Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -241,8 +241,8 @@ 241 241 * =2: HSX521.1=1, delete all trend graph. 242 242 * =4: HSX521.2=1, delete all alarms. 243 243 * =16: HSX521.4=1, delete history XY plot. 244 -* =32: HSX521.5=1, delete data records in SD card or USBflash disk;(Please make a setting which is saved toUSBflash disk or SD card in project setting).245 -* =64: HSX521.6=1, delete alarms records in SD card or USBflash disk; (Please make a setting which is saved toUSBflash disk or SD card in project setting).244 +* =32: HSX521.5=1, delete data records in SD card or flash dish;(Please make a setting which is saved to flash disk or SD card in project setting). 245 +* =64: HSX521.6=1, delete alarms records in SD card or flash dish; (Please make a setting which is saved to flash disk or SD card in project setting). 246 246 ))) 247 247 |=(% style="width: 160px;" %)HSW522|(% style="width:282px" %)Copy and paste the alarm/data files in flash to the USB flash disk|(% style="width:452px" %)((( 248 248 * =0: No operation ... ... @@ -485,8 +485,6 @@ 485 485 * =0, Default value 486 486 * =1, Release the alarm generated before the last power-down when starting up 487 487 ))) 488 -|=(% style="width: 160px;" %)HSW1200|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol(ig series or HMI V2.0)|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 489 -|=(% style="width: 160px;" %)HSW1201|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 490 490 |=(% style="width: 160px;" %)HSW1450|(% style="width:282px" %)Enable objects level password function|(% style="width:452px" %)((( 491 491 * =0, Disable 492 492 * =1, Enable ... ... @@ -593,9 +593,6 @@ 593 593 * =0: Server connection exception 594 594 * =1: Server connection is OK 595 595 ))) 596 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal signal strength|(% style="width:452px" %)((( 597 -Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890) 598 -))) 599 599 |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1 600 600 |=(% style="width: 160px;" %)HSW1742|(% style="width:452px" %)Local IP address high byte 2 601 601 |=(% style="width: 160px;" %)HSW1743|(% style="width:452px" %)Local IP address high byte 3 ... ... @@ -795,8 +795,6 @@ 795 795 |=(% style="width: 160px;" %)HSW1853|(% style="width:282px" %)File format for exporting data records to USB flash drive or SD card|(% style="width:452px" %)((( 796 796 * =0: db database 797 797 * =1: CSV 798 - 799 -(Only valid for script function DbToCsvFile) 800 800 ))) 801 801 |=(% style="width: 160px;" %)HSW1854|(% style="width:282px" %)High and low word conversion type|(% style="width:452px" %)((( 802 802 * =0: use the old high-low word conversion (default) ... ... @@ -823,9 +823,9 @@ 823 823 * =1: priority WLAN 824 824 * =2: priority 4G 825 825 ))) 826 -|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the L ua extension module file|(% style="width:452px" %)(((819 +|=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the LUa extension module file|(% style="width:452px" %)((( 827 827 * =0: delete; 828 -* = Others value: do not delete821 +* = Others: do not delete 829 829 ))) 830 830 |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 831 831 Monitor address is set during reset of reset switch, whether to cancel reset, ... ... @@ -924,7 +924,7 @@ 924 924 |=(% style="width: 160px;" %)HSW10051|(% style="width:452px" %)Local MAC code high word 4 925 925 |=(% style="width: 160px;" %)HSW10052|(% style="width:452px" %)Local MAC code high word 5 926 926 |=(% style="width: 160px;" %)HSW10053|(% style="width:452px" %)Local MAC code high word 6 927 -|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens LOGO! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC920 +|=(% style="width: 160px;" %)HSW10118|(% colspan="1" rowspan="2" style="width:282px" %)TSAP settings for HMI in the Siemens logo! 8 protocol|(% style="width:452px" %)HMI local TSAP, which corresponds to the remote TSAP of PLC 928 928 |=(% style="width: 160px;" %)HSW10119|(% style="width:452px" %)HMI remote TSAP, which corresponds to the local TSAP of PLC 929 929 |=(% style="width: 160px;" %)HSW10461~~10493|(% style="width:282px" %)Remote access password|(% style="width:452px" %)8-character remote access password 930 930 |=(% style="width: 160px;" %)HSW10494~~10558|(% style="width:282px" %)Machine ID (Read only)|(% style="width:452px" %)Machine ID for remote access (read only 64-bit)