: 107px;" %)3384H|(% style="width:968px" %)COM4 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
236 +|=(% style="width: 107px;" %)3385H|(% style="width:968px" %)COM4 send buffer overflow. If this error appears, please contact your technician.
237 +|=(% style="width: 107px;" %)3386H|(% style="width:968px" %)COM4 function code error. Check whether the set function code is supported by PLC.
238 +|=(% style="width: 107px;" %)3387H|(% style="width:968px" %)COM4 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
239 +|=(% style="width: 107px;" %)3388H|(% style="width:968px" %)COM4 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
240 +|=(% style="width: 107px;" %)3389H|(% style="width:968px" %)COM4 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
241 +|=(% style="width: 107px;" %)338AH|(% style="width:968px" %)COM4 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
242 +|=(% style="width: 107px;" %)338BH|(% style="width:968px" %)COM4 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
243 +|=(% style="width: 107px;" %)338CH|(% style="width:968px" %)COM4 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed. (Please refer to Modbus exception 04).
244 +|=(% style="width: 107px;" %)338DH|(% style="width:968px" %)COM4 slave confirmation Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
245 +|=(% style="width: 107px;" %)338EH|(% style="width:968px" %)COM4 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
246 +|=(% style="width: 107px;" %)338FH|(% style="width:968px" %)COM4 send timed out. If this error appears, please contact your technician.
247 +|=(% style="width: 107px;" %)33A0H|(% style="width:968px" %)COM4 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
248 +|=(% style="width: 107px;" %)33A1H|(% style="width:968px" %)COM4 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
249 249  
250 250  |=(% colspan="2" scope="row" %)**COM5**
251 -|=(% style="width: 99px;" %)3480H|(% style="width:976px" %)COM5 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
252 -|=(% style="width: 99px;" %)3481H|(% style="width:976px" %)COM5 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
253 -|=(% style="width: 99px;" %)3482H|(% style="width:976px" %)COM5 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
254 -|=(% style="width: 99px;" %)3483H|(% style="width:976px" %)COM5 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
255 -|=(% style="width: 99px;" %)3484H|(% style="width:976px" %)COM5 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
256 -|=(% style="width: 99px;" %)3485H|(% style="width:976px" %)COM5 send buffer overflow. If this error appears, please contact your technician.
257 -|=(% style="width: 99px;" %)3486H|(% style="width:976px" %)COM5 function code error. Check whether the set function code is supported by PLC.
258 -|=(% style="width: 99px;" %)3487H|(% style="width:976px" %)COM5 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
259 -|=(% style="width: 99px;" %)3488H|(% style="width:976px" %)COM5 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
260 -|=(% style="width: 99px;" %)3489H|(% style="width:976px" %)COM5 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
261 -|=(% style="width: 99px;" %)348AH|(% style="width:976px" %)COM5 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
262 -|=(% style="width: 99px;" %)348BH|(% style="width:976px" %)COM5 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
263 -|=(% style="width: 99px;" %)348CH|(% style="width:976px" %)COM5 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed. (Please refer to Modbus exception 04).
264 -|=(% style="width: 99px;" %)348DH|(% style="width:976px" %)COM5 slave station confirmation Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
265 -|=(% style="width: 99px;" %)348EH|(% style="width:976px" %)COM5 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
266 -|=(% style="width: 99px;" %)348FH|(% style="width:976px" %)COM5 send timed out. If this error appears, please contact your technician.
267 -|=(% style="width: 99px;" %)34A0H|(% style="width:976px" %)COM5 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
268 -|=(% style="width: 99px;" %)34A1H|(% style="width:976px" %)COM5 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
251 +|=(% style="width: 139px;" %)3480H|(% style="width:936px" %)COM5 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
252 +|=(% style="width: 139px;" %)3481H|(% style="width:936px" %)COM5 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
253 +|=(% style="width: 139px;" %)3482H|(% style="width:936px" %)COM5 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
254 +|=(% style="width: 139px;" %)3483H|(% style="width:936px" %)COM5 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
255 +|=(% style="width: 139px;" %)3484H|(% style="width:936px" %)COM5 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
256 +|=(% style="width: 139px;" %)3485H|(% style="width:936px" %)COM5 send buffer overflow. If this error appears, please contact your technician.
257 +|=(% style="width: 139px;" %)3486H|(% style="width:936px" %)COM5 function code error. Check whether the set function code is supported by PLC.
258 +|=(% style="width: 139px;" %)3487H|(% style="width:936px" %)COM5 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
259 +|=(% style="width: 139px;" %)3488H|(% style="width:936px" %)COM5 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
260 +|=(% style="width: 139px;" %)3489H|(% style="width:936px" %)COM5 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
261 +|=(% style="width: 139px;" %)348AH|(% style="width:936px" %)COM5 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
262 +|=(% style="width: 139px;" %)348BH|(% style="width:936px" %)COM5 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
263 +|=(% style="width: 139px;" %)348CH|(% style="width:936px" %)COM5 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed. (Please refer to Modbus exception 04).
264 +|=(% style="width: 139px;" %)348DH|(% style="width:936px" %)COM5 slave station confirmation Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
265 +|=(% style="width: 139px;" %)348EH|(% style="width:936px" %)COM5 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
266 +|=(% style="width: 139px;" %)348FH|(% style="width:936px" %)COM5 send timed out. If this error appears, please contact your technician.
267 +|=(% style="width: 139px;" %)34A0H|(% style="width:936px" %)COM5 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
268 +|=(% style="width: 139px;" %)34A1H|(% style="width:936px" %)COM5 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
269 269  |=(% colspan="2" %)COM6
270 -|=(% style="width: 99px;" %)3580H|(% style="width:976px" %)COM6 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
271 -|=(% style="width: 99px;" %)3581H|(% style="width:976px" %)COM6 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
272 -|=(% style="width: 99px;" %)3582H|(% style="width:976px" %)COM6 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
273 -|=(% style="width: 99px;" %)3583H|(% style="width:976px" %)COM6 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
274 -|=(% style="width: 99px;" %)3584H|(% style="width:976px" %)COM6 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
275 -|=(% style="width: 99px;" %)3585H|(% style="width:976px" %)COM6 send buffer overflow. If this error appears, please contact your technician.
276 -|=(% style="width: 99px;" %)3586H|(% style="width:976px" %)COM6 function code error. Check whether the set function code is supported by PLC.
277 -|=(% style="width: 99px;" %)3587H|(% style="width:976px" %)COM6 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
278 -|=(% style="width: 99px;" %)3588H|(% style="width:976px" %)COM6 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
279 -|=(% style="width: 99px;" %)3589H|(% style="width:976px" %)COM6 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
280 -|=(% style="width: 99px;" %)358AH|(% style="width:976px" %)COM6 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
281 -|=(% style="width: 99px;" %)358BH|(% style="width:976px" %)COM6 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
282 -|=(% style="width: 99px;" %)358CH|(% style="width:976px" %)COM6 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed. (Please refer to Modbus exception 04).
283 -|=(% style="width: 99px;" %)358DH|(% style="width:976px" %)COM6 slave station acknowledges. Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
284 -|=(% style="width: 99px;" %)358EH|(% style="width:976px" %)COM6 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
285 -|=(% style="width: 99px;" %)358FH|(% style="width:976px" %)COM6 send timed out. If this error appears, please contact your technician.
286 -|=(% style="width: 99px;" %)35A0H|(% style="width:976px" %)COM6 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
287 -|=(% style="width: 99px;" %)35A1H|(% style="width:976px" %)COM6 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
270 +|=(% style="width: 139px;" %)3580H|(% style="width:936px" %)COM6 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
271 +|=(% style="width: 139px;" %)3581H|(% style="width:936px" %)COM6 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
272 +|=(% style="width: 139px;" %)3582H|(% style="width:936px" %)COM6 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
273 +|=(% style="width: 139px;" %)3583H|(% style="width:936px" %)COM6 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
274 +|=(% style="width: 139px;" %)3584H|(% style="width:936px" %)COM6 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
275 +|=(% style="width: 139px;" %)3585H|(% style="width:936px" %)COM6 send buffer overflow. If this error appears, please contact your technician.
276 +|=(% style="width: 139px;" %)3586H|(% style="width:936px" %)COM6 function code error. Check whether the set function code is supported by PLC.
277 +|=(% style="width: 139px;" %)3587H|(% style="width:936px" %)COM6 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
278 +|=(% style="width: 139px;" %)3588H|(% style="width:936px" %)COM6 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
279 +|=(% style="width: 139px;" %)3589H|(% style="width:936px" %)COM6 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
280 +|=(% style="width: 139px;" %)358AH|(% style="width:936px" %)COM6 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
281 +|=(% style="width: 139px;" %)358BH|(% style="width:936px" %)COM6 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
282 +|=(% style="width: 139px;" %)358CH|(% style="width:936px" %)COM6 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed. (Please refer to Modbus exception 04).
283 +|=(% style="width: 139px;" %)358DH|(% style="width:936px" %)COM6 slave station acknowledges. Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
284 +|=(% style="width: 139px;" %)358EH|(% style="width:936px" %)COM6 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
285 +|=(% style="width: 139px;" %)358FH|(% style="width:936px" %)COM6 send timed out. If this error appears, please contact your technician.
286 +|=(% style="width: 139px;" %)35A0H|(% style="width:936px" %)COM6 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
287 +|=(% style="width: 139px;" %)35A1H|(% style="width:936px" %)COM6 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
288 288  
289 289  **6 Address mapping**
290 290  
... ... @@ -291,27 +291,27 @@
291 291  When the BD board configures the serial port protocol as Modbus slave station protocol, the address mapping relationship accessed by the master station is as follows:
292 292  
293 293  |=(% colspan="5" %)**Word address**
294 -|(% style="width:213px" %)**Address type**|(% style="width:212px" %)**Occupation**|(% style="width:226px" %)**Address range**|(% style="width:173px" %)**Decimal address**|(% style="width:252px" %)**Total reserved address size**
295 -|(% style="width:213px" %)T0 to T511|(% style="width:212px" %)512 WORD|(% style="width:226px" %)0x0000 to 0x01ff|(% style="width:173px" %)0|(% style="width:252px" %)1536
296 -|(% style="width:213px" %)C0 to C255|(% style="width:212px" %)256 WORD|(% style="width:226px" %)0x0600 to 0x06ff|(% style="width:173px" %)1536|(% style="width:252px" %)1024
297 -|(% style="width:213px" %)LC0 to LC255|(% style="width:212px" %)512 WORD|(% style="width:226px" %)0x0A000 to 0x0BFF|(% style="width:173px" %)2560|(% style="width:252px" %)1024
298 -|(% style="width:213px" %)HSC0 to HSC15|(% style="width:212px" %)128 WORD|(% style="width:226px" %)0x0E00 to 0x0E1F|(% style="width:173px" %)3584|(% style="width:252px" %)512
299 -|(% style="width:213px" %)D0 to D7999|(% style="width:212px" %)8000 WORD|(% style="width:226px" %)0x1000 to 0x2F3F|(% style="width:173px" %)4096|(% style="width:252px" %)16384
300 -|(% style="width:213px" %)SD0 to SD4095|(% style="width:212px" %)4096 WORD|(% style="width:226px" %)0x5000 to 0x5FFF|(% style="width:173px" %)20480|(% style="width:252px" %)12288
301 -|(% style="width:213px" %)R0 to R30000|(% style="width:212px" %)30000 WORD|(% style="width:226px" %)0x8000 to 0xF52F|(% style="width:173px" %)32768|(% style="width:252px" %)30000
294 +|**Address type**|(% style="width:172px" %)**Occupation**|(% style="width:239px" %)**Address range**|(% style="width:208px" %)**Decimal address**|(% style="width:271px" %)**Total reserved address size**
295 +|T0 to T511|(% style="width:172px" %)512 WORD|(% style="width:239px" %)0x0000 to 0x01ff|(% style="width:208px" %)0|(% style="width:271px" %)1536
296 +|C0 to C255|(% style="width:172px" %)256 WORD|(% style="width:239px" %)0x0600 to 0x06ff|(% style="width:208px" %)1536|(% style="width:271px" %)1024
297 +|LC0 to LC255|(% style="width:172px" %)512 WORD|(% style="width:239px" %)0x0A000 to 0x0BFF|(% style="width:208px" %)2560|(% style="width:271px" %)1024
298 +|HSC0 to HSC15|(% style="width:172px" %)128 WORD|(% style="width:239px" %)0x0E00 to 0x0E1F|(% style="width:208px" %)3584|(% style="width:271px" %)512
299 +|D0 to D7999|(% style="width:172px" %)8000 WORD|(% style="width:239px" %)0x1000 to 0x2F3F|(% style="width:208px" %)4096|(% style="width:271px" %)16384
300 +|SD0 to SD4095|(% style="width:172px" %)4096 WORD|(% style="width:239px" %)0x5000 to 0x5FFF|(% style="width:208px" %)20480|(% style="width:271px" %)12288
301 +|R0 to R30000|(% style="width:172px" %)30000 WORD|(% style="width:239px" %)0x8000 to 0xF52F|(% style="width:208px" %)32768|(% style="width:271px" %)30000
302 302  
303 303  |=(% colspan="5" %)**Bit address**
304 -|(% style="width:212px" %)**Address type**|(% style="width:214px" %)**Occupation**|(% style="width:229px" %)**Address range**|(% style="width:170px" %)**Decimal address**|(% style="width:251px" %)**Total reserved address size**
305 -|(% style="width:212px" %)T0 to T511|(% style="width:214px" %)512 bits|(% style="width:229px" %)0x0000 to 0x01ff|(% style="width:170px" %)0|(% style="width:251px" %)1536
306 -|(% style="width:212px" %)C0 to C255|(% style="width:214px" %)256 bits|(% style="width:229px" %)0x0600 to 0x06ff|(% style="width:170px" %)1536|(% style="width:251px" %)1024
307 -|(% style="width:212px" %)LC0 to LC255|(% style="width:214px" %)256 bits|(% style="width:229px" %)0x0A00 to 0x0AFF|(% style="width:170px" %)2560|(% style="width:251px" %)1024
308 -|(% style="width:212px" %)HSC0 to HSC15|(% style="width:214px" %)64 bits|(% style="width:229px" %)0x0E00 to 0x0E0F|(% style="width:170px" %)3584|(% style="width:251px" %)512
309 -|(% style="width:212px" %)M0 to M8000|(% style="width:214px" %)8192 bits|(% style="width:229px" %)0x1000 to 0x2F3F|(% style="width:170px" %)4096|(% style="width:251px" %)16384
310 -|(% style="width:212px" %)SM0 to SM4095|(% style="width:214px" %)4096 bits|(% style="width:229px" %)0x5000 to 0x5FFF|(% style="width:170px" %)20480|(% style="width:251px" %)12288
311 -|(% style="width:212px" %)Reserved|(% style="width:214px" %) |(% style="width:229px" %)0x8000 to 0xBFFF|(% style="width:170px" %) |(% style="width:251px" %)16383
312 -|(% style="width:212px" %)S0 to S4095|(% style="width:214px" %)4096 bits|(% style="width:229px" %)0xC000 to 0xCFFF|(% style="width:170px" %)49152|(% style="width:251px" %)8192
313 -|(% style="width:212px" %)X0 to X1023|(% style="width:214px" %)1024 bits|(% style="width:229px" %)0xE000 to 0xE3FF|(% style="width:170px" %)57344|(% style="width:251px" %)4096
314 -|(% style="width:212px" %)Y0 to Y1023|(% style="width:214px" %)1024 bits|(% style="width:229px" %)0xF000 to 0xF3FF|(% style="width:170px" %)61440|(% style="width:251px" %)4096
304 +|**Address type**|(% style="width:168px" %)**Occupation**|(% style="width:238px" %)**Address range**|(% style="width:210px" %)**Decimal address**|(% style="width:270px" %)**Total reserved address size**
305 +|T0 to T511|(% style="width:168px" %)512 bits|(% style="width:238px" %)0x0000 to 0x01ff|(% style="width:210px" %)0|(% style="width:270px" %)1536
306 +|C0 to C255|(% style="width:168px" %)256 bits|(% style="width:238px" %)0x0600 to 0x06ff|(% style="width:210px" %)1536|(% style="width:270px" %)1024
307 +|LC0 to LC255|(% style="width:168px" %)256 bits|(% style="width:238px" %)0x0A00 to 0x0AFF|(% style="width:210px" %)2560|(% style="width:270px" %)1024
308 +|HSC0 to HSC15|(% style="width:168px" %)64 bits|(% style="width:238px" %)0x0E00 to 0x0E0F|(% style="width:210px" %)3584|(% style="width:270px" %)512
309 +|M0 to M8000|(% style="width:168px" %)8192 bits|(% style="width:238px" %)0x1000 to 0x2F3F|(% style="width:210px" %)4096|(% style="width:270px" %)16384
310 +|SM0 to SM4095|(% style="width:168px" %)4096 bits|(% style="width:238px" %)0x5000 to 0x5FFF|(% style="width:210px" %)20480|(% style="width:270px" %)12288
311 +|Reserved|(% style="width:168px" %) |(% style="width:238px" %)0x8000 to 0xBFFF|(% style="width:210px" %) |(% style="width:270px" %)16383
312 +|S0 to S4095|(% style="width:168px" %)4096 bits|(% style="width:238px" %)0xC000 to 0xCFFF|(% style="width:210px" %)49152|(% style="width:270px" %)8192
313 +|X0 to X1023|(% style="width:168px" %)1024 bits|(% style="width:238px" %)0xE000 to 0xE3FF|(% style="width:210px" %)57344|(% style="width:270px" %)4096
314 +|Y0 to Y1023|(% style="width:168px" %)1024 bits|(% style="width:238px" %)0xF000 to 0xF3FF|(% style="width:210px" %)61440|(% style="width:270px" %)4096
315 315  
316 316  When using the Modbus master station to access the slave station, the RS2 instruction specifies the following address:
317 317  
... ... @@ -333,31 +333,31 @@
333 333  
334 334  **BD1:**
335 335  
336 -|=(% scope="row" style="width: 111px;" %)**SD label**|=(% style="width: 317px;" %)**Content**|=(% style="width: 132px;" %)**SD label**|=(% style="width: 516px;" %)**Content**
337 -|=(% style="width: 111px;" %)SM2000|(% style="width:317px" %)COM3 sending control on|(% style="width:132px" %)SD2000|(% style="width:516px" %)Display 0x1062 after 485BD is recognized after power-on.
338 -|=(% style="width: 111px;" %)SM2001|(% style="width:317px" %)COM3 send control/send prompt|(% style="width:132px" %)SD2001|(% style="width:516px" %)Display 485BD version information after 485BD is recognized after power-on.
339 -|=(% style="width: 111px;" %)SM 2002|(% style="width:317px" %)COM3 reception control on|(% style="width:132px" %)SD 2002|(% style="width:516px" %)BD1 last error
340 -|=(% style="width: 111px;" %)SM 2003|(% style="width:317px" %)COM3 accept control/receive prompt|(% style="width:132px" %)SD 2003|(% style="width:516px" %)BD1 current error
341 -|=(% style="width: 111px;" %)SM2004|(% style="width:317px" %)COM3 communication complete flag|(% style="width:132px" %)SD2004|(% style="width:516px" %)BD1 error times
342 -|=(% style="width: 111px;" %)SM 2005|(% style="width:317px" %)COM4 sending control on|(% style="width:132px" %)SD 2005|(% style="width:516px" %)BD1 error communication port.
343 -|=(% style="width: 111px;" %)SM 2006|(% style="width:317px" %)COM4 send control/send prompt|(% style="width:132px" %)SD2006|(% style="width:516px" %)BD1 communication timeout (1ms).
344 -|=(% style="width: 111px;" %)SM 2007|(% style="width:317px" %)COM4 reception control on|(% style="width:132px" %) |(% style="width:516px" %)
345 -|=(% style="width: 111px;" %)SM2008|(% style="width:317px" %)COM4 accept control/receive prompt|(% style="width:132px" %) |(% style="width:516px" %)
346 -|=(% style="width: 111px;" %)SM2009|(% style="width:317px" %)COM4 communication complete flag|(% style="width:132px" %) |(% style="width:516px" %)
336 +|=(% scope="row" style="width: 111px;" %)**SD label**|=(% style="width: 291px;" %)**Content**|=(% style="width: 115px;" %)**SD label**|=(% style="width: 559px;" %)**Content**
337 +|=(% style="width: 111px;" %)SM2000|(% style="width:291px" %)COM3 sending control on|(% style="width:115px" %)SD2000|(% style="width:559px" %)Display 0x1062 after 485BD is recognized after power-on.
338 +|=(% style="width: 111px;" %)SM2001|(% style="width:291px" %)COM3 send control/send prompt|(% style="width:115px" %)SD2001|(% style="width:559px" %)Display 485BD version information after 485BD is recognized after power-on.
339 +|=(% style="width: 111px;" %)SM 2002|(% style="width:291px" %)COM3 reception control on|(% style="width:115px" %)SD 2002|(% style="width:559px" %)BD1 last error
340 +|=(% style="width: 111px;" %)SM 2003|(% style="width:291px" %)COM3 accept control/receive prompt|(% style="width:115px" %)SD 2003|(% style="width:559px" %)BD1 current error
341 +|=(% style="width: 111px;" %)SM2004|(% style="width:291px" %)COM3 communication complete flag|(% style="width:115px" %)SD2004|(% style="width:559px" %)BD1 error times
342 +|=(% style="width: 111px;" %)SM 2005|(% style="width:291px" %)COM4 sending control on|(% style="width:115px" %)SD 2005|(% style="width:559px" %)BD1 error communication port.
343 +|=(% style="width: 111px;" %)SM 2006|(% style="width:291px" %)COM4 send control/send prompt|(% style="width:115px" %)SD2006|(% style="width:559px" %)BD1 communication timeout (1ms).
344 +|=(% style="width: 111px;" %)SM 2007|(% style="width:291px" %)COM4 reception control on|(% style="width:115px" %) |(% style="width:559px" %)
345 +|=(% style="width: 111px;" %)SM2008|(% style="width:291px" %)COM4 accept control/receive prompt|(% style="width:115px" %) |(% style="width:559px" %)
346 +|=(% style="width: 111px;" %)SM2009|(% style="width:291px" %)COM4 communication complete flag|(% style="width:115px" %) |(% style="width:559px" %)
347 347  
348 348  **BD2:**
349 349  
350 -|=(% scope="row" style="width: 113px;" %)**SD label**|=(% style="width: 314px;" %)**Content**|=(% style="width: 131px;" %)**SD label**|=(% style="width: 518px;" %)**Content**
351 -|=(% style="width: 113px;" %)SM2020|(% style="width:314px" %)COM5 sending control on|(% style="width:131px" %)SD2020|(% style="width:518px" %)Display 0x1062 after 485BD is recognized after power-on.
352 -|=(% style="width: 113px;" %)SM2021|(% style="width:314px" %)COM5 send control/send prompt|(% style="width:131px" %)SD2021|(% style="width:518px" %)Display 485BD version information after 485BD is recognized after power-on.
353 -|=(% style="width: 113px;" %)SM 2022|(% style="width:314px" %)COM5 reception control on|(% style="width:131px" %)SD2022|(% style="width:518px" %)BD2 last error
354 -|=(% style="width: 113px;" %)SM2023|(% style="width:314px" %)COM5 accept control/receive prompt|(% style="width:131px" %)SD2023|(% style="width:518px" %)BD2 current error
355 -|=(% style="width: 113px;" %)SM2024|(% style="width:314px" %)COM5 communication complete flag|(% style="width:131px" %)SD2024|(% style="width:518px" %)BD2 error times
356 -|=(% style="width: 113px;" %)SM2025|(% style="width:314px" %)COM6 sending control on|(% style="width:131px" %)SD2025|(% style="width:518px" %)BD2 error communication port.
357 -|=(% style="width: 113px;" %)SM2026|(% style="width:314px" %)COM6 send control/send prompt|(% style="width:131px" %)SD2026|(% style="width:518px" %)BD2 communication timeout (1ms).
358 -|=(% style="width: 113px;" %)SM2027|(% style="width:314px" %)COM6 reception control on|(% style="width:131px" %) |(% style="width:518px" %)
359 -|=(% style="width: 113px;" %)SM2028|(% style="width:314px" %)COM6 accept control/receive prompt|(% style="width:131px" %) |(% style="width:518px" %)
360 -|=(% style="width: 113px;" %)SM2029|(% style="width:314px" %)COM6 communication complete flag|(% style="width:131px" %) |(% style="width:518px" %)
350 +|=(% scope="row" style="width: 107px;" %)**SD label**|=(% style="width: 294px;" %)**Content**|=(% style="width: 114px;" %)**SD label**|=(% style="width: 561px;" %)**Content**
351 +|=(% style="width: 107px;" %)SM2020|(% style="width:294px" %)COM5 sending control on|(% style="width:114px" %)SD2020|(% style="width:561px" %)Display 0x1062 after 485BD is recognized after power-on.
352 +|=(% style="width: 107px;" %)SM2021|(% style="width:294px" %)COM5 send control/send prompt|(% style="width:114px" %)SD2021|(% style="width:561px" %)Display 485BD version information after 485BD is recognized after power-on.
353 +|=(% style="width: 107px;" %)SM 2022|(% style="width:294px" %)COM5 reception control on|(% style="width:114px" %)SD2022|(% style="width:561px" %)BD2 last error
354 +|=(% style="width: 107px;" %)SM2023|(% style="width:294px" %)COM5 accept control/receive prompt|(% style="width:114px" %)SD2023|(% style="width:561px" %)BD2 current error
355 +|=(% style="width: 107px;" %)SM2024|(% style="width:294px" %)COM5 communication complete flag|(% style="width:114px" %)SD2024|(% style="width:561px" %)BD2 error times
356 +|=(% style="width: 107px;" %)SM2025|(% style="width:294px" %)COM6 sending control on|(% style="width:114px" %)SD2025|(% style="width:561px" %)BD2 error communication port.
357 +|=(% style="width: 107px;" %)SM2026|(% style="width:294px" %)COM6 send control/send prompt|(% style="width:114px" %)SD2026|(% style="width:561px" %)BD2 communication timeout (1ms).
358 +|=(% style="width: 107px;" %)SM2027|(% style="width:294px" %)COM6 reception control on|(% style="width:114px" %) |(% style="width:561px" %)
359 +|=(% style="width: 107px;" %)SM2028|(% style="width:294px" %)COM6 accept control/receive prompt|(% style="width:114px" %) |(% style="width:561px" %)
360 +|=(% style="width: 107px;" %)SM2029|(% style="width:294px" %)COM6 communication complete flag|(% style="width:114px" %) |(% style="width:561px" %)
361 361  
362 362  = **8 Examples** =
363 363