Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -25,6 +25,19 @@ 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 26 ))) 27 27 28 += Address ranges table = 29 + 30 +|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i Series/HMI+ models|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series 31 +|=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999 32 +|=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999 33 +|=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999 34 +|=(% style="width: 218px;" %)HUW|(% style="width:228px" %)HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599 35 +|=(% style="width: 218px;" %)HDX|(% style="width:228px" %)HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15 36 +|=(% style="width: 218px;" %)HSX|(% style="width:228px" %)HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15 37 +|=(% style="width: 218px;" %)HAX|(% style="width:228px" %)HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15 38 +|=(% style="width: 218px;" %)HUX|(% style="width:228px" %)HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15 39 +|=(% style="width: 218px;" %)RPW|(% style="width:228px" %) |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450 40 + 28 28 = **Data storage area (HDW/HDX)** = 29 29 30 30 It is used to save the temporary data of project. ... ... @@ -593,7 +593,7 @@ 593 593 * =0: Server connection exception 594 594 * =1: Server connection is OK 595 595 ))) 596 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal s ignal strength|(% style="width:452px" %)(((609 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)((( 597 597 Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890) 598 598 ))) 599 599 |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1 ... ... @@ -825,7 +825,7 @@ 825 825 ))) 826 826 |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)((( 827 827 * =0: delete; 828 -* = Others value: do not delete841 +* = Others: do not delete 829 829 ))) 830 830 |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 831 831 Monitor address is set during reset of reset switch, whether to cancel reset, ... ... @@ -892,6 +892,15 @@ 892 892 |=(% style="width: 160px;" %)((( 893 893 HSW1879 894 894 )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 908 +|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)((( 909 +* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval) 910 +* =Others: not refresh 911 +))) 912 +|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data |(% style="width:452px" %)((( 913 +* =1, not clear screen cache when switch language 914 +* =2, trigger clear cache of all screens for once time 915 +* =3, always clear cache of all screen data 916 +))) 895 895 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 896 896 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 897 897 Note: Valid when Ethernet1 of HMI is plugged into the network cable.