Changes for page 08 Motion Control
Last modified by Iris on 2026/04/03 10:39
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -15,8 +15,6 @@ 15 15 16 16 Device used (only a single device can be used, and device splicing and offset are not supported) 17 17 18 - 19 - 20 20 |=(% rowspan="2" %)**Instruction**|=(% rowspan="2" %)**Parameter**|=(% colspan="24" %)**Devices**|=**Index modification**|=**Pulse expansion** 21 21 |**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP** 22 22 |(% rowspan="8" %)MC_POWER|Enable|●|●|●|●|●| | | | | | | | | | | | | | | | | | | | | ... ... @@ -36,20 +36,19 @@ 36 36 37 37 Variable Type Used 38 38 37 +|**Instruction**|**Pin type**|**Variable type**|**Variable type**|**Can be empty or not**|**Range**|**Description** 38 +|(% rowspan="8" %)MC_POWER|(% rowspan="4" %)Input|Enable|BOOL|No|TRUE/FALSE|Enable 39 +|EnablePositive|BOOL|No|TRUE/FALSE|Allow movement in the positive direction 40 +|EnableNegative|BOOL|No|TRUE/FALSE|Allow movement in negative direction 41 +|Axis|WORD|No|[0,65535]|Axis number 42 +|(% rowspan="4" %)Output|Status|BOOL|Yes|TRUE/FALSE|Enable status 43 +|Valid|BOOL|Yes|TRUE/FALSE|Data valid or not 44 +|Error|BOOL|Yes|TRUE/FALSE|Whether there is an error or not 45 +|ErrorID|DWORD|Yes|-|Error code (See [8.11 Error code comparison table]) 39 39 40 -|=**Instruction**|=**Parameter**|=**Variable type**|=**Can be empty or not**|=**Range**|=**Description** 41 -|(% colspan="1" rowspan="8" %)MC_POWER|Enable|BOOL|No|TRUE/FALSE|Enable 42 -|EnablePositive|BOOL|No|TRUE/FALSE|Allow motion in the positive direction 43 -|EnableNegative|BOOL|No|TRUE/FALSE|Allow motion in negative direction 44 -|Axis|WORD|No|0 to 65535|Axis number 45 -|Status|BOOL|No|TRUE/FALSE|Enable status 46 -|Valid|BOOL|No|TRUE/FALSE|Data valid or not 47 -|Error|BOOL|No|TRUE/FALSE|Whether there is an error or not 48 -|ErrorID|DWORD|No|-|[Error code] 49 - 50 50 Function 51 51 52 -* This func tion block must be enabled if an axis is to participate in motion.49 +* This funcion block must be enabled if an axis is to participate in motion. 53 53 * The function is as follows: 54 54 55 55 1. When the Enable input is TRUE, the power to the drive is enabled, not to the function block itself; ... ... @@ -814,6 +814,9 @@ 814 814 Precautions 815 815 816 816 * This function block is not available when the axis does not exist. 814 +* In profile mode, the STOP command requires the mapper to map the PDOs of 0x6060, 0x6061, 0x60FF, and 0x606C for normal operation; 815 +* In CST/CSV mode, triggering STOP switches to synchronous velocity mode; 816 +* In CST/CSV mode, the STOP command requires the mapper to map the PDOs of 0x6060, 0x6061, 0x60FF, and 0x606C for normal operation; 817 817 818 818 Error code 819 819 ... ... @@ -1497,7 +1497,7 @@ 1497 1497 Variable type used 1498 1498 1499 1499 |=**Instruction**|=**Pin**|=**Parameter**|=**Variable type**|=**Can it be empty**|=**Range**|=**Description** 1500 -|(% colspan="1" rowspan="1 0" %)(((1500 +|(% colspan="1" rowspan="11" %)((( 1501 1501 1502 1502 1503 1503 ... ... @@ -1540,7 +1540,7 @@ 1540 1540 1541 1541 Others: Reserved 1542 1542 ))) 1543 -|(% colspan="1" rowspan=" 5" %)(((1543 +|(% colspan="1" rowspan="6" %)((( 1544 1544 1545 1545 1546 1546 ... ... @@ -1548,6 +1548,7 @@ 1548 1548 )))|Done|BOOL|Yes|TRUE/FALSE|Busy flag 1549 1549 |BusY|BOOL|Yes|TRUE/FALSE|Aborted flag 1550 1550 |InstructionAborted|BOOL|Yes|TRUE/FALSE|Abortion flag 1551 +|ReadyUpdate|BOOL|Yes|TRUE/FALSE|Cam table update comp flag 1551 1551 |Error|BOOL|Yes| |Whether there is an error or not 1552 1552 |ErrorID|DWORD|Yes| |Error Code (Please check [8.10 Error Code Cross-reference Table] ) 1553 1553 ... ... @@ -1622,9 +1622,9 @@ 1622 1622 MC_SAVECAMTABLE 1623 1623 )))|(% colspan="1" rowspan="2" %)Input|Execute|BOOL|No|TRUE/FALSE|Enable 1624 1624 |CamTableID|INT|No|-|Cam tableID 1625 -|(% colspan="1" rowspan="5" %)Output|Done|BOOL|Yes|TRUE/FALSE| Busyflag1626 -|BusY|BOOL|Yes|TRUE/FALSE| Abortedflag1627 -|InstructionAborted|BOOL|Yes|TRUE/FALSE|Abort ionflag1626 +|(% colspan="1" rowspan="5" %)Output|Done|BOOL|Yes|TRUE/FALSE|Completion flag 1627 +|BusY|BOOL|Yes|TRUE/FALSE|Busy flag 1628 +|InstructionAborted|BOOL|Yes|TRUE/FALSE|Abort flag 1628 1628 |Error|BOOL|Yes|-|Whether there is an error or not 1629 1629 |ErrorID|DWORD|Yes|-|Error Code (Please check [8.10 Error Code Cross-reference Table] 1630 1630 ... ... @@ -2207,6 +2207,12 @@ 2207 2207 2208 2208 2209 2209 2211 + 2212 + 2213 + 2214 + 2215 + 2216 + 2210 2210 == **Management functions of axis group motion control** == 2211 2211 2212 2212 ---- ... ... @@ -3820,11 +3820,11 @@ 3820 3820 3821 3821 **Function** 3822 3822 3823 -* The MC _ MoveVelocityfunction block is used to continue the movement of the previous function block and move according to the speed specified by the function block. The input values of acceleration, deceleration and jerk are used to monitor whether the corresponding values of the controlled axis are within the input values.3830 +* The MC_ MOVEVELOCITY_CSV function block is used to continue the movement of the previous function block and move according to the speed specified by the function block. The input values of acceleration, deceleration and jerk are used to monitor whether the corresponding values of the controlled axis are within the input values. 3824 3824 * Since there is no input signal of position or distance, the function block will move until other function block sends a new command to stop movement of this function block; 3825 3825 * When the speed of the controlled axis reaches the input parameter ‘Velocity’ setpoint, the output parameter ‘InVelocity’ is set. Once the input ‘Execute’ signal detects a falling edge or other function block to abort this function block, the output parameter InVelocity is reset; 3826 -* The MC_ MoveVelocityfunction block shall be in a stopped motion state or a single-axis operation state when the controlled axis is operated. After this function block is triggered, the controlled axis transitions to the ‘Continuous Motion’ state. If the controlled axis is not in the above state, the function block is not executed, Error output is set;3827 -* The MC_ MoveVelocityfunction block can be triggered repeatedly multiple times.3833 +* The MC_ MOVEVELOCITY_CSV function block shall be in a stopped motion state or a single-axis operation state when the controlled axis is operated. After this function block is triggered, the controlled axis transitions to the ‘Continuous Motion’ state. If the controlled axis is not in the above state, the function block is not executed, Error output is set; 3834 +* The MC_ MOVEVELOCITY_CSV function block can be triggered repeatedly multiple times. 3828 3828 3829 3829 **Error code** 3830 3830 ... ... @@ -3880,7 +3880,11 @@ 3880 3880 3881 3881 VELOCITY 3882 3882 )))|Execute|BOOL|No|TRUE/FALSE|Enable 3883 -|Velocity|LREAL|No|[0,999999999.999999]|Setting velocity 3890 +|Velocity|LREAL|No|((( 3891 +[-999999999.999999,99999 3892 + 3893 +9999.999999] 3894 +)))|Setting velocity 3884 3884 |Axis|((( 3885 3885 WORD 3886 3886 ... ... @@ -4885,16 +4885,41 @@ 4885 4885 ---- 4886 4886 4887 4887 (% style="text-align:center" %) 4888 -[[image:1 709016272018-406.png||height="669" width="631"]]4899 +[[image:123.png||height="659" width="621"]] 4889 4889 4901 +**✎Note**: Continuous line arrows indicate transitions via command. Dashed line arrows indicate automatic transitions, which occur when a command on an axis ends or a related system transition occurs (e.g., a related error). 4902 + 4903 +① The transition condition for any state to fault stop or deceleration stop is: a fault occurs on the axis. 4904 + 4905 +② The transition condition for any state to off is: MC_Power.Enable = FALSE and there is no fault on the axis. 4906 + 4907 +③ MC_Reset = FALSE and MC_Power.Status = FALSE. 4908 + 4909 +④ MC_Reset = TRUE, MC_Power.Status = TRUE, and MC_Power.Enable = TRUE. 4910 + 4911 +⑤ MC_Power.Enable = TRUE and MC_Power.Status = TRUE. 4912 + 4913 +⑥ MC_Stop.Done = TRUE and MC_Stop.Execute = FALSE. 4914 + 4890 4890 === **Axis group motion control status diagram** === 4891 4891 4892 4892 ---- 4893 4893 4894 4894 (% style="text-align:center" %) 4895 -[[image: 1709016323709-202.png]]4920 +[[image:234.png||height="405" width="669"]] 4896 4896 4922 +**✎Note**: For all states in the diagram could be transitioned to GroupDisabled state by MC_GroupDisable or MC_UngroupAllAxes. 4897 4897 4924 +① Applies to all non-administrative (i.e., motion control) function blocks. 4925 + 4926 +② In the GroupErrorStop or GroupStopping state, all function blocks can be invoked, although they are not executed (except that MC_GroupReset is executed in the GroupErrorStop state and any other errors are generated). In exceptional cases, GroupErrorStop or GroupStopping will transition to GroupStandby or GroupErrorStop accordingly. 4927 + 4928 +③ MC_GroupStop.Done = TRUE and MC_GroupStop.Execute = FALSE. 4929 + 4930 +④ The state transition is available if the last axis is removed from the axis group. 4931 + 4932 +⑤ The transition is available when the axis group is non-empty. 4933 + 4898 4898 === **Arc mode description** === 4899 4899 4900 4900 ---- ... ... @@ -4906,22 +4906,20 @@ 4906 4906 4907 4907 Features 4908 4908 )))|((( 4909 -The arc composed of starting point, auxiliary point and ending point is regarded as the trajectory circle of motion. 4910 - 4911 - 4945 +The arc path consists of the starting point, auxiliary points, and ending point. 4912 4912 )))|((( 4913 4913 4914 4914 4915 -The a uxiliarypoint is definedasthecenterof themotion trajectory, sothe auxiliarypointshould be ontheperpendicular lineconnecting thestartingpoint and theending point.4949 +The arc path consists of the starting point, the center point, and theending point. 4916 4916 4917 4917 4918 4918 4919 4919 )))|((( 4920 - Accordingto theright-handgriprule,theending point and the vectorperpendicular to the plane ofthe circleare defined, and the lengthofthevector corresponds to the radius of the circle.4954 +The arc is determined by its starting point, ending point, and the normal vector of the plane containing the circle. 4921 4921 4922 4922 The direction of the vector determines the direction of CW and CCW circles. 4923 4923 4924 -The majorarc andminorarc are determinedbypath choice.4958 +The vector length is the radius of the arc. 4925 4925 ))) 4926 4926 |((( 4927 4927
- 123.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Iris - Size
-
... ... @@ -1,0 +1,1 @@ 1 +292.1 KB - Content
- 1770693592357-540.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Iris - Size
-
... ... @@ -1,0 +1,1 @@ 1 +133.1 KB - Content
- 234.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Iris - Size
-
... ... @@ -1,0 +1,1 @@ 1 +223.0 KB - Content