... ... @@ -1,1 +1,1 @@ 1 -PIStudio. 1 User Manual.WebHome1 +PIStudio.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. admin1 +XWiki.Stone - Content
-
... ... @@ -12,19 +12,18 @@ 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 15 -1. Access as word with the prefix "HDW". 15 +* Access as word with the prefix "HDW". 16 +** HDW0 means the 1st word of system data area. HDW1 means the 2nd word of system data area. 17 +* Access as bit with the prefix "HDX". The number before "." i". The number before Access in bit with the prefix "HD". The number before Access in bit with the prefix "HDX". The number before "." indicates the number of the word. The number after "." indicates the bit number of the word. 18 +** HDX1020.12 means to access the system data area in bit mode, the specific location is the 13th bit of the 1020 word. 16 16 17 -* HDW0 means the 1st word of system data area. HDW1 means the 2nd word of system data area. 18 - 19 -(% start="2" %) 20 -1. Access as bit with the prefix "HDX". The number before "." i". The number before Access in bit with the prefix "HD". The number before Access in bit with the prefix "HDX". The number before "." indicates the number of the word. The number after "." indicates the bit number of the word. 21 - 22 -* HDX1020.12 means to access the system data area in bit mode, the specific location is the 13th bit of the 1020 word. 23 - 20 +(% class="box infomessage" %) 21 +((( 24 24 **✎Note:** 25 25 26 26 * Addresses in HDX are the bits from words in HDW, so be careful when using addresses. For example, HDX1020.12 is the 13th bit to access the 1020 word. The value of this bit is the same as that of the word accessed through HDW001020. The 13th bit of this word is actually the same bit as HDX1020.12. 27 27 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 +))) 28 28 29 29 = **Data storage area (HDW/HDX)** = 30 30 ... ... @@ -40,10 +40,13 @@ 40 40 1. Access as word, and serial number range is from HAW0 to HAW199999. 41 41 1. Access as bit, and serial number range is from HAX0.0 to HAX199999.15. 42 42 42 +(% class="box infomessage" %) 43 +((( 43 43 **✎Note:** 44 44 45 45 * HAW/HAX is power-down retention. The register of this type is able to save the data before the power-down. 46 46 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre 48 +))) 47 47 48 48 = **Recipe index area (RPW)** = 49 49 ... ... @@ -317,8 +317,14 @@ 317 317 |=(% style="width: 160px;" %)HSW857|(% style="width:282px" %)Permission in remote access (web page, mobile APP, cloud platform, etc.)|(% style="width:452px" %)((( 318 318 * =0: users could switch the screen, control the switch and update data in remote access. 319 319 * =1: users could only control function switch (only switch the screen), view data and switch state, but could not operate or update them. 320 -* =2: users could neither operate the screen switch, nor switch operation and data modification, only view.( ig series) 322 +* =2: users could neither operate the screen switch, nor switch operation and data modification, only view. (The ig series and 8000/9000 series with -R after system upgrade) 321 321 ))) 324 +|=(% style="width: 160px;" %)HSW860~~861|(% style="width:282px" %)Data partition remaining space|(% style="width:452px" %)Display the data partition remaining space, updated every minute, unit(**kB**) 325 +|=(% style="width: 160px;" %)HSW880|(% style="width:282px" %)Enable data partition remaining space|(% style="width:452px" %)((( 326 +~=1, able to view the data partition remaining space from HSW860~~861. 327 + 328 +~=Other value except 1, disable the viewing function. 329 +))) 322 322 |=(% style="width: 160px;" %)HSW881|(% style="width:282px" %)Storage of Record files|(% style="width:452px" %)((( 323 323 It is used for controlling saving alarm/data record files to U disk / SD card. 324 324 ... ... @@ -331,9 +331,11 @@ 331 331 * HDX882.1=0 SD card doesn't execute storage or storage finished. 332 332 * HDX882.1=1 SD card is reading data, don't remove SD card. 333 333 ))) 334 -|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter setup screen|(% style="width:452px" %)((( 335 -* = 0: Do not into setup screen 336 -* = 1: Enter setup screen 342 +|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 343 +* =0: Do not enter the network configuration interface 344 +* =1: Enter the system network configuration interface. 345 +** ig series HMI only supports to enter the system interface 346 + 337 337 ))) 338 338 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( 339 339 * = 0: displayed by object setting. ... ... @@ -502,6 +502,10 @@ 502 502 * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect. 503 503 * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time. 504 504 ))) 515 +|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)((( 516 +* =0: Use the curve width set by project default. 517 +* =1 to 10: use special register to set curve width. 518 +))) 505 505 |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file. 506 506 |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)((( 507 507 * =0: The auxiliary address is invalid. ... ... @@ -629,6 +629,22 @@ 629 629 * =1: download firmware 630 630 * =2: enter the background 631 631 ))) 646 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 647 +* =1, delete; 648 +* = Others, do not delete 649 +))) 650 +|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 651 +Monitor address is set during reset of reset switch, whether to cancel reset, 652 + 653 +* = 0, yes (default); 654 +* = 1, no 655 +))) 656 +|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 657 +Controls whether the button pops up when double-clicking or long pressing on record type table object 658 + 659 +* = 0, yes (default); 660 +* = 1, no 661 +))) 632 632 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 633 633 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 634 634 **✎Note: **Only valid when the HMI is plugged into the Ethernet cable. ... ... @@ -721,9 +721,9 @@ 721 721 * =2: Chinese 722 722 ))) 723 723 |=(% style="width: 160px;" %)HSW11756|(% style="width:282px" %)((( 724 - Set access permission restrictions754 +Access permission restrictions 725 725 726 - **(ig series)**756 +(ig series and** **8000/9000 series with -R after system upgrade) 727 727 )))|(% style="width:452px" %)((( 728 728 * =0: LAN or the external network both OK 729 729 * =1: Only LAN access ... ... @@ -746,7 +746,7 @@ 746 746 == **Serial port communication configuration** == 747 747 748 748 (% class="table-bordered" %) 749 -|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 779 +|=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 750 750 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( 751 751 * =0: RS232 752 752 * =1: RS485 ... ... @@ -776,10 +776,22 @@ 776 776 * =1: ODD 777 777 * =2: EVEN 778 778 ))) 779 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 780 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 781 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 782 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 809 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 810 +* Unit: ms. 811 +* Range: 0 to 30000 812 +))) 813 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 814 +* Unit: ms. 815 +* Range: 0 to 30000 816 +))) 817 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 818 +* Unit: times. 819 +* Range: 0 to 100 820 +))) 821 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 822 +* Unit: s. 823 +* Range: 0 to 300 824 +))) 783 783 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 784 784 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 785 785 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -812,10 +812,22 @@ 812 812 * =1: ODD 813 813 * =2: EVEN 814 814 ))) 815 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 816 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 817 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 818 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 857 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 858 +* Unit: ms. 859 +* Range: 0 to 30000 860 +))) 861 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 862 +* Unit: ms. 863 +* Range: 0 to 30000 864 +))) 865 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 866 +* Unit: times. 867 +* Range: 0 to 100 868 +))) 869 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 870 +* Unit: s. 871 +* Range: 0 to 30 872 +))) 819 819 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 820 820 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 821 821 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -848,10 +848,22 @@ 848 848 * =1: ODD 849 849 * =2: EVEN 850 850 ))) 851 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 852 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 853 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 854 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 905 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 906 +* Unit: ms. 907 +* Range: 0 to 30000 908 +))) 909 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 910 +* Unit: ms. 911 +* Range: 0 to 30000 912 +))) 913 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 914 +* Unit: times. 915 +* Range: 0 to 100 916 +))) 917 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 918 +* Unit: s. 919 +* Range: 0 to 30 920 +))) 855 855 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 856 856 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 857 857 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -882,10 +882,22 @@ 882 882 * =1: ODD 883 883 * =2: EVEN 884 884 ))) 885 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 886 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 887 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 888 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 951 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 952 +* Unit: ms. 953 +* Range: 0 to 30000 954 +))) 955 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 956 +* Unit: ms. 957 +* Range: 0 to 30000 958 +))) 959 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 960 +* Unit: times. 961 +* Range: 0 to 100 962 +))) 963 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 964 +* Unit: s. 965 +* Range: 0 to 30 966 +))) 889 889 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 890 890 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 891 891 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -916,10 +916,22 @@ 916 916 * =1: ODD 917 917 * =2: EVEN 918 918 ))) 919 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 920 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 921 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 922 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 997 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 998 +* Unit: ms. 999 +* Range: 0 to 30000 1000 +))) 1001 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1002 +* Unit: ms. 1003 +* Range: 0 to 30000 1004 +))) 1005 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1006 +* Unit: times. 1007 +* Range: 0 to 100 1008 +))) 1009 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1010 +* Unit: s. 1011 +* Range: 0 to 30 1012 +))) 923 923 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 924 924 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 925 925 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -949,17 +949,35 @@ 949 949 * =1: ODD 950 950 * =2: EVEN 951 951 ))) 952 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 953 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 954 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 955 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1042 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1043 +* Unit: ms. 1044 +* Range: 0 to 30000 1045 +))) 1046 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1047 +* Unit: ms. 1048 +* Range: 0 to 30000 1049 +))) 1050 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1051 +* Unit: times. 1052 +* Range: 0 to 100 1053 +))) 1054 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1055 +* Unit: s. 1056 +* Range: 0 to 30 1057 +))) 956 956 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 957 957 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 958 958 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 959 -Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1061 +Unit: K, the baud rate must be an integer. 1062 + 1063 +For example, when the baud rate required is 250000, just enter 250. 960 960 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 961 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1065 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1066 +Unit: K, the baud rate must be an integer. 962 962 1068 +For example, when the baud rate required is 250000, just enter 250. 1069 +))) 1070 + 963 963 == **Ethernet communication configuration** == 964 964 965 965 (% class="table-bordered" %) ... ... @@ -993,13 +993,15 @@ 993 993 |(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 994 994 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 995 995 996 -(% class="wikigeneratedid" %) 1104 +(% class="box infomessage" %) 1105 +((( 997 997 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1107 +))) 998 998 999 999 == **Communication control** == 1000 1000 1001 1001 (% class="table-bordered" %) 1002 -|(% style="width:135px" %)**Communication No.**|(% style="width:102px" %)**Station No.**|(% style="width:185px" %)**Control bit**|(% style="width:191px" %)**Communication lamp**|(% style="width:271px" %)**Description** 1112 +|=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description** 1003 1003 |(% colspan="1" rowspan="16" style="width:135px" %)1|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX550.0~HSX550.15|(% style="width:191px" %)HSX558.0~HSX558.15|(% rowspan="160" style="width:271px" %)Communication number refers to the number in "Communication Port Configuration". A number provides 256 device station numbers. Each station number corresponds to a communication control bit and a communication indicator bit. Registers HSX550.0 to HSX805.15 are used to control the station numbers from 0 to 127, and registers HSX1150.0 to HSX1405.15 are used to control station numbers 128 to 255. 1004 1004 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX551.0~HSX551.15|(% style="width:191px" %)HSX559.0~HSX559.15 1005 1005 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX552.0~HSX552.15|(% style="width:191px" %)HSX560.0~HSX560.15