Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
From version 11.1
edited by Theodore Xu
on 2022/12/16 10:14
on 2022/12/16 10:14
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 -PIStudio.WebHome 1 +PIStudio.1 User Manual.WebHome - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.Hunter - Content
-
... ... @@ -4,26 +4,27 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - ***System data area (HSW): **A special register defined by the system.8 - ***Data storage area (HDW/HDX): **Users store user data.9 - ***System data area (HUW): **A special register defined by the system.10 - ***System Data (HAW)**: System register used for power-off save.11 - ***Recipe index area (RPW): **System register used for recipe index.7 +1. **System data area (HSW): **A special register defined by the system. 8 +1. **Data storage area (HDW/HDX): **Users store user data. 9 +1. **System data area (HUW): **A special register defined by the system. 10 +1. **System Data (HAW)**: System register used for power-off save. 11 +1. **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 15 -* Access as word with the prefix "HDW". 16 -** HDW0 means the 1st word of system data area. HDW1 means the 2nd word of system data area. 17 -* Access as bit with the prefix "HDX". The number before "." i". The number before Access in bit with the prefix "HD". The number before Access in bit with the prefix "HDX". The number before "." indicates the number of the word. The number after "." indicates the bit number of the word. 18 -** HDX1020.12 means to access the system data area in bit mode, the specific location is the 13th bit of the 1020 word. 15 +1. Access as word with the prefix "HDW". 19 19 20 -(% class="box infomessage" %) 21 -((( 17 +* HDW0 means the 1st word of system data area. HDW1 means the 2nd word of system data area. 18 + 19 +(% start="2" %) 20 +1. Access as bit with the prefix "HDX". The number before "." i". The number before Access in bit with the prefix "HD". The number before Access in bit with the prefix "HDX". The number before "." indicates the number of the word. The number after "." indicates the bit number of the word. 21 + 22 +* HDX1020.12 means to access the system data area in bit mode, the specific location is the 13th bit of the 1020 word. 23 + 22 22 **✎Note:** 23 23 24 24 * Addresses in HDX are the bits from words in HDW, so be careful when using addresses. For example, HDX1020.12 is the 13th bit to access the 1020 word. The value of this bit is the same as that of the word accessed through HDW001020. The 13th bit of this word is actually the same bit as HDX1020.12. 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 -))) 27 27 28 28 = **Data storage area (HDW/HDX)** = 29 29 ... ... @@ -39,13 +39,10 @@ 39 39 1. Access as word, and serial number range is from HAW0 to HAW199999. 40 40 1. Access as bit, and serial number range is from HAX0.0 to HAX199999.15. 41 41 42 -(% class="box infomessage" %) 43 -((( 44 44 **✎Note:** 45 45 46 46 * HAW/HAX is power-down retention. The register of this type is able to save the data before the power-down. 47 47 * To avoid possible device failure, do not immediately power off and reboot when configuring the power-down save addre 48 -))) 49 49 50 50 = **Recipe index area (RPW)** = 51 51 ... ... @@ -339,11 +339,9 @@ 339 339 * HDX882.1=0 SD card doesn't execute storage or storage finished. 340 340 * HDX882.1=1 SD card is reading data, don't remove SD card. 341 341 ))) 342 -|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter the system network configuration interface|(% style="width:452px" %)((( 343 -* =0: Do not enter the network configuration interface 344 -* =1: Enter the system network configuration interface. 345 -** ig series HMI only supports to enter the system interface 346 - 340 +|=(% style="width: 160px;" %)HSW884|(% style="width:282px" %)Enter setup screen|(% style="width:452px" %)((( 341 +* = 0: Do not into setup screen 342 +* = 1: Enter setup screen 347 347 ))) 348 348 |=(% style="width: 160px;" %)HSW885|(% style="width:282px" %)When the control object hides the address is read failed (communication failure), set the display mode of the object|(% style="width:452px" %)((( 349 349 * = 0: displayed by object setting. ... ... @@ -512,10 +512,6 @@ 512 512 * HSX1502.0=1: Modification comfirmed. Save the data of HSW1450~~HSW1501 to a file for immediate effect. 513 513 * HSX1502.1=1:Modification cancelled. Restore the current data of hSW1450-HSW1501 to the data saved in the file last time. 514 514 ))) 515 -|=(% style="width: 160px;" %)HSW1509|(% style="width:282px" %)Curve width|(% style="width:452px" %)((( 516 -* =0: Use the curve width set by project default. 517 -* =1 to 10: use special register to set curve width. 518 -))) 519 519 |=(% style="width: 160px;" %)HSW1603|(% style="width:282px" %)Number of current unreleased alarms|(% style="width:452px" %)The number of current unreleased alarms in alarm record file. 520 520 |=(% style="width: 160px;" %)HSW1604|(% style="width:282px" %)The auxiliary judgment address when the control bit in the Object Lock fails to be read|(% style="width:452px" %)((( 521 521 * =0: The auxiliary address is invalid. ... ... @@ -643,27 +643,6 @@ 643 643 * =1: download firmware 644 644 * =2: enter the background 645 645 ))) 646 -|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)((( 647 -* =0: priority Ethernet 648 -* =1: priority WLAN 649 -* =2: priority 4G 650 -))) 651 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 652 -* =0: delete; 653 -* = Others: do not delete 654 -))) 655 -|=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 656 -Monitor address is set during reset of reset switch, whether to cancel reset, 657 - 658 -* = 0: yes (default); 659 -* = 1: no 660 -))) 661 -|=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 662 -Controls whether the button pops up when double-clicking or long pressing on record type table object 663 - 664 -* = 0: yes (default); 665 -* = 1: no 666 -))) 667 667 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 668 668 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 669 669 **✎Note: **Only valid when the HMI is plugged into the Ethernet cable. ... ... @@ -778,10 +778,10 @@ 778 778 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 779 779 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 780 780 781 -== Serial port communication configuration == 752 +== **Serial port communication configuration** == 782 782 783 783 (% class="table-bordered" %) 784 -|=(% s cope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**755 +|=(% style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 785 785 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( 786 786 * =0: RS232 787 787 * =1: RS485 ... ... @@ -811,22 +811,10 @@ 811 811 * =1: ODD 812 812 * =2: EVEN 813 813 ))) 814 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 815 -* Unit: ms. 816 -* Range: 0 to 30000 817 -))) 818 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 819 -* Unit: ms. 820 -* Range: 0 to 30000 821 -))) 822 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 823 -* Unit: times. 824 -* Range: 0 to 100 825 -))) 826 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 827 -* Unit: s. 828 -* Range: 0 to 300 829 -))) 785 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 786 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 787 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 788 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 830 830 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 831 831 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 832 832 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -859,22 +859,10 @@ 859 859 * =1: ODD 860 860 * =2: EVEN 861 861 ))) 862 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 863 -* Unit: ms. 864 -* Range: 0 to 30000 865 -))) 866 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 867 -* Unit: ms. 868 -* Range: 0 to 30000 869 -))) 870 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 871 -* Unit: times. 872 -* Range: 0 to 100 873 -))) 874 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 875 -* Unit: s. 876 -* Range: 0 to 30 877 -))) 821 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 822 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 823 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 824 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 878 878 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 879 879 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 880 880 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -907,22 +907,10 @@ 907 907 * =1: ODD 908 908 * =2: EVEN 909 909 ))) 910 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 911 -* Unit: ms. 912 -* Range: 0 to 30000 913 -))) 914 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 915 -* Unit: ms. 916 -* Range: 0 to 30000 917 -))) 918 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 919 -* Unit: times. 920 -* Range: 0 to 100 921 -))) 922 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 923 -* Unit: s. 924 -* Range: 0 to 30 925 -))) 857 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 858 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 859 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 860 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 926 926 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 927 927 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 928 928 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -953,22 +953,10 @@ 953 953 * =1: ODD 954 954 * =2: EVEN 955 955 ))) 956 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 957 -* Unit: ms. 958 -* Range: 0 to 30000 959 -))) 960 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 961 -* Unit: ms. 962 -* Range: 0 to 30000 963 -))) 964 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 965 -* Unit: times. 966 -* Range: 0 to 100 967 -))) 968 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 969 -* Unit: s. 970 -* Range: 0 to 30 971 -))) 891 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 892 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 893 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 894 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 972 972 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 973 973 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 974 974 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -999,22 +999,10 @@ 999 999 * =1: ODD 1000 1000 * =2: EVEN 1001 1001 ))) 1002 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 1003 -* Unit: ms. 1004 -* Range: 0 to 30000 1005 -))) 1006 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1007 -* Unit: ms. 1008 -* Range: 0 to 30000 1009 -))) 1010 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1011 -* Unit: times. 1012 -* Range: 0 to 100 1013 -))) 1014 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1015 -* Unit: s. 1016 -* Range: 0 to 30 1017 -))) 925 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 926 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 927 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 928 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1018 1018 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 1019 1019 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 1020 1020 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -1044,48 +1044,29 @@ 1044 1044 * =1: ODD 1045 1045 * =2: EVEN 1046 1046 ))) 1047 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1048 -* Unit: ms. 1049 -* Range: 0 to 30000 1050 -))) 1051 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1052 -* Unit: ms. 1053 -* Range: 0 to 30000 1054 -))) 1055 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1056 -* Unit: times. 1057 -* Range: 0 to 100 1058 -))) 1059 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1060 -* Unit: s. 1061 -* Range: 0 to 30 1062 -))) 958 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 959 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 960 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 961 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1063 1063 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 1064 1064 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 1065 1065 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 1066 -Unit: K, the baud rate must be an integer. 1067 - 1068 -For example, when the baud rate required is 250000, just enter 250. 965 +Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1069 1069 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 1070 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1071 -Unit: K, the baud rate must be an integer. 967 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1072 1072 1073 -For example, when the baud rate required is 250000, just enter 250. 1074 -))) 969 +== **Ethernet communication configuration** == 1075 1075 1076 -== Ethernet communication configuration == 1077 - 1078 1078 (% class="table-bordered" %) 1079 -|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description** 972 +|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description** 1080 1080 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 1081 1081 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2 1082 1082 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3 1083 1083 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4 1084 1084 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number 1085 -|(% style="width:220px" %)HSW11009|(% style="width:336px" %)((( 1086 -~=2 TCP 1087 - 1088 -~=3 UDP 978 +|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)((( 979 +* =2 TCP 980 +* =3 UDP 1089 1089 ))) 1090 1090 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved 1091 1091 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -1093,10 +1093,9 @@ 1093 1093 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3 1094 1094 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4 1095 1095 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number 1096 -|(% style="width:220px" %)HSW11016|(% style="width:336px" %)((( 1097 -~=2 TCP 1098 - 1099 -~=3 UDP 988 +|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)((( 989 +* =2 TCP 990 +* =3 UDP 1100 1100 ))) 1101 1101 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved 1102 1102 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)… ... ... @@ -1105,22 +1105,16 @@ 1105 1105 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3 1106 1106 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4 1107 1107 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number 1108 -|(% style="width:220px" %)HSW11226|(% style="width:336px" %)((( 1109 -~=2 TCP; 1110 - 1111 -~=3 UDP 1112 -))) 999 +|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 1113 1113 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 1114 1114 1115 -(% class="box infomessage" %) 1116 -((( 1002 +(% class="wikigeneratedid" %) 1117 1117 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1118 -))) 1119 1119 1120 -== Communication control == 1005 +== **Communication control** == 1121 1121 1122 1122 (% class="table-bordered" %) 1123 -| =(% style="width:;" %)**Communication No.**|=(% style="width:;" %)**Station No.**|=(% style="width:;" %)**Control bit**|=(% style="width:;" %)**Communication lamp**|=(% style="width:;" %)**Description**1008 +|(% style="width:135px" %)**Communication No.**|(% style="width:102px" %)**Station No.**|(% style="width:185px" %)**Control bit**|(% style="width:191px" %)**Communication lamp**|(% style="width:271px" %)**Description** 1124 1124 |(% colspan="1" rowspan="16" style="width:135px" %)1|(% style="width:102px" %)0~~15|(% style="width:185px" %)HSX550.0~HSX550.15|(% style="width:191px" %)HSX558.0~HSX558.15|(% rowspan="160" style="width:271px" %)Communication number refers to the number in "Communication Port Configuration". A number provides 256 device station numbers. Each station number corresponds to a communication control bit and a communication indicator bit. Registers HSX550.0 to HSX805.15 are used to control the station numbers from 0 to 127, and registers HSX1150.0 to HSX1405.15 are used to control station numbers 128 to 255. 1125 1125 |(% style="width:102px" %)16~~31|(% style="width:185px" %)HSX551.0~HSX551.15|(% style="width:191px" %)HSX559.0~HSX559.15 1126 1126 |(% style="width:102px" %)32~~47|(% style="width:185px" %)HSX552.0~HSX552.15|(% style="width:191px" %)HSX560.0~HSX560.15