Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 16.1
edited by Hunter
on 2023/01/14 11:08
Change comment: There is no comment for this version
To version 5.1
edited by Stone Wu
on 2022/08/06 14:22
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Stone
Content
... ... @@ -4,11 +4,11 @@
4 4  
5 5  *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address.
6 6  
7 -* **System data area (HSW): **A special register defined by the system.
8 -* **Data storage area (HDW/HDX): **Users store user data.
9 -* **System data area (HUW): **A special register defined by the system.
10 -* **System Data (HAW)**: System register used for power-off save.
11 -* **Recipe index area (RPW): **System register used for recipe index.
7 +1. **System data area (HSW): **A special register defined by the system.
8 +1. **Data storage area (HDW/HDX): **Users store user data.
9 +1. **System data area (HUW): **A special register defined by the system.
10 +1. **System Data (HAW)**: System register used for power-off save.
11 +1. **Recipe index area (RPW): **System register used for recipe index.
12 12  
13 13  HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example).
14 14  
... ... @@ -241,8 +241,8 @@
241 241  * =2: HSX521.1=1, delete all trend graph.
242 242  * =4: HSX521.2=1, delete all alarms.
243 243  * =16: HSX521.4=1, delete history XY plot.
244 -* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting).
245 -* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting).
244 +* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting).
245 +* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting).
246 246  )))
247 247  |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)(((
248 248  * =0: No operation
... ... @@ -485,8 +485,6 @@
485 485  * =0, Default value
486 486  * =1, Release the alarm generated before the last power-down when starting up
487 487  )))
488 -|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
489 -|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
490 490  |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
491 491  * =0, Disable
492 492  * =1, Enable
... ... @@ -620,174 +620,6 @@
620 620  * =1: Server connection is OK
621 621  )))
622 622  |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger
623 -|=(% style="width: 160px;" %)(((
624 -HSW1762
625 -)))|(% colspan="1" rowspan="13" style="width:282px" %)(((
626 -Note: Valid when Ethernet2 of HMI is plugged into the network cable.
627 -①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
628 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
629 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
630 -④.IP related registers can be read and written (only static IP mode can be written).
631 -)))|(% style="width:452px" %)(((
632 -Ethernet2 Local IP address high byte 1
633 -)))
634 -|=(% style="width: 160px;" %)(((
635 -HSW1763
636 -)))|(% style="width:452px" %)(((
637 -Ethernet2 Local IP address high byte 2
638 -)))
639 -|=(% style="width: 160px;" %)(((
640 -HSW1764
641 -)))|(% style="width:452px" %)(((
642 -Ethernet2 Local IP address high byte 3
643 -)))
644 -|=(% style="width: 160px;" %)(((
645 -HSW1765
646 -)))|(% style="width:452px" %)(((
647 -Ethernet2 Local IP address high byte 4
648 -)))
649 -|=(% style="width: 160px;" %)(((
650 -HSW1766
651 -)))|(% style="width:452px" %)(((
652 -Ethernet2 Local mask IP address high byte 1
653 -)))
654 -|=(% style="width: 160px;" %)(((
655 -HSW1767
656 -)))|(% style="width:452px" %)(((
657 -Ethernet2 Local mask IP address high byte 2
658 -)))
659 -|=(% style="width: 160px;" %)(((
660 -HSW1768
661 -)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3
662 -|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4
663 -|=(% style="width: 160px;" %)(((
664 -HSW1770
665 -)))|(% style="width:452px" %)(((
666 -Ethernet2 Local gateway IP address high byte 1
667 -)))
668 -|=(% style="width: 160px;" %)(((
669 -HSW1771
670 -)))|(% style="width:452px" %)(((
671 -Ethernet2 Local gateway IP address high byte 2
672 -)))
673 -|=(% style="width: 160px;" %)(((
674 -HSW1772
675 -)))|(% style="width:452px" %)(((
676 -Ethernet2 Local gateway IP address high byte 3
677 -)))
678 -|=(% style="width: 160px;" %)(((
679 -HSW1773
680 -)))|(% style="width:452px" %)(((
681 -Ethernet2 Local gateway IP address high byte 4
682 -)))
683 -|=(% style="width: 160px;" %)(((
684 -HSW1774
685 -)))|(% style="width:452px" %)(((
686 -Ethernet2 Local Port Address
687 -)))
688 -|=(% style="width: 160px;" %)(((
689 -HSW1775
690 -)))|(% colspan="1" rowspan="6" style="width:282px" %)(((
691 -①Display the MAC code of Ethernet2 NIC
692 -
693 -(hexadecimal display)
694 -
695 -②Read-only mode, not modifiable
696 -)))|(% style="width:452px" %)(((
697 -Ethernet2 Local MAC code high byte 1
698 -)))
699 -|=(% style="width: 160px;" %)(((
700 -HSW1776
701 -)))|(% style="width:452px" %)(((
702 -Ethernet2 Local MAC code high byte 2
703 -)))
704 -|=(% style="width: 160px;" %)(((
705 -HSW1777
706 -)))|(% style="width:452px" %)(((
707 -Ethernet2 Local MAC code high byte 3
708 -)))
709 -|=(% style="width: 160px;" %)(((
710 -HSW1778
711 -)))|(% style="width:452px" %)(((
712 -Ethernet2 Local MAC code high byte 4
713 -)))
714 -|=(% style="width: 160px;" %)(((
715 -HSW1779
716 -)))|(% style="width:452px" %)(((
717 -Ethernet2 Local MAC code high byte 5
718 -)))
719 -|=(% style="width: 160px;" %)(((
720 -HSW1780
721 -)))|(% style="width:452px" %)(((
722 -Ethernet2 Local MAC code high byte 6
723 -)))
724 -|=(% style="width: 160px;" %)(((
725 -HSW1781
726 -)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
727 -①Display and modify DNS1 and DNS2 of Ethernet2
728 -
729 -②Related registers can be read and written mode (only static IP mode can be written)
730 -)))|(% style="width:452px" %)(((
731 -Ethernet2 Local DNS1 address high byte 1
732 -)))
733 -|=(% style="width: 160px;" %)(((
734 -HSW1782
735 -)))|(% style="width:452px" %)(((
736 -Ethernet2 Local DNS1 address high byte 2
737 -)))
738 -|=(% style="width: 160px;" %)(((
739 -HSW1783
740 -)))|(% style="width:452px" %)(((
741 -Ethernet2 Local DNS1 address high byte 3
742 -)))
743 -|=(% style="width: 160px;" %)(((
744 -HSW1784
745 -)))|(% style="width:452px" %)(((
746 -Ethernet2 Local DNS1 address high byte 4
747 -)))
748 -|=(% style="width: 160px;" %)(((
749 -HSW1785
750 -)))|(% style="width:452px" %)(((
751 -Ethernet2 Local DNS2 address high byte 1
752 -)))
753 -|=(% style="width: 160px;" %)(((
754 -HSW1786
755 -)))|(% style="width:452px" %)(((
756 -Ethernet2 Local DNS2 address high byte 2
757 -)))
758 -|=(% style="width: 160px;" %)(((
759 -HSW1787
760 -)))|(% style="width:452px" %)(((
761 -Ethernet2 Local DNS2 address high byte 3
762 -)))
763 -|=(% style="width: 160px;" %)(((
764 -HSW1788
765 -)))|(% style="width:452px" %)(((
766 -Ethernet2 Local DNS2 address high byte 4
767 -)))
768 -|=(% style="width: 160px;" %)(((
769 -HSW1789
770 -)))|(% colspan="1" style="width:282px" %)(((
771 -Display or set the dynamic or static IP mode of Ethernet2
772 -)))|(% style="width:452px" %)(((
773 -HSX1789.0 = 0, Static IP mode
774 -
775 -HSX1789.0 = 1, dynamic IP mode
776 -)))
777 -|=(% style="width: 160px;" %)(((
778 -HSW1790
779 -)))|(% colspan="1" style="width:282px" %)(((
780 -Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings
781 -)))|(% style="width:452px" %)(((
782 -~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
783 -)))
784 -|=(% style="width: 160px;" %)(((
785 -HSW1791
786 -)))|(% colspan="1" style="width:282px" %)(((
787 -Network status of the Ethernet2 connection server
788 -)))|(% style="width:452px" %)(((
789 -~= 0, connection to the server is abnormal = 1, connection to the server is normal
790 -)))
791 791  |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms.
792 792  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
793 793  * =0: db database
... ... @@ -813,87 +813,30 @@
813 813  * =1: download firmware
814 814  * =2: enter the background
815 815  )))
816 -|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)(((
817 -* =0: priority Ethernet
818 -* =1: priority WLAN
819 -* =2: priority 4G
820 -)))
821 821  |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
822 -* =0: delete;
823 -* = Others: do not delete
647 +* =1, delete;
648 +* = Others, do not delete
824 824  )))
825 825  |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
826 826  Monitor address is set during reset of reset switch, whether to cancel reset,
827 827  
828 -* = 0: yes (default);
829 -* = 1: no
653 +* = 0, yes (default);
654 +* = 1, no
830 830  )))
831 831  |=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)(((
832 832  Controls whether the button pops up when double-clicking or long pressing on record type table object
833 833  
834 -* = 0: yes (default);
835 -* = 1: no
659 +* = 0, yes (default);
660 +* = 1, no
836 836  )))
837 -|=(% style="width: 160px;" %)(((
838 -HSW1869
839 -)))|(% style="width:282px" %)(((
840 -Dynamic screensaver countdown
841 -)))|(% style="width:452px" %)(((
842 -Countdown to enter dynamic screensaver effect, unit (S)
843 -)))
844 -|=(% style="width: 160px;" %)(((
845 -HSW1870
846 -)))|(% style="width:282px" %)(((
847 -Display or set the dynamic or static IP mode of Ethernet1
848 -)))|(% style="width:452px" %)(((
849 -HSX1870.0 = 0, Static IP mode
850 -
851 -HSX1870.0 = 1, dynamic IP mode
852 -)))
853 -|=(% style="width: 160px;" %)(((
854 -HSW1871
855 -)))|(% style="width:282px" %)(((
856 -Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1
857 -)))|(% style="width:452px" %)(((
858 -~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0)
859 -)))
860 -|=(% style="width: 160px;" %)(((
861 -HSW1872
862 -)))|(% colspan="1" rowspan="8" style="width:282px" %)(((
863 -①Display and modify DNS1 and DNS2 of Ethernet1
864 -
865 -②Related registers can be read and written mode (only static IP mode can be written)
866 -)))|(% style="width:452px" %)(((
867 -Ethernet1 Local DNS1 address high byte 1
868 -)))
869 -|=(% style="width: 160px;" %)(((
870 -HSW1873
871 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2
872 -|=(% style="width: 160px;" %)(((
873 -HSW1874
874 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3
875 -|=(% style="width: 160px;" %)(((
876 -HSW1875
877 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4
878 -|=(% style="width: 160px;" %)(((
879 -HSW1876
880 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1
881 -|=(% style="width: 160px;" %)(((
882 -HSW1877
883 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2
884 -|=(% style="width: 160px;" %)(((
885 -HSW1878
886 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3
887 -|=(% style="width: 160px;" %)(((
888 -HSW1879
889 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
890 890  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
891 891  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
892 -Note: Valid when Ethernet1 of HMI is plugged into the network cable.
893 -①、When the Ethernet setting is enabled in the project parameters, this register displays the set value.
894 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.
895 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.
896 -④.IP related registers can be read and written (only static IP mode can be written).
664 +**✎Note: **Only valid when the HMI is plugged into the Ethernet cable.
665 +
666 +1. If Ethernet settings is enabled in project parameters, this register displays the set value.
667 +1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP.
668 +1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set.
669 +1. 4. All IP registers of HMI are read-only.
897 897  )))|(% style="width:452px" %)Local IP address high byte 1
898 898  |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2
899 899  |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -908,11 +908,9 @@
908 908  |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4
909 909  |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address
910 910  |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)(((
911 -Display the MAC code of Ethernet1 NIC
684 +Displays the MAC code of the current network card
912 912  
913 -(hexadecimal display)
914 -
915 -②Read-only mode, not modifiable
686 +(Hexadecimal display)
916 916  )))|(% style="width:452px" %)Local MAC code high word 1
917 917  |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2
918 918  |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3
... ... @@ -919,7 +919,7 @@
919 919  |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
920 920  |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
921 921  |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
922 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
693 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
923 923  |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
924 924  |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
925 925  |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
... ... @@ -1001,36 +1001,9 @@
1001 1001  )))
1002 1002  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
1003 1003  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1004 -|=(% style="width: 160px;" %)(((
1005 -HSW11762
1006 -)))|(% style="width:282px" %)(((
1007 -Dynamic screensaver control address
1008 -)))|(% style="width:452px" %)(((
1009 -HSX11762.0=0, initialize with project configuration;
1010 1010  
1011 -HSX11762.0=1, initialize with special register configuration;
776 +== **Serial port communication configuration** ==
1012 1012  
1013 -HSX11762.1=0, disable dynamic screensaver;
1014 -
1015 -HSX11762.1=1, enable dynamic screensaver
1016 -)))
1017 -|=(% style="width: 160px;" %)(((
1018 -HSW11763
1019 -)))|(% style="width:282px" %)(((
1020 -Waiting time to enter the dynamic screensaver
1021 -)))|(% style="width:452px" %)(((
1022 -Waiting time when the screen is not operated, range 1~~720 minutes
1023 -)))
1024 -|=(% style="width: 160px;" %)(((
1025 -HSW11764
1026 -)))|(% style="width:282px" %)(((
1027 -Animated screensaver animation type
1028 -)))|(% style="width:452px" %)(((
1029 -~=0: Raster,=1: Blinds,=2: Bubble
1030 -)))
1031 -
1032 -== Serial port communication configuration ==
1033 -
1034 1034  (% class="table-bordered" %)
1035 1035  |=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description**
1036 1036  |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)(((
... ... @@ -1062,22 +1062,10 @@
1062 1062  * =1: ODD
1063 1063  * =2: EVEN
1064 1064  )))
1065 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)(((
1066 -* Unit: ms.
1067 -* Range: 0 to 30000
1068 -)))
1069 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)(((
1070 -* Unit: ms.
1071 -* Range: 0 to 30000
1072 -)))
1073 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)(((
1074 -* Unit: times.
1075 -* Range: 0 to 100
1076 -)))
1077 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)(((
1078 -* Unit: s.
1079 -* Range: 0 to 300
1080 -)))
809 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
810 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
811 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
812 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300
1081 1081  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %)
1082 1082  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %)
1083 1083  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)(((
... ... @@ -1110,22 +1110,10 @@
1110 1110  * =1: ODD
1111 1111  * =2: EVEN
1112 1112  )))
1113 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)(((
1114 -* Unit: ms.
1115 -* Range: 0 to 30000
1116 -)))
1117 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)(((
1118 -* Unit: ms.
1119 -* Range: 0 to 30000
1120 -)))
1121 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)(((
1122 -* Unit: times.
1123 -* Range: 0 to 100
1124 -)))
1125 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)(((
1126 -* Unit: s.
1127 -* Range: 0 to 30
1128 -)))
845 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
846 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
847 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
848 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1129 1129  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %)
1130 1130  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %)
1131 1131  |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)(((
... ... @@ -1158,22 +1158,10 @@
1158 1158  * =1: ODD
1159 1159  * =2: EVEN
1160 1160  )))
1161 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)(((
1162 -* Unit: ms.
1163 -* Range: 0 to 30000
1164 -)))
1165 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)(((
1166 -* Unit: ms.
1167 -* Range: 0 to 30000
1168 -)))
1169 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)(((
1170 -* Unit: times.
1171 -* Range: 0 to 100
1172 -)))
1173 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)(((
1174 -* Unit: s.
1175 -* Range: 0 to 30
1176 -)))
881 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
882 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
883 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
884 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1177 1177  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %)
1178 1178  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %)
1179 1179  |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)(((
... ... @@ -1204,22 +1204,10 @@
1204 1204  * =1: ODD
1205 1205  * =2: EVEN
1206 1206  )))
1207 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)(((
1208 -* Unit: ms.
1209 -* Range: 0 to 30000
1210 -)))
1211 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)(((
1212 -* Unit: ms.
1213 -* Range: 0 to 30000
1214 -)))
1215 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)(((
1216 -* Unit: times.
1217 -* Range: 0 to 100
1218 -)))
1219 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)(((
1220 -* Unit: s.
1221 -* Range: 0 to 30
1222 -)))
915 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
916 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
917 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
918 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1223 1223  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %)
1224 1224  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %)
1225 1225  |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)(((
... ... @@ -1250,22 +1250,10 @@
1250 1250  * =1: ODD
1251 1251  * =2: EVEN
1252 1252  )))
1253 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)(((
1254 -* Unit: ms.
1255 -* Range: 0 to 30000
1256 -)))
1257 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)(((
1258 -* Unit: ms.
1259 -* Range: 0 to 30000
1260 -)))
1261 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)(((
1262 -* Unit: times.
1263 -* Range: 0 to 100
1264 -)))
1265 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)(((
1266 -* Unit: s.
1267 -* Range: 0 to 30
1268 -)))
949 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
950 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
951 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
952 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1269 1269  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %)
1270 1270  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %)
1271 1271  |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)(((
... ... @@ -1295,48 +1295,29 @@
1295 1295  * =1: ODD
1296 1296  * =2: EVEN
1297 1297  )))
1298 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)(((
1299 -* Unit: ms.
1300 -* Range: 0 to 30000
1301 -)))
1302 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)(((
1303 -* Unit: ms.
1304 -* Range: 0 to 30000
1305 -)))
1306 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)(((
1307 -* Unit: times.
1308 -* Range: 0 to 100
1309 -)))
1310 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)(((
1311 -* Unit: s.
1312 -* Range: 0 to 30
1313 -)))
982 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
983 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000
984 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100
985 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30
1314 1314  |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %)
1315 1315  |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %)
1316 1316  |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)(((
1317 -Unit: K, the baud rate must be an integer.
1318 -
1319 -For example, when the baud rate required is 250000, just enter 250.
989 +Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1320 1320  )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect.
1321 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)(((
1322 -Unit: K, the baud rate must be an integer.
991 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250.
1323 1323  
1324 -For example, when the baud rate required is 250000, just enter 250.
1325 -)))
993 +== **Ethernet communication configuration** ==
1326 1326  
1327 -== Ethernet communication configuration ==
1328 -
1329 1329  (% class="table-bordered" %)
1330 -|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description**
996 +|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description**
1331 1331  |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1
1332 1332  |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2
1333 1333  |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3
1334 1334  |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4
1335 1335  |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number
1336 -|(% style="width:220px" %)HSW11009|(% style="width:336px" %)(((
1337 -~=2 TCP
1338 -
1339 -~=3 UDP
1002 +|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)(((
1003 +* =2 TCP
1004 +* =3 UDP
1340 1340  )))
1341 1341  |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved
1342 1342  |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1
... ... @@ -1344,10 +1344,9 @@
1344 1344  |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3
1345 1345  |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4
1346 1346  |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number
1347 -|(% style="width:220px" %)HSW11016|(% style="width:336px" %)(((
1348 -~=2 TCP
1349 -
1350 -~=3 UDP
1012 +|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)(((
1013 +* =2 TCP
1014 +* =3 UDP
1351 1351  )))
1352 1352  |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved
1353 1353  |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)…
... ... @@ -1356,11 +1356,7 @@
1356 1356  |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3
1357 1357  |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4
1358 1358  |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number
1359 -|(% style="width:220px" %)HSW11226|(% style="width:336px" %)(((
1360 -~=2 TCP;
1361 -
1362 -~=3 UDP
1363 -)))
1023 +|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP
1364 1364  |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved
1365 1365  
1366 1366  (% class="box infomessage" %)
... ... @@ -1368,7 +1368,7 @@
1368 1368  **✎Note:** The number of Ethernet connections supported by different HMI series varies.
1369 1369  )))
1370 1370  
1371 -== Communication control ==
1031 +== **Communication control** ==
1372 1372  
1373 1373  (% class="table-bordered" %)
1374 1374  |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**