Changes for page LCM-2WT
Last modified by Devin Chen on 2024/10/22 09:06
From version 2.1
edited by Leo Wei
on 2022/06/08 14:42
on 2022/06/08 14:42
Change comment:
Renamed from xwiki:3\.LCM.LCM-2WT.WebHome
To version 4.1
edited by Devin Chen
on 2024/10/22 09:00
on 2024/10/22 09:00
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 4 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -3\.LCM.WebHome 1 +Expansions.3\.LCM.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.DevinChen - Content
-
... ... @@ -46,10 +46,10 @@ 46 46 == **3.1 Dimensions** == 47 47 48 48 (% style="text-align:center" %) 49 -[[image:LCM-2WT user manual_html_f8c64fd33c53cb96.png|| class="img-thumbnail" height="332" width="800"]]49 +[[image:LCM-2WT user manual_html_f8c64fd33c53cb96.png||height="332" width="800" class="img-thumbnail"]] 50 50 51 51 (% style="text-align:center" %) 52 -[[image:LCM-2WT user manual_html_f3ff8ddbebac7ca3.png|| class="img-thumbnail" height="374" width="600"]]52 +[[image:LCM-2WT user manual_html_f3ff8ddbebac7ca3.png||height="374" width="600" class="img-thumbnail"]] 53 53 54 54 ①COM: communication indicator of communication board and acquisition board 55 55 ... ... @@ -92,7 +92,7 @@ 92 92 * Apply 0.5 to 0.8 N.m (5 to 8 kgf.cm) torque to tighten the terminals 93 93 94 94 (% style="text-align:center" %) 95 -[[image:LCM-2WT user manual_html_567be68423413d26.png|| class="img-thumbnail" height="199" width="300"]]95 +[[image:LCM-2WT user manual_html_567be68423413d26.png||height="199" width="300" class="img-thumbnail"]] 96 96 ))) 97 97 98 98 == **3.2 Terminals** == ... ... @@ -124,7 +124,7 @@ 124 124 1. The sensor with 4 wires requires E1+ connecting with F1+, E1 connecting with F1. 125 125 126 126 (% style="text-align:center" %) 127 -[[image:1623052932789-253.png|| class="img-thumbnail" height="313" width="400"]]127 +[[image:1623052932789-253.png||height="313" width="400" class="img-thumbnail"]] 128 128 129 129 130 130 ))) ... ... @@ -731,11 +731,11 @@ 731 731 **1.DIP switch introduction** 732 732 733 733 (% style="text-align:center" %) 734 -[[image:LCM-2WT user manual_html_93aa56002bebd679.png|| class="img-thumbnail" height="191" width="400"]]734 +[[image:LCM-2WT user manual_html_93aa56002bebd679.png||height="191" width="400" class="img-thumbnail"]] 735 735 736 736 737 737 (% style="text-align:center" %) 738 -[[image:LCM-2WT user manual_html_79b07e8411c992f6.png|| class="img-thumbnail" height="681" width="500"]]738 +[[image:LCM-2WT user manual_html_79b07e8411c992f6.png||height="681" width="500" class="img-thumbnail"]] 739 739 740 740 Figure 6 ‑1 DIP switch 741 741 ... ... @@ -818,7 +818,7 @@ 818 818 Set the station number as 2 and the baud rate as 115200 according to chapter 6.3. 819 819 820 820 (% style="text-align:center" %) 821 -[[image:LCM-2WT user manual_html_221220adb9906bdd.png|| class="img-thumbnail" height="272" width="700"]]821 +[[image:LCM-2WT user manual_html_221220adb9906bdd.png||height="272" width="700" class="img-thumbnail"]] 822 822 823 823 PLC COM2 is set as MODBUS master, parameter is 115200, 1, 8 ,even. 824 824 ... ... @@ -825,7 +825,7 @@ 825 825 == **7.2 The current state** == 826 826 827 827 (% style="text-align:center" %) 828 -[[image:LCM-2WT user manual_html_173d560166f58213.png|| class="img-thumbnail" height="276" width="700"]]828 +[[image:LCM-2WT user manual_html_173d560166f58213.png||height="276" width="700" class="img-thumbnail"]] 829 829 830 830 Read the current state from BFM4, refer to the detail in chapter 5.2. 831 831 ... ... @@ -835,8 +835,7 @@ 835 835 836 836 The adjustment is to match the value of the module to the load cell. 837 837 838 -(% style="text-align:center" %) 839 -[[image:LCM-2WT user manual_html_6b8ba1f27fc70625.png||class="img-thumbnail" height="419" width="700"]] 838 +[[image:image-20230107103126-1.png]] 840 840 841 841 * Step 1: Put nothing on the load cell 842 842 * Step 2: Write 0x001 to bfm8 ... ... @@ -846,19 +846,17 @@ 846 846 847 847 == **7.4 Net weight and tare 1** == 848 848 849 -(% style="text-align:center" %) 850 -[[image:LCM-2WT user manual_html_9c77452304086840.png||class="img-thumbnail" height="438" width="700"]] 848 +[[image:image-20230107103147-2.png]] 851 851 852 852 * Step 1: Write K1 to BFM6 set the tare value 853 853 * Step 2: Write k1 to BFM7 (display net weight) 854 854 * Step 3: Write k0 to BFM7 (display gross weight) 855 855 856 -== **7.5 Netweightandtare2** ==854 +== **7.5 Filter Method Setting** == 857 857 858 858 After the filter mode or filter strength is changed, it needs to be recalibrated. 859 859 860 -(% style="text-align:center" %) 861 -[[image:LCM-2WT user manual_html_c4648aa945cc090d.png||class="img-thumbnail" height="203" width="700"]] 858 +[[image:image-20230107103159-3.png]] 862 862 863 863 * Step 1: Configure filter mode by writing value to BFM10 864 864 * Step 2: Set the filter strength (BFM11) ... ... @@ -869,8 +869,7 @@ 869 869 870 870 The zero tracking strength is 0, which means that zero tracking is not turned on. 871 871 872 -(% style="text-align:center" %) 873 -[[image:1623053104387-331.png||class="img-thumbnail" height="215" width="700"]] 869 +[[image:image-20230107103209-4.png]] 874 874 875 875 = **8 Diagnosis** = 876 876
- image-20230107103126-1.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +557.4 KB - Content
- image-20230107103147-2.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +601.1 KB - Content
- image-20230107103159-3.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +267.8 KB - Content
- image-20230107103209-4.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Jim - Size
-
... ... @@ -1,0 +1,1 @@ 1 +311.5 KB - Content