Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PIStudio. 1 User Manual.WebHome1 +PIStudio.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.Bob - Content
-
... ... @@ -4,27 +4,26 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - 1.**System data area (HSW): **A special register defined by the system.8 - 1.**Data storage area (HDW/HDX): **Users store user data.9 - 1.**System data area (HUW): **A special register defined by the system.10 - 1.**System Data (HAW)**: System register used for power-off save.11 - 1.**Recipe index area (RPW): **System register used for recipe index.7 +* **System data area (HSW): **A special register defined by the system. 8 +* **Data storage area (HDW/HDX): **Users store user data. 9 +* **System data area (HUW): **A special register defined by the system. 10 +* **System Data (HAW)**: System register used for power-off save. 11 +* **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 15 -1. Access as word with the prefix "HDW". 15 +* Access as word with the prefix "HDW". 16 +** HDW0 means the 1st word of system data area. HDW1 means the 2nd word of system data area. 17 +* Access as bit with the prefix "HDX". The number before "." i". The number before Access in bit with the prefix "HD". The number before Access in bit with the prefix "HDX". The number before "." indicates the number of the word. The number after "." indicates the bit number of the word. 18 +** HDX1020.12 means to access the system data area in bit mode, the specific location is the 13th bit of the 1020 word. 16 16 17 -* HDW0 means the 1st word of system data area. HDW1 means the 2nd word of system data area. 18 - 19 -(% start="2" %) 20 -1. Access as bit with the prefix "HDX". The number before "." i". The number before Access in bit with the prefix "HD". The number before Access in bit with the prefix "HDX". The number before "." indicates the number of the word. The number after "." indicates the bit number of the word. 21 - 22 -* HDX1020.12 means to access the system data area in bit mode, the specific location is the 13th bit of the 1020 word. 23 - 20 +(% class="box infomessage" %) 21 +((( 24 24 **✎Note:** 25 25 26 26 * Addresses in HDX are the bits from words in HDW, so be careful when using addresses. For example, HDX1020.12 is the 13th bit to access the 1020 word. The value of this bit is the same as that of the word accessed through HDW001020. The 13th bit of this word is actually the same bit as HDX1020.12. 27 27 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 +))) 28 28 29 29 = **Data storage area (HDW/HDX)** = 30 30 ... ... @@ -40,10 +40,13 @@ 40 40 1. Access as word, and serial number range is from HAW0 to HAW199999. 41 41 1. Access as bit, and serial number range is from HAX0.0 to HAX199999.15. 42 42 42 +(% class="box infomessage" %) 43 +((( 43 43 **✎Note:** 44 44 45 45 * HAW/HAX is power-down retention. The register of this type is able to save the data before the power-down. 46 46 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre 48 +))) 47 47 48 48 = **Recipe index area (RPW)** = 49 49 ... ... @@ -317,8 +317,14 @@ 317 317 |=(% style="width: 160px;" %)HSW857|(% style="width:282px" %)Permission in remote access (web page, mobile APP, cloud platform, etc.)|(% style="width:452px" %)((( 318 318 * =0: users could switch the screen, control the switch and update data in remote access. 319 319 * =1: users could only control function switch (only switch the screen), view data and switch state, but could not operate or update them. 320 -* =2: users could neither operate the screen switch, nor switch operation and data modification, only view.( ig series) 322 +* =2: users could neither operate the screen switch, nor switch operation and data modification, only view. (The ig series and 8000/9000 series with -R after system upgrade) 321 321 ))) 324 +|=(% style="width: 160px;" %)HSW860~~861|(% style="width:282px" %)Data partition remaining space|(% style="width:452px" %)Display the data partition remaining space, updated every minute, unit(**kB**) 325 +|=(% style="width: 160px;" %)HSW880|(% style="width:282px" %)Enable data partition remaining space|(% style="width:452px" %)((( 326 +~=1, able to view the data partition remaining space from HSW860~~861. 327 + 328 +~=Other value except 1, disable the viewing function. 329 +))) 322 322 |=(% style="width: 160px;" %)HSW881|(% style="width:282px" %)Storage of Record files|(% style="width:452px" %)((( 323 323 It is used for controlling saving alarm/data record files to U disk / SD card. 324 324 ... ... @@ -331,9 +331,11 @@ 331 331 * HDX882.1=0 SD card doesn't execute storage or storage finished. 332 332 * HDX882.1=1 SD card is reading data, don't remove SD card. 333 333 ))) 334 -|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter setup screen|(% style="width:452px" %)((( 335 -* = 0: Do not into setup screen 336 -* = 1: Enter setup screen 342 +|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 343 +* =0: Do not enter the network configuration interface 344 +* =1: Enter the system network configuration interface. 345 +** ig series HMI only supports to enter the system interface 346 + 337 337 ))) 338 338 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( 339 339 * = 0: displayed by object setting. ... ... @@ -502,6 +502,10 @@ 502 502 * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect. 503 503 * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time. 504 504 ))) 515 +|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)((( 516 +* =0: Use the curve width set by project default. 517 +* =1 to 10: use special register to set curve width. 518 +))) 505 505 |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file. 506 506 |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)((( 507 507 * =0: The auxiliary address is invalid. ... ... @@ -604,6 +604,174 @@ 604 604 * =1: Server connection is OK 605 605 ))) 606 606 |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger 621 +|=(% style="width: 160px;" %)((( 622 +HSW1762 623 +)))|(% colspan="1" rowspan="13" style="width:282px" %)((( 624 +Note: Valid when Ethernet2 of HMI is plugged into the network cable. 625 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 626 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 627 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 628 +④.IP related registers can be read and written (only static IP mode can be written). 629 +)))|(% style="width:452px" %)((( 630 +Ethernet2 Local IP address high byte 1 631 +))) 632 +|=(% style="width: 160px;" %)((( 633 +HSW1763 634 +)))|(% style="width:452px" %)((( 635 +Ethernet2 Local IP address high byte 2 636 +))) 637 +|=(% style="width: 160px;" %)((( 638 +HSW1764 639 +)))|(% style="width:452px" %)((( 640 +Ethernet2 Local IP address high byte 3 641 +))) 642 +|=(% style="width: 160px;" %)((( 643 +HSW1765 644 +)))|(% style="width:452px" %)((( 645 +Ethernet2 Local IP address high byte 4 646 +))) 647 +|=(% style="width: 160px;" %)((( 648 +HSW1766 649 +)))|(% style="width:452px" %)((( 650 +Ethernet2 Local mask IP address high byte 1 651 +))) 652 +|=(% style="width: 160px;" %)((( 653 +HSW1767 654 +)))|(% style="width:452px" %)((( 655 +Ethernet2 Local mask IP address high byte 2 656 +))) 657 +|=(% style="width: 160px;" %)((( 658 +HSW1768 659 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3 660 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4 661 +|=(% style="width: 160px;" %)((( 662 +HSW1770 663 +)))|(% style="width:452px" %)((( 664 +Ethernet2 Local gateway IP address high byte 1 665 +))) 666 +|=(% style="width: 160px;" %)((( 667 +HSW1771 668 +)))|(% style="width:452px" %)((( 669 +Ethernet2 Local gateway IP address high byte 2 670 +))) 671 +|=(% style="width: 160px;" %)((( 672 +HSW1772 673 +)))|(% style="width:452px" %)((( 674 +Ethernet2 Local gateway IP address high byte 3 675 +))) 676 +|=(% style="width: 160px;" %)((( 677 +HSW1773 678 +)))|(% style="width:452px" %)((( 679 +Ethernet2 Local gateway IP address high byte 4 680 +))) 681 +|=(% style="width: 160px;" %)((( 682 +HSW1774 683 +)))|(% style="width:452px" %)((( 684 +Ethernet2 Local Port Address 685 +))) 686 +|=(% style="width: 160px;" %)((( 687 +HSW1775 688 +)))|(% colspan="1" rowspan="6" style="width:282px" %)((( 689 +①Display the MAC code of Ethernet2 NIC 690 + 691 +(hexadecimal display) 692 + 693 +②Read-only mode, not modifiable 694 +)))|(% style="width:452px" %)((( 695 +Ethernet2 Local MAC code high byte 1 696 +))) 697 +|=(% style="width: 160px;" %)((( 698 +HSW1776 699 +)))|(% style="width:452px" %)((( 700 +Ethernet2 Local MAC code high byte 2 701 +))) 702 +|=(% style="width: 160px;" %)((( 703 +HSW1777 704 +)))|(% style="width:452px" %)((( 705 +Ethernet2 Local MAC code high byte 3 706 +))) 707 +|=(% style="width: 160px;" %)((( 708 +HSW1778 709 +)))|(% style="width:452px" %)((( 710 +Ethernet2 Local MAC code high byte 4 711 +))) 712 +|=(% style="width: 160px;" %)((( 713 +HSW1779 714 +)))|(% style="width:452px" %)((( 715 +Ethernet2 Local MAC code high byte 5 716 +))) 717 +|=(% style="width: 160px;" %)((( 718 +HSW1780 719 +)))|(% style="width:452px" %)((( 720 +Ethernet2 Local MAC code high byte 6 721 +))) 722 +|=(% style="width: 160px;" %)((( 723 +HSW1781 724 +)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 725 +①Display and modify DNS1 and DNS2 of Ethernet2 726 + 727 +②Related registers can be read and written mode (only static IP mode can be written) 728 +)))|(% style="width:452px" %)((( 729 +Ethernet2 Local DNS1 address high byte 1 730 +))) 731 +|=(% style="width: 160px;" %)((( 732 +HSW1782 733 +)))|(% style="width:452px" %)((( 734 +Ethernet2 Local DNS1 address high byte 2 735 +))) 736 +|=(% style="width: 160px;" %)((( 737 +HSW1783 738 +)))|(% style="width:452px" %)((( 739 +Ethernet2 Local DNS1 address high byte 3 740 +))) 741 +|=(% style="width: 160px;" %)((( 742 +HSW1784 743 +)))|(% style="width:452px" %)((( 744 +Ethernet2 Local DNS1 address high byte 4 745 +))) 746 +|=(% style="width: 160px;" %)((( 747 +HSW1785 748 +)))|(% style="width:452px" %)((( 749 +Ethernet2 Local DNS2 address high byte 1 750 +))) 751 +|=(% style="width: 160px;" %)((( 752 +HSW1786 753 +)))|(% style="width:452px" %)((( 754 +Ethernet2 Local DNS2 address high byte 2 755 +))) 756 +|=(% style="width: 160px;" %)((( 757 +HSW1787 758 +)))|(% style="width:452px" %)((( 759 +Ethernet2 Local DNS2 address high byte 3 760 +))) 761 +|=(% style="width: 160px;" %)((( 762 +HSW1788 763 +)))|(% style="width:452px" %)((( 764 +Ethernet2 Local DNS2 address high byte 4 765 +))) 766 +|=(% style="width: 160px;" %)((( 767 +HSW1789 768 +)))|(% colspan="1" style="width:282px" %)((( 769 +Display or set the dynamic or static IP mode of Ethernet2 770 +)))|(% style="width:452px" %)((( 771 +HSX1789.0 = 0, Static IP mode 772 + 773 +HSX1789.0 = 1, dynamic IP mode 774 +))) 775 +|=(% style="width: 160px;" %)((( 776 +HSW1790 777 +)))|(% colspan="1" style="width:282px" %)((( 778 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings 779 +)))|(% style="width:452px" %)((( 780 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 781 +))) 782 +|=(% style="width: 160px;" %)((( 783 +HSW1791 784 +)))|(% colspan="1" style="width:282px" %)((( 785 +Network status of the Ethernet2 connection server 786 +)))|(% style="width:452px" %)((( 787 +~= 0, connection to the server is abnormal = 1, connection to the server is normal 788 +))) 607 607 |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms. 608 608 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 609 609 * =0: db database ... ... @@ -629,14 +629,80 @@ 629 629 * =1: download firmware 630 630 * =2: enter the background 631 631 ))) 814 +|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)((( 815 +* =0: priority Ethernet 816 +* =1: priority WLAN 817 +* =2: priority 4G 818 +))) 819 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 820 +* =0: delete; 821 +* = Others: do not delete 822 +))) 823 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 824 +Monitor address is set during reset of reset switch, whether to cancel reset, 825 + 826 +* = 0: yes (default); 827 +* = 1: no 828 +))) 829 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 830 +Controls whether the button pops up when double-clicking or long pressing on record type table object 831 + 832 +* = 0: yes (default); 833 +* = 1: no 834 +))) 835 +|=(% style="width: 160px;" %)((( 836 +HSW1870 837 +)))|(% style="width:282px" %)((( 838 +Display or set the dynamic or static IP mode of Ethernet1 839 +)))|(% style="width:452px" %)((( 840 +HSX1870.0 = 0, Static IP mode 841 + 842 +HSX1870.0 = 1, dynamic IP mode 843 +))) 844 +|=(% style="width: 160px;" %)((( 845 +HSW1871 846 +)))|(% style="width:282px" %)((( 847 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1 848 +)))|(% style="width:452px" %)((( 849 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 850 +))) 851 +|=(% style="width: 160px;" %)((( 852 +HSW1872 853 +)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 854 +①Display and modify DNS1 and DNS2 of Ethernet1 855 + 856 +②Related registers can be read and written mode (only static IP mode can be written) 857 +)))|(% style="width:452px" %)((( 858 +Ethernet1 Local DNS1 address high byte 1 859 +))) 860 +|=(% style="width: 160px;" %)((( 861 +HSW1873 862 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2 863 +|=(% style="width: 160px;" %)((( 864 +HSW1874 865 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3 866 +|=(% style="width: 160px;" %)((( 867 +HSW1875 868 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4 869 +|=(% style="width: 160px;" %)((( 870 +HSW1876 871 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1 872 +|=(% style="width: 160px;" %)((( 873 +HSW1877 874 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2 875 +|=(% style="width: 160px;" %)((( 876 +HSW1878 877 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3 878 +|=(% style="width: 160px;" %)((( 879 +HSW1879 880 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 632 632 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 633 633 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 634 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable. 635 - 636 -1. If Ethernet settings is enabled in project parameters, this register displays the set value. 637 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP. 638 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set. 639 -1. 4. All IP registers of HMI are read-only. 883 +Note: Valid when Ethernet1 of HMI is plugged into the network cable. 884 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 885 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 886 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 887 +④.IP related registers can be read and written (only static IP mode can be written). 640 640 )))|(% style="width:452px" %)Local IP address high byte 1 641 641 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 642 642 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -651,9 +651,11 @@ 651 651 |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4 652 652 |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address 653 653 |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)((( 654 -Display sthe MAC code of thecurrent networkcard902 +①Display the MAC code of Ethernet1 NIC 655 655 656 -(Hexadecimal display) 904 +(hexadecimal display) 905 + 906 +②Read-only mode, not modifiable 657 657 )))|(% style="width:452px" %)Local MAC code high word 1 658 658 |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2 659 659 |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3 ... ... @@ -721,9 +721,9 @@ 721 721 * =2: Chinese 722 722 ))) 723 723 |=(% style="width: 160px;" %)HSW11756|(% style="width:282px" %)((( 724 - Set access permission restrictions974 +Access permission restrictions 725 725 726 - **(ig series)**976 +(ig series and** **8000/9000 series with -R after system upgrade) 727 727 )))|(% style="width:452px" %)((( 728 728 * =0: LAN or the external network both OK 729 729 * =1: Only LAN access ... ... @@ -743,10 +743,10 @@ 743 743 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 744 744 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 745 745 746 -== **Serial port communication configuration**==996 +== Serial port communication configuration == 747 747 748 748 (% class="table-bordered" %) 749 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 999 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 750 750 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( 751 751 * =0: RS232 752 752 * =1: RS485 ... ... @@ -776,10 +776,22 @@ 776 776 * =1: ODD 777 777 * =2: EVEN 778 778 ))) 779 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 780 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 781 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 782 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 1029 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 1030 +* Unit: ms. 1031 +* Range: 0 to 30000 1032 +))) 1033 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 1034 +* Unit: ms. 1035 +* Range: 0 to 30000 1036 +))) 1037 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 1038 +* Unit: times. 1039 +* Range: 0 to 100 1040 +))) 1041 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 1042 +* Unit: s. 1043 +* Range: 0 to 300 1044 +))) 783 783 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 784 784 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 785 785 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -812,10 +812,22 @@ 812 812 * =1: ODD 813 813 * =2: EVEN 814 814 ))) 815 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 816 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 817 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 818 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1077 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 1078 +* Unit: ms. 1079 +* Range: 0 to 30000 1080 +))) 1081 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 1082 +* Unit: ms. 1083 +* Range: 0 to 30000 1084 +))) 1085 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 1086 +* Unit: times. 1087 +* Range: 0 to 100 1088 +))) 1089 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 1090 +* Unit: s. 1091 +* Range: 0 to 30 1092 +))) 819 819 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 820 820 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 821 821 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -848,10 +848,22 @@ 848 848 * =1: ODD 849 849 * =2: EVEN 850 850 ))) 851 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 852 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 853 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 854 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1125 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 1126 +* Unit: ms. 1127 +* Range: 0 to 30000 1128 +))) 1129 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 1130 +* Unit: ms. 1131 +* Range: 0 to 30000 1132 +))) 1133 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 1134 +* Unit: times. 1135 +* Range: 0 to 100 1136 +))) 1137 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 1138 +* Unit: s. 1139 +* Range: 0 to 30 1140 +))) 855 855 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 856 856 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 857 857 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -882,10 +882,22 @@ 882 882 * =1: ODD 883 883 * =2: EVEN 884 884 ))) 885 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 886 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 887 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 888 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1171 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 1172 +* Unit: ms. 1173 +* Range: 0 to 30000 1174 +))) 1175 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 1176 +* Unit: ms. 1177 +* Range: 0 to 30000 1178 +))) 1179 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 1180 +* Unit: times. 1181 +* Range: 0 to 100 1182 +))) 1183 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 1184 +* Unit: s. 1185 +* Range: 0 to 30 1186 +))) 889 889 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 890 890 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 891 891 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -916,10 +916,22 @@ 916 916 * =1: ODD 917 917 * =2: EVEN 918 918 ))) 919 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 920 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 921 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 922 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1217 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 1218 +* Unit: ms. 1219 +* Range: 0 to 30000 1220 +))) 1221 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1222 +* Unit: ms. 1223 +* Range: 0 to 30000 1224 +))) 1225 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1226 +* Unit: times. 1227 +* Range: 0 to 100 1228 +))) 1229 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1230 +* Unit: s. 1231 +* Range: 0 to 30 1232 +))) 923 923 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 924 924 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 925 925 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -949,29 +949,48 @@ 949 949 * =1: ODD 950 950 * =2: EVEN 951 951 ))) 952 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 953 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 954 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 955 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1262 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1263 +* Unit: ms. 1264 +* Range: 0 to 30000 1265 +))) 1266 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1267 +* Unit: ms. 1268 +* Range: 0 to 30000 1269 +))) 1270 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1271 +* Unit: times. 1272 +* Range: 0 to 100 1273 +))) 1274 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1275 +* Unit: s. 1276 +* Range: 0 to 30 1277 +))) 956 956 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 957 957 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 958 958 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 959 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1281 +Unit: K, the baud rate must be an integer. 1282 + 1283 +For example, when the baud rate required is 250000, just enter 250. 960 960 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 961 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1285 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1286 +Unit: K, the baud rate must be an integer. 962 962 963 -== **Ethernet communication configuration** == 1288 +For example, when the baud rate required is 250000, just enter 250. 1289 +))) 964 964 1291 +== Ethernet communication configuration == 1292 + 965 965 (% class="table-bordered" %) 966 -| =(% style="width:;" %)**No.**|=(% style="width:;" %)**Function**|=(% style="width:;" %)**Address**|=(% style="width:;" %)**Description**1294 +|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description** 967 967 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 968 968 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2 969 969 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3 970 970 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4 971 971 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number 972 -|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)((( 973 -* =2 TCP 974 -* =3 UDP 1300 +|(% style="width:220px" %)HSW11009|(% style="width:336px" %)((( 1301 +~=2 TCP 1302 + 1303 +~=3 UDP 975 975 ))) 976 976 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved 977 977 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -979,9 +979,10 @@ 979 979 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3 980 980 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4 981 981 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number 982 -|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)((( 983 -* =2 TCP 984 -* =3 UDP 1311 +|(% style="width:220px" %)HSW11016|(% style="width:336px" %)((( 1312 +~=2 TCP 1313 + 1314 +~=3 UDP 985 985 ))) 986 986 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved 987 987 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)… ... ... @@ -990,16 +990,22 @@ 990 990 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3 991 991 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4 992 992 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number 993 -|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 1323 +|(% style="width:220px" %)HSW11226|(% style="width:336px" %)((( 1324 +~=2 TCP; 1325 + 1326 +~=3 UDP 1327 +))) 994 994 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 995 995 996 -(% class="wikigeneratedid" %) 1330 +(% class="box infomessage" %) 1331 +((( 997 997 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1333 +))) 998 998 999 -== **Communication control**==1335 +== Communication control == 1000 1000 1001 1001 (% class="table-bordered" %) 1002 -|(% style="width:135px" %)**Communication No.**|(% style="width:102px" %)**Station No.**|(% style="width:185px" %)**Control bit**|(% style="width:191px" %)**Communication lamp**|(% style="width:271px" %)**Description** 1338 +|=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description** 1003 1003 |(% colspan="1" rowspan="16" style="width:135px" %)1|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX550.0~HSX550.15|(% style="width:191px" %)HSX558.0~HSX558.15|(% rowspan="160" style="width:271px" %)Communication number refers to the number in "Communication Port Configuration". A number provides 256 device station numbers. Each station number corresponds to a communication control bit and a communication indicator bit. Registers HSX550.0 to HSX805.15 are used to control the station numbers from 0 to 127, and registers HSX1150.0 to HSX1405.15 are used to control station numbers 128 to 255. 1004 1004 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX551.0~HSX551.15|(% style="width:191px" %)HSX559.0~HSX559.15 1005 1005 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX552.0~HSX552.15|(% style="width:191px" %)HSX560.0~HSX560.15