Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
From version 10.1
edited by Theodore Xu
on 2022/12/16 10:09
on 2022/12/16 10:09
Change comment:
There is no comment for this version
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.Stone - Content
-
... ... @@ -4,11 +4,11 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - ***System data area (HSW): **A special register defined by the system.8 - ***Data storage area (HDW/HDX): **Users store user data.9 - ***System data area (HUW): **A special register defined by the system.10 - ***System Data (HAW)**: System register used for power-off save.11 - ***Recipe index area (RPW): **System register used for recipe index.7 +1. **System data area (HSW): **A special register defined by the system. 8 +1. **Data storage area (HDW/HDX): **Users store user data. 9 +1. **System data area (HUW): **A special register defined by the system. 10 +1. **System Data (HAW)**: System register used for power-off save. 11 +1. **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 ... ... @@ -643,26 +643,21 @@ 643 643 * =1: download firmware 644 644 * =2: enter the background 645 645 ))) 646 -|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)((( 647 -* =0: priority Ethernet 648 -* =1: priority WLAN 649 -* =2: priority 4G 650 -))) 651 651 |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 652 -* = 0:delete;653 -* = Others :do not delete647 +* =1, delete; 648 +* = Others, do not delete 654 654 ))) 655 655 |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 656 656 Monitor address is set during reset of reset switch, whether to cancel reset, 657 657 658 -* = 0 :yes (default);659 -* = 1 :no653 +* = 0, yes (default); 654 +* = 1, no 660 660 ))) 661 661 |=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 662 662 Controls whether the button pops up when double-clicking or long pressing on record type table object 663 663 664 -* = 0 :yes (default);665 -* = 1 :no659 +* = 0, yes (default); 660 +* = 1, no 666 666 ))) 667 667 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 668 668 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( ... ... @@ -778,7 +778,7 @@ 778 778 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 779 779 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 780 780 781 -== Serial port communication configuration == 776 +== **Serial port communication configuration** == 782 782 783 783 (% class="table-bordered" %) 784 784 |=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** ... ... @@ -1073,19 +1073,18 @@ 1073 1073 For example, when the baud rate required is 250000, just enter 250. 1074 1074 ))) 1075 1075 1076 -== Ethernet communication configuration == 1071 +== **Ethernet communication configuration** == 1077 1077 1078 1078 (% class="table-bordered" %) 1079 -|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description** 1074 +|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description** 1080 1080 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 1081 1081 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2 1082 1082 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3 1083 1083 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4 1084 1084 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number 1085 -|(% style="width:220px" %)HSW11009|(% style="width:336px" %)((( 1086 -~=2 TCP 1087 - 1088 -~=3 UDP 1080 +|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)((( 1081 +* =2 TCP 1082 +* =3 UDP 1089 1089 ))) 1090 1090 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved 1091 1091 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -1093,10 +1093,9 @@ 1093 1093 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3 1094 1094 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4 1095 1095 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number 1096 -|(% style="width:220px" %)HSW11016|(% style="width:336px" %)((( 1097 -~=2 TCP 1098 - 1099 -~=3 UDP 1090 +|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)((( 1091 +* =2 TCP 1092 +* =3 UDP 1100 1100 ))) 1101 1101 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved 1102 1102 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)… ... ... @@ -1105,11 +1105,7 @@ 1105 1105 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3 1106 1106 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4 1107 1107 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number 1108 -|(% style="width:220px" %)HSW11226|(% style="width:336px" %)((( 1109 -~=2 TCP; 1110 - 1111 -~=3 UDP 1112 -))) 1101 +|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 1113 1113 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 1114 1114 1115 1115 (% class="box infomessage" %) ... ... @@ -1117,7 +1117,7 @@ 1117 1117 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1118 1118 ))) 1119 1119 1120 -== Communication control == 1109 +== **Communication control** == 1121 1121 1122 1122 (% class="table-bordered" %) 1123 1123 |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**