Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 12.1
edited by Bob
on 2023/01/07 14:26
Change comment: There is no comment for this version
To version 17.1
edited by Hunter
on 2023/02/18 13:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Bob
1 +XWiki.Hunter
Content
... ... @@ -241,8 +241,8 @@
241 241  * =2: HSX521.1=1, delete all trend graph.
242 242  * =4: HSX521.2=1, delete all alarms.
243 243  * =16: HSX521.4=1, delete history XY plot.
244 -* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting).
245 -* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting).
244 +* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting).
245 +* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting).
246 246  )))
247 247  |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)(((
248 248  * =0: No operation
... ... @@ -485,6 +485,8 @@
485 485  * =0, Default value
486 486  * =1, Release the alarm generated before the last power-down when starting up
487 487  )))
488 +|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
489 +|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
488 488  |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
489 489  * =0, Disable
490 490  * =1, Enable
... ... @@ -591,6 +591,9 @@
591 591  * =0: Server connection exception
592 592  * =1: Server connection is OK
593 593  )))
596 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)(((
597 +Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
598 +)))
594 594  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
595 595  |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2
596 596  |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -790,6 +790,8 @@
790 790  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
791 791  * =0: db database
792 792  * =1: CSV
798 +
799 +(Only valid for script function DbToCsvFile)
793 793  )))
794 794  |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
795 795  * =0: use the old high-low word conversion (default)
... ... @@ -816,7 +816,7 @@
816 816  * =1: priority WLAN
817 817  * =2: priority 4G
818 818  )))
819 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
826 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
820 820  * =0: delete;
821 821  * = Others: do not delete
822 822  )))
... ... @@ -833,6 +833,13 @@
833 833  * = 1: no
834 834  )))
835 835  |=(% style="width: 160px;" %)(((
843 +HSW1869
844 +)))|(% style="width:282px" %)(((
845 +Dynamic screensaver countdown
846 +)))|(% style="width:452px" %)(((
847 +Countdown to enter dynamic screensaver effect, unit (S)
848 +)))
849 +|=(% style="width: 160px;" %)(((
836 836  HSW1870
837 837  )))|(% style="width:282px" %)(((
838 838  Display or set the dynamic or static IP mode of Ethernet1
... ... @@ -878,6 +878,15 @@
878 878  |=(% style="width: 160px;" %)(((
879 879  HSW1879
880 880  )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
895 +|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)(((
896 +* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval)
897 +* =Others: not refresh
898 +)))
899 +|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data  |(% style="width:452px" %)(((
900 +* =1, not clear screen cache when switch language
901 +* =2, trigger clear cache of all screens for once time
902 +* =3, always clear cache of all screen data
903 +)))
881 881  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
882 882  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
883 883  Note: Valid when Ethernet1 of HMI is plugged into the network cable.
... ... @@ -910,7 +910,7 @@
910 910  |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
911 911  |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
912 912  |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
913 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
936 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
914 914  |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
915 915  |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
916 916  |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
... ... @@ -992,7 +992,34 @@
992 992  )))
993 993  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
994 994  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1018 +|=(% style="width: 160px;" %)(((
1019 +HSW11762
1020 +)))|(% style="width:282px" %)(((
1021 +Dynamic screensaver control address
1022 +)))|(% style="width:452px" %)(((
1023 +HSX11762.0=0, initialize with project configuration;
995 995  
1025 +HSX11762.0=1, initialize with special register configuration;
1026 +
1027 +HSX11762.1=0, disable dynamic screensaver;
1028 +
1029 +HSX11762.1=1, enable dynamic screensaver
1030 +)))
1031 +|=(% style="width: 160px;" %)(((
1032 +HSW11763
1033 +)))|(% style="width:282px" %)(((
1034 +Waiting time to enter the dynamic screensaver
1035 +)))|(% style="width:452px" %)(((
1036 +Waiting time when the screen is not operated, range 1~~720 minutes
1037 +)))
1038 +|=(% style="width: 160px;" %)(((
1039 +HSW11764
1040 +)))|(% style="width:282px" %)(((
1041 +Animated screensaver animation type
1042 +)))|(% style="width:452px" %)(((
1043 +~=0: Raster,=1: Blinds,=2: Bubble
1044 +)))
1045 +
996 996  == Serial port communication configuration ==
997 997  
998 998  (% class="table-bordered" %)