Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 10.1
edited by Theodore Xu
on 2022/12/16 10:09
Change comment: There is no comment for this version
To version 31.1
edited by Mora Zhou
on 2023/11/21 16:19
Change comment: There is no comment for this version

Summary

Details

Page properties
Title
... ... @@ -1,1 +1,1 @@
1 -12 HMI internal registers
1 +13.HMI Internal Registers
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Mora
Content
... ... @@ -25,6 +25,11 @@
25 25  * The address of the bit address HDX is with a decimal point while word addresses are integers.
26 26  )))
27 27  
28 += Address ranges table =
29 +
30 +(% style="text-align:center" %)
31 +[[image:6.png]]
32 +
28 28  = **Data storage area (HDW/HDX)** =
29 29  
30 30  It is used to save the temporary data of project.
... ... @@ -51,17 +51,20 @@
51 51  
52 52  It is system recipe data power-off save register. The range is from RPW000000 to RPW990450.
53 53  
59 +(% class="box infomessage" %)
60 +(((
54 54  **✎Note:**
55 55  
56 56  * RPW is power-down retention. The register of this type is able to save the data before the power-down.
57 57  * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre
65 +)))
58 58  
59 59  = **Single user data area (HUW/HUX)** =
60 60  
61 61  It is used for system special registers (reserved by system).
62 62  
63 -1. Access as word, and serial number range is from HUW0 to HUW199999.
64 -1. Access as bit, and serial number range is from HUX0.0 to HUX199999.15.
71 +1. Access as word, and serial number range is from HUW0 to HUW1599.
72 +1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15.
65 65  
66 66  **✎Note:**
67 67  
... ... @@ -135,8 +135,8 @@
135 135  (% class="table-bordered" style="width:1024px" %)
136 136  |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description**
137 137  |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported)
138 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000
139 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80
146 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000
147 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80
140 140  |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms
141 141  |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)(((
142 142  * =0: Enable.
... ... @@ -150,7 +150,7 @@
150 150  )))
151 151  |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed)
152 152  |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm
153 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)(((
161 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)(((
154 154  * =0: Enable
155 155  * =1: Disable
156 156  )))
... ... @@ -175,6 +175,7 @@
175 175  * =5: Friday.
176 176  * =6: Saturday.
177 177  )))
186 +|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1.
178 178  |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)(((
179 179  Whether the Script is read through
180 180  
... ... @@ -241,8 +241,8 @@
241 241  * =2: HSX521.1=1, delete all trend graph.
242 242  * =4: HSX521.2=1, delete all alarms.
243 243  * =16: HSX521.4=1, delete history XY plot.
244 -* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting).
245 -* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting).
253 +* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting).
254 +* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting).
246 246  )))
247 247  |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)(((
248 248  * =0: No operation
... ... @@ -450,7 +450,7 @@
450 450  Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms.
451 451  
452 452  * When the set value is greater than 1000, the value is 1000.
453 -* When the set value is greater than 1000, it changes to the default value 300
462 +* When the set value is lower than 40, it changes to the default value 300
454 454  )))
455 455  |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)(((
456 456  After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2.
... ... @@ -485,6 +485,8 @@
485 485  * =0, Default value
486 486  * =1, Release the alarm generated before the last power-down when starting up
487 487  )))
497 +|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
498 +|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
488 488  |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
489 489  * =0, Disable
490 490  * =1, Enable
... ... @@ -591,6 +591,9 @@
591 591  * =0: Server connection exception
592 592  * =1: Server connection is OK
593 593  )))
605 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)(((
606 +Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
607 +)))
594 594  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
595 595  |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2
596 596  |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -618,10 +618,180 @@
618 618  * =1: Server connection is OK
619 619  )))
620 620  |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger
635 +|=(% style="width: 160px;" %)(((
636 +HSW1762
637 +)))|(% colspan="1" rowspan="13" style="width:282px" %)(((
638 +Note: Valid when Ethernet2 of HMI is plugged into the network cable.
639 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
640 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
641 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
642 +④.IP related registers can be read and written (only static IP mode can be written).
643 +)))|(% style="width:452px" %)(((
644 +Ethernet2 Local IP address high byte 1
645 +)))
646 +|=(% style="width: 160px;" %)(((
647 +HSW1763
648 +)))|(% style="width:452px" %)(((
649 +Ethernet2 Local IP address high byte 2
650 +)))
651 +|=(% style="width: 160px;" %)(((
652 +HSW1764
653 +)))|(% style="width:452px" %)(((
654 +Ethernet2 Local IP address high byte 3
655 +)))
656 +|=(% style="width: 160px;" %)(((
657 +HSW1765
658 +)))|(% style="width:452px" %)(((
659 +Ethernet2 Local IP address high byte 4
660 +)))
661 +|=(% style="width: 160px;" %)(((
662 +HSW1766
663 +)))|(% style="width:452px" %)(((
664 +Ethernet2 Local mask IP address high byte 1
665 +)))
666 +|=(% style="width: 160px;" %)(((
667 +HSW1767
668 +)))|(% style="width:452px" %)(((
669 +Ethernet2 Local mask IP address high byte 2
670 +)))
671 +|=(% style="width: 160px;" %)(((
672 +HSW1768
673 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3
674 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4
675 +|=(% style="width: 160px;" %)(((
676 +HSW1770
677 +)))|(% style="width:452px" %)(((
678 +Ethernet2 Local gateway IP address high byte 1
679 +)))
680 +|=(% style="width: 160px;" %)(((
681 +HSW1771
682 +)))|(% style="width:452px" %)(((
683 +Ethernet2 Local gateway IP address high byte 2
684 +)))
685 +|=(% style="width: 160px;" %)(((
686 +HSW1772
687 +)))|(% style="width:452px" %)(((
688 +Ethernet2 Local gateway IP address high byte 3
689 +)))
690 +|=(% style="width: 160px;" %)(((
691 +HSW1773
692 +)))|(% style="width:452px" %)(((
693 +Ethernet2 Local gateway IP address high byte 4
694 +)))
695 +|=(% style="width: 160px;" %)(((
696 +HSW1774
697 +)))|(% style="width:452px" %)(((
698 +Ethernet2 Local Port Address
699 +)))
700 +|=(% style="width: 160px;" %)(((
701 +HSW1775
702 +)))|(% colspan="1" rowspan="6" style="width:282px" %)(((
703 +①Display the MAC code of Ethernet2 NIC
704 +
705 +(hexadecimal display)
706 +
707 +②Read-only mode, not modifiable
708 +)))|(% style="width:452px" %)(((
709 +Ethernet2 Local MAC code high byte 1
710 +)))
711 +|=(% style="width: 160px;" %)(((
712 +HSW1776
713 +)))|(% style="width:452px" %)(((
714 +Ethernet2 Local MAC code high byte 2
715 +)))
716 +|=(% style="width: 160px;" %)(((
717 +HSW1777
718 +)))|(% style="width:452px" %)(((
719 +Ethernet2 Local MAC code high byte 3
720 +)))
721 +|=(% style="width: 160px;" %)(((
722 +HSW1778
723 +)))|(% style="width:452px" %)(((
724 +Ethernet2 Local MAC code high byte 4
725 +)))
726 +|=(% style="width: 160px;" %)(((
727 +HSW1779
728 +)))|(% style="width:452px" %)(((
729 +Ethernet2 Local MAC code high byte 5
730 +)))
731 +|=(% style="width: 160px;" %)(((
732 +HSW1780
733 +)))|(% style="width:452px" %)(((
734 +Ethernet2 Local MAC code high byte 6
735 +)))
736 +|=(% style="width: 160px;" %)(((
737 +HSW1781
738 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
739 +①Display and modify DNS1 and DNS2 of Ethernet2
740 +
741 +②Related registers can be read and written mode (only static IP mode can be written)
742 +)))|(% style="width:452px" %)(((
743 +Ethernet2 Local DNS1 address high byte 1
744 +)))
745 +|=(% style="width: 160px;" %)(((
746 +HSW1782
747 +)))|(% style="width:452px" %)(((
748 +Ethernet2 Local DNS1 address high byte 2
749 +)))
750 +|=(% style="width: 160px;" %)(((
751 +HSW1783
752 +)))|(% style="width:452px" %)(((
753 +Ethernet2 Local DNS1 address high byte 3
754 +)))
755 +|=(% style="width: 160px;" %)(((
756 +HSW1784
757 +)))|(% style="width:452px" %)(((
758 +Ethernet2 Local DNS1 address high byte 4
759 +)))
760 +|=(% style="width: 160px;" %)(((
761 +HSW1785
762 +)))|(% style="width:452px" %)(((
763 +Ethernet2 Local DNS2 address high byte 1
764 +)))
765 +|=(% style="width: 160px;" %)(((
766 +HSW1786
767 +)))|(% style="width:452px" %)(((
768 +Ethernet2 Local DNS2 address high byte 2
769 +)))
770 +|=(% style="width: 160px;" %)(((
771 +HSW1787
772 +)))|(% style="width:452px" %)(((
773 +Ethernet2 Local DNS2 address high byte 3
774 +)))
775 +|=(% style="width: 160px;" %)(((
776 +HSW1788
777 +)))|(% style="width:452px" %)(((
778 +Ethernet2 Local DNS2 address high byte 4
779 +)))
780 +|=(% style="width: 160px;" %)(((
781 +HSW1789
782 +)))|(% colspan="1" style="width:282px" %)(((
783 +Display or set the dynamic or static IP mode of Ethernet2
784 +)))|(% style="width:452px" %)(((
785 +HSX1789.0 = 0, Static IP mode
786 +
787 +HSX1789.0 = 1, dynamic IP mode
788 +)))
789 +|=(% style="width: 160px;" %)(((
790 +HSW1790
791 +)))|(% colspan="1" style="width:282px" %)(((
792 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings
793 +)))|(% style="width:452px" %)(((
794 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
795 +)))
796 +|=(% style="width: 160px;" %)(((
797 +HSW1791
798 +)))|(% colspan="1" style="width:282px" %)(((
799 +Network status of the Ethernet2 connection server
800 +)))|(% style="width:452px" %)(((
801 +~= 0, connection to the server is abnormal = 1, connection to the server is normal
802 +)))
621 621  |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms.
622 622  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
623 623  * =0: db database
624 624  * =1: CSV
807 +
808 +(Only valid for script function DbToCsvFile)
625 625  )))
626 626  |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
627 627  * =0: use the old high-low word conversion (default)
... ... @@ -644,11 +644,11 @@
644 644  * =2: enter the background
645 645  )))
646 646  |=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
647 -* =0: priority  Ethernet
831 +* =0: priority Ethernet
648 648  * =1: priority WLAN
649 649  * =2: priority 4G
650 650  )))
651 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
835 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
652 652  * =0: delete;
653 653  * = Others: do not delete
654 654  )))
... ... @@ -664,14 +664,75 @@
664 664  * = 0: yes (default);
665 665  * = 1: no
666 666  )))
851 +|=(% style="width: 160px;" %)(((
852 +HSW1869
853 +)))|(% style="width:282px" %)(((
854 +Dynamic screensaver countdown
855 +)))|(% style="width:452px" %)(((
856 +Countdown to enter dynamic screensaver effect, unit (S)
857 +)))
858 +|=(% style="width: 160px;" %)(((
859 +HSW1870
860 +)))|(% style="width:282px" %)(((
861 +Display or set the dynamic or static IP mode of Ethernet1
862 +)))|(% style="width:452px" %)(((
863 +HSX1870.0 = 0, Static IP mode
864 +
865 +HSX1870.0 = 1, dynamic IP mode
866 +)))
867 +|=(% style="width: 160px;" %)(((
868 +HSW1871
869 +)))|(% style="width:282px" %)(((
870 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1
871 +)))|(% style="width:452px" %)(((
872 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
873 +)))
874 +|=(% style="width: 160px;" %)(((
875 +HSW1872
876 +)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
877 +①Display and modify DNS1 and DNS2 of Ethernet1
878 +
879 +②Related registers can be read and written mode (only static IP mode can be written)
880 +)))|(% style="width:452px" %)(((
881 +Ethernet1 Local DNS1 address high byte 1
882 +)))
883 +|=(% style="width: 160px;" %)(((
884 +HSW1873
885 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2
886 +|=(% style="width: 160px;" %)(((
887 +HSW1874
888 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3
889 +|=(% style="width: 160px;" %)(((
890 +HSW1875
891 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4
892 +|=(% style="width: 160px;" %)(((
893 +HSW1876
894 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1
895 +|=(% style="width: 160px;" %)(((
896 +HSW1877
897 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2
898 +|=(% style="width: 160px;" %)(((
899 +HSW1878
900 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3
901 +|=(% style="width: 160px;" %)(((
902 +HSW1879
903 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
904 +|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)(((
905 +* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval)
906 +* =Others: not refresh
907 +)))
908 +|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data  |(% style="width:452px" %)(((
909 +* =1, not clear screen cache when switch language
910 +* =2, trigger clear cache of all screens for once time
911 +* =3, always clear cache of all screen data
912 +)))
667 667  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
668 668  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
669 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
670 -
671 -1. If Ethernet settings is enabled in project parameters, this register displays the set value.
672 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP.
673 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set.
674 -1. 4. All IP registers of HMI are read-only.
915 +Note: Valid when Ethernet1 of HMI is plugged into the network cable.
916 +① When the Ethernet setting is enabled in the project parameters, this register displays the set value.
917 +② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
918 +③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
919 +④ IP related registers can be read and written (only static IP mode can be written).
675 675  )))|(% style="width:452px" %)Local IP address high byte 1
676 676  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
677 677  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -686,9 +686,11 @@
686 686  |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4
687 687  |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address
688 688  |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)(((
689 -Displays the MAC code of the current network card
934 +Display the MAC code of Ethernet1 NIC
690 690  
691 -(Hexadecimal display)
936 +(hexadecimal display)
937 +
938 +②Read-only mode, not modifiable
692 692  )))|(% style="width:452px" %)Local MAC code high word 1
693 693  |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2
694 694  |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3
... ... @@ -695,7 +695,7 @@
695 695  |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
696 696  |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
697 697  |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
698 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
945 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
699 699  |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
700 700  |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
701 701  |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
... ... @@ -763,6 +763,7 @@
763 763  * =0: LAN or the external network both OK
764 764  * =1: Only LAN access
765 765  * =2: Only external network can access
1013 +* =3: Close the functions
766 766  )))
767 767  |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)(((
768 768  * =0: Disabled
... ... @@ -777,7 +777,34 @@
777 777  )))
778 778  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
779 779  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1028 +|=(% style="width: 160px;" %)(((
1029 +HSW11762
1030 +)))|(% style="width:282px" %)(((
1031 +Dynamic screensaver control address
1032 +)))|(% style="width:452px" %)(((
1033 +HSX11762.0=0, initialize with project configuration;
780 780  
1035 +HSX11762.0=1, initialize with special register configuration;
1036 +
1037 +HSX11762.1=0, disable dynamic screensaver;
1038 +
1039 +HSX11762.1=1, enable dynamic screensaver
1040 +)))
1041 +|=(% style="width: 160px;" %)(((
1042 +HSW11763
1043 +)))|(% style="width:282px" %)(((
1044 +Waiting time to enter the dynamic screensaver
1045 +)))|(% style="width:452px" %)(((
1046 +Waiting time when the screen is not operated, range 1~~720 minutes
1047 +)))
1048 +|=(% style="width: 160px;" %)(((
1049 +HSW11764
1050 +)))|(% style="width:282px" %)(((
1051 +Animated screensaver animation type
1052 +)))|(% style="width:452px" %)(((
1053 +~=0: Raster,=1: Blinds,=2: Bubble
1054 +)))
1055 +
781 781  == Serial port communication configuration ==
782 782  
783 783  (% class="table-bordered" %)
6.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.Mora
Size
... ... @@ -1,0 +1,1 @@
1 +20.1 KB
Content