Changes for page LCM-2WT

Last modified by Devin Chen on 2024/10/22 09:06

From version 2.1
edited by Leo Wei
on 2022/06/08 14:42
Change comment: Renamed from xwiki:3\.LCM.LCM-2WT.WebHome
To version 4.1
edited by Devin Chen
on 2024/10/22 09:00
Change comment: There is no comment for this version

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -3\.LCM.WebHome
1 +Expansions.3\.LCM.WebHome
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.admin
1 +XWiki.DevinChen
Content
... ... @@ -46,10 +46,10 @@
46 46  == **3.1 Dimensions** ==
47 47  
48 48  (% style="text-align:center" %)
49 -[[image:LCM-2WT user manual_html_f8c64fd33c53cb96.png||class="img-thumbnail" height="332" width="800"]]
49 +[[image:LCM-2WT user manual_html_f8c64fd33c53cb96.png||height="332" width="800" class="img-thumbnail"]]
50 50  
51 51  (% style="text-align:center" %)
52 -[[image:LCM-2WT user manual_html_f3ff8ddbebac7ca3.png||class="img-thumbnail" height="374" width="600"]]
52 +[[image:LCM-2WT user manual_html_f3ff8ddbebac7ca3.png||height="374" width="600" class="img-thumbnail"]]
53 53  
54 54  ①COM: communication indicator of communication board and acquisition board
55 55  
... ... @@ -92,7 +92,7 @@
92 92  * Apply 0.5 to 0.8 N.m (5 to 8 kgf.cm) torque to tighten the terminals
93 93  
94 94  (% style="text-align:center" %)
95 -[[image:LCM-2WT user manual_html_567be68423413d26.png||class="img-thumbnail" height="199" width="300"]]
95 +[[image:LCM-2WT user manual_html_567be68423413d26.png||height="199" width="300" class="img-thumbnail"]]
96 96  )))
97 97  
98 98  == **3.2 Terminals** ==
... ... @@ -124,7 +124,7 @@
124 124  1. The sensor with 4 wires requires E1+ connecting with F1+, E1 connecting with F1.
125 125  
126 126  (% style="text-align:center" %)
127 -[[image:1623052932789-253.png||class="img-thumbnail" height="313" width="400"]]
127 +[[image:1623052932789-253.png||height="313" width="400" class="img-thumbnail"]]
128 128  
129 129  
130 130  )))
... ... @@ -731,11 +731,11 @@
731 731  **1.DIP switch introduction**
732 732  
733 733  (% style="text-align:center" %)
734 -[[image:LCM-2WT user manual_html_93aa56002bebd679.png||class="img-thumbnail" height="191" width="400"]]
734 +[[image:LCM-2WT user manual_html_93aa56002bebd679.png||height="191" width="400" class="img-thumbnail"]]
735 735  
736 736  
737 737  (% style="text-align:center" %)
738 -[[image:LCM-2WT user manual_html_79b07e8411c992f6.png||class="img-thumbnail" height="681" width="500"]]
738 +[[image:LCM-2WT user manual_html_79b07e8411c992f6.png||height="681" width="500" class="img-thumbnail"]]
739 739  
740 740  Figure 6 ‑1 DIP switch
741 741  
... ... @@ -818,7 +818,7 @@
818 818  Set the station number as 2 and the baud rate as 115200 according to chapter 6.3.
819 819  
820 820  (% style="text-align:center" %)
821 -[[image:LCM-2WT user manual_html_221220adb9906bdd.png||class="img-thumbnail" height="272" width="700"]]
821 +[[image:LCM-2WT user manual_html_221220adb9906bdd.png||height="272" width="700" class="img-thumbnail"]]
822 822  
823 823  PLC COM2 is set as MODBUS master, parameter is 115200, 1, 8 ,even.
824 824  
... ... @@ -825,7 +825,7 @@
825 825  == **7.2 The current state** ==
826 826  
827 827  (% style="text-align:center" %)
828 -[[image:LCM-2WT user manual_html_173d560166f58213.png||class="img-thumbnail" height="276" width="700"]]
828 +[[image:LCM-2WT user manual_html_173d560166f58213.png||height="276" width="700" class="img-thumbnail"]]
829 829  
830 830  Read the current state from BFM4, refer to the detail in chapter 5.2.
831 831  
... ... @@ -835,8 +835,7 @@
835 835  
836 836  The adjustment is to match the value of the module to the load cell.
837 837  
838 -(% style="text-align:center" %)
839 -[[image:LCM-2WT user manual_html_6b8ba1f27fc70625.png||class="img-thumbnail" height="419" width="700"]]
838 +[[image:image-20230107103126-1.png]]
840 840  
841 841  * Step 1: Put nothing on the load cell
842 842  * Step 2: Write 0x001 to bfm8
... ... @@ -846,19 +846,17 @@
846 846  
847 847  == **7.4 Net weight and tare 1** ==
848 848  
849 -(% style="text-align:center" %)
850 -[[image:LCM-2WT user manual_html_9c77452304086840.png||class="img-thumbnail" height="438" width="700"]]
848 +[[image:image-20230107103147-2.png]]
851 851  
852 852  * Step 1: Write K1 to BFM6 set the tare value
853 853  * Step 2: Write k1 to BFM7 (display net weight)
854 854  * Step 3: Write k0 to BFM7 (display gross weight)
855 855  
856 -== **7.5 Net weight and tare 2** ==
854 +== **7.5 Filter Method Setting** ==
857 857  
858 858  After the filter mode or filter strength is changed, it needs to be recalibrated.
859 859  
860 -(% style="text-align:center" %)
861 -[[image:LCM-2WT user manual_html_c4648aa945cc090d.png||class="img-thumbnail" height="203" width="700"]]
858 +[[image:image-20230107103159-3.png]]
862 862  
863 863  * Step 1: Configure filter mode by writing value to BFM10
864 864  * Step 2: Set the filter strength (BFM11)
... ... @@ -869,8 +869,7 @@
869 869  
870 870  The zero tracking strength is 0, which means that zero tracking is not turned on.
871 871  
872 -(% style="text-align:center" %)
873 -[[image:1623053104387-331.png||class="img-thumbnail" height="215" width="700"]]
869 +[[image:image-20230107103209-4.png]]
874 874  
875 875  = **8 Diagnosis** =
876 876  
image-20230107103126-1.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +557.4 KB
Content
image-20230107103147-2.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +601.1 KB
Content
image-20230107103159-3.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +267.8 KB
Content
image-20230107103209-4.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Jim
Size
... ... @@ -1,0 +1,1 @@
1 +311.5 KB
Content