Changes for page LX5V-2RS485-BD

Last modified by Jim on 2023/05/29 16:00

From version 9.1
edited by Stone Wu
on 2022/09/13 15:58
Change comment: There is no comment for this version
To version 12.1
edited by Stone Wu
on 2022/09/13 17:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -LV5V-2RS485-BD
1 +LX5V-2RS485-BD
Content
... ... @@ -291,27 +291,27 @@
291 291  When the BD board configures the serial port protocol as Modbus slave station protocol, the address mapping relationship accessed by the master station is as follows:
292 292  
293 293  |=(% colspan="5" %)**Word address**
294 -|(% style="width:246px" %)**Address type**|(% style="width:207px" %)**Occupation**|(% style="width:237px" %)**Address range**|(% style="width:164px" %)**Decimal address**|(% style="width:222px" %)**Total reserved address size**
295 -|(% style="width:246px" %)T0 to T511|(% style="width:207px" %)512 WORD|(% style="width:237px" %)0x0000 to 0x01ff|(% style="width:164px" %)0|(% style="width:222px" %)1536
296 -|(% style="width:246px" %)C0 to C255|(% style="width:207px" %)256 WORD|(% style="width:237px" %)0x0600 to 0x06ff|(% style="width:164px" %)1536|(% style="width:222px" %)1024
297 -|(% style="width:246px" %)LC0 to LC255|(% style="width:207px" %)512 WORD|(% style="width:237px" %)0x0A000 to 0x0BFF|(% style="width:164px" %)2560|(% style="width:222px" %)1024
298 -|(% style="width:246px" %)HSC0 to HSC15|(% style="width:207px" %)128 WORD|(% style="width:237px" %)0x0E00 to 0x0E1F|(% style="width:164px" %)3584|(% style="width:222px" %)512
299 -|(% style="width:246px" %)D0 to D7999|(% style="width:207px" %)8000 WORD|(% style="width:237px" %)0x1000 to 0x2F3F|(% style="width:164px" %)4096|(% style="width:222px" %)16384
300 -|(% style="width:246px" %)SD0 to SD4095|(% style="width:207px" %)4096 WORD|(% style="width:237px" %)0x5000 to 0x5FFF|(% style="width:164px" %)20480|(% style="width:222px" %)12288
301 -|(% style="width:246px" %)R0 to R30000|(% style="width:207px" %)30000 WORD|(% style="width:237px" %)0x8000 to 0xF52F|(% style="width:164px" %)32768|(% style="width:222px" %)30000
294 +|(% style="width:213px" %)**Address type**|(% style="width:212px" %)**Occupation**|(% style="width:226px" %)**Address range**|(% style="width:173px" %)**Decimal address**|(% style="width:252px" %)**Total reserved address size**
295 +|(% style="width:213px" %)T0 to T511|(% style="width:212px" %)512 WORD|(% style="width:226px" %)0x0000 to 0x01ff|(% style="width:173px" %)0|(% style="width:252px" %)1536
296 +|(% style="width:213px" %)C0 to C255|(% style="width:212px" %)256 WORD|(% style="width:226px" %)0x0600 to 0x06ff|(% style="width:173px" %)1536|(% style="width:252px" %)1024
297 +|(% style="width:213px" %)LC0 to LC255|(% style="width:212px" %)512 WORD|(% style="width:226px" %)0x0A000 to 0x0BFF|(% style="width:173px" %)2560|(% style="width:252px" %)1024
298 +|(% style="width:213px" %)HSC0 to HSC15|(% style="width:212px" %)128 WORD|(% style="width:226px" %)0x0E00 to 0x0E1F|(% style="width:173px" %)3584|(% style="width:252px" %)512
299 +|(% style="width:213px" %)D0 to D7999|(% style="width:212px" %)8000 WORD|(% style="width:226px" %)0x1000 to 0x2F3F|(% style="width:173px" %)4096|(% style="width:252px" %)16384
300 +|(% style="width:213px" %)SD0 to SD4095|(% style="width:212px" %)4096 WORD|(% style="width:226px" %)0x5000 to 0x5FFF|(% style="width:173px" %)20480|(% style="width:252px" %)12288
301 +|(% style="width:213px" %)R0 to R30000|(% style="width:212px" %)30000 WORD|(% style="width:226px" %)0x8000 to 0xF52F|(% style="width:173px" %)32768|(% style="width:252px" %)30000
302 302  
303 303  |=(% colspan="5" %)**Bit address**
304 -|(% style="width:245px" %)**Address type**|(% style="width:206px" %)**Occupation**|(% style="width:239px" %)**Address range**|(% style="width:158px" %)**Decimal address**|(% style="width:228px" %)**Total reserved address size**
305 -|(% style="width:245px" %)T0 to T511|(% style="width:206px" %)512 bits|(% style="width:239px" %)0x0000 to 0x01ff|(% style="width:158px" %)0|(% style="width:228px" %)1536
306 -|(% style="width:245px" %)C0 to C255|(% style="width:206px" %)256 bits|(% style="width:239px" %)0x0600 to 0x06ff|(% style="width:158px" %)1536|(% style="width:228px" %)1024
307 -|(% style="width:245px" %)LC0 to LC255|(% style="width:206px" %)256 bits|(% style="width:239px" %)0x0A00 to 0x0AFF|(% style="width:158px" %)2560|(% style="width:228px" %)1024
308 -|(% style="width:245px" %)HSC0 to HSC15|(% style="width:206px" %)64 bits|(% style="width:239px" %)0x0E00 to 0x0E0F|(% style="width:158px" %)3584|(% style="width:228px" %)512
309 -|(% style="width:245px" %)M0 to M8000|(% style="width:206px" %)8192 bits|(% style="width:239px" %)0x1000 to 0x2F3F|(% style="width:158px" %)4096|(% style="width:228px" %)16384
310 -|(% style="width:245px" %)SM0 to SM4095|(% style="width:206px" %)4096 bits|(% style="width:239px" %)0x5000 to 0x5FFF|(% style="width:158px" %)20480|(% style="width:228px" %)12288
311 -|(% style="width:245px" %)Reserved|(% style="width:206px" %) |(% style="width:239px" %)0x8000 to 0xBFFF|(% style="width:158px" %) |(% style="width:228px" %)16383
312 -|(% style="width:245px" %)S0 to S4095|(% style="width:206px" %)4096 bits|(% style="width:239px" %)0xC000 to 0xCFFF|(% style="width:158px" %)49152|(% style="width:228px" %)8192
313 -|(% style="width:245px" %)X0 to X1023|(% style="width:206px" %)1024 bits|(% style="width:239px" %)0xE000 to 0xE3FF|(% style="width:158px" %)57344|(% style="width:228px" %)4096
314 -|(% style="width:245px" %)Y0 to Y1023|(% style="width:206px" %)1024 bits|(% style="width:239px" %)0xF000 to 0xF3FF|(% style="width:158px" %)61440|(% style="width:228px" %)4096
304 +|(% style="width:212px" %)**Address type**|(% style="width:214px" %)**Occupation**|(% style="width:229px" %)**Address range**|(% style="width:170px" %)**Decimal address**|(% style="width:251px" %)**Total reserved address size**
305 +|(% style="width:212px" %)T0 to T511|(% style="width:214px" %)512 bits|(% style="width:229px" %)0x0000 to 0x01ff|(% style="width:170px" %)0|(% style="width:251px" %)1536
306 +|(% style="width:212px" %)C0 to C255|(% style="width:214px" %)256 bits|(% style="width:229px" %)0x0600 to 0x06ff|(% style="width:170px" %)1536|(% style="width:251px" %)1024
307 +|(% style="width:212px" %)LC0 to LC255|(% style="width:214px" %)256 bits|(% style="width:229px" %)0x0A00 to 0x0AFF|(% style="width:170px" %)2560|(% style="width:251px" %)1024
308 +|(% style="width:212px" %)HSC0 to HSC15|(% style="width:214px" %)64 bits|(% style="width:229px" %)0x0E00 to 0x0E0F|(% style="width:170px" %)3584|(% style="width:251px" %)512
309 +|(% style="width:212px" %)M0 to M8000|(% style="width:214px" %)8192 bits|(% style="width:229px" %)0x1000 to 0x2F3F|(% style="width:170px" %)4096|(% style="width:251px" %)16384
310 +|(% style="width:212px" %)SM0 to SM4095|(% style="width:214px" %)4096 bits|(% style="width:229px" %)0x5000 to 0x5FFF|(% style="width:170px" %)20480|(% style="width:251px" %)12288
311 +|(% style="width:212px" %)Reserved|(% style="width:214px" %) |(% style="width:229px" %)0x8000 to 0xBFFF|(% style="width:170px" %) |(% style="width:251px" %)16383
312 +|(% style="width:212px" %)S0 to S4095|(% style="width:214px" %)4096 bits|(% style="width:229px" %)0xC000 to 0xCFFF|(% style="width:170px" %)49152|(% style="width:251px" %)8192
313 +|(% style="width:212px" %)X0 to X1023|(% style="width:214px" %)1024 bits|(% style="width:229px" %)0xE000 to 0xE3FF|(% style="width:170px" %)57344|(% style="width:251px" %)4096
314 +|(% style="width:212px" %)Y0 to Y1023|(% style="width:214px" %)1024 bits|(% style="width:229px" %)0xF000 to 0xF3FF|(% style="width:170px" %)61440|(% style="width:251px" %)4096
315 315  
316 316  When using the Modbus master station to access the slave station, the RS2 instruction specifies the following address:
317 317  
... ... @@ -333,31 +333,31 @@
333 333  
334 334  **BD1:**
335 335  
336 -|=(% scope="row" style="width: 111px;" %)**SD label**|=(% style="width: 291px;" %)**Content**|=(% style="width: 115px;" %)**SD label**|=(% style="width: 559px;" %)**Content**
337 -|=(% style="width: 111px;" %)SM2000|(% style="width:291px" %)COM3 sending control on|(% style="width:115px" %)SD2000|(% style="width:559px" %)Display 0x1062 after 485BD is recognized after power-on.
338 -|=(% style="width: 111px;" %)SM2001|(% style="width:291px" %)COM3 send control/send prompt|(% style="width:115px" %)SD2001|(% style="width:559px" %)Display 485BD version information after 485BD is recognized after power-on.
339 -|=(% style="width: 111px;" %)SM 2002|(% style="width:291px" %)COM3 reception control on|(% style="width:115px" %)SD 2002|(% style="width:559px" %)BD1 last error
340 -|=(% style="width: 111px;" %)SM 2003|(% style="width:291px" %)COM3 accept control/receive prompt|(% style="width:115px" %)SD 2003|(% style="width:559px" %)BD1 current error
341 -|=(% style="width: 111px;" %)SM2004|(% style="width:291px" %)COM3 communication complete flag|(% style="width:115px" %)SD2004|(% style="width:559px" %)BD1 error times
342 -|=(% style="width: 111px;" %)SM 2005|(% style="width:291px" %)COM4 sending control on|(% style="width:115px" %)SD 2005|(% style="width:559px" %)BD1 error communication port.
343 -|=(% style="width: 111px;" %)SM 2006|(% style="width:291px" %)COM4 send control/send prompt|(% style="width:115px" %)SD2006|(% style="width:559px" %)BD1 communication timeout (1ms).
344 -|=(% style="width: 111px;" %)SM 2007|(% style="width:291px" %)COM4 reception control on|(% style="width:115px" %) |(% style="width:559px" %)
345 -|=(% style="width: 111px;" %)SM2008|(% style="width:291px" %)COM4 accept control/receive prompt|(% style="width:115px" %) |(% style="width:559px" %)
346 -|=(% style="width: 111px;" %)SM2009|(% style="width:291px" %)COM4 communication complete flag|(% style="width:115px" %) |(% style="width:559px" %)
336 +|=(% scope="row" style="width: 111px;" %)**SD label**|=(% style="width: 317px;" %)**Content**|=(% style="width: 132px;" %)**SD label**|=(% style="width: 516px;" %)**Content**
337 +|=(% style="width: 111px;" %)SM2000|(% style="width:317px" %)COM3 sending control on|(% style="width:132px" %)SD2000|(% style="width:516px" %)Display 0x1062 after 485BD is recognized after power-on.
338 +|=(% style="width: 111px;" %)SM2001|(% style="width:317px" %)COM3 send control/send prompt|(% style="width:132px" %)SD2001|(% style="width:516px" %)Display 485BD version information after 485BD is recognized after power-on.
339 +|=(% style="width: 111px;" %)SM 2002|(% style="width:317px" %)COM3 reception control on|(% style="width:132px" %)SD 2002|(% style="width:516px" %)BD1 last error
340 +|=(% style="width: 111px;" %)SM 2003|(% style="width:317px" %)COM3 accept control/receive prompt|(% style="width:132px" %)SD 2003|(% style="width:516px" %)BD1 current error
341 +|=(% style="width: 111px;" %)SM2004|(% style="width:317px" %)COM3 communication complete flag|(% style="width:132px" %)SD2004|(% style="width:516px" %)BD1 error times
342 +|=(% style="width: 111px;" %)SM 2005|(% style="width:317px" %)COM4 sending control on|(% style="width:132px" %)SD 2005|(% style="width:516px" %)BD1 error communication port.
343 +|=(% style="width: 111px;" %)SM 2006|(% style="width:317px" %)COM4 send control/send prompt|(% style="width:132px" %)SD2006|(% style="width:516px" %)BD1 communication timeout (1ms).
344 +|=(% style="width: 111px;" %)SM 2007|(% style="width:317px" %)COM4 reception control on|(% style="width:132px" %) |(% style="width:516px" %)
345 +|=(% style="width: 111px;" %)SM2008|(% style="width:317px" %)COM4 accept control/receive prompt|(% style="width:132px" %) |(% style="width:516px" %)
346 +|=(% style="width: 111px;" %)SM2009|(% style="width:317px" %)COM4 communication complete flag|(% style="width:132px" %) |(% style="width:516px" %)
347 347  
348 348  **BD2:**
349 349  
350 -|=(% scope="row" style="width: 107px;" %)**SD label**|=(% style="width: 294px;" %)**Content**|=(% style="width: 114px;" %)**SD label**|=(% style="width: 561px;" %)**Content**
351 -|=(% style="width: 107px;" %)SM2020|(% style="width:294px" %)COM5 sending control on|(% style="width:114px" %)SD2020|(% style="width:561px" %)Display 0x1062 after 485BD is recognized after power-on.
352 -|=(% style="width: 107px;" %)SM2021|(% style="width:294px" %)COM5 send control/send prompt|(% style="width:114px" %)SD2021|(% style="width:561px" %)Display 485BD version information after 485BD is recognized after power-on.
353 -|=(% style="width: 107px;" %)SM 2022|(% style="width:294px" %)COM5 reception control on|(% style="width:114px" %)SD2022|(% style="width:561px" %)BD2 last error
354 -|=(% style="width: 107px;" %)SM2023|(% style="width:294px" %)COM5 accept control/receive prompt|(% style="width:114px" %)SD2023|(% style="width:561px" %)BD2 current error
355 -|=(% style="width: 107px;" %)SM2024|(% style="width:294px" %)COM5 communication complete flag|(% style="width:114px" %)SD2024|(% style="width:561px" %)BD2 error times
356 -|=(% style="width: 107px;" %)SM2025|(% style="width:294px" %)COM6 sending control on|(% style="width:114px" %)SD2025|(% style="width:561px" %)BD2 error communication port.
357 -|=(% style="width: 107px;" %)SM2026|(% style="width:294px" %)COM6 send control/send prompt|(% style="width:114px" %)SD2026|(% style="width:561px" %)BD2 communication timeout (1ms).
358 -|=(% style="width: 107px;" %)SM2027|(% style="width:294px" %)COM6 reception control on|(% style="width:114px" %) |(% style="width:561px" %)
359 -|=(% style="width: 107px;" %)SM2028|(% style="width:294px" %)COM6 accept control/receive prompt|(% style="width:114px" %) |(% style="width:561px" %)
360 -|=(% style="width: 107px;" %)SM2029|(% style="width:294px" %)COM6 communication complete flag|(% style="width:114px" %) |(% style="width:561px" %)
350 +|=(% scope="row" style="width: 113px;" %)**SD label**|=(% style="width: 314px;" %)**Content**|=(% style="width: 131px;" %)**SD label**|=(% style="width: 518px;" %)**Content**
351 +|=(% style="width: 113px;" %)SM2020|(% style="width:314px" %)COM5 sending control on|(% style="width:131px" %)SD2020|(% style="width:518px" %)Display 0x1062 after 485BD is recognized after power-on.
352 +|=(% style="width: 113px;" %)SM2021|(% style="width:314px" %)COM5 send control/send prompt|(% style="width:131px" %)SD2021|(% style="width:518px" %)Display 485BD version information after 485BD is recognized after power-on.
353 +|=(% style="width: 113px;" %)SM 2022|(% style="width:314px" %)COM5 reception control on|(% style="width:131px" %)SD2022|(% style="width:518px" %)BD2 last error
354 +|=(% style="width: 113px;" %)SM2023|(% style="width:314px" %)COM5 accept control/receive prompt|(% style="width:131px" %)SD2023|(% style="width:518px" %)BD2 current error
355 +|=(% style="width: 113px;" %)SM2024|(% style="width:314px" %)COM5 communication complete flag|(% style="width:131px" %)SD2024|(% style="width:518px" %)BD2 error times
356 +|=(% style="width: 113px;" %)SM2025|(% style="width:314px" %)COM6 sending control on|(% style="width:131px" %)SD2025|(% style="width:518px" %)BD2 error communication port.
357 +|=(% style="width: 113px;" %)SM2026|(% style="width:314px" %)COM6 send control/send prompt|(% style="width:131px" %)SD2026|(% style="width:518px" %)BD2 communication timeout (1ms).
358 +|=(% style="width: 113px;" %)SM2027|(% style="width:314px" %)COM6 reception control on|(% style="width:131px" %) |(% style="width:518px" %)
359 +|=(% style="width: 113px;" %)SM2028|(% style="width:314px" %)COM6 accept control/receive prompt|(% style="width:131px" %) |(% style="width:518px" %)
360 +|=(% style="width: 113px;" %)SM2029|(% style="width:314px" %)COM6 communication complete flag|(% style="width:131px" %) |(% style="width:518px" %)
361 361  
362 362  = **8 Examples** =
363 363