Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 16.1
edited by Hunter
on 2023/01/14 11:08
Change comment: There is no comment for this version
To version 16.3
edited by Hunter
on 2023/02/18 11:32
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -593,6 +593,9 @@
593 593  * =0: Server connection exception
594 594  * =1: Server connection is OK
595 595  )))
596 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal signal strength|(% style="width:452px" %)(((
597 +Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
598 +)))
596 596  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
597 597  |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2
598 598  |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -792,6 +792,8 @@
792 792  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
793 793  * =0: db database
794 794  * =1: CSV
798 +
799 +(Only valid for script function DbToCsvFile)
795 795  )))
796 796  |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
797 797  * =0: use the old high-low word conversion (default)
... ... @@ -818,9 +818,9 @@
818 818  * =1: priority WLAN
819 819  * =2: priority 4G
820 820  )))
821 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
826 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
822 822  * =0: delete;
823 -* = Others: do not delete
828 +* = Others value: do not delete
824 824  )))
825 825  |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
826 826  Monitor address is set during reset of reset switch, whether to cancel reset,