Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
From version 10.1
edited by Theodore Xu
on 2022/12/16 10:09
on 2022/12/16 10:09
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1 2HMIinternalregisters1 +13.HMI Internal Registers - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.Mora - Content
-
... ... @@ -25,6 +25,11 @@ 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 26 ))) 27 27 28 += Address ranges table = 29 + 30 +(% style="text-align:center" %) 31 +[[image:6.png]] 32 + 28 28 = **Data storage area (HDW/HDX)** = 29 29 30 30 It is used to save the temporary data of project. ... ... @@ -51,21 +51,27 @@ 51 51 52 52 It is system recipe data power-off save register. The range is from RPW000000 to RPW990450. 53 53 59 +(% class="box infomessage" %) 60 +((( 54 54 **✎Note:** 55 55 56 56 * RPW is power-down retention. The register of this type is able to save the data before the power-down. 57 57 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre 65 +))) 58 58 59 59 = **Single user data area (HUW/HUX)** = 60 60 61 61 It is used for system special registers (reserved by system). 62 62 63 -1. Access as word, and serial number range is from HUW0 to HUW199 999.64 -1. Access as bit, and serial number range is from HUX0.0 to HUX199 999.15.71 +1. Access as word, and serial number range is from HUW0 to HUW1599. 72 +1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15. 65 65 74 +(% class="box infomessage" %) 75 +((( 66 66 **✎Note:** 67 67 68 68 * HUW/HUX is a system special register, so please check the system special register list during use. Please use the address specified in the table and do not use the address which is not mentioned in the table. 79 +))) 69 69 70 70 (% class="table-bordered" %) 71 71 |=**Special register address**|=**Description**|=**Function** ... ... @@ -135,8 +135,8 @@ 135 135 (% class="table-bordered" style="width:1024px" %) 136 136 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description** 137 137 |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported) 138 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000 139 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80 149 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000 150 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80 140 140 |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms 141 141 |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)((( 142 142 * =0: Enable. ... ... @@ -150,7 +150,7 @@ 150 150 ))) 151 151 |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed) 152 152 |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm 153 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)(((164 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)((( 154 154 * =0: Enable 155 155 * =1: Disable 156 156 ))) ... ... @@ -175,6 +175,7 @@ 175 175 * =5: Friday. 176 176 * =6: Saturday. 177 177 ))) 189 +|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1. 178 178 |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)((( 179 179 Whether the Script is read through 180 180 ... ... @@ -241,8 +241,8 @@ 241 241 * =2: HSX521.1=1, delete all trend graph. 242 242 * =4: HSX521.2=1, delete all alarms. 243 243 * =16: HSX521.4=1, delete history XY plot. 244 -* =32: HSX521.5=1, delete data records in SD card or flash dis h;(Please make a setting which is saved to flash disk or SD card in project setting).245 -* =64: HSX521.6=1, delete alarms records in SD card or flash dis h; (Please make a setting which is saved to flash disk or SD card in project setting).256 +* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting). 257 +* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting). 246 246 ))) 247 247 |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)((( 248 248 * =0: No operation ... ... @@ -450,7 +450,7 @@ 450 450 Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms. 451 451 452 452 * When the set value is greater than 1000, the value is 1000. 453 -* When the set value is greater than1000, it changes to the default value 300465 +* When the set value is lower than 40, it changes to the default value 300 454 454 ))) 455 455 |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)((( 456 456 After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2. ... ... @@ -485,6 +485,8 @@ 485 485 * =0, Default value 486 486 * =1, Release the alarm generated before the last power-down when starting up 487 487 ))) 500 +|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 501 +|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 488 488 |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)((( 489 489 * =0, Disable 490 490 * =1, Enable ... ... @@ -591,6 +591,9 @@ 591 591 * =0: Server connection exception 592 592 * =1: Server connection is OK 593 593 ))) 608 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)((( 609 +Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890) 610 +))) 594 594 |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1 595 595 |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2 596 596 |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -618,10 +618,180 @@ 618 618 * =1: Server connection is OK 619 619 ))) 620 620 |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger 638 +|=(% style="width: 160px;" %)((( 639 +HSW1762 640 +)))|(% colspan="1" rowspan="13" style="width:282px" %)((( 641 +Note: Valid when Ethernet2 of HMI is plugged into the network cable. 642 +①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 643 +②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 644 +③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 645 +④.IP related registers can be read and written (only static IP mode can be written). 646 +)))|(% style="width:452px" %)((( 647 +Ethernet2 Local IP address high byte 1 648 +))) 649 +|=(% style="width: 160px;" %)((( 650 +HSW1763 651 +)))|(% style="width:452px" %)((( 652 +Ethernet2 Local IP address high byte 2 653 +))) 654 +|=(% style="width: 160px;" %)((( 655 +HSW1764 656 +)))|(% style="width:452px" %)((( 657 +Ethernet2 Local IP address high byte 3 658 +))) 659 +|=(% style="width: 160px;" %)((( 660 +HSW1765 661 +)))|(% style="width:452px" %)((( 662 +Ethernet2 Local IP address high byte 4 663 +))) 664 +|=(% style="width: 160px;" %)((( 665 +HSW1766 666 +)))|(% style="width:452px" %)((( 667 +Ethernet2 Local mask IP address high byte 1 668 +))) 669 +|=(% style="width: 160px;" %)((( 670 +HSW1767 671 +)))|(% style="width:452px" %)((( 672 +Ethernet2 Local mask IP address high byte 2 673 +))) 674 +|=(% style="width: 160px;" %)((( 675 +HSW1768 676 +)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3 677 +|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4 678 +|=(% style="width: 160px;" %)((( 679 +HSW1770 680 +)))|(% style="width:452px" %)((( 681 +Ethernet2 Local gateway IP address high byte 1 682 +))) 683 +|=(% style="width: 160px;" %)((( 684 +HSW1771 685 +)))|(% style="width:452px" %)((( 686 +Ethernet2 Local gateway IP address high byte 2 687 +))) 688 +|=(% style="width: 160px;" %)((( 689 +HSW1772 690 +)))|(% style="width:452px" %)((( 691 +Ethernet2 Local gateway IP address high byte 3 692 +))) 693 +|=(% style="width: 160px;" %)((( 694 +HSW1773 695 +)))|(% style="width:452px" %)((( 696 +Ethernet2 Local gateway IP address high byte 4 697 +))) 698 +|=(% style="width: 160px;" %)((( 699 +HSW1774 700 +)))|(% style="width:452px" %)((( 701 +Ethernet2 Local Port Address 702 +))) 703 +|=(% style="width: 160px;" %)((( 704 +HSW1775 705 +)))|(% colspan="1" rowspan="6" style="width:282px" %)((( 706 +①Display the MAC code of Ethernet2 NIC 707 + 708 +(hexadecimal display) 709 + 710 +②Read-only mode, not modifiable 711 +)))|(% style="width:452px" %)((( 712 +Ethernet2 Local MAC code high byte 1 713 +))) 714 +|=(% style="width: 160px;" %)((( 715 +HSW1776 716 +)))|(% style="width:452px" %)((( 717 +Ethernet2 Local MAC code high byte 2 718 +))) 719 +|=(% style="width: 160px;" %)((( 720 +HSW1777 721 +)))|(% style="width:452px" %)((( 722 +Ethernet2 Local MAC code high byte 3 723 +))) 724 +|=(% style="width: 160px;" %)((( 725 +HSW1778 726 +)))|(% style="width:452px" %)((( 727 +Ethernet2 Local MAC code high byte 4 728 +))) 729 +|=(% style="width: 160px;" %)((( 730 +HSW1779 731 +)))|(% style="width:452px" %)((( 732 +Ethernet2 Local MAC code high byte 5 733 +))) 734 +|=(% style="width: 160px;" %)((( 735 +HSW1780 736 +)))|(% style="width:452px" %)((( 737 +Ethernet2 Local MAC code high byte 6 738 +))) 739 +|=(% style="width: 160px;" %)((( 740 +HSW1781 741 +)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 742 +①Display and modify DNS1 and DNS2 of Ethernet2 743 + 744 +②Related registers can be read and written mode (only static IP mode can be written) 745 +)))|(% style="width:452px" %)((( 746 +Ethernet2 Local DNS1 address high byte 1 747 +))) 748 +|=(% style="width: 160px;" %)((( 749 +HSW1782 750 +)))|(% style="width:452px" %)((( 751 +Ethernet2 Local DNS1 address high byte 2 752 +))) 753 +|=(% style="width: 160px;" %)((( 754 +HSW1783 755 +)))|(% style="width:452px" %)((( 756 +Ethernet2 Local DNS1 address high byte 3 757 +))) 758 +|=(% style="width: 160px;" %)((( 759 +HSW1784 760 +)))|(% style="width:452px" %)((( 761 +Ethernet2 Local DNS1 address high byte 4 762 +))) 763 +|=(% style="width: 160px;" %)((( 764 +HSW1785 765 +)))|(% style="width:452px" %)((( 766 +Ethernet2 Local DNS2 address high byte 1 767 +))) 768 +|=(% style="width: 160px;" %)((( 769 +HSW1786 770 +)))|(% style="width:452px" %)((( 771 +Ethernet2 Local DNS2 address high byte 2 772 +))) 773 +|=(% style="width: 160px;" %)((( 774 +HSW1787 775 +)))|(% style="width:452px" %)((( 776 +Ethernet2 Local DNS2 address high byte 3 777 +))) 778 +|=(% style="width: 160px;" %)((( 779 +HSW1788 780 +)))|(% style="width:452px" %)((( 781 +Ethernet2 Local DNS2 address high byte 4 782 +))) 783 +|=(% style="width: 160px;" %)((( 784 +HSW1789 785 +)))|(% colspan="1" style="width:282px" %)((( 786 +Display or set the dynamic or static IP mode of Ethernet2 787 +)))|(% style="width:452px" %)((( 788 +HSX1789.0 = 0, Static IP mode 789 + 790 +HSX1789.0 = 1, dynamic IP mode 791 +))) 792 +|=(% style="width: 160px;" %)((( 793 +HSW1790 794 +)))|(% colspan="1" style="width:282px" %)((( 795 +Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings 796 +)))|(% style="width:452px" %)((( 797 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 798 +))) 799 +|=(% style="width: 160px;" %)((( 800 +HSW1791 801 +)))|(% colspan="1" style="width:282px" %)((( 802 +Network status of the Ethernet2 connection server 803 +)))|(% style="width:452px" %)((( 804 +~= 0, connection to the server is abnormal = 1, connection to the server is normal 805 +))) 621 621 |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms. 622 622 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 623 623 * =0: db database 624 624 * =1: CSV 810 + 811 +(Only valid for script function DbToCsvFile) 625 625 ))) 626 626 |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)((( 627 627 * =0: use the old high-low word conversion (default) ... ... @@ -644,11 +644,11 @@ 644 644 * =2: enter the background 645 645 ))) 646 646 |=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)((( 647 -* =0: priority 834 +* =0: priority Ethernet 648 648 * =1: priority WLAN 649 649 * =2: priority 4G 650 650 ))) 651 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the L Ua extension module file|(% style="width:452px" %)(((838 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)((( 652 652 * =0: delete; 653 653 * = Others: do not delete 654 654 ))) ... ... @@ -664,14 +664,75 @@ 664 664 * = 0: yes (default); 665 665 * = 1: no 666 666 ))) 854 +|=(% style="width: 160px;" %)((( 855 +HSW1869 856 +)))|(% style="width:282px" %)((( 857 +Dynamic screensaver countdown 858 +)))|(% style="width:452px" %)((( 859 +Countdown to enter dynamic screensaver effect, unit (S) 860 +))) 861 +|=(% style="width: 160px;" %)((( 862 +HSW1870 863 +)))|(% style="width:282px" %)((( 864 +Display or set the dynamic or static IP mode of Ethernet1 865 +)))|(% style="width:452px" %)((( 866 +HSX1870.0 = 0, Static IP mode 867 + 868 +HSX1870.0 = 1, dynamic IP mode 869 +))) 870 +|=(% style="width: 160px;" %)((( 871 +HSW1871 872 +)))|(% style="width:282px" %)((( 873 +Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1 874 +)))|(% style="width:452px" %)((( 875 +~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 876 +))) 877 +|=(% style="width: 160px;" %)((( 878 +HSW1872 879 +)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 880 +①Display and modify DNS1 and DNS2 of Ethernet1 881 + 882 +②Related registers can be read and written mode (only static IP mode can be written) 883 +)))|(% style="width:452px" %)((( 884 +Ethernet1 Local DNS1 address high byte 1 885 +))) 886 +|=(% style="width: 160px;" %)((( 887 +HSW1873 888 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2 889 +|=(% style="width: 160px;" %)((( 890 +HSW1874 891 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3 892 +|=(% style="width: 160px;" %)((( 893 +HSW1875 894 +)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4 895 +|=(% style="width: 160px;" %)((( 896 +HSW1876 897 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1 898 +|=(% style="width: 160px;" %)((( 899 +HSW1877 900 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2 901 +|=(% style="width: 160px;" %)((( 902 +HSW1878 903 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3 904 +|=(% style="width: 160px;" %)((( 905 +HSW1879 906 +)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 907 +|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)((( 908 +* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval) 909 +* =Others: not refresh 910 +))) 911 +|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data |(% style="width:452px" %)((( 912 +* =1, not clear screen cache when switch language 913 +* =2, trigger clear cache of all screens for once time 914 +* =3, always clear cache of all screen data 915 +))) 667 667 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 668 668 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 669 -**✎Note: **Only valid when the HMI is plugged into the Ethernet cable. 670 - 671 -1. If Ethernet settings is enabled in project parameters, this register displays the set value. 672 -1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP. 673 -1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set. 674 -1. 4. All IP registers of HMI are read-only. 918 +Note: Valid when Ethernet1 of HMI is plugged into the network cable. 919 +① When the Ethernet setting is enabled in the project parameters, this register displays the set value. 920 +② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 921 +③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 922 +④ IP related registers can be read and written (only static IP mode can be written). 675 675 )))|(% style="width:452px" %)Local IP address high byte 1 676 676 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 677 677 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -686,9 +686,11 @@ 686 686 |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4 687 687 |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address 688 688 |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)((( 689 -Display sthe MAC code of thecurrent networkcard937 +①Display the MAC code of Ethernet1 NIC 690 690 691 -(Hexadecimal display) 939 +(hexadecimal display) 940 + 941 +②Read-only mode, not modifiable 692 692 )))|(% style="width:452px" %)Local MAC code high word 1 693 693 |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2 694 694 |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3 ... ... @@ -695,7 +695,7 @@ 695 695 |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4 696 696 |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5 697 697 |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6 698 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC948 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 699 699 |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 700 700 |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password 701 701 |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit) ... ... @@ -763,6 +763,7 @@ 763 763 * =0: LAN or the external network both OK 764 764 * =1: Only LAN access 765 765 * =2: Only external network can access 1016 +* =3: Close the functions 766 766 ))) 767 767 |=(% style="width: 160px;" %)HSW11757|(% style="width:282px" %)Enable the valid date of the dynamic installment password|(% style="width:452px" %)((( 768 768 * =0: Disabled ... ... @@ -777,7 +777,34 @@ 777 777 ))) 778 778 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 779 779 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 1031 +|=(% style="width: 160px;" %)((( 1032 +HSW11762 1033 +)))|(% style="width:282px" %)((( 1034 +Dynamic screensaver control address 1035 +)))|(% style="width:452px" %)((( 1036 +HSX11762.0=0, initialize with project configuration; 780 780 1038 +HSX11762.0=1, initialize with special register configuration; 1039 + 1040 +HSX11762.1=0, disable dynamic screensaver; 1041 + 1042 +HSX11762.1=1, enable dynamic screensaver 1043 +))) 1044 +|=(% style="width: 160px;" %)((( 1045 +HSW11763 1046 +)))|(% style="width:282px" %)((( 1047 +Waiting time to enter the dynamic screensaver 1048 +)))|(% style="width:452px" %)((( 1049 +Waiting time when the screen is not operated, range 1~~720 minutes 1050 +))) 1051 +|=(% style="width: 160px;" %)((( 1052 +HSW11764 1053 +)))|(% style="width:282px" %)((( 1054 +Animated screensaver animation type 1055 +)))|(% style="width:452px" %)((( 1056 +~=0: Raster,=1: Blinds,=2: Bubble 1057 +))) 1058 + 781 781 == Serial port communication configuration == 782 782 783 783 (% class="table-bordered" %)
- 6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Mora - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.1 KB - Content