... ... @@ -125,25 +125,25 @@
125 125  
126 126  In the case of user-defined protocol
127 127  
128 -|=(% scope="row" %)**Parameter**|=(% style="width: 563px;" %)**Content**|=(% style="width: 87px;" %)**Range**|=(% style="width: 175px;" %)**Data type**|=**Data type (label)**
129 -|=(S)|(% style="width:563px" %)The starting address of the register area where the data to be sent is stored|(% style="width:87px" %)-|(% style="width:175px" %)Unsigned BIN16 bits|ANY16
130 -|=(M)|(% style="width:563px" %)The length (in bytes) of the data to be sent|(% style="width:87px" %)0 to 528|(% style="width:175px" %)Unsigned BIN16 bits|ANY16
131 -|=(D)|(% style="width:563px" %)The start number of device that stores written data|(% style="width:87px" %)-|(% style="width:175px" %)Unsigned BIN16 bits|ANY16
132 -|=(N)|(% style="width:563px" %)Number of data written in bytes|(% style="width:87px" %)0 to 528|(% style="width:175px" %)Unsigned BIN16 bits|ANY16
133 -|=(N1)|(% style="width:563px" %)Specify communication port|(% style="width:87px" %)-|(% style="width:175px" %)Unsigned BIN16 bits|ANY16
128 +|=(% scope="row" %)**Parameter**|=(% style="width: 528px;" %)**Content**|=(% style="width: 98px;" %)**Range**|=(% style="width: 169px;" %)**Data type**|=(% style="width: 179px;" %)**Data type (label)**
129 +|=(S)|(% style="width:528px" %)The starting address of the register area where the data to be sent is stored|(% style="width:98px" %)-|(% style="width:169px" %)Unsigned BIN16 bits|(% style="width:179px" %)ANY16
130 +|=(M)|(% style="width:528px" %)The length (in bytes) of the data to be sent|(% style="width:98px" %)0 to 528|(% style="width:169px" %)Unsigned BIN16 bits|(% style="width:179px" %)ANY16
131 +|=(D)|(% style="width:528px" %)The start number of device that stores written data|(% style="width:98px" %)-|(% style="width:169px" %)Unsigned BIN16 bits|(% style="width:179px" %)ANY16
132 +|=(N)|(% style="width:528px" %)Number of data written in bytes|(% style="width:98px" %)0 to 528|(% style="width:169px" %)Unsigned BIN16 bits|(% style="width:179px" %)ANY16
133 +|=(N1)|(% style="width:528px" %)Specify communication port|(% style="width:98px" %)-|(% style="width:169px" %)Unsigned BIN16 bits|(% style="width:179px" %)ANY16
134 134  
135 135  Modbus protocol
136 136  
137 -|=(% scope="row" style="width: 98px;" %)**Parameter**|=(% style="width: 575px;" %)**Content**|=(% style="width: 86px;" %)**Range**|=(% style="width: 172px;" %)**Data type**|=(% style="width: 145px;" %)**Data type (label)**
138 -|=(% style="width: 98px;" %)(S)|(% style="width:575px" %)The high byte stores the station number of the slave station, and the low byte stores Modbus function codes.|(% style="width:86px" %)-|(% style="width:172px" %)Unsigned BIN16 bits|(% style="width:145px" %)ANY16
139 -|=(% style="width: 98px;" %)(M)|(% style="width:575px" %)The slave address provided by the slave, reads or writes data from this address of the slave.|(% style="width:86px" %)-|(% style="width:172px" %)Unsigned BIN16 bits|(% style="width:145px" %)ANY16
140 -|=(% style="width: 98px;" %)(D)|(% style="width:575px" %)Length. The length read or written by Modbus, and the unit is determined by the function code.|(% style="width:86px" %)-|(% style="width:172px" %)Unsigned BIN16 bits|(% style="width:145px" %)ANY16
141 -|=(% style="width: 98px;" %)(N)|(% style="width:575px" %)Start address for reading or writing data|(% style="width:86px" %)-|(% style="width:172px" %)Unsigned BIN16 bits|(% style="width:145px" %)ANY16
142 -|=(% style="width: 98px;" %)(N1)|(% style="width:575px" %)Specify communication port|(% style="width:86px" %)-|(% style="width:172px" %)Unsigned BIN16 bits|(% style="width:145px" %)ANY16
137 +|=(% scope="row" style="width: 98px;" %)**Parameter**|=(% style="width: 533px;" %)**Content**|=(% style="width: 97px;" %)**Range**|=(% style="width: 175px;" %)**Data type**|=(% style="width: 174px;" %)**Data type (label)**
138 +|=(% style="width: 98px;" %)(S)|(% style="width:533px" %)The high byte stores the station number of the slave station, and the low byte stores Modbus function codes.|(% style="width:97px" %)-|(% style="width:175px" %)Unsigned BIN16 bits|(% style="width:174px" %)ANY16
139 +|=(% style="width: 98px;" %)(M)|(% style="width:533px" %)The slave address provided by the slave, reads or writes data from this address of the slave.|(% style="width:97px" %)-|(% style="width:175px" %)Unsigned BIN16 bits|(% style="width:174px" %)ANY16
140 +|=(% style="width: 98px;" %)(D)|(% style="width:533px" %)Length. The length read or written by Modbus, and the unit is determined by the function code.|(% style="width:97px" %)-|(% style="width:175px" %)Unsigned BIN16 bits|(% style="width:174px" %)ANY16
141 +|=(% style="width: 98px;" %)(N)|(% style="width:533px" %)Start address for reading or writing data|(% style="width:97px" %)-|(% style="width:175px" %)Unsigned BIN16 bits|(% style="width:174px" %)ANY16
142 +|=(% style="width: 98px;" %)(N1)|(% style="width:533px" %)Specify communication port|(% style="width:97px" %)-|(% style="width:175px" %)Unsigned BIN16 bits|(% style="width:174px" %)ANY16
143 143  
144 144  **Device used**
145 145  
146 -|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Devices**|(((
146 +|(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="6" %)**Devices**|(((
147 147  **Offset**
148 148  
149 149  **modification**
... ... @@ -152,12 +152,12 @@
152 152  
153 153  **extension**
154 154  )))
155 -|X|Y|M|S|SM|T (bit)|C (bit)|LC (bit)|HSC (bit)|D.b|KnX|KnY|KnM|KnS|T|C|D|R|SD|LC|HSC|K|H|E|[D]|XXP
156 -|(% rowspan="5" %)RS2|(S)| | | | | | | | | | | | | | |●|●|●|●| | | |●|●| | |
157 -|(M)| | | | | | | | | | | | | | |●|●|●|●| | | |●|●| | |
158 -|(D)| | | | | | | | | | | | | | |●|●|●|●| | | |●|●| | |
159 -|(N)| | | | | | | | | | | | | | |●|●|●|●| | | |●|●| | |
160 -|(N1)| | | | | | | | | | | | | | | | | | | | | |●|●| | |
155 +|T|C|D|R|K|H|[D]|XXP
156 +|(% rowspan="5" %)RS2|(S)|●|●|●|●|●|●| |
157 +|(M)|●|●|●|●|●|●| |
158 +|(D)|●|●|●|●|●|●| |
159 +|(N)|●|●|●|●|●|●| |
160 +|(N1)| | | | |●|●| |
161 161  
162 162  **Function**
163 163  
... ... @@ -205,86 +205,86 @@
205 205  
206 206  **Error code**
207 207  
208 -|=(% scope="row" style="width: 116px;" %)**Error code**|=(% style="width: 959px;" %)**Content**
209 -|=(% style="width: 116px;" %)4085H|(% style="width:959px" %)(S), (M), (D) and (N) read address out of range of the device.
210 -|=(% style="width: 116px;" %)4084H|(% style="width:959px" %)Parameter value is out of the specified range.
208 +|=(% scope="row" style="width: 140px;" %)**Error code**|=(% style="width: 935px;" %)**Content**
209 +|=(% style="width: 140px;" %)4085H|(% style="width:935px" %)(S), (M), (D) and (N) read address out of range of the device.
210 +|=(% style="width: 140px;" %)4084H|(% style="width:935px" %)Parameter value is out of the specified range.
211 211  |=(% colspan="2" %)**COM3**
212 -|=(% style="width: 116px;" %)3280H|(% style="width:959px" %)COM3 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
213 -|=(% style="width: 116px;" %)3281H|(% style="width:959px" %)COM3 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
214 -|=(% style="width: 116px;" %)3282H|(% style="width:959px" %)COM3 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
215 -|=(% style="width: 116px;" %)3283H|(% style="width:959px" %)COM3 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
216 -|=(% style="width: 116px;" %)3284H|(% style="width:959px" %)COM3 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
217 -|=(% style="width: 116px;" %)3285H|(% style="width:959px" %)COM3 send buffer overflow. If this error appears, please contact your technician.
218 -|=(% style="width: 116px;" %)3286H|(% style="width:959px" %)COM3 function code error. Check whether the set function code is supported by PLC.
219 -|=(% style="width: 116px;" %)3287H|(% style="width:959px" %)COM3 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
220 -|=(% style="width: 116px;" %)3288H|(% style="width:959px" %)COM3 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
221 -|=(% style="width: 116px;" %)3289H|(% style="width:959px" %)COM3 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
222 -|=(% style="width: 116px;" %)328AH|(% style="width:959px" %)COM3 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
223 -|=(% style="width: 116px;" %)328BH|(% style="width:959px" %)COM3 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
224 -|=(% style="width: 116px;" %)328CH|(% style="width:959px" %)COM3 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed (Please refer to Modbus exception 04).
225 -|=(% style="width: 116px;" %)328DH|(% style="width:959px" %)COM3 slave confirmation. Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
226 -|=(% style="width: 116px;" %)328EH|(% style="width:959px" %)COM 3 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
227 -|=(% style="width: 116px;" %)328FH|(% style="width:959px" %)COM3 sending timed out. If this error appears, please contact your technician.
228 -|=(% style="width: 116px;" %)32A0H|(% style="width:959px" %)COM3 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
229 -|=(% style="width: 116px;" %)32A1H|(% style="width:959px" %)COM3 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
212 +|=(% style="width: 140px;" %)3280H|(% style="width:935px" %)COM3 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
213 +|=(% style="width: 140px;" %)3281H|(% style="width:935px" %)COM3 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
214 +|=(% style="width: 140px;" %)3282H|(% style="width:935px" %)COM3 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
215 +|=(% style="width: 140px;" %)3283H|(% style="width:935px" %)COM3 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
216 +|=(% style="width: 140px;" %)3284H|(% style="width:935px" %)COM3 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
217 +|=(% style="width: 140px;" %)3285H|(% style="width:935px" %)COM3 send buffer overflow. If this error appears, please contact your technician.
218 +|=(% style="width: 140px;" %)3286H|(% style="width:935px" %)COM3 function code error. Check whether the set function code is supported by PLC.
219 +|=(% style="width: 140px;" %)3287H|(% style="width:935px" %)COM3 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
220 +|=(% style="width: 140px;" %)3288H|(% style="width:935px" %)COM3 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
221 +|=(% style="width: 140px;" %)3289H|(% style="width:935px" %)COM3 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
222 +|=(% style="width: 140px;" %)328AH|(% style="width:935px" %)COM3 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
223 +|=(% style="width: 140px;" %)328BH|(% style="width:935px" %)COM3 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
224 +|=(% style="width: 140px;" %)328CH|(% style="width:935px" %)COM3 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed (Please refer to Modbus exception 04).
225 +|=(% style="width: 140px;" %)328DH|(% style="width:935px" %)COM3 slave confirmation. Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
226 +|=(% style="width: 140px;" %)328EH|(% style="width:935px" %)COM 3 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
227 +|=(% style="width: 140px;" %)328FH|(% style="width:935px" %)COM3 sending timed out. If this error appears, please contact your technician.
228 +|=(% style="width: 140px;" %)32A0H|(% style="width:935px" %)COM3 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
229 +|=(% style="width: 140px;" %)32A1H|(% style="width:935px" %)COM3 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
230 230  |=(% colspan="2" %)**COM4**
231 -|=(% style="width: 116px;" %)3380H|(% style="width:959px" %)COM4 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
232 -|=(% style="width: 116px;" %)3381H|(% style="width:959px" %)COM4 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
233 -|=(% style="width: 116px;" %)3382H|(% style="width:959px" %)COM4 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
234 -|=(% style="width: 116px;" %)3383H|(% style="width:959px" %)COM4 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
235 -|=(% style="width: 116px;" %)3384H|(% style="width:959px" %)COM4 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
236 -|=(% style="width: 116px;" %)3385H|(% style="width:959px" %)COM4 send buffer overflow. If this error appears, please contact your technician.
237 -|=(% style="width: 116px;" %)3386H|(% style="width:959px" %)COM4 function code error. Check whether the set function code is supported by PLC.
238 -|=(% style="width: 116px;" %)3387H|(% style="width:959px" %)COM4 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
239 -|=(% style="width: 116px;" %)3388H|(% style="width:959px" %)COM4 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
240 -|=(% style="width: 116px;" %)3389H|(% style="width:959px" %)COM4 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
241 -|=(% style="width: 116px;" %)338AH|(% style="width:959px" %)COM4 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
242 -|=(% style="width: 116px;" %)338BH|(% style="width:959px" %)COM4 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
243 -|=(% style="width: 116px;" %)338CH|(% style="width:959px" %)COM4 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed. (Please refer to Modbus exception 04).
244 -|=(% style="width: 116px;" %)338DH|(% style="width:959px" %)COM4 slave confirmation Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
245 -|=(% style="width: 116px;" %)338EH|(% style="width:959px" %)COM4 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
246 -|=(% style="width: 116px;" %)338FH|(% style="width:959px" %)COM4 send timed out. If this error appears, please contact your technician.
247 -|=(% style="width: 116px;" %)33A0H|(% style="width:959px" %)COM4 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
248 -|=(% style="width: 116px;" %)33A1H|(% style="width:959px" %)COM4 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
231 +|=(% style="width: 140px;" %)3380H|(% style="width:935px" %)COM4 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
232 +|=(% style="width: 140px;" %)3381H|(% style="width:935px" %)COM4 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
233 +|=(% style="width: 140px;" %)3382H|(% style="width:935px" %)COM4 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
234 +|=(% style="width: 140px;" %)3383H|(% style="width:935px" %)COM4 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
235 +|=(% style="width: 140px;" %)3384H|(% style="width:935px" %)COM4 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
236 +|=(% style="width: 140px;" %)3385H|(% style="width:935px" %)COM4 send buffer overflow. If this error appears, please contact your technician.
237 +|=(% style="width: 140px;" %)3386H|(% style="width:935px" %)COM4 function code error. Check whether the set function code is supported by PLC.
238 +|=(% style="width: 140px;" %)3387H|(% style="width:935px" %)COM4 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
239 +|=(% style="width: 140px;" %)3388H|(% style="width:935px" %)COM4 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
240 +|=(% style="width: 140px;" %)3389H|(% style="width:935px" %)COM4 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
241 +|=(% style="width: 140px;" %)338AH|(% style="width:935px" %)COM4 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
242 +|=(% style="width: 140px;" %)338BH|(% style="width:935px" %)COM4 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
243 +|=(% style="width: 140px;" %)338CH|(% style="width:935px" %)COM4 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed. (Please refer to Modbus exception 04).
244 +|=(% style="width: 140px;" %)338DH|(% style="width:935px" %)COM4 slave confirmation Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
245 +|=(% style="width: 140px;" %)338EH|(% style="width:935px" %)COM4 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
246 +|=(% style="width: 140px;" %)338FH|(% style="width:935px" %)COM4 send timed out. If this error appears, please contact your technician.
247 +|=(% style="width: 140px;" %)33A0H|(% style="width:935px" %)COM4 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
248 +|=(% style="width: 140px;" %)33A1H|(% style="width:935px" %)COM4 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
249 249  
250 250  |=(% colspan="2" scope="row" %)**COM5**
251 -|=(% style="width: 115px;" %)3480H|(% style="width:960px" %)COM5 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
252 -|=(% style="width: 115px;" %)3481H|(% style="width:960px" %)COM5 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
253 -|=(% style="width: 115px;" %)3482H|(% style="width:960px" %)COM5 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
254 -|=(% style="width: 115px;" %)3483H|(% style="width:960px" %)COM5 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
255 -|=(% style="width: 115px;" %)3484H|(% style="width:960px" %)COM5 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
256 -|=(% style="width: 115px;" %)3485H|(% style="width:960px" %)COM5 send buffer overflow. If this error appears, please contact your technician.
257 -|=(% style="width: 115px;" %)3486H|(% style="width:960px" %)COM5 function code error. Check whether the set function code is supported by PLC.
258 -|=(% style="width: 115px;" %)3487H|(% style="width:960px" %)COM5 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
259 -|=(% style="width: 115px;" %)3488H|(% style="width:960px" %)COM5 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
260 -|=(% style="width: 115px;" %)3489H|(% style="width:960px" %)COM5 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
261 -|=(% style="width: 115px;" %)348AH|(% style="width:960px" %)COM5 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
262 -|=(% style="width: 115px;" %)348BH|(% style="width:960px" %)COM5 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
263 -|=(% style="width: 115px;" %)348CH|(% style="width:960px" %)COM5 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed. (Please refer to Modbus exception 04).
264 -|=(% style="width: 115px;" %)348DH|(% style="width:960px" %)COM5 slave station confirmation Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
265 -|=(% style="width: 115px;" %)348EH|(% style="width:960px" %)COM5 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
266 -|=(% style="width: 115px;" %)348FH|(% style="width:960px" %)COM5 send timed out. If this error appears, please contact your technician.
267 -|=(% style="width: 115px;" %)34A0H|(% style="width:960px" %)COM5 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
268 -|=(% style="width: 115px;" %)34A1H|(% style="width:960px" %)COM5 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
251 +|=(% style="width: 139px;" %)3480H|(% style="width:936px" %)COM5 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
252 +|=(% style="width: 139px;" %)3481H|(% style="width:936px" %)COM5 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
253 +|=(% style="width: 139px;" %)3482H|(% style="width:936px" %)COM5 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
254 +|=(% style="width: 139px;" %)3483H|(% style="width:936px" %)COM5 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
255 +|=(% style="width: 139px;" %)3484H|(% style="width:936px" %)COM5 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
256 +|=(% style="width: 139px;" %)3485H|(% style="width:936px" %)COM5 send buffer overflow. If this error appears, please contact your technician.
257 +|=(% style="width: 139px;" %)3486H|(% style="width:936px" %)COM5 function code error. Check whether the set function code is supported by PLC.
258 +|=(% style="width: 139px;" %)3487H|(% style="width:936px" %)COM5 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
259 +|=(% style="width: 139px;" %)3488H|(% style="width:936px" %)COM5 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
260 +|=(% style="width: 139px;" %)3489H|(% style="width:936px" %)COM5 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
261 +|=(% style="width: 139px;" %)348AH|(% style="width:936px" %)COM5 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
262 +|=(% style="width: 139px;" %)348BH|(% style="width:936px" %)COM5 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
263 +|=(% style="width: 139px;" %)348CH|(% style="width:936px" %)COM5 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed. (Please refer to Modbus exception 04).
264 +|=(% style="width: 139px;" %)348DH|(% style="width:936px" %)COM5 slave station confirmation Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
265 +|=(% style="width: 139px;" %)348EH|(% style="width:936px" %)COM5 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
266 +|=(% style="width: 139px;" %)348FH|(% style="width:936px" %)COM5 send timed out. If this error appears, please contact your technician.
267 +|=(% style="width: 139px;" %)34A0H|(% style="width:936px" %)COM5 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
268 +|=(% style="width: 139px;" %)34A1H|(% style="width:936px" %)COM5 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
269 269  |=(% colspan="2" %)COM6
270 -|=(% style="width: 115px;" %)3580H|(% style="width:960px" %)COM6 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
271 -|=(% style="width: 115px;" %)3581H|(% style="width:960px" %)COM6 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
272 -|=(% style="width: 115px;" %)3582H|(% style="width:960px" %)COM6 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
273 -|=(% style="width: 115px;" %)3583H|(% style="width:960px" %)COM6 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
274 -|=(% style="width: 115px;" %)3584H|(% style="width:960px" %)COM6 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
275 -|=(% style="width: 115px;" %)3585H|(% style="width:960px" %)COM6 send buffer overflow. If this error appears, please contact your technician.
276 -|=(% style="width: 115px;" %)3586H|(% style="width:960px" %)COM6 function code error. Check whether the set function code is supported by PLC.
277 -|=(% style="width: 115px;" %)3587H|(% style="width:960px" %)COM6 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
278 -|=(% style="width: 115px;" %)3588H|(% style="width:960px" %)COM6 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
279 -|=(% style="width: 115px;" %)3589H|(% style="width:960px" %)COM6 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
280 -|=(% style="width: 115px;" %)358AH|(% style="width:960px" %)COM6 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
281 -|=(% style="width: 115px;" %)358BH|(% style="width:960px" %)COM6 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
282 -|=(% style="width: 115px;" %)358CH|(% style="width:960px" %)COM6 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed. (Please refer to Modbus exception 04).
283 -|=(% style="width: 115px;" %)358DH|(% style="width:960px" %)COM6 slave station acknowledges. Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
284 -|=(% style="width: 115px;" %)358EH|(% style="width:960px" %)COM6 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
285 -|=(% style="width: 115px;" %)358FH|(% style="width:960px" %)COM6 send timed out. If this error appears, please contact your technician.
286 -|=(% style="width: 115px;" %)35A0H|(% style="width:960px" %)COM6 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
287 -|=(% style="width: 115px;" %)35A1H|(% style="width:960px" %)COM6 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
270 +|=(% style="width: 139px;" %)3580H|(% style="width:936px" %)COM6 data reception error. There may be interference on the communication cable, it is recommended to connect GND.
271 +|=(% style="width: 139px;" %)3581H|(% style="width:936px" %)COM6 data reception timed out. Check the wiring, whether the serial port parameter settings correspond to master and slave, and whether there is interference. Check whether the response from the station is too late. It is recommended to increase the “sending interval".
272 +|=(% style="width: 139px;" %)3582H|(% style="width:936px" %)COM6 CRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
273 +|=(% style="width: 139px;" %)3583H|(% style="width:936px" %)COM6 LRC validation error. There may be interference on the communication cable, it is recommended to connect GND.
274 +|=(% style="width: 139px;" %)3584H|(% style="width:936px" %)COM6 station number is incorrectly configured. Check the slave station number setting, and check whether there is any problem with the receiving and sending mechanism from slave.
275 +|=(% style="width: 139px;" %)3585H|(% style="width:936px" %)COM6 send buffer overflow. If this error appears, please contact your technician.
276 +|=(% style="width: 139px;" %)3586H|(% style="width:936px" %)COM6 function code error. Check whether the set function code is supported by PLC.
277 +|=(% style="width: 139px;" %)3587H|(% style="width:936px" %)COM6 address error. Check whether the slave station has this address. (Please refer to Modbus exception 02).
278 +|=(% style="width: 139px;" %)3588H|(% style="width:936px" %)COM6 length error. Check whether the communication length exceeds the length range specified by Modbus protocol or user-defined protocol.
279 +|=(% style="width: 139px;" %)3589H|(% style="width:936px" %)COM6 data error. Check the parameters of the instruction for errors. Check whether the set value is supported by the slave station. (Please refer to Modbus exception 03).
280 +|=(% style="width: 139px;" %)358AH|(% style="width:936px" %)COM6 slave station is busy. Message returned from slave station: Slave station is busy. (Please refer to Modbus exception 06).
281 +|=(% style="width: 139px;" %)358BH|(% style="width:936px" %)COM6 slave does not support function codes. Check whether this function code is supported by the slave station. (Please refer to Modbus exception 01).
282 +|=(% style="width: 139px;" %)358CH|(% style="width:936px" %)COM6 slave failure. Message returned from slave station: Slave station failed, please check whether slave station failed. (Please refer to Modbus exception 04).
283 +|=(% style="width: 139px;" %)358DH|(% style="width:936px" %)COM6 slave station acknowledges. Message returned from slave station: slave station confirmation. (Please refer to Modbus exception 05).
284 +|=(% style="width: 139px;" %)358EH|(% style="width:936px" %)COM6 does not currently support this instruction or function. When set to slave protocol, the communication instructions related to master station or master station functions cannot be used. Please change the protocol or close the contact before the corresponding instruction or close the corresponding communication function.
285 +|=(% style="width: 139px;" %)358FH|(% style="width:936px" %)COM6 send timed out. If this error appears, please contact your technician.
286 +|=(% style="width: 139px;" %)35A0H|(% style="width:936px" %)COM6 unavailable gateway Message returned from the station: unavailable gateway. (Please refer to Modbus exception 0A).
287 +|=(% style="width: 139px;" %)35A1H|(% style="width:936px" %)COM6 indicates that no response was obtained from the target device. Message returned from the station: The device is not in the network. (Please refer to Modbus Exception 0B).
288 288  
289 289  **6 Address mapping**
290 290