Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Stone - Content
-
... ... @@ -4,11 +4,11 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - ***System data area (HSW): **A special register defined by the system.8 - ***Data storage area (HDW/HDX): **Users store user data.9 - ***System data area (HUW): **A special register defined by the system.10 - ***System Data (HAW)**: System register used for power-off save.11 - ***Recipe index area (RPW): **System register used for recipe index.7 +1. **System data area (HSW): **A special register defined by the system. 8 +1. **Data storage area (HDW/HDX): **Users store user data. 9 +1. **System data area (HUW): **A special register defined by the system. 10 +1. **System Data (HAW)**: System register used for power-off save. 11 +1. **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 ... ... @@ -241,8 +241,8 @@ 241 241 * =2: HSX521.1=1, delete all trend graph. 242 242 * =4: HSX521.2=1, delete all alarms. 243 243 * =16: HSX521.4=1, delete history XY plot. 244 -* =32: HSX521.5=1, delete data records in SD card or USBflash disk;(Please make a setting which is saved toUSBflash disk or SD card in project setting).245 -* =64: HSX521.6=1, delete alarms records in SD card or USBflash disk; (Please make a setting which is saved toUSBflash disk or SD card in project setting).244 +* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting). 245 +* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting). 246 246 ))) 247 247 |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)((( 248 248 * =0: No operation ... ... @@ -485,8 +485,6 @@ 485 485 * =0, Default value 486 486 * =1, Release the alarm generated before the last power-down when starting up 487 487 ))) 488 -|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 489 -|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 490 490 |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)((( 491 491 * =0, Disable 492 492 * =1, Enable ... ... @@ -620,174 +620,6 @@ 620 620 * =1: Server connection is OK 621 621 ))) 622 622 |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger 623 -|=(% style="width: 160px;" %)((( 624 -HSW1762 625 -)))|(% colspan="1" rowspan="13" style="width:282px" %)((( 626 -Note: Valid when Ethernet2 of HMI is plugged into the network cable. 627 -①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 628 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 629 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 630 -④.IP related registers can be read and written (only static IP mode can be written). 631 -)))|(% style="width:452px" %)((( 632 -Ethernet2 Local IP address high byte 1 633 -))) 634 -|=(% style="width: 160px;" %)((( 635 -HSW1763 636 -)))|(% style="width:452px" %)((( 637 -Ethernet2 Local IP address high byte 2 638 -))) 639 -|=(% style="width: 160px;" %)((( 640 -HSW1764 641 -)))|(% style="width:452px" %)((( 642 -Ethernet2 Local IP address high byte 3 643 -))) 644 -|=(% style="width: 160px;" %)((( 645 -HSW1765 646 -)))|(% style="width:452px" %)((( 647 -Ethernet2 Local IP address high byte 4 648 -))) 649 -|=(% style="width: 160px;" %)((( 650 -HSW1766 651 -)))|(% style="width:452px" %)((( 652 -Ethernet2 Local mask IP address high byte 1 653 -))) 654 -|=(% style="width: 160px;" %)((( 655 -HSW1767 656 -)))|(% style="width:452px" %)((( 657 -Ethernet2 Local mask IP address high byte 2 658 -))) 659 -|=(% style="width: 160px;" %)((( 660 -HSW1768 661 -)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3 662 -|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4 663 -|=(% style="width: 160px;" %)((( 664 -HSW1770 665 -)))|(% style="width:452px" %)((( 666 -Ethernet2 Local gateway IP address high byte 1 667 -))) 668 -|=(% style="width: 160px;" %)((( 669 -HSW1771 670 -)))|(% style="width:452px" %)((( 671 -Ethernet2 Local gateway IP address high byte 2 672 -))) 673 -|=(% style="width: 160px;" %)((( 674 -HSW1772 675 -)))|(% style="width:452px" %)((( 676 -Ethernet2 Local gateway IP address high byte 3 677 -))) 678 -|=(% style="width: 160px;" %)((( 679 -HSW1773 680 -)))|(% style="width:452px" %)((( 681 -Ethernet2 Local gateway IP address high byte 4 682 -))) 683 -|=(% style="width: 160px;" %)((( 684 -HSW1774 685 -)))|(% style="width:452px" %)((( 686 -Ethernet2 Local Port Address 687 -))) 688 -|=(% style="width: 160px;" %)((( 689 -HSW1775 690 -)))|(% colspan="1" rowspan="6" style="width:282px" %)((( 691 -①Display the MAC code of Ethernet2 NIC 692 - 693 -(hexadecimal display) 694 - 695 -②Read-only mode, not modifiable 696 -)))|(% style="width:452px" %)((( 697 -Ethernet2 Local MAC code high byte 1 698 -))) 699 -|=(% style="width: 160px;" %)((( 700 -HSW1776 701 -)))|(% style="width:452px" %)((( 702 -Ethernet2 Local MAC code high byte 2 703 -))) 704 -|=(% style="width: 160px;" %)((( 705 -HSW1777 706 -)))|(% style="width:452px" %)((( 707 -Ethernet2 Local MAC code high byte 3 708 -))) 709 -|=(% style="width: 160px;" %)((( 710 -HSW1778 711 -)))|(% style="width:452px" %)((( 712 -Ethernet2 Local MAC code high byte 4 713 -))) 714 -|=(% style="width: 160px;" %)((( 715 -HSW1779 716 -)))|(% style="width:452px" %)((( 717 -Ethernet2 Local MAC code high byte 5 718 -))) 719 -|=(% style="width: 160px;" %)((( 720 -HSW1780 721 -)))|(% style="width:452px" %)((( 722 -Ethernet2 Local MAC code high byte 6 723 -))) 724 -|=(% style="width: 160px;" %)((( 725 -HSW1781 726 -)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 727 -①Display and modify DNS1 and DNS2 of Ethernet2 728 - 729 -②Related registers can be read and written mode (only static IP mode can be written) 730 -)))|(% style="width:452px" %)((( 731 -Ethernet2 Local DNS1 address high byte 1 732 -))) 733 -|=(% style="width: 160px;" %)((( 734 -HSW1782 735 -)))|(% style="width:452px" %)((( 736 -Ethernet2 Local DNS1 address high byte 2 737 -))) 738 -|=(% style="width: 160px;" %)((( 739 -HSW1783 740 -)))|(% style="width:452px" %)((( 741 -Ethernet2 Local DNS1 address high byte 3 742 -))) 743 -|=(% style="width: 160px;" %)((( 744 -HSW1784 745 -)))|(% style="width:452px" %)((( 746 -Ethernet2 Local DNS1 address high byte 4 747 -))) 748 -|=(% style="width: 160px;" %)((( 749 -HSW1785 750 -)))|(% style="width:452px" %)((( 751 -Ethernet2 Local DNS2 address high byte 1 752 -))) 753 -|=(% style="width: 160px;" %)((( 754 -HSW1786 755 -)))|(% style="width:452px" %)((( 756 -Ethernet2 Local DNS2 address high byte 2 757 -))) 758 -|=(% style="width: 160px;" %)((( 759 -HSW1787 760 -)))|(% style="width:452px" %)((( 761 -Ethernet2 Local DNS2 address high byte 3 762 -))) 763 -|=(% style="width: 160px;" %)((( 764 -HSW1788 765 -)))|(% style="width:452px" %)((( 766 -Ethernet2 Local DNS2 address high byte 4 767 -))) 768 -|=(% style="width: 160px;" %)((( 769 -HSW1789 770 -)))|(% colspan="1" style="width:282px" %)((( 771 -Display or set the dynamic or static IP mode of Ethernet2 772 -)))|(% style="width:452px" %)((( 773 -HSX1789.0 = 0, Static IP mode 774 - 775 -HSX1789.0 = 1, dynamic IP mode 776 -))) 777 -|=(% style="width: 160px;" %)((( 778 -HSW1790 779 -)))|(% colspan="1" style="width:282px" %)((( 780 -Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings 781 -)))|(% style="width:452px" %)((( 782 -~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 783 -))) 784 -|=(% style="width: 160px;" %)((( 785 -HSW1791 786 -)))|(% colspan="1" style="width:282px" %)((( 787 -Network status of the Ethernet2 connection server 788 -)))|(% style="width:452px" %)((( 789 -~= 0, connection to the server is abnormal = 1, connection to the server is normal 790 -))) 791 791 |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms. 792 792 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 793 793 * =0: db database ... ... @@ -813,87 +813,30 @@ 813 813 * =1: download firmware 814 814 * =2: enter the background 815 815 ))) 816 -|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)((( 817 -* =0: priority Ethernet 818 -* =1: priority WLAN 819 -* =2: priority 4G 820 -))) 821 821 |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 822 -* = 0:delete;823 -* = Others :do not delete647 +* =1, delete; 648 +* = Others, do not delete 824 824 ))) 825 825 |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 826 826 Monitor address is set during reset of reset switch, whether to cancel reset, 827 827 828 -* = 0 :yes (default);829 -* = 1 :no653 +* = 0, yes (default); 654 +* = 1, no 830 830 ))) 831 831 |=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 832 832 Controls whether the button pops up when double-clicking or long pressing on record type table object 833 833 834 -* = 0 :yes (default);835 -* = 1 :no659 +* = 0, yes (default); 660 +* = 1, no 836 836 ))) 837 -|=(% style="width: 160px;" %)((( 838 -HSW1869 839 -)))|(% style="width:282px" %)((( 840 -Dynamic screensaver countdown 841 -)))|(% style="width:452px" %)((( 842 -Countdown to enter dynamic screensaver effect, unit (S) 843 -))) 844 -|=(% style="width: 160px;" %)((( 845 -HSW1870 846 -)))|(% style="width:282px" %)((( 847 -Display or set the dynamic or static IP mode of Ethernet1 848 -)))|(% style="width:452px" %)((( 849 -HSX1870.0 = 0, Static IP mode 850 - 851 -HSX1870.0 = 1, dynamic IP mode 852 -))) 853 -|=(% style="width: 160px;" %)((( 854 -HSW1871 855 -)))|(% style="width:282px" %)((( 856 -Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1 857 -)))|(% style="width:452px" %)((( 858 -~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 859 -))) 860 -|=(% style="width: 160px;" %)((( 861 -HSW1872 862 -)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 863 -①Display and modify DNS1 and DNS2 of Ethernet1 864 - 865 -②Related registers can be read and written mode (only static IP mode can be written) 866 -)))|(% style="width:452px" %)((( 867 -Ethernet1 Local DNS1 address high byte 1 868 -))) 869 -|=(% style="width: 160px;" %)((( 870 -HSW1873 871 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2 872 -|=(% style="width: 160px;" %)((( 873 -HSW1874 874 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3 875 -|=(% style="width: 160px;" %)((( 876 -HSW1875 877 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4 878 -|=(% style="width: 160px;" %)((( 879 -HSW1876 880 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1 881 -|=(% style="width: 160px;" %)((( 882 -HSW1877 883 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2 884 -|=(% style="width: 160px;" %)((( 885 -HSW1878 886 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3 887 -|=(% style="width: 160px;" %)((( 888 -HSW1879 889 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 890 890 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 891 891 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 892 -Note: Valid when Ethernet1 of HMI is plugged into the network cable. 893 -①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 894 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 895 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 896 -④.IP related registers can be read and written (only static IP mode can be written). 664 +**✎Note: **Only valid when the HMI is plugged into the Ethernet cable. 665 + 666 +1. If Ethernet settings is enabled in project parameters, this register displays the set value. 667 +1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP. 668 +1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set. 669 +1. 4. All IP registers of HMI are read-only. 897 897 )))|(% style="width:452px" %)Local IP address high byte 1 898 898 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 899 899 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -908,11 +908,9 @@ 908 908 |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4 909 909 |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address 910 910 |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)((( 911 - ①Display the MAC code ofEthernet1NIC684 +Displays the MAC code of the current network card 912 912 913 -(hexadecimal display) 914 - 915 -②Read-only mode, not modifiable 686 +(Hexadecimal display) 916 916 )))|(% style="width:452px" %)Local MAC code high word 1 917 917 |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2 918 918 |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3 ... ... @@ -919,7 +919,7 @@ 919 919 |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4 920 920 |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5 921 921 |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6 922 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC693 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 923 923 |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 924 924 |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password 925 925 |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit) ... ... @@ -1001,36 +1001,9 @@ 1001 1001 ))) 1002 1002 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 1003 1003 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 1004 -|=(% style="width: 160px;" %)((( 1005 -HSW11762 1006 -)))|(% style="width:282px" %)((( 1007 -Dynamic screensaver control address 1008 -)))|(% style="width:452px" %)((( 1009 -HSX11762.0=0, initialize with project configuration; 1010 1010 1011 - HSX11762.0=1,initializewithspecial registerconfiguration;776 +== **Serial port communication configuration** == 1012 1012 1013 -HSX11762.1=0, disable dynamic screensaver; 1014 - 1015 -HSX11762.1=1, enable dynamic screensaver 1016 -))) 1017 -|=(% style="width: 160px;" %)((( 1018 -HSW11763 1019 -)))|(% style="width:282px" %)((( 1020 -Waiting time to enter the dynamic screensaver 1021 -)))|(% style="width:452px" %)((( 1022 -Waiting time when the screen is not operated, range 1~~720 minutes 1023 -))) 1024 -|=(% style="width: 160px;" %)((( 1025 -HSW11764 1026 -)))|(% style="width:282px" %)((( 1027 -Animated screensaver animation type 1028 -)))|(% style="width:452px" %)((( 1029 -~=0: Raster,=1: Blinds,=2: Bubble 1030 -))) 1031 - 1032 -== Serial port communication configuration == 1033 - 1034 1034 (% class="table-bordered" %) 1035 1035 |=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 1036 1036 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( ... ... @@ -1062,22 +1062,10 @@ 1062 1062 * =1: ODD 1063 1063 * =2: EVEN 1064 1064 ))) 1065 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)((( 1066 -* Unit: ms. 1067 -* Range: 0 to 30000 1068 -))) 1069 -|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)((( 1070 -* Unit: ms. 1071 -* Range: 0 to 30000 1072 -))) 1073 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)((( 1074 -* Unit: times. 1075 -* Range: 0 to 100 1076 -))) 1077 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)((( 1078 -* Unit: s. 1079 -* Range: 0 to 300 1080 -))) 809 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10066|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 810 +|(% style="width:173px" %)reveive timeout|(% style="width:122px" %)HSW10067|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 811 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10068|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 812 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10069|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~300 1081 1081 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10070|(% colspan="2" style="width:506px" %) 1082 1082 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10071|(% colspan="2" style="width:506px" %) 1083 1083 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10094|(% colspan="2" style="width:506px" %)((( ... ... @@ -1110,22 +1110,10 @@ 1110 1110 * =1: ODD 1111 1111 * =2: EVEN 1112 1112 ))) 1113 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)((( 1114 -* Unit: ms. 1115 -* Range: 0 to 30000 1116 -))) 1117 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)((( 1118 -* Unit: ms. 1119 -* Range: 0 to 30000 1120 -))) 1121 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)((( 1122 -* Unit: times. 1123 -* Range: 0 to 100 1124 -))) 1125 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)((( 1126 -* Unit: s. 1127 -* Range: 0 to 30 1128 -))) 845 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10099|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 846 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10100|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 847 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10101|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 848 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10102|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1129 1129 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10103|(% colspan="2" style="width:506px" %) 1130 1130 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10104|(% colspan="2" style="width:506px" %) 1131 1131 |(% colspan="1" rowspan="11" style="width:102px" %)COM1-3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10120|(% colspan="2" style="width:506px" %)((( ... ... @@ -1158,22 +1158,10 @@ 1158 1158 * =1: ODD 1159 1159 * =2: EVEN 1160 1160 ))) 1161 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)((( 1162 -* Unit: ms. 1163 -* Range: 0 to 30000 1164 -))) 1165 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)((( 1166 -* Unit: ms. 1167 -* Range: 0 to 30000 1168 -))) 1169 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)((( 1170 -* Unit: times. 1171 -* Range: 0 to 100 1172 -))) 1173 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)((( 1174 -* Unit: s. 1175 -* Range: 0 to 30 1176 -))) 881 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10125|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 882 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10126|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 883 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10127|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 884 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10128|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1177 1177 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10129|(% colspan="2" style="width:506px" %) 1178 1178 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10130|(% colspan="2" style="width:506px" %) 1179 1179 |(% colspan="1" rowspan="11" style="width:102px" %)COM2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10072|(% colspan="2" style="width:506px" %)((( ... ... @@ -1204,22 +1204,10 @@ 1204 1204 * =1: ODD 1205 1205 * =2: EVEN 1206 1206 ))) 1207 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)((( 1208 -* Unit: ms. 1209 -* Range: 0 to 30000 1210 -))) 1211 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)((( 1212 -* Unit: ms. 1213 -* Range: 0 to 30000 1214 -))) 1215 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)((( 1216 -* Unit: times. 1217 -* Range: 0 to 100 1218 -))) 1219 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)((( 1220 -* Unit: s. 1221 -* Range: 0 to 30 1222 -))) 915 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10077|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 916 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10078|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 917 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10079|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 918 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10080|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1223 1223 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10081|(% colspan="2" style="width:506px" %) 1224 1224 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10082|(% colspan="2" style="width:506px" %) 1225 1225 |(% colspan="1" rowspan="11" style="width:102px" %)COM2-2|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10105|(% colspan="2" style="width:506px" %)((( ... ... @@ -1250,22 +1250,10 @@ 1250 1250 * =1: ODD 1251 1251 * =2: EVEN 1252 1252 ))) 1253 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)((( 1254 -* Unit: ms. 1255 -* Range: 0 to 30000 1256 -))) 1257 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)((( 1258 -* Unit: ms. 1259 -* Range: 0 to 30000 1260 -))) 1261 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)((( 1262 -* Unit: times. 1263 -* Range: 0 to 100 1264 -))) 1265 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)((( 1266 -* Unit: s. 1267 -* Range: 0 to 30 1268 -))) 949 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10110|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 950 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10111|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 951 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10112|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 952 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10113|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1269 1269 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10114|(% colspan="2" style="width:506px" %) 1270 1270 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10115|(% colspan="2" style="width:506px" %) 1271 1271 |(% colspan="1" rowspan="11" style="width:102px" %)COM3|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10083|(% colspan="2" style="width:506px" %)((( ... ... @@ -1295,48 +1295,29 @@ 1295 1295 * =1: ODD 1296 1296 * =2: EVEN 1297 1297 ))) 1298 -|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)((( 1299 -* Unit: ms. 1300 -* Range: 0 to 30000 1301 -))) 1302 -|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)((( 1303 -* Unit: ms. 1304 -* Range: 0 to 30000 1305 -))) 1306 -|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)((( 1307 -* Unit: times. 1308 -* Range: 0 to 100 1309 -))) 1310 -|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)((( 1311 -* Unit: s. 1312 -* Range: 0 to 30 1313 -))) 982 +|(% style="width:173px" %)Wait timeout|(% style="width:122px" %)HSW10088|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 983 +|(% style="width:173px" %)receive timeout|(% style="width:122px" %)HSW10089|(% colspan="2" style="width:506px" %)Unit: ms. Range: 0~~30000 984 +|(% style="width:173px" %)Retry time|(% style="width:122px" %)HSW10090|(% colspan="2" style="width:506px" %)Unit: times. Range: 0~~100 985 +|(% style="width:173px" %)Retry timeout|(% style="width:122px" %)HSW10091|(% colspan="2" style="width:506px" %)Unit: s. Range: 0~~30 1314 1314 |(% style="width:173px" %)HMI station number|(% style="width:122px" %)HSW10092|(% colspan="2" style="width:506px" %) 1315 1315 |(% style="width:173px" %)PLC station number|(% style="width:122px" %)HSW10093|(% colspan="2" style="width:506px" %) 1316 1316 |(% colspan="1" rowspan="2" style="width:102px" %)CAN port|(% style="width:173px" %)CAN1 baud rate|(% style="width:122px" %)HSW010116|(% style="width:299px" %)((( 1317 -Unit: K, the baud rate must be an integer. 1318 - 1319 -For example, when the baud rate required is 250000, just enter 250. 989 +Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1320 1320 )))|(% colspan="1" rowspan="2" style="width:218px" %)**✎Note: **If baud rate has been modified,please wait 5 seconds,then restart the HMI to take effect. 1321 -|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)((( 1322 -Unit: K, the baud rate must be an integer. 991 +|(% style="width:173px" %)CAN2 baud rate|(% style="width:122px" %)HSW010117|(% style="width:299px" %)Unit: K, the baud rate must be an integer, for example, when the baud rate required is 250000, just enter 250. 1323 1323 1324 -For example, when the baud rate required is 250000, just enter 250. 1325 -))) 993 +== **Ethernet communication configuration** == 1326 1326 1327 -== Ethernet communication configuration == 1328 - 1329 1329 (% class="table-bordered" %) 1330 -|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description** 996 +|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description** 1331 1331 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 1332 1332 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2 1333 1333 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3 1334 1334 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4 1335 1335 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number 1336 -|(% style="width:220px" %)HSW11009|(% style="width:336px" %)((( 1337 -~=2 TCP 1338 - 1339 -~=3 UDP 1002 +|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)((( 1003 +* =2 TCP 1004 +* =3 UDP 1340 1340 ))) 1341 1341 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved 1342 1342 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -1344,10 +1344,9 @@ 1344 1344 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3 1345 1345 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4 1346 1346 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number 1347 -|(% style="width:220px" %)HSW11016|(% style="width:336px" %)((( 1348 -~=2 TCP 1349 - 1350 -~=3 UDP 1012 +|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)((( 1013 +* =2 TCP 1014 +* =3 UDP 1351 1351 ))) 1352 1352 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved 1353 1353 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)… ... ... @@ -1356,11 +1356,7 @@ 1356 1356 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3 1357 1357 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4 1358 1358 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number 1359 -|(% style="width:220px" %)HSW11226|(% style="width:336px" %)((( 1360 -~=2 TCP; 1361 - 1362 -~=3 UDP 1363 -))) 1023 +|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 1364 1364 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 1365 1365 1366 1366 (% class="box infomessage" %) ... ... @@ -1368,7 +1368,7 @@ 1368 1368 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1369 1369 ))) 1370 1370 1371 -== Communication control == 1031 +== **Communication control** == 1372 1372 1373 1373 (% class="table-bordered" %) 1374 1374 |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**