Last modified by Iris on 2026/03/30 11:47

From version 8.1
edited by Iris
on 2026/03/30 11:47
Change comment: There is no comment for this version
To version 3.1
edited by Iris
on 2025/10/22 15:32
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -1665,13 +1665,13 @@
1665 1665  
1666 1666  The extended function is mainly used to communicate with PLC Editor 2.
1667 1667  
1668 -== **Communication function block** ==
1668 +== [[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml2512\wps2.png]][[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml2512\wps3.png]]**10.7 Communication function block** ==
1669 1669  
1670 -=== **SERIAL_MODBUS_WR** ===
1670 +=== [[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml2512\wps4.png]]**1. SERIAL_MODBUS_WR** ===
1671 1671  
1672 1672  SERIAL_MODBUS_WR - Modbus master serial communication
1673 1673  
1674 -[[image:1761118509428-681.png||height="227" width="212"]]
1674 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml2512\wps5.jpg]]
1675 1675  
1676 1676  This function block is the setting function block for sending protocol frames by the Modbus master station (whether RTU or ASCII). When the contact in front of Enable is turned ON, according to the communication port, station number, function code, slave station address, quantity and mapped data address set by the function block, the data frame is combined and sent.
1677 1677  
... ... @@ -1680,29 +1680,32 @@
1680 1680  |(% rowspan="2" %)**Instruction**|(% rowspan="2" %)**Parameter**|(% colspan="24" %)**Device**|(((
1681 1681  **Offset**
1682 1682  
1683 -**modification**
1683 +**Modification**
1684 1684  )))|(((
1685 1685  **Pulse**
1686 1686  
1687 -**expansion**
1687 +**Expansion**
1688 1688  )))
1689 1689  |**X**|**Y**|**M**|**S**|**SM**|**T(bit)**|**C(bit)**|**LC(bit)**|**HSC(bit)**|**D.b**|**KnX**|**KnY**|**KnM**|**KnS**|**T**|**C**|**D**|**R**|**SD**|**LC**|**HSC**|**K**|**H**|**E**|**[D]**|**XXP**
1690 -|(% rowspan="12" %)(((
1691 -SERIAL_
1690 +|(% rowspan="15" %)(((
1691 +SERIAL
1692 1692  
1693 1693  MODBUS_WR
1694 -)))|Enable|●|●|●|●|●| | | | | | | | | | | | | | | | | | | | |
1695 -|CommunicationPort| | | | | | | | | | | | | | |●|●|●|●|●| | | | | | |
1696 -|SlaveID| | | | | | | | | | | | | | |●|●|●|●|●| | | | | | |
1697 -|FunctionCode| | | | | | | | | | | | | | |●|●|●|●|●| | | | | | |
1698 -|SlaveAddress| | | | | | | | | | | | | | |●|●|●|●|●| | | | | | |
1699 -|Count| | | | | | | | | | | | | | |●|●|●|●|●| | | | | | |
1700 -|Data| | | | | | | | | | | | | | | | |●|●| | | | | | | |
1701 -|Done| |●|●|●|●| | | | | | | | | | | | | | | | | | | | |
1702 -|Busy| |●|●|●|●| | | | | | | | | | | | | | | | | | | | |
1703 -|Active| |●|●|●|●| | | | | | | | | | | | | | | | | | | | |
1704 -|Error| |●|●|●|●| | | | | | | | | | | | | | | | | | | | |
1705 -|ErrorID| | | | | | | | | | | | | | | | |●|●| | | | | | | |
1694 +)))|Enable|●|●|●|●|●| | | | | | | | | | | | |●|●| | | | | | |
1695 +|CommunicationPort| | | | | | | | | | | | |●|●|●|●|●| | | | | | | | |
1696 +|SlaveID| | | | | | | | | | | | |●|●|●|●|●| | | | | | | | |
1697 +|FunctionCode| | | | | | | | | | | | |●|●|●|●|●| | | | | | | | |
1698 +|SlaveAddress| | | | | | | | | | | | |●|●|●|●|●| | | | | | | | |
1699 +|Count| | | | | | | | | | | | |●|●|●|●|●| | | | | | | | |
1700 +|Data| | | | | | | | | | | | | | |●|●| | | | | | | | | |
1701 +|Done| |●|●|●|●| | | | | | | | | | | | | |●| | | | | | |
1702 +|Busy| |●|●|●|●| | | | | | | | | | | | | |●| | | | | | |
1703 +|InVelocity| |●|●|●|●| | | | | | | | | | | | | |●| | | | | | |
1704 +|Busy| |●|●|●|●| | | | | | | | | | | | | |●| | | | | | |
1705 +|Active| | | | | | | | | | | | | | |●|●| | | | | | | | | |
1706 +|CommandAborted|●|●|●|●|●| | | | | | | | | | | | |●|●| | | | | | |
1707 +|Error| | | | | | | | | | | | |●|●|●|●|●| | | | | | | | |
1708 +|ErrorID| | | | | | | | | | | | |●|●|●|●|●| | | | | | | | |
1706 1706  
1707 1707  **Variable Type Used**
1708 1708  
... ... @@ -1789,6 +1789,7 @@
1789 1789  |31A0H|No available gateway for COM2 Slave station return information: Unavailable gateway (Please refer to Modbus exception 0A)
1790 1790  |31A1H|COM2 indicates that no response was obtained from the target device. Slave station return information: The device is not in the network. (Please refer to Modbus exception 0B)
1791 1791  
1795 +
1792 1792  **Example**
1793 1793  
1794 1794  **Application example**
... ... @@ -1795,20 +1795,18 @@
1795 1795  
1796 1796  Set the COM2 communication parameters through the SD device.
1797 1797  
1798 -(% style="text-align:center" %)
1799 -[[image:1761119049914-901.png||height="377" width="533"]]
1802 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml2512\wps6.jpg]]
1800 1800  
1801 1801  Enable the function block and its Enable pin, send Modbus serial port master data and wait for the slave respond. Done indicates that the current instruction has been executed, Busy indicates that the serial port is busy, and Active indicates that the current instruction is running (waiting for data to be returned from the slave station).
1802 1802  
1803 -(% style="text-align:center" %)
1804 -[[image:1761120009429-879.png||height="611" width="571"]]
1806 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml2512\wps7.jpg]]
1805 1805  
1806 1806  
1807 -=== **SERIAL_WR** ===
1809 +1. **SERIAL_WR**
1808 1808  
1809 -SERIAL_WR - Custom protocol serial communication
1811 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml2512\wps8.png]]SERIAL_WR - Custom protocol serial communication
1810 1810  
1811 -[[image:1761120169708-257.png||height="307" width="271"]]
1813 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml2512\wps9.jpg]]
1812 1812  
1813 1813  This function block is a setting function block for user defined protocol serial port to send protocol frames. When the contact in front of Enable is turned ON. According to the communication port, sending data mapping address, sending data length, receiving data mapping address, and receiving data length set by the function block, the data frame is sent and waits for the data of the specified length to be returned.
1814 1814  
... ... @@ -1893,15 +1893,13 @@
1893 1893  )))
1894 1894  |3190H|COM2 receives data beyond the cache limit.
1895 1895  
1898 +
1896 1896  **Example**
1897 1897  
1898 1898  **Application example**
1899 1899  
1900 -* Set the COM2 communication parameters through the SD device.(((
1901 -(% style="text-align:center" %)
1902 -[[image:1761120267443-852.png||height="580" width="498"]]
1903 -)))
1903 +* Set the COM2 communication parameters through the SD device.
1904 1904  
1905 +[[image:file:///C:\Users\Administrator\AppData\Local\Temp\ksohtml2512\wps10.jpg]]
1905 1905  
1906 -
1907 1907  Enables the function block and the Enable pin of the function block, sends custom protocol data and waits for the slave to respond. Done indicates that the current instruction has been executed, Busy indicates that the serial port is busy, and Active indicates that the current instruction is running (waiting for data to be returned from the slave station).
1761118476244-253.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -47.4 KB
Content
1761118509428-681.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -47.4 KB
Content
1761119049914-901.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -41.9 KB
Content
1761120009429-879.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -67.4 KB
Content
1761120169708-257.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -41.9 KB
Content
1761120267443-852.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.Iris
Size
... ... @@ -1,1 +1,0 @@
1 -44.6 KB
Content