Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 10.1
edited by Theodore Xu
on 2022/12/16 10:09
Change comment: There is no comment for this version
To version 8.1
edited by Stone Wu
on 2022/08/25 17:27
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.AiXia
1 +XWiki.Stone
Content
... ... @@ -643,26 +643,21 @@
643 643  * =1: download firmware
644 644  * =2: enter the background
645 645  )))
646 -|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
647 -* =0: priority  Ethernet
648 -* =1: priority WLAN
649 -* =2: priority 4G
650 -)))
651 651  |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
652 -* =0: delete;
653 -* = Others: do not delete
647 +* =1, delete;
648 +* = Others, do not delete
654 654  )))
655 655  |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
656 656  Monitor address is set during reset of reset switch, whether to cancel reset,
657 657  
658 -* = 0: yes (default);
659 -* = 1: no
653 +* = 0, yes (default);
654 +* = 1, no
660 660  )))
661 661  |=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
662 662  Controls whether the button pops up when double-clicking or long pressing on record type table object
663 663  
664 -* = 0: yes (default);
665 -* = 1: no
659 +* = 0, yes (default);
660 +* = 1, no
666 666  )))
667 667  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
668 668  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((