Changes for page 13 HMI Internal Registers

Last modified by Jett on 2025/04/28 16:07

From version 16.3
edited by Hunter
on 2023/02/18 11:32
Change comment: There is no comment for this version
To version 17.1
edited by Hunter
on 2023/02/18 13:53
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -593,7 +593,7 @@
593 593  * =0: Server connection exception
594 594  * =1: Server connection is OK
595 595  )))
596 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal signal strength|(% style="width:452px" %)(((
596 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)(((
597 597  Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890)
598 598  )))
599 599  |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1
... ... @@ -825,7 +825,7 @@
825 825  )))
826 826  |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)(((
827 827  * =0: delete;
828 -* = Others value: do not delete
828 +* = Others: do not delete
829 829  )))
830 830  |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)(((
831 831  Monitor address is set during reset of reset switch, whether to cancel reset,
... ... @@ -892,6 +892,15 @@
892 892  |=(% style="width: 160px;" %)(((
893 893  HSW1879
894 894  )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4
895 +|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)(((
896 +* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval)
897 +* =Others: not refresh
898 +)))
899 +|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data  |(% style="width:452px" %)(((
900 +* =1, not clear screen cache when switch language
901 +* =2, trigger clear cache of all screens for once time
902 +* =3, always clear cache of all screen data
903 +)))
895 895  |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains
896 896  |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)(((
897 897  Note: Valid when Ethernet1 of HMI is plugged into the network cable.