Changes for page 13 HMI Internal Registers
Last modified by Jett on 2025/04/28 16:07
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -25,6 +25,20 @@ 25 25 * The address of the bit address HDX is with a decimal point while word addresses are integers. 26 26 ))) 27 27 28 += Address ranges table = 29 + 30 +(% cellpadding="10" %) 31 +|=(% scope="row" style="width: 218px;" %)Address Type\HMI Series|=(% style="width: 228px;" %)General Series|=(% style="width: 200px;" %)i /HMI+ Series|=(% style="width: 136px;" %)ie Series|=(% style="width: 232px;" %)ig Series 32 +|=(% style="width: 218px;" %)HDW|(% style="width:228px" %)HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999|HDW0-HDW299999 33 +|=(% style="width: 218px;" %)HSW|(% style="width:228px" %)HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999|HSW0-HSW14999 34 +|=(% style="width: 218px;" %)HAW|(% style="width:228px" %)HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999|HAW0-HAW199999 35 +|=(% style="width: 218px;" %)HUW|(% style="width:228px" %)HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599|HUW0-HUW1599 36 +|=(% style="width: 218px;" %)HDX|(% style="width:228px" %)HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15|HDX0.0-HDX299999.15 37 +|=(% style="width: 218px;" %)HSX|(% style="width:228px" %)HSX0.0-HSX14999.15|HSX0.0-HSX14999.15|HSX0-HSX14999.15|HSX0.0-HSX14999.15 38 +|=(% style="width: 218px;" %)HAX|(% style="width:228px" %)HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15|HAX0.0-HAX199999.15 39 +|=(% style="width: 218px;" %)HUX|(% style="width:228px" %)HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15|HUX0.0-HUX1599.15 40 +|=(% style="width: 218px;" %)RPW|(% style="width:228px" %) |RPW000000-RPW990450|RPW000000-RPW990450|RPW000000-RPW990450 41 + 28 28 = **Data storage area (HDW/HDX)** = 29 29 30 30 It is used to save the temporary data of project. ... ... @@ -60,8 +60,8 @@ 60 60 61 61 It is used for system special registers (reserved by system). 62 62 63 -1. Access as word, and serial number range is from HUW0 to HUW199 999.64 -1. Access as bit, and serial number range is from HUX0.0 to HUX199 999.15.77 +1. Access as word, and serial number range is from HUW0 to HUW1599. 78 +1. Access as bit, and serial number range is from HUX0.0 to HUX1599.15. 65 65 66 66 **✎Note:** 67 67 ... ... @@ -150,7 +150,7 @@ 150 150 ))) 151 151 |=(% style="width: 160px;" %)HSW6~~HSW7|(% style="width:282px" %)Number of alarms|(% style="width:452px" %)The number of alarm (it also includes the records of alarm confirmed) 152 152 |=(% style="width: 160px;" %)HSW8|(% style="width:282px" %)Number of unconfirmed history alarm|(% style="width:452px" %)The number of unconfirmed history alarm 153 -|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out tip|(% style="width:452px" %)(((167 +|=(% style="width: 160px;" %)HSW9|(% style="width:282px" %)Time out prompt|(% style="width:452px" %)((( 154 154 * =0: Enable 155 155 * =1: Disable 156 156 ))) ... ... @@ -450,7 +450,7 @@ 450 450 Address mapping polling cycle, effective range: 40~~1000ms, default: 300ms. 451 451 452 452 * When the set value is greater than 1000, the value is 1000. 453 -* When the set value is greater than1000, it changes to the default value 300467 +* When the set value is lower than 40, it changes to the default value 300 454 454 ))) 455 455 |=(% style="width: 160px;" %)HSW1087|(% style="width:282px" %)Control write interval in address mapping|(% style="width:452px" %)((( 456 456 After reading data to the device for N times, Perform an address mapping write operation. N is the interval value. The effective range: 0~~5, and default is 2. ... ... @@ -593,7 +593,7 @@ 593 593 * =0: Server connection exception 594 594 * =1: Server connection is OK 595 595 ))) 596 -|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal s ignal strength|(% style="width:452px" %)(((610 +|=(% style="width: 160px;" %)HSW1740|(% style="width:282px" %)Wi-fi signal strength|(% style="width:452px" %)((( 597 597 Display the value of Wi-fi signal signal strength, ranges from 0~~100 (Signal strength is automatically obtained only once when HMI is powered on, and it will not be automatically updated. It needs to be used with the HSW1890) 598 598 ))) 599 599 |=(% style="width: 160px;" %)HSW1741|(% colspan="1" rowspan="12" style="width:282px" %)Related IP register in 4Gnetwork status (It is valid when HMI is connected to 4G)|(% style="width:452px" %)Local IP address high byte 1 ... ... @@ -825,7 +825,7 @@ 825 825 ))) 826 826 |=(% style="width: 160px;" %)HSW1866|(% style="width:282px" %)Delete the Lua extension module file|(% style="width:452px" %)((( 827 827 * =0: delete; 828 -* = Others value: do not delete842 +* = Others: do not delete 829 829 ))) 830 830 |=(% style="width: 160px;" %)HSW1867|(% style="width:282px" %)Reset mode|(% style="width:452px" %)((( 831 831 Monitor address is set during reset of reset switch, whether to cancel reset, ... ... @@ -892,13 +892,22 @@ 892 892 |=(% style="width: 160px;" %)((( 893 893 HSW1879 894 894 )))|(% style="width:452px" %)Ethernet1 Local DNS2 address high byte 4 909 +|=(% style="width: 160px;" %)HSW1890|(% colspan="1" style="width:282px" %)Enable refresh current network signal|(% style="width:452px" %)((( 910 +* =1: Refresh the network signal once after triggered (This register will be automatically reset after triggered, only update the signal value once after per 15 seconds, not able to update twice in the short interval) 911 +* =Others: not refresh 912 +))) 913 +|=(% style="width: 160px;" %)HSW1891|(% colspan="1" style="width:282px" %)Enable clear cache for screen data |(% style="width:452px" %)((( 914 +* =1, not clear screen cache when switch language 915 +* =2, trigger clear cache of all screens for once time 916 +* =3, always clear cache of all screen data 917 +))) 895 895 |=(% style="width: 160px;" %)HSW10000~~19999|(% style="width:282px" %)Power-down storage area|(% style="width:452px" %)After restart, the data remains 896 896 |=(% style="width: 160px;" %)HSW10035|(% rowspan="13" style="width:282px" %)((( 897 897 Note: Valid when Ethernet1 of HMI is plugged into the network cable. 898 -① 、When the Ethernet setting is enabled in the project parameters, this register displays the set value.899 -② .When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI.900 -③ .When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not.901 -④ .IP related registers can be read and written (only static IP mode can be written).921 +① When the Ethernet setting is enabled in the project parameters, this register displays the set value. 922 +② When the Ethernet setting is not enabled in the engineering parameters, the register displays the Ethernet IP automatically acquired by the HMI. 923 +③ When the HMI is not plugged into the network cable, the register will show 0 whether the engineering parameters are set or not. 924 +④ IP related registers can be read and written (only static IP mode can be written). 902 902 )))|(% style="width:452px" %)Local IP address high byte 1 903 903 |=(% style="width: 160px;" %)HSW10036|(% style="width:452px" %)Local IP address high byte 2 904 904 |=(% style="width: 160px;" %)HSW10037|(% style="width:452px" %)Local IP address high byte 3