Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 12.1
edited by Bob
on 2023/01/07 14:26
Change comment: There is no comment for this version
To version 16.3
edited by Hunter
on 2023/02/18 11:32
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bob
1 +XWiki.Hunter
Content
... ... @@ -241,8 +241,8 @@
241 241  * =2: HSX521.1=1, delete all trend graph.
242 242  * =4: HSX521.2=1, delete all alarms.
243 243  * =16: HSX521.4=1, delete history XY plot.
244 -* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting).
245 -* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting).
244 +* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting).
245 +* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting).
246 246  )))
247 247  |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)(((
248 248  * =0: No operation
... ... @@ -485,6 +485,8 @@
485 485  * =0, Default value
486 486  * =1, Release the alarm generated before the last power-down when starting up
487 487  )))
488 +|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
489 +|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
488 488  |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
489 489  * =0, Disable
490 490  * =1, Enable
... ... @@ -591,6 +591,9 @@
591 591  * =0: Server connection exception
592 592  * =1: Server connection is OK
593 593  )))
596 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal signal strength|(% style="width:452px" %)(((
597 +Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
598 +)))
594 594  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
595 595  |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2
596 596  |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -790,6 +790,8 @@
790 790  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
791 791  * =0: db database
792 792  * =1: CSV
798 +
799 +(Only valid for script function DbToCsvFile)
793 793  )))
794 794  |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
795 795  * =0: use the old high-low word conversion (default)
... ... @@ -816,9 +816,9 @@
816 816  * =1: priority WLAN
817 817  * =2: priority 4G
818 818  )))
819 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
826 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
820 820  * =0: delete;
821 -* = Others: do not delete
828 +* = Others value: do not delete
822 822  )))
823 823  |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
824 824  Monitor address is set during reset of reset switch, whether to cancel reset,
... ... @@ -833,6 +833,13 @@
833 833  * = 1: no
834 834  )))
835 835  |=(% style="width: 160px;" %)(((
843 +HSW1869
844 +)))|(% style="width:282px" %)(((
845 +Dynamic screensaver countdown
846 +)))|(% style="width:452px" %)(((
847 +Countdown to enter dynamic screensaver effect, unit (S)
848 +)))
849 +|=(% style="width: 160px;" %)(((
836 836  HSW1870
837 837  )))|(% style="width:282px" %)(((
838 838  Display or set the dynamic or static IP mode of Ethernet1
... ... @@ -910,7 +910,7 @@
910 910  |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
911 911  |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
912 912  |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
913 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
927 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
914 914  |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
915 915  |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
916 916  |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
... ... @@ -992,7 +992,34 @@
992 992  )))
993 993  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
994 994  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1009 +|=(% style="width: 160px;" %)(((
1010 +HSW11762
1011 +)))|(% style="width:282px" %)(((
1012 +Dynamic screensaver control address
1013 +)))|(% style="width:452px" %)(((
1014 +HSX11762.0=0, initialize with project configuration;
995 995  
1016 +HSX11762.0=1, initialize with special register configuration;
1017 +
1018 +HSX11762.1=0, disable dynamic screensaver;
1019 +
1020 +HSX11762.1=1, enable dynamic screensaver
1021 +)))
1022 +|=(% style="width: 160px;" %)(((
1023 +HSW11763
1024 +)))|(% style="width:282px" %)(((
1025 +Waiting time to enter the dynamic screensaver
1026 +)))|(% style="width:452px" %)(((
1027 +Waiting time when the screen is not operated, range 1~~720 minutes
1028 +)))
1029 +|=(% style="width: 160px;" %)(((
1030 +HSW11764
1031 +)))|(% style="width:282px" %)(((
1032 +Animated screensaver animation type
1033 +)))|(% style="width:452px" %)(((
1034 +~=0: Raster,=1: Blinds,=2: Bubble
1035 +)))
1036 +
996 996  == Serial port communication configuration ==