Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Author
-
... ... @@ -1,1 +1,1 @@ 1 -XWiki. Hunter1 +XWiki.Stone - Content
-
... ... @@ -4,11 +4,11 @@ 4 4 5 5 *HSW, HDW, HUW, HAW are word address, HSX, HDX, HUX, HAX are bit address. 6 6 7 - ***System data area (HSW): **A special register defined by the system.8 - ***Data storage area (HDW/HDX): **Users store user data.9 - ***System data area (HUW): **A special register defined by the system.10 - ***System Data (HAW)**: System register used for power-off save.11 - ***Recipe index area (RPW): **System register used for recipe index.7 +1. **System data area (HSW): **A special register defined by the system. 8 +1. **Data storage area (HDW/HDX): **Users store user data. 9 +1. **System data area (HUW): **A special register defined by the system. 10 +1. **System Data (HAW)**: System register used for power-off save. 11 +1. **Recipe index area (RPW): **System register used for recipe index. 12 12 13 13 HMI internal registers are divided into bit address and word address, which can be accessed in two ways (take HDW as an example). 14 14 ... ... @@ -241,8 +241,8 @@ 241 241 * =2: HSX521.1=1, delete all trend graph. 242 242 * =4: HSX521.2=1, delete all alarms. 243 243 * =16: HSX521.4=1, delete history XY plot. 244 -* =32: HSX521.5=1, delete data records in SD card or USBflash disk;(Please make a setting which is saved toUSBflash disk or SD card in project setting).245 -* =64: HSX521.6=1, delete alarms records in SD card or USBflash disk; (Please make a setting which is saved toUSBflash disk or SD card in project setting).244 +* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting). 245 +* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting). 246 246 ))) 247 247 |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)((( 248 248 * =0: No operation ... ... @@ -485,8 +485,6 @@ 485 485 * =0, Default value 486 486 * =1, Release the alarm generated before the last power-down when starting up 487 487 ))) 488 -|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 489 -|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 490 490 |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)((( 491 491 * =0, Disable 492 492 * =1, Enable ... ... @@ -593,9 +593,6 @@ 593 593 * =0: Server connection exception 594 594 * =1: Server connection is OK 595 595 ))) 596 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal signal strength|(% style="width:452px" %)((( 597 -Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890) 598 -))) 599 599 |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1 600 600 |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2 601 601 |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -623,174 +623,6 @@ 623 623 * =1: Server connection is OK 624 624 ))) 625 625 |=(% style="width: 160px;" %)HSW1761|(% style="width:282px" %)Display 4G network signal strength|(% style="width:452px" %)Signal strength: 0~~31. The greater the value ,the signal is stronger 626 -|=(% style="width: 160px;" %)((( 627 -HSW1762 628 -)))|(% colspan="1" rowspan="13" style="width:282px" %)((( 629 -Note: Valid when Ethernet2 of HMI is plugged into the network cable. 630 -①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 631 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 632 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 633 -④.IP related registers can be read and written (only static IP mode can be written). 634 -)))|(% style="width:452px" %)((( 635 -Ethernet2 Local IP address high byte 1 636 -))) 637 -|=(% style="width: 160px;" %)((( 638 -HSW1763 639 -)))|(% style="width:452px" %)((( 640 -Ethernet2 Local IP address high byte 2 641 -))) 642 -|=(% style="width: 160px;" %)((( 643 -HSW1764 644 -)))|(% style="width:452px" %)((( 645 -Ethernet2 Local IP address high byte 3 646 -))) 647 -|=(% style="width: 160px;" %)((( 648 -HSW1765 649 -)))|(% style="width:452px" %)((( 650 -Ethernet2 Local IP address high byte 4 651 -))) 652 -|=(% style="width: 160px;" %)((( 653 -HSW1766 654 -)))|(% style="width:452px" %)((( 655 -Ethernet2 Local mask IP address high byte 1 656 -))) 657 -|=(% style="width: 160px;" %)((( 658 -HSW1767 659 -)))|(% style="width:452px" %)((( 660 -Ethernet2 Local mask IP address high byte 2 661 -))) 662 -|=(% style="width: 160px;" %)((( 663 -HSW1768 664 -)))|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 3 665 -|=(% style="width: 160px;" %)HSW1769|(% style="width:452px" %)Ethernet2 Local mask IP address high byte 4 666 -|=(% style="width: 160px;" %)((( 667 -HSW1770 668 -)))|(% style="width:452px" %)((( 669 -Ethernet2 Local gateway IP address high byte 1 670 -))) 671 -|=(% style="width: 160px;" %)((( 672 -HSW1771 673 -)))|(% style="width:452px" %)((( 674 -Ethernet2 Local gateway IP address high byte 2 675 -))) 676 -|=(% style="width: 160px;" %)((( 677 -HSW1772 678 -)))|(% style="width:452px" %)((( 679 -Ethernet2 Local gateway IP address high byte 3 680 -))) 681 -|=(% style="width: 160px;" %)((( 682 -HSW1773 683 -)))|(% style="width:452px" %)((( 684 -Ethernet2 Local gateway IP address high byte 4 685 -))) 686 -|=(% style="width: 160px;" %)((( 687 -HSW1774 688 -)))|(% style="width:452px" %)((( 689 -Ethernet2 Local Port Address 690 -))) 691 -|=(% style="width: 160px;" %)((( 692 -HSW1775 693 -)))|(% colspan="1" rowspan="6" style="width:282px" %)((( 694 -①Display the MAC code of Ethernet2 NIC 695 - 696 -(hexadecimal display) 697 - 698 -②Read-only mode, not modifiable 699 -)))|(% style="width:452px" %)((( 700 -Ethernet2 Local MAC code high byte 1 701 -))) 702 -|=(% style="width: 160px;" %)((( 703 -HSW1776 704 -)))|(% style="width:452px" %)((( 705 -Ethernet2 Local MAC code high byte 2 706 -))) 707 -|=(% style="width: 160px;" %)((( 708 -HSW1777 709 -)))|(% style="width:452px" %)((( 710 -Ethernet2 Local MAC code high byte 3 711 -))) 712 -|=(% style="width: 160px;" %)((( 713 -HSW1778 714 -)))|(% style="width:452px" %)((( 715 -Ethernet2 Local MAC code high byte 4 716 -))) 717 -|=(% style="width: 160px;" %)((( 718 -HSW1779 719 -)))|(% style="width:452px" %)((( 720 -Ethernet2 Local MAC code high byte 5 721 -))) 722 -|=(% style="width: 160px;" %)((( 723 -HSW1780 724 -)))|(% style="width:452px" %)((( 725 -Ethernet2 Local MAC code high byte 6 726 -))) 727 -|=(% style="width: 160px;" %)((( 728 -HSW1781 729 -)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 730 -①Display and modify DNS1 and DNS2 of Ethernet2 731 - 732 -②Related registers can be read and written mode (only static IP mode can be written) 733 -)))|(% style="width:452px" %)((( 734 -Ethernet2 Local DNS1 address high byte 1 735 -))) 736 -|=(% style="width: 160px;" %)((( 737 -HSW1782 738 -)))|(% style="width:452px" %)((( 739 -Ethernet2 Local DNS1 address high byte 2 740 -))) 741 -|=(% style="width: 160px;" %)((( 742 -HSW1783 743 -)))|(% style="width:452px" %)((( 744 -Ethernet2 Local DNS1 address high byte 3 745 -))) 746 -|=(% style="width: 160px;" %)((( 747 -HSW1784 748 -)))|(% style="width:452px" %)((( 749 -Ethernet2 Local DNS1 address high byte 4 750 -))) 751 -|=(% style="width: 160px;" %)((( 752 -HSW1785 753 -)))|(% style="width:452px" %)((( 754 -Ethernet2 Local DNS2 address high byte 1 755 -))) 756 -|=(% style="width: 160px;" %)((( 757 -HSW1786 758 -)))|(% style="width:452px" %)((( 759 -Ethernet2 Local DNS2 address high byte 2 760 -))) 761 -|=(% style="width: 160px;" %)((( 762 -HSW1787 763 -)))|(% style="width:452px" %)((( 764 -Ethernet2 Local DNS2 address high byte 3 765 -))) 766 -|=(% style="width: 160px;" %)((( 767 -HSW1788 768 -)))|(% style="width:452px" %)((( 769 -Ethernet2 Local DNS2 address high byte 4 770 -))) 771 -|=(% style="width: 160px;" %)((( 772 -HSW1789 773 -)))|(% colspan="1" style="width:282px" %)((( 774 -Display or set the dynamic or static IP mode of Ethernet2 775 -)))|(% style="width:452px" %)((( 776 -HSX1789.0 = 0, Static IP mode 777 - 778 -HSX1789.0 = 1, dynamic IP mode 779 -))) 780 -|=(% style="width: 160px;" %)((( 781 -HSW1790 782 -)))|(% colspan="1" style="width:282px" %)((( 783 -Confirm Ethernet2 IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings 784 -)))|(% style="width:452px" %)((( 785 -~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 786 -))) 787 -|=(% style="width: 160px;" %)((( 788 -HSW1791 789 -)))|(% colspan="1" style="width:282px" %)((( 790 -Network status of the Ethernet2 connection server 791 -)))|(% style="width:452px" %)((( 792 -~= 0, connection to the server is abnormal = 1, connection to the server is normal 793 -))) 794 794 |=(% style="width: 160px;" %)HSW1852|(% style="width:282px" %)Control the interval in two consecutive clicks|(% style="width:452px" %)Limit range: 1~~500ms. The default is 100 ms. 795 795 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 796 796 * =0: db database ... ... @@ -816,87 +816,30 @@ 816 816 * =1: download firmware 817 817 * =2: enter the background 818 818 ))) 819 -|=(% style="width: 160px;" %)HSW1865|(% style="width:282px" %)Priority connection to the cloud|(% style="width:452px" %)((( 820 -* =0: priority Ethernet 821 -* =1: priority WLAN 822 -* =2: priority 4G 823 -))) 824 824 |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 825 -* = 0:delete;826 -* = Others :do not delete647 +* =1, delete; 648 +* = Others, do not delete 827 827 ))) 828 828 |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 829 829 Monitor address is set during reset of reset switch, whether to cancel reset, 830 830 831 -* = 0 :yes (default);832 -* = 1 :no653 +* = 0, yes (default); 654 +* = 1, no 833 833 ))) 834 834 |=(% style="width: 160px;" %)HSW1868|(% style="width:282px" %)Double-click or long press the record type table mode|(% style="width:452px" %)((( 835 835 Controls whether the button pops up when double-clicking or long pressing on record type table object 836 836 837 -* = 0 :yes (default);838 -* = 1 :no659 +* = 0, yes (default); 660 +* = 1, no 839 839 ))) 840 -|=(% style="width: 160px;" %)((( 841 -HSW1869 842 -)))|(% style="width:282px" %)((( 843 -Dynamic screensaver countdown 844 -)))|(% style="width:452px" %)((( 845 -Countdown to enter dynamic screensaver effect, unit (S) 846 -))) 847 -|=(% style="width: 160px;" %)((( 848 -HSW1870 849 -)))|(% style="width:282px" %)((( 850 -Display or set the dynamic or static IP mode of Ethernet1 851 -)))|(% style="width:452px" %)((( 852 -HSX1870.0 = 0, Static IP mode 853 - 854 -HSX1870.0 = 1, dynamic IP mode 855 -))) 856 -|=(% style="width: 160px;" %)((( 857 -HSW1871 858 -)))|(% style="width:282px" %)((( 859 -Confirm the IP, subnet mask, gateway, DNS1, DNS2, and dynamic static IP settings for Ethernet1 860 -)))|(% style="width:452px" %)((( 861 -~= 1, confirm the setting (i.e., after modifying IP-related information, set this address to 1, representing confirmation of the modification, after which it will be reset to 0) 862 -))) 863 -|=(% style="width: 160px;" %)((( 864 -HSW1872 865 -)))|(% colspan="1" rowspan="8" style="width:282px" %)((( 866 -①Display and modify DNS1 and DNS2 of Ethernet1 867 - 868 -②Related registers can be read and written mode (only static IP mode can be written) 869 -)))|(% style="width:452px" %)((( 870 -Ethernet1 Local DNS1 address high byte 1 871 -))) 872 -|=(% style="width: 160px;" %)((( 873 -HSW1873 874 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 2 875 -|=(% style="width: 160px;" %)((( 876 -HSW1874 877 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 3 878 -|=(% style="width: 160px;" %)((( 879 -HSW1875 880 -)))|(% style="width:452px" %)Ethernet1 Local DNS1 address high byte 4 881 -|=(% style="width: 160px;" %)((( 882 -HSW1876 883 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 1 884 -|=(% style="width: 160px;" %)((( 885 -HSW1877 886 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 2 887 -|=(% style="width: 160px;" %)((( 888 -HSW1878 889 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 3 890 -|=(% style="width: 160px;" %)((( 891 -HSW1879 892 -)))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 893 893 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 894 894 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 895 -Note: Valid when Ethernet1 of HMI is plugged into the network cable. 896 -①、When the Ethernet setting is enabled in the project parameters, this register displays the set value. 897 -②. When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 898 -③. When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 899 -④.IP related registers can be read and written (only static IP mode can be written). 664 +**✎Note: **Only valid when the HMI is plugged into the Ethernet cable. 665 + 666 +1. If Ethernet settings is enabled in project parameters, this register displays the set value. 667 +1. If Ethernet settings is not enabled in project parameters, IP would automatically obtained IP. 668 +1. If HMI is not connected to the network, the register is displayed as 0 whether the engineering parameters are set. 669 +1. 4. All IP registers of HMI are read-only. 900 900 )))|(% style="width:452px" %)Local IP address high byte 1 901 901 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 902 902 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -911,11 +911,9 @@ 911 911 |=(% style="width: 160px;" %)HSW10046|(% style="width:452px" %)Local gateway address high byte 4 912 912 |=(% style="width: 160px;" %)HSW10047|(% style="width:452px" %)Local port address 913 913 |=(% style="width: 160px;" %)HSW10048|(% rowspan="6" style="width:282px" %)((( 914 - ①Display the MAC code ofEthernet1NIC684 +Displays the MAC code of the current network card 915 915 916 -(hexadecimal display) 917 - 918 -②Read-only mode, not modifiable 686 +(Hexadecimal display) 919 919 )))|(% style="width:452px" %)Local MAC code high word 1 920 920 |=(% style="width: 160px;" %)HSW10049|(% style="width:452px" %)Local MAC code high word 2 921 921 |=(% style="width: 160px;" %)HSW10050|(% style="width:452px" %)Local MAC code high word 3 ... ... @@ -922,7 +922,7 @@ 922 922 |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4 923 923 |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5 924 924 |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6 925 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC693 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 926 926 |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 927 927 |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password 928 928 |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit) ... ... @@ -1004,36 +1004,9 @@ 1004 1004 ))) 1005 1005 |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second. 1006 1006 |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver 1007 -|=(% style="width: 160px;" %)((( 1008 -HSW11762 1009 -)))|(% style="width:282px" %)((( 1010 -Dynamic screensaver control address 1011 -)))|(% style="width:452px" %)((( 1012 -HSX11762.0=0, initialize with project configuration; 1013 1013 1014 - HSX11762.0=1,initializewithspecial registerconfiguration;776 +== **Serial port communication configuration** == 1015 1015 1016 -HSX11762.1=0, disable dynamic screensaver; 1017 - 1018 -HSX11762.1=1, enable dynamic screensaver 1019 -))) 1020 -|=(% style="width: 160px;" %)((( 1021 -HSW11763 1022 -)))|(% style="width:282px" %)((( 1023 -Waiting time to enter the dynamic screensaver 1024 -)))|(% style="width:452px" %)((( 1025 -Waiting time when the screen is not operated, range 1~~720 minutes 1026 -))) 1027 -|=(% style="width: 160px;" %)((( 1028 -HSW11764 1029 -)))|(% style="width:282px" %)((( 1030 -Animated screensaver animation type 1031 -)))|(% style="width:452px" %)((( 1032 -~=0: Raster,=1: Blinds,=2: Bubble 1033 -))) 1034 - 1035 -== Serial port communication configuration == 1036 - 1037 1037 (% class="table-bordered" %) 1038 1038 |=(% scope="row" style="width: 102px;" %)Port|=(% style="width: 173px;" %)**Function**|=(% style="width: 122px;" %)**Address**|=(% colspan="2" style="width: 506px;" %)**Description** 1039 1039 |(% colspan="1" rowspan="11" style="width:102px" %)COM1|(% style="width:173px" %)Communication mode|(% style="width:122px" %)HSW10061|(% colspan="2" style="width:506px" %)((( ... ... @@ -1327,19 +1327,18 @@ 1327 1327 For example, when the baud rate required is 250000, just enter 250. 1328 1328 ))) 1329 1329 1330 -== Ethernet communication configuration == 1071 +== **Ethernet communication configuration** == 1331 1331 1332 1332 (% class="table-bordered" %) 1333 -|(% style="width:40px" %)**No.**|(% style="width:295px" %)**Function**|(% style="width:220px" %)**Address**|(% style="width:336px" %)**Description** 1074 +|=(% style="width: 40px;" %)**No.**|=(% style="width: 295px;" %)**Function**|=(% style="width: 220px;" %)**Address**|=(% style="width: 336px;" %)**Description** 1334 1334 |(% rowspan="7" style="width:40px" %)1|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 1 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11004|(% style="width:336px" %)Device IP address high word 1 1335 1335 |(% style="width:220px" %)HSW11005|(% style="width:336px" %)Device IP address high word 2 1336 1336 |(% style="width:220px" %)HSW11006|(% style="width:336px" %)Device IP address high word 3 1337 1337 |(% style="width:220px" %)HSW11007|(% style="width:336px" %)Device IP address high word 4 1338 1338 |(% style="width:220px" %)HSW11008|(% style="width:336px" %)Device Port number 1339 -|(% style="width:220px" %)HSW11009|(% style="width:336px" %)((( 1340 -~=2 TCP 1341 - 1342 -~=3 UDP 1080 +|(% style="width:220px" %)HSW11009|=(% style="width: 336px;" %)((( 1081 +* =2 TCP 1082 +* =3 UDP 1343 1343 ))) 1344 1344 |(% style="width:220px" %)HSW11010|(% style="width:336px" %)Reserved 1345 1345 |(% rowspan="7" style="width:40px" %)2|(% colspan="1" rowspan="7" style="width:295px" %)Ethernet parameter configuration for communication number 2 in list. Configure those addresses according to connected device. After configuration, wait for 5 seconds and restart the HMI.|(% style="width:220px" %)HSW11011|(% style="width:336px" %)Device IP address high word 1 ... ... @@ -1347,10 +1347,9 @@ 1347 1347 |(% style="width:220px" %)HSW11013|(% style="width:336px" %)Device IP address high word 3 1348 1348 |(% style="width:220px" %)HSW11014|(% style="width:336px" %)Device IP address high word 4 1349 1349 |(% style="width:220px" %)HSW11015|(% style="width:336px" %)Device Port number 1350 -|(% style="width:220px" %)HSW11016|(% style="width:336px" %)((( 1351 -~=2 TCP 1352 - 1353 -~=3 UDP 1090 +|(% style="width:220px" %)HSW11016|=(% style="width: 336px;" %)((( 1091 +* =2 TCP 1092 +* =3 UDP 1354 1354 ))) 1355 1355 |(% style="width:220px" %)HSW11017|(% style="width:336px" %)Reserved 1356 1356 |(% style="width:40px" %)…|(% style="width:295px" %) |(% style="width:220px" %)…|(% style="width:336px" %)… ... ... @@ -1359,11 +1359,7 @@ 1359 1359 |(% style="width:220px" %)HSW11223|(% style="width:336px" %)Device IP address high word 3 1360 1360 |(% style="width:220px" %)HSW11224|(% style="width:336px" %)Device IP address high word 4 1361 1361 |(% style="width:220px" %)HSW11225|(% style="width:336px" %)Device Port number 1362 -|(% style="width:220px" %)HSW11226|(% style="width:336px" %)((( 1363 -~=2 TCP; 1364 - 1365 -~=3 UDP 1366 -))) 1101 +|(% style="width:220px" %)HSW11226|=(% style="width: 336px;" %)2 TCP; =3 UDP 1367 1367 |(% style="width:220px" %)HSW11227|(% style="width:336px" %)Reserved 1368 1368 1369 1369 (% class="box infomessage" %) ... ... @@ -1371,7 +1371,7 @@ 1371 1371 **✎Note:** The number of Ethernet connections supported by different HMI series varies. 1372 1372 ))) 1373 1373 1374 -== Communication control == 1109 +== **Communication control** == 1375 1375 1376 1376 (% class="table-bordered" %) 1377 1377 |=(% style="width: 135px;" %)**Communication No.**|=(% style="width: 102px;" %)**Station No.**|=(% style="width: 185px;" %)**Control bit**|=(% style="width: 191px;" %)**Communication lamp**|=(% style="width: 271px;" %)**Description**