... ... @@ -593,7 +593,7 @@
593 593  * =0: Server connection exception
594 594  * =1: Server connection is OK
595 595  )))
596 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal signal strength|(% style="width:452px" %)(((
596 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)(((
597 597  Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
598 598  )))
599 599  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
... ... @@ -795,6 +795,8 @@
795 795  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
796 796  * =0: db database
797 797  * =1: CSV
798 +
799 +(Only valid for script function DbToCsvFile)
798 798  )))
799 799  |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
800 800  * =0: use the old high-low word conversion (default)
... ... @@ -821,7 +821,7 @@
821 821  * =1: priority WLAN
822 822  * =2: priority 4G
823 823  )))
824 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
826 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
825 825  * =0: delete;
826 826  * = Others: do not delete
827 827  )))
... ... @@ -890,6 +890,15 @@
890 890  |=(% style="width: 160px;" %)(((
891 891  HSW1879
892 892  )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
895 +|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)(((
896 +* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval)
897 +* =Others: not refresh
898 +)))
899 +|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data  |(% style="width:452px" %)(((
900 +* =1, not clear screen cache when switch language
901 +* =2, trigger clear cache of all screens for once time
902 +* =3, always clear cache of all screen data
903 +)))
893 893  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
894 894  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
895 895  Note: Valid when Ethernet1 of HMI is plugged into the network cable.