Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
From version 15.1
edited by Theodore Xu
on 2023/01/09 15:29
on 2023/01/09 15:29
Change comment:
There is no comment for this version
Summary
-
Page properties (3 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Title
-
... ... @@ -1,1 +1,1 @@ 1 -1 2HMIinternalregisters1 +13.HMI Internal Registers - Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. AiXia1 +XWiki.Mora - Content
-
... ... @@ -25,6 +25,11 @@ 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 26 ))) 27 27 28 += Address ranges table = 29 + 30 +(% style="text-align:center" %) 31 +[[image:6.png]] 32 + 28 28 = **Data storage area (HDW/HDX)** = 29 29 30 30 It is used to save the temporary data of project. ... ... @@ -60,8 +60,8 @@ 60 60 61 61 It is used for system special registers (reserved by system). 62 62 63 -1. Access as word, and serial number range is from HUW0 to HUW199 999.64 -1. Access as bit, and serial number range is from HUX0.0 to HUX199 999.15.68 +1. Access as word, and serial number range is from HUW0 to HUW1599. 69 +1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15. 65 65 66 66 **✎Note:** 67 67 ... ... @@ -135,8 +135,8 @@ 135 135 (% class="table-bordered" style="width:1024px" %) 136 136 |=(% scope="row" style="width: 160px;" %)**Address**|=(% style="width: 282px;" %)**Function**|=(% style="width: 452px;" %)**Description** 137 137 |=(% style="width: 160px;" %)HSW0|(% style="width:282px" %)Language switch|(% style="width:452px" %)Multiple language could be set in the project, HMI support maximum 8 languages. (Power-down save supported) 138 -|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency|(% style="width:452px" %)Frequency range: 0~~4000 139 -|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume|(% style="width:452px" %)Volume range: 0~~80 143 +|=(% style="width: 160px;" %)HSW1|(% style="width:282px" %)Beep frequency (Only valid in HMI V1.0 System)|(% style="width:452px" %)Frequency range: 0~~4000 144 +|=(% style="width: 160px;" %)HSW2|(% style="width:282px" %)Beep volume (Only valid in HMI V1.0 System)|(% style="width:452px" %)Volume range: 0~~80 140 140 |=(% style="width: 160px;" %)HSW3|(% style="width:282px" %)Beep time|(% style="width:452px" %)Unit: ms 141 141 |=(% style="width: 160px;" %)HSW4|(% style="width:282px" %)Beep whether enable or not|(% style="width:452px" %)((( 142 142 * =0: Enable. ... ... @@ -150,7 +150,7 @@ 150 150 ))) 151 151 |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed) 152 152 |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm 153 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)(((158 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)((( 154 154 * =0: Enable 155 155 * =1: Disable 156 156 ))) ... ... @@ -175,6 +175,7 @@ 175 175 * =5: Friday. 176 176 * =6: Saturday. 177 177 ))) 183 +|=(% style="width: 160px;" %)HSW39|(% style="width:282px" %)Beep type(Only valid in HMI V2.0 System)|(% style="width:452px" %)Type range: 1-5, Default is 1. 178 178 |=(% style="width: 160px;" %)HSW134|(% style="width:282px" %)((( 179 179 Whether the Script is read through 180 180 ... ... @@ -450,7 +450,7 @@ 450 450 Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms. 451 451 452 452 * When the set value is greater than 1000, the value is 1000. 453 -* When the set value is greater than1000, it changes to the default value 300459 +* When the set value is lower than 40, it changes to the default value 300 454 454 ))) 455 455 |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)((( 456 456 After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2. ... ... @@ -485,6 +485,8 @@ 485 485 * =0, Default value 486 486 * =1, Release the alarm generated before the last power-down when starting up 487 487 ))) 494 +|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 495 +|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 488 488 |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)((( 489 489 * =0, Disable 490 490 * =1, Enable ... ... @@ -591,6 +591,9 @@ 591 591 * =0: Server connection exception 592 592 * =1: Server connection is OK 593 593 ))) 602 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)((( 603 +Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890) 604 +))) 594 594 |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1 595 595 |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2 596 596 |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -790,6 +790,8 @@ 790 790 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 791 791 * =0: db database 792 792 * =1: CSV 804 + 805 +(Only valid for script function DbToCsvFile) 793 793 ))) 794 794 |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)((( 795 795 * =0: use the old high-low word conversion (default) ... ... @@ -816,7 +816,7 @@ 816 816 * =1: priority WLAN 817 817 * =2: priority 4G 818 818 ))) 819 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the L Ua extension module file|(% style="width:452px" %)(((832 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)((( 820 820 * =0: delete; 821 821 * = Others: do not delete 822 822 ))) ... ... @@ -885,13 +885,22 @@ 885 885 |=(% style="width: 160px;" %)((( 886 886 HSW1879 887 887 )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 901 +|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)((( 902 +* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval) 903 +* =Others: not refresh 904 +))) 905 +|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data |(% style="width:452px" %)((( 906 +* =1, not clear screen cache when switch language 907 +* =2, trigger clear cache of all screens for once time 908 +* =3, always clear cache of all screen data 909 +))) 888 888 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 889 889 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 890 890 Note: Valid when Ethernet1 of HMI is plugged into the network cable. 891 -① 、When the Ethernet setting is enabled in the project parameters, this register displays the set value.892 -② .When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.893 -③ .When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.894 -④ .IP related registers can be read and written (only static IP mode can be written).913 +① When the Ethernet setting is enabled in the project parameters, this register displays the set value. 914 +② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 915 +③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 916 +④ IP related registers can be read and written (only static IP mode can be written). 895 895 )))|(% style="width:452px" %)Local IP address high byte 1 896 896 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 897 897 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -917,7 +917,7 @@ 917 917 |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4 918 918 |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5 919 919 |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6 920 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC942 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 921 921 |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 922 922 |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password 923 923 |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
- 6.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.Mora - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.1 KB - Content