Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 16.3
edited by Hunter
on 2023/02/18 11:32
Change comment: There is no comment for this version
To version 12.1
edited by Bob
on 2023/01/07 14:26
Change comment: There is no comment for this version

Summary

Details

Page properties
Author
... ... @@ -1,1 +1,1 @@
1 -XWiki.Hunter
1 +XWiki.Bob
Content
... ... @@ -241,8 +241,8 @@
241 241  * =2: HSX521.1=1, delete all trend graph.
242 242  * =4: HSX521.2=1, delete all alarms.
243 243  * =16: HSX521.4=1, delete history XY plot.
244 -* =32: HSX521.5=1, delete data records in SD card or USB flash disk;(Please make a setting which is saved to USB flash disk or SD card in project setting).
245 -* =64: HSX521.6=1, delete alarms records in SD card or USB flash disk; (Please make a setting which is saved to USB flash disk or SD card in project setting).
244 +* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting).
245 +* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting).
246 246  )))
247 247  |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)(((
248 248  * =0: No operation
... ... @@ -485,8 +485,6 @@
485 485  * =0, Default value
486 486  * =1, Release the alarm generated before the last power-down when starting up
487 487  )))
488 -|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
489 -|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
490 490  |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)(((
491 491  * =0, Disable
492 492  * =1, Enable
... ... @@ -593,9 +593,6 @@
593 593  * =0: Server connection exception
594 594  * =1: Server connection is OK
595 595  )))
596 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal signal strength|(% style="width:452px" %)(((
597 -Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
598 -)))
599 599  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
600 600  |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2
601 601  |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3
... ... @@ -795,8 +795,6 @@
795 795  |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)(((
796 796  * =0: db database
797 797  * =1: CSV
798 -
799 -(Only valid for script function DbToCsvFile)
800 800  )))
801 801  |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)(((
802 802  * =0: use the old high-low word conversion (default)
... ... @@ -823,9 +823,9 @@
823 823  * =1: priority WLAN
824 824  * =2: priority 4G
825 825  )))
826 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
819 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)(((
827 827  * =0: delete;
828 -* = Others value: do not delete
821 +* = Others: do not delete
829 829  )))
830 830  |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
831 831  Monitor address is set during reset of reset switch, whether to cancel reset,
... ... @@ -840,13 +840,6 @@
840 840  * = 1: no
841 841  )))
842 842  |=(% style="width: 160px;" %)(((
843 -HSW1869
844 -)))|(% style="width:282px" %)(((
845 -Dynamic screensaver countdown
846 -)))|(% style="width:452px" %)(((
847 -Countdown to enter dynamic screensaver effect, unit (S)
848 -)))
849 -|=(% style="width: 160px;" %)(((
850 850  HSW1870
851 851  )))|(% style="width:282px" %)(((
852 852  Display or set the dynamic or static IP mode of Ethernet1
... ... @@ -924,7 +924,7 @@
924 924  |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4
925 925  |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5
926 926  |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6
927 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
913 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC
928 928  |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC
929 929  |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password
930 930  |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)
... ... @@ -1006,34 +1006,7 @@
1006 1006  )))
1007 1007  |=(% style="width: 160px;" %)HSW11760|(% style="width:282px" %)Screensaver countdown|(% style="width:452px" %)Display the countdown to enter the Screensaver, unit: second.
1008 1008  |=(% style="width: 160px;" %)HSW11761|(% style="width:282px" %)Screensaver screen number|(% style="width:452px" %)Set the screen number for Screensaver
1009 -|=(% style="width: 160px;" %)(((
1010 -HSW11762
1011 -)))|(% style="width:282px" %)(((
1012 -Dynamic screensaver control address
1013 -)))|(% style="width:452px" %)(((
1014 -HSX11762.0=0, initialize with project configuration;
1015 1015  
1016 -HSX11762.0=1, initialize with special register configuration;
1017 -
1018 -HSX11762.1=0, disable dynamic screensaver;
1019 -
1020 -HSX11762.1=1, enable dynamic screensaver
1021 -)))
1022 -|=(% style="width: 160px;" %)(((
1023 -HSW11763
1024 -)))|(% style="width:282px" %)(((
1025 -Waiting time to enter the dynamic screensaver
1026 -)))|(% style="width:452px" %)(((
1027 -Waiting time when the screen is not operated, range 1~~720 minutes
1028 -)))
1029 -|=(% style="width: 160px;" %)(((
1030 -HSW11764
1031 -)))|(% style="width:282px" %)(((
1032 -Animated screensaver animation type
1033 -)))|(% style="width:452px" %)(((
1034 -~=0: Raster,=1: Blinds,=2: Bubble
1035 -)))
1036 -
1037 1037  == Serial port communication configuration ==
1038 1038  
1039 1039  (% class="table-bordered" %)